PARTS CATALOG MUZ-HJ25VA - E1, ER1, ET1 MUZ-HJ35VA - E1, ER1, ET1 MUZ-HJ50VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBB648 REVISED EDITION-C.



Similar documents
PARTS CATALOG OUTDOOR UNIT. No. OBB516. Models

PARTS CATALOG MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE INDOOR UNIT. No. OBB623. Models

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL MUZ-HJ25VA MUZ-HJ35VA OUTDOOR UNIT. No. OBH648. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

SERVICE MANUAL MU-A09WA MU-A12WA MU-A12WA- 1 OUTDOOR UNIT. No. OB449. Wireless type Models HFC. Revision : A SPLIT-TYPE AIR CONDITIONERS

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

SERVICE MANUAL MSZ-A18YV - E1 MSZ-A24YV - MSZ-A24YV - E1 INDOOR UNIT. No. OB345 REVISED EDITION-A. Models. Revision A : SPLIT-TYPE AIR CONDITIONERS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SERVICE MANUAL INDOOR UNIT

SERVICE MANUAL INDOOR UNIT

Split units TH with hermetic compressors

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

Failure code manual. content

NSN

SERVICE MANUAL MUZ-GC25VA - MUZ-GC25VAH - MUZ-GC35VA - MUZ-GC35VAH - E1 OUTDOOR UNIT. No. OBH469. Wireless type Models HFC

Room Air Conditioner SVC MANUAL(Exploded View)

SERVICE MANUAL MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA INDOOR UNIT. No. OBH647. Models. Revision A: MSZ-HJ50VA- E1 has been added.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

AIR CONDITIONER INSTALLATION MANUAL

SERVICE MANUAL INDOOR UNIT MSZ-EF35VEW MSZ-EF22VEB - - E1 MSZ-EF25VEB E1 MSZ-EF35VEB - - E1 MSZ-EF35VEB E1 MSZ-EF35VES - E1 - E1 MSZ-EF22VEW -

SERVICE MANUAL MXZ-2A20NA MXZ-2A20NA - MXZ-3A30NA MXZ-3A30NA - MXZ-4A36NA OUTDOOR UNIT. No. OB444. Models HFC. Inverter-controlled multi system type


MDT5N25 & MTD5N40 SERVICE PARTS

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

How To Measure Temperature On A Thermostat

Service & Parts Manual

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

PANASONIC TROUBLE SHOOTING GUIDE

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Reverse Cycle Inverter Split System Air Conditioner

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

AIR CONDITIONING SYSTEMS

SWIMMING POOL HEAT PUMP

Condensing unit type EPSILON-ECHOS LE Technical information manual

HP switch LP switch Discharge thermo Comp. Surface thermo

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Repair Guideline for TCL DC Inverter Air Conditioner

REPLACEMENT PARTS LIST Single Package Air Conditioner (*)P3 Series 10 SEER and 12 SEER Models

Local Dealer:

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

SECTION HEAT PUMPS

SERVICE MANUAL INDOOR UNIT. No. OB450. Models. Revision D: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-D

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Midea Commercial Air Conditioner Malfunction Handbook

How To Power A Car With A Fan And A Fan (Power)

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

TAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Split air conditioner Wall mounted Type. Service manual

28 REPLACEMENT PARTS INDOOR UNIT CS-W18BD3P, CS-W24BD3P, CS-W28BD3P

MAYTAG MFD2560HEB NACIONAL E IMPORTACIÓN CABINET BACK

Split air conditioner Wall mounted Type Service manual

OWNER S GUIDE OPERATION & INSTALLATION

Air Conditioners Technical Data

SECTION MORTUARY REFRIGERATORS

UNIVERSAL 1550 PRE-MIX DISPENSER

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Acumen Enterprises, Inc.

TWE+TTA TWE+TWA T.R.

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Appendix - Controllers 179

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

HITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Technical Service Manual. Version One

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Split System Heat Pump Product Data

Single Zone LCD Thermostat Operating Instructions

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

COMMISSIONING OF HVAC SYSTEMS

Technical service manual

SERVICE MANUAL MSZ-FD25VA - MSZ-FD25VAS - MSZ-FD35VA - MSZ-FD35VAS - MSZ-FD50VA - MSZ-FD50VAS - INDOOR UNIT. No. OBH488. Models

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

RUUD AIR CONDITIONERS & HEAT PUMPS

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Transcription:

SPLIT-TYPE AIR CONDITIONERS Revision C: MUZ-HJ25VA-, MUZ-HJ35VA- and MUZ-HJ50VA- have been added. The defrost heater for MUZ-HJ25VA and MUZ- HJ35VA has been added to the optional parts. Please void OBB648 REVISED EDITION-B. OUTDOOR UNIT PARTS CATALOG HFC utilized R410A No. OBB648 REVISED EDITION-C Models MUZ-HJ25VA -,, MUZ-HJ35VA -,, MUZ-HJ50VA -,, MUZ-HJ25VA MUZ-HJ35VA CONTENTS 1. RoHS PARTS LIST 2 2. OPTIONAL PARTS 10 SERVICE MANUAL (OBH648) NOTE: RoHS compliant products have <G> mark on the spec name plate.

