www.optimumheat.co.uk

Similar documents
PE1 Pellet. PE1 Pellet. Pellet boiler. PE1 Pellet.

High-efficient gas boiler CompactGas

Heating with wood chips and pellets

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

HIGH QUALITY COMPONENTS

P4 Pellet. Pellet boiler. P4 Pellet.

HAPERO BALANCE / FLASH. 15 kw / 25 kw / 35 kw. Basement Floor Living room ENERGIETECHNIK GMBH PLUG INSTITUT FÜR BRANDSCHUTZTECHNIK

Service & Maintenance Packages. Service & After-Sales. A Strong Company

Electric Flow Boiler

BIOHOUSING Seminar Success stories of biomass heating in small scale

Half the cost Half the carbon

Commercial Gas Water Heaters

Vacuum drying oven for non-flammable solvents

HEAVY DUTY STORAGE GAS

FilterFlow Automatic Water Boilers. Pure Quality

Top Technology for Industry, Agriculture, Business and Communities

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

Vitocaldens 222-F Compact Gas-Hybrid appliance

Product overview Air conditioning service units

helosauna.com STEAM BATH PRODUCTS

Drayton Digistat +2RF/+3RF

LABOKLAV. Autoclaves Made in Germany.

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Continuous flow direct water heating for potable hot water

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

Daikin Altherma Hybrid Heat Pump

G234X-55 Conventional Gas Boiler

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Brochure EX

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Laddomat Charging unit

Description of functions

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

OZW30. Central Unit SYNERGYR

Smile. The All-In-One Heating Controller

Rainwater Harvesting

Daikin Altherma Hybrid Heat Pump

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

Endless Hot Water 24/7

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Itho Products for Hot and Boiling water. product-

Material test chamber with mechanical convection

The power of innovation. For better media preparation. Media preparators Systec MediaPrep.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Operating instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

BIOMASS BOILER. Servicing and Maintenance Years. No Renewable Products Installed, Maintained

The soot and scale problems

Condensing Boiler Efficiency

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

1 DESCRIPTION OF THE APPLIANCE

Siemens and The Carbon Trust The Free Money Deal. Free Money. Money doesn t grow on trees. But it does now grow on roofs and in boiler houses.

Danish stoves - a cosy and eco-friendly heat source

Natural geothermal energy.

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23

OT 40L / 90L. Laboratory Steam Sterilizers

Gas Condensing Boilers

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Hot water supply, distribution and use

Freezers - Ultrafreezers. Platilab & Irilab Series

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Business Plan: Wood chip gasifier (Deliverable 5.2)

Ligentoplant - The biomass cogeneration. Ligento green power GmbH

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

Installation & User Instructions

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Cooking at the Speed of light!

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Power consumption (kw)

Commercial Gas Water Heaters

The natural ombination

UDSA - UDSBD unit heater

Safety Storage Cabinets

Incubator with mechanical convection

Sustainable Schools Renewable Energy Technologies. Andrew Lyle RD Energy Solutions

Baxi Combi 80e & 105e

Heating Controller. Building Technologies HVAC Products

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Heating oven with mechanical convection

Micro cogeneration. Affordable, efficient and innovative

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

ECOCIAT. Domestic hot water heat recovery unit

NIBE ACCESSORIES. NIBE Accessories A NEW GENERATION OF HEAT PUMPS

User s Manual Before using the inverter, you need to read and save the safety instructions.

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Heating oven with mechanical control

Daikin Altherma Hybrid Heat Pump

Transcription:

The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions Easy to install Seven year warranty Wood Pellet Boiler iq 3.0 4,7 to 30, 60, 90 + 120 kw 1

Optimum iq 3.0 System Features An Optimum iq wood pellet boiler provides clean, automatic and controllable heat. Its innovative combustion and control systems offer significant user benefits. At the heart of the boiler, developed in 2003 by a German company SOLARvent (www.solarvent.de), is the patented iq partition burner, which ensures the highest levels of efficiency, particularly during the power modulation phase. This is especially important at partial loads (down to 4.7kW), as the boiler still achieves combustion efficiencies of up to 98%. The design of the boiler also offers great flexibility as it has three output ratings, changed via a software key, and up to four boilers can be operated in series. This means that user needs can be precisely matched and makes installation easier. In 2011 the iqtouch operating system was developed. This is an ingenious operating system, that controls the biomass boiler optimally and easily, and users can link to it remotely - via a Smartphone, tablet or PC; allowing complete control, even while away from home or business. It offers the sort of advanced control features normally associated with much larger installations, at no extra cost. With more than 12 years production experience and many satisfied customers in Europe and the UK, you can rely on the features and quality of the Optimum iq. 2