Revision A: MUZ-HJ50VA- has been added. Revision B: MUZ-HJ25VA-, MUZ-HJ35VA- and MUZ-HJ50VA- have been added. Revision C: MUZ-HJ25VA-, MUZ-HJ35VA- and MUZ-HJ50VA- have been added. The defrost heater for MUZ-HJ25VA and MUZ-HJ35VA has been added to the optional parts. 1 RoHS PARTS LIST MUZ-HJ25VA MUZ-HJ35VA 1-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 17 16 15 12 11 18 19 14 13 10 9 1 2 3 4 5 6 7 8 2

1-1. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS Part number that is circled is not shown in the illustration. No. RoHS Part No. Part Name Symbol in Wiring Diagram Q ty/unit MUZ-HJ 25VA- 25VA- 25VA- 35VA- 35VA- 35VA- 1 G 2 J98 521 GRILLE 1 1 1 1 1 1 2 G 2 N84 232 CABINET 1 1 1 1 1 1 3 G 2 J98 290 BASE 1 1 1 1 1 1 Remarks 4 G 2 J98 293 SEPARATOR 1 1 1 1 1 1 5 G 2 J98 900 1 1 1 KNB065FUJHC COMPRESSOR MC G 2 J99 900 1 1 1 KNB073FUVHC 6 G 2 C34 506 COMPRESSOR RUBBER SET 3 3 3 3 3 3 3 RUBBERS/SET 7 G 2 J98 661 STOP VALVE (GAS) 1 1 1 1 1 1 ø9.52 8 G 2 J98 662 STOP VALVE (LIQUID) 1 1 1 1 1 1 ø6.35 9 G 2 J98 493 1 1 1 EXPANSION VALVE COIL LEV G 2 J99 493 1 1 1 10 G 2 J98 640 1 1 1 EXPANSION VALVE G 2 J99 640 1 1 1 11 G 2 J98 245 SERVICE PANEL 1 1 1 1 1 1 12 G 2 J98 233 BACK PANEL 1 1 1 1 1 1 13 G 2 D65 961 4-WAY VALVE 1 1 1 1 1 1 14 G 2 J98 515 1 1 1 1 MOTOR SUPPORT G 2 N84 515 1 1 15 G 2 J98 525 CONDENSER WIRE NET 1 1 1 1 1 1 16 G 2 J98 630 OUTDOOR HEAT EXCHANGER 1 1 1 1 1 1 17 G 2 J98 297 TOP PANEL 1 1 1 1 1 1 18 G 2 J98 301 OUTDOOR FAN MOTOR MF 1 1 1 1 1 1 RA6V21-19 G 2 B72 501 PROPELLER FAN 1 1 1 1 1 1 20 G 2 J98 936 CAPILLARY TUBE 1 1 1 1 1 1 ø3.0 ø1.4 260 3

MUZ-HJ25VA MUZ-HJ35VA 1-2. OUTDOOR UNIT ELECTRICAL PARTS 5 4 1 3 2 No. RoHS Part No. Part Name Symbol in Wiring Diagram Q ty/unit MUZ-HJ 25VA- 25VA- 25VA- 35VA- 35VA- 35VA- 1 G 2 G10 337 REACTOR L61 1 1 1 1 1 1 Remarks 2 G 2 J98 306 THERMISTOR SET RT61,RT62 1 1 1 1 1 1 DEFROST, DISCHARGE 3 G 2 J98 490 R.V. COIL 21S4 1 1 1 1 1 1 4 G 2 927 374 TERMINAL BLOCK TB 1 1 1 1 1 1 3 P 5 G 2 J98 451 1 1 1 Including heat sink INVERTER P.C. BOARD G 2 J99 451 1 1 1 and RT64 4

MUZ-HJ25VA MUZ-HJ35VA 1-3. DRAIN SOCKET 1 No. RoHS Part No. Part Name Symbol in Wiring Diagram Q ty/unit MUZ-HJ 25VA- 25VA- 25VA- 35VA- 35VA- 35VA- Remarks 1 G 2 817 704 DRAIN SOCKET 1 1 1 1 1 1 5