Quality built-in Warranty, training and support We are so confident of the quality of the Optimum iq pellet boiler that, as the sole agent in the UK and Ireland, we offer a seven-year warranty against parts failure. The boiler is fully tested and certificated: CE Mark EN 303-5:2013 approved Type tested Energy use tested Optimum Heat offers a 365-day remote monitoring service. Each Optimum iq pellet boiler's iqtouch operating system will email our customer service team (and yours, if required) with information on any malfunction, and our maintenance technicians will attempt to solve the issue remotely. Should this not be possible you will be informed so that we can work together to solve the problem. We hold a comprehensive range of spares to minimise downtime. Our training centre is equipped with the latest Optimum iq technology. All of the boiler units are operational and topics covered include commissioning, servicing, fault finding and systems training. On-site training is also available, if required. 3

Optimum iq Innovation Maximum efficiency and flexibility The Optimum iq pellet boiler has a huge performance range from 4.7 to 30 kw, making it suitable for both domestic and commercial applications. This is due to the design of the partition burner which incorporates innovations that make the combustion more efficient and increases the operating efficiency significantly compared to its competitors. Efficient heating - thanks to the Patented iq partition burner Our patented partition burner provides a constant power modulation giving the highest efficiency across the output range. Even at part load, by far the most frequent operating level, it is up to 98% efficient. This high efficiency is achieved because the burner is always supplied with combustion air in the right place by the intelligent three-way air distribution system, in conjunction with a lambda probe. This ensures the highest levels of efficiency, even at loads down to 4.7kW. The power consumption for this operation is less than 1% of the current draw of the boiler. Built-in flexibility One standard pellet boiler can be configured for three different power outputs which can be changed at any time from 15.6 to 20 or 30 kw, even after installation, using a software key. Model: Min. Max. iq 3.0-150 4,7 kw 15,6 kw iq 3.0-200 4,7 kw 20,0 kw iq 3.0-270 4,7 kw 30,0 kw 2x iq 3.0-270s in series 4,7 kw 60,0 kw 3x iq 3.0-270s in series 4,7 kw 90,0 kw 4x iq 3.0-270s in series 4,7 kw 120,0 kw The Optimum iq has three possible power ratings and up to four boilers can be operated in series, as shown in the table. This means that each installation can be precisely tailored to the specific heat output required. The boiler is highly efficient over the entire power range, and changes in output are achieved in just a few seconds. 4

Optimum iq Innovation Minimum emissions + Clean burning - barely measurable emissions By combining an innovative partition burner with a modern lambda sensor a highly efficient and very clean combustion is achieved. The current test results under EN 303-5:2012 (shown below) demonstrate the clean and nearly dust-free combustion. The Optimum iq wood pellet boilers meet the strict requirements of the HETAS / MCS Scheme as well as the requirements of the Renewable Heat Incentive (RHI). The emissions are significantly under the RHI limits (particulate matter levels by up to 70 % and the CO emissions by up to 94.5 % below) Output Combustion efficiency CO Dust 4,7 kw 97,9 % 67 mg/m³ 7 mg/m³ 15,6 kw 95,8 % 22 mg/m³ 6 mg/m³ 20,0 kw 95,2 % 38 mg/m³ 8 mg/m³ 30,0 kw 93,8 % 86 mg/m³ 13 mg/m³ Comparison of dust emissions at rated power In accordance with the Federation Pollution Control Act, Part 2 (1-1-2015), max 20mg/m³ Source: Market Overview 2014 pellet magazine, manufacturer DE, AT 15kW 5

Automatic Cleaning For easy operation Automatic heat exchanger cleaning 16 cleaning feathers, also called turbulators, clean the entire heat exchanger automatically up to twice daily. This ensures that the long term efficiency of the boiler remains high, making automatic cleaning of the heat exchanger surfaces particularly important. The heat exchanger cleaning function is continuously monitored, with a sensor providing feedback to ensure safe operation. Automatic burner cleaning The programmable automatic burner cleaning flaps allow easy operation of the iq 3.0. The cleaning cycle is adjustable according to use or pellet quality. Regular automatic cleaning can be set to a specified time interval. For maintenance purposes the cleanout process can be activated at the press of a button. The entire cleaning process is controlled and monitored by a Belimo MP bus, with a permanent feedback status. This system allows for a cleaning condition assessment which produces a warning message when maintenance is necessary. 6