MUZ-HJ50VA 1-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS 17 16 15 14 18 10 9 19 20 1 13 12 11 2 3 4 5 6 7 8 6

1-4. OUTDOOR UNIT STRUCTURAL PARTS AND FUNCTIONAL PARTS Part numbers that are circled are not shown in the illustration. No. RoHS Part No. Part Name Symbol in Wiring Diagram Q'ty/unit MUZ-HJ 50VA- 50VA- 50VA- 1 G 2 927 232 CABINET 1 1 1 2 G 2 927 521 GRILLE 1 1 1 3 G 2 927 501 PROPELLER FAN 1 1 1 4 G 2 D69 290 BASE 1 1 1 Remarks 5 G 2 E05 900 COMPRESSOR MC 1 1 1 SNB130FGBHT 6 G 2 C34 506 COMPRESSOR RUBBER SET 3 3 3 3 RUBBERS/SET 7 G 2 D58 661 STOP VALVE (GAS) 1 1 1 ø12.7 8 G 2 D58 662 STOP VALVE (LIQUID) 1 1 1 ø6.35 9 G 2 927 245 SERVICE PANEL 1 1 1 10 G 2 G15 233 BACK PANEL 1 1 1 11 G 2 A54 640 EXPANSION VALVE 1 1 1 12 G 2 G10 493 EXPANSION VALVE COIL LEV 1 1 1 13 G 2 J44 961 4-WAY VALVE 1 1 1 14 G 2 930 525 CONDENSER WIRE NET 1 1 1 15 G 2 930 523 CONDENSER NET 1 1 1 16 G 2 G11 293 SEPARATOR 1 1 1 17 G 2 929 515 MOTOR SUPPORT 1 1 1 18 G 2 927 297 TOP PANEL 1 1 1 19 OUTDOOR HEAT G 2 K01 630 EXCHANGER 1 1 1 20 G 2 G11 301 OUTDOOR FAN MOTOR MF 1 1 1 RC0J50-21 G 2 J47 936 CAPILLARY TUBE 1 1 1 ø4.0 ø2.4 240 22 G 2 838 704 DRAIN SOCKET 1 1 1 7

MUZ-HJ50VA 1-5. OUTDOOR UNIT ELECTRICAL PARTS 8 7 6 5 4 1 2 3 8

1-5. OUTDOOR UNIT ELECTRICAL PARTS No. RoHS Part No. Part Name Symbol in Wiring Diagram Q'ty/unit MUZ-HJ 50VA- 50VA- 50VA- 1 G 2 G11 337 REACTOR L61 1 1 1 2 G 2 C34 306 THERMISTOR SET RT61, RT62 1 1 1 3 OUTDOOR HEAT EXCHANGER G 2 C34 307 TEMPERATURE THERMISTOR RT68 1 1 1 Remarks DEFROST, DISCHARGE 4 G 2 J47 490 R.V. COIL 21S4 1 1 1 5 G 2 735 241 FUSE HOLDER 1 1 1 6 G 2 735 382 FUSE F61 1 1 1 T20AL250V 7 G 2 K01 374 TERMINAL BLOCK TB 1 1 1 5 P 8 G 2 K01 451 INVERTER P.C. BOARD 1 1 1 Including heat sink and RT64 9

2 OPTIONAL PARTS 2-1. DEFROST HEATER Model Parts No. MUZ-HJ25VA MUZ-HJ35VA MAC-645BH-E Components Defrost heater 1 Thermistor 1 Insulation 1 Heater Support A 1 Cable fastener 1 Spec label 1 Heater support B 1 Cable strap 2 Wiring diagram 1 Heater support C 1 Screw 4 NOTE: Attaching the Freeze-prevention heater "MAC-645BH-E Anti-Freeze Heater" (for drain pan) to MUZ-HJ25/35VA requires installation of the SERVICE PARTS of INVERTER P.C. BOARD for MUZ-HJ25/35VA. Order the SERVICE PARTS of INVERTER P.C. BOARD for MUZ-HJ25/35VA as needed. Refer to the installation manual for the installation. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Copyright 2012 MITSUBISHI ELECTRIC CORPORATION Distributed in Aug. 2014. No. OBB648 REVISED EDITION-C Distributed in Dec. 2013. No. OBB648 REVISED EDITION-B Distributed in Mar. 2013. No. OBB648 REVISED EDITION-A Distributed in Dec. 2012. No. OBB648 Made in Japan 10 New publication, effective Aug. 2014 Specifications are subject to change without notice.