The Inner Workings With quality assured iq Touchpanel with Internet Remote Control Automatic heat exchanger cleaning system 100 mm Insulation 230L / 160kg pellet fuel store Dosing Auger Burn back protection M-Bus emetering Stoker Auger Tubular heat exchanger with spiral Turbulators and cleaning springs High efficiency heat exchanger Stainless Steel chamber tube Variable 3-way Valve IQ Partition Burner (patented) Electronic boards Automatic pellet burner cleaning system Large 26L Ash Box 20mm interior insulation 75mm boiler door insulation High-tech and German engineering The Optimum iq 3.0 offers a top class product at a very attractive price, produced by a company with 20 years' experience. Our quality assurance; we use only high quality, and thus durable, components from well-known manufacturers. 7

Fingertip Control Local and remote operation The iqtouch control management system enables the boiler to be controlled easily and optimally. Its user-friendly 16.5cm (6.5") colour touch-control panel displays heating system schematics, and provides information including: Operation and efficiency values Statistics on wood pellet consumption Fuel and Ash level Not only will iqtouch control and monitor the boiler, associated systems can also be controlled, including heating circuits, domestic hot water, buffer management and solar thermal. The iqtouch data can also be viewed remotely on a smartphone, tablet or PC which means that the heating system can be controlled from anywhere in the world. ipad/tablet Smartphone Internet Browser 8

Pellet Storage Easier than you might think The Optimum iq boiler can be fuelled by hand or automatically using a suction mole or extraction auger. The pellets can be stored in a convenient location up to 25 metres from the boiler, in a pellet tank, bunker room or other storage facility. Pellet mole Pellet extraction auger Pellet mole tank 9

Boiler Dimensions 10

Technical data Pellet biomass boiler: iq 3.0-150 iq 3.0-200 iq 3.0-270 Rated power (maximum heat output) : Minimum heat output Exhaust gas temperature Qnom Exhaust gas temperature Qmin Exhaust gas mass flow Qnom Exhaust gas mass flow Qmin Co 2 partial load (Vol%) Co 2 rated load (Vol%) Draught ignition / partial load Draught rated load Connecting flue pipe dimension: Flow and return connection: Security group, drain: Boiler (heating) water content: Elect. connection requirements: Electrical power ignition: Elect. Power consumption: Dimensions approx. (WxDxH) Weight: Overall / boiler: Fuel pellets ENplus A1, Ash melting temperature CE conformity (machinery, low voltage, EMC) Tested in accordance with: EN 303-5: 2013 15,6 kw 4,7 kw 100,0 C 63,2 C 12,2 g/s 4,6 g/s 14,5 Vol% 14,3 Vol% 4 Pa 5 Pa 125 mm IG 1 IG 3/4 55 litre 230 V, 50 Hz 200 Watt 82 Watt 133x102x155 cm 450 / 300 kg 6 mm Pellets, > 1.300 C 20,0 kw 4,7 kw 110,8 C 63,2 C 14,2 g/s 4,6 g/s 14,5 Vol% 14,2 Vol% 4 Pa 5 Pa 125 mm IG 1 IG 3/4 55 litre 230 V, 50 Hz 200 Watt 113 Watt 133x102x155 cm 450 / 300 kg 6 mm Pellets, > 1.300 C 30,0 kw 4,7 kw 135,3 C 63,2 C 16,4 g/s 4,6 g/s 14,5 Vol% 14,1 Vol% 4 Pa 6 Pa 125 mm IG 1 IG 3/4 55 litre 230 V, 50 Hz 200 Watt 184 Watt 133x102x155 cm 450 / 300 kg 6 mm Pellets, > 1.300 C Installation Diagram Green area = required access for maintenance to left and rear. 834 680 756 942 Buffer vessel Ø 100cm The system can be located with the right hand side flush to a wall. Minimum ceiling height for installation is 1.85 m. Please note required dimensions for installation of the buffer vessel. Technical specifications subject to change. 11

Benefits of the Optimum iq 3.0 A very large power output range Highest efficiency Barely measurable emissions Simple touch panel controls Remote maintenance included For more information visit our website at: Or call us on: +44 16 72 / 50 20 20 The Rural Development Programme for (RDPE) is funded by Defra and the European Agricultural Fund for Rural (EAFRD): Europe investing in rural For further information, please contact your local distributor: Optimum Heat (Southern) Ltd. 23 Wessex Park Bancombe Road Trading Estate Somerton TA11 6SB Phone: +44 (0)1672 / 50 20 20 Internet: Issue 1.1 - iq 3.0 Publisher & Copyright Holder: SOLARvent Biomasse-Heizsysteme GmbH, 37581 Bad Gandersheim 12