DPI 260 SERIES: Digital Pressure Indicators



Similar documents
Digital Pressure Measuring Instrument MDR480

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

PIEZOMETER AIRFLOW MEASURING RING

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

DC Electronic Loads 8500 series

Wahl C50 Calibrator FEATURES

Druck DPI 142/150. GE Infrastructure Sensing. Pressure Indicator Calibration manual - K382

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Multi-Range Programmable DC Power Supplies 9115 Series

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

PRODUCT PROFILE FEATURES

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Electronic Pressure Switch EDS 3000

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Contents. Document information

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Quick Connect. quick - simple - efficient.

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Electronic Pressure Switch EDS 300

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

The PACE5000 Modular Pressure Controller/Indicator

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Multi-Range Programmable DC Power Supplies 9115 Series

Features, Benefits, and Operation

PACE1000 Precision Pressure Indicator

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

UNIK Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. Expertise

FREQUENCY RESPONSE ANALYZERS

Pressure Transducer to ADC Application

Physical Specifications (Custom design available.)

T0118 T2118 T3118. Instruction Manual

Harris IRT Enterprises Digital Resistance Tester Model XR

Unidirectional Transmitter/ Receiver Units Introduction

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

MicroMachined Silicon modular pressure sensor

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Measurement & Control. Features. Applications. High accuracy. Bore hole monitoring

Typical Aluminum GFM Mass Flow Meter

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

PACE1001 Barometer Precision Barometric Indicator and Recorder

Signal Conditioning Amplifier System

Rackmount Intelligent Pressure Scanners

MODEL 1211 CURRENT PREAMPLEFIER

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Pressure transmitter For general industrial applications Model A-10

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Precision Pressure Indicator Model CPG2500

The Do s and Don ts of Pressure Transducers

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

KNC Model 3666 Automatic Pressure Calibration System

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Centro-Matic Automatic Lubrication Systems System Controls

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Measuring Temperature withthermistors a Tutorial David Potter

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

PTU Series Transducer Digital Display Indicator User s Manual

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Nokeval. User's Manual Models 301 / 302 / 305

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

1.44 kw Programmable DC Power Supplies XLN Series

FREJA 300 Relay Testing System

THE STRAIN GAGE PRESSURE TRANSDUCER

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Duct Humidity Transmitter

DCS Series 1 kw, 1.2 kw, & 3 kw

Application Note 142 August New Linear Regulators Solve Old Problems AN142-1

Sanitary Type Electronic Flow Switches

Electronic Pressure Switches

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

Section 3. Sensor to ADC Design Example

9000 Series Accelerometers Specifications

GT Sensors Precision Gear Tooth and Encoder Sensors

NC-12 Modbus Application

Conductive Level Switch FK 2 Technical Data:

Electronic Flow Switches

! Ranges 0 to 2.5 mbar through to 700 bar. ! Accuracy 0.025% FS all ranges. ! Integral combined pressure/vacuum pump. !

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Low Cost, Precision IC Temperature Transducer AD592*

MAGTROL. DSP6001 High-Speed Programmable Dynamometer Controller. DSP6001 Data Sheet FEATURES APPLICATIONS MOTOR TESTING SOFTWARE DESCRIPTION

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

O C M III. Open Channel Flow Monitor

Experiment 5. Strain Gage Measurements

Hand-held thermometer Model CTH7000

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Transcription:

DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies of ± 0.1% F.S. or ± 0.04% F.S. The DPI 265/ 266 and 267 digital pressure monitors provide additional features of alarm trips, peak hold etc. The instruments utilize the proven Druck range of pressure transducers for the DPI 260 and 261 and the pressure transmitters for the DPI 262. The Druck sensors feature excellent linearity and hysteresis and good long term stability. The transducers can be installed either internally or externally. Transmitters are remotely mounted and can often be situated at the pressure source. The pressure range covered by the instrument extends from 1 psi to 10000 psi gauge, differential or absolute. These accurate instruments provide competitive alternatives to conventional analog dial gauges and manometers and offer the advantage of clear, unambiguous digital readout. BCD and analog outputs are also available. The digital readout and electronics are purpose-designed for interfacing with the transducers or the transmitters. This is a 4 1 / 2 digit, LED display is capable of providing ± 19999 for the full-scale pressure readout giving a resolution of 0.005%. Transducers and transmitters can be matched to the instrument to provide a required pressure readout by adjusting zero/span pots and internal switches. The DPI 260 series electronics contain an extremely stable polarizing supply, signal conditioning and amplifier system which does not degrade the transducer specification. The DPI 261 can be specified with a ± 0.04% F.S. linearity, hysteresis and repeatability tolerance. This is achieved by employing electronic linearization enhancement techniques to further improve the excellent characteristics of the transducer. In addition the temperature compensation is improved providing a figure, for sensitivity, of better than ± 0.0025% of reading/ 0 F. The DPI 262 digital pressure indicator is specially configured for use with 4-20mA transmitter outputs. Any of the Druck series of PTX pressure transmitters can be used with the DPI 262, with the exception of the PTX 200 which is a 3 terminal device. The transmitters are always mounted remote to the indicator and connected via a cable. The user can confidently use the high level analog output, BCD outputs or RS232 available for accurate recordings on other data collection equipment, knowing that the fundamental pressure data is to an extremely high order of accuracy. The instrument case is a compact, rugged, purpose molded ABS shell designed to fit a standard DIN panel cut-out (3.6 x 1.8 ins). The panel instruments are suitable for easy mounting and are secured by case side fixings from the front panel. The DPI 265, 266 and 267 have the same standard specifications as the DPI 260, 261 and 262, but with additional facilities that include alarm levels, peak reading and RS232 output. The case size BASIC increases INSTRUMENT to the DIN standard ( x ins). This self-contained, strain gauge indicator can be used in conjunction with other sensors for the display of parameters such as force, displacement, load, liquid levels and strain. The user can interface this instrument to his own sensor and calibrate as required. DPI 260-4/93 2

DPI 260 SERIES: Specification DPI 260 INDICATOR The DPI 260 is a general purpose 4 1 / 2 digit LED strain gauge bridge indicator, capable of indicating 19999 maximum full scale for a wide range of input millivolts. A second order linearization control is included to improve transducer performance (DPI 261/266). For applications requiring full-scale engineering units less than 19999, the overload indication (flashing zeros) can be made to occur at any pre-set value. The zero reading can be suppressed or elevated up to ± 19999. The coarse gain, zero and decimal point selection are all achievable by internal switches making the instrument easy to reprogram in the field. The standard transducer excitation supply can be selected to either 5 or 10 volts by means of links and will supply 350 ohm bridges. A wide variety of options area available such as external d.c. power supplied, BCD output, analog output (volts or ma adjustable gain and offset). Standard Specification Readout ± 19999. Display 0.3 inch seven segment LED. Display Overload Settable anywhere between 1999 and 19999 to provide flashing 0000. Resolution 0.005% F.S. maximum. Response 333 msec to full-scale on digital display and BCD output. Zero and Sensitivity Control Front panel trim adjustments. Temperature Performance Over the range 50 to 85 F (10 0 to 30 0 C) Sensitivity Temperature Coefficient <0.0025% of reading/ 0 F Zero Offset Temperature Coefficient <0.0015% F.S./ 0 F (ref. to 50mV input - 5V common mode) Zero suppression temperature coefficient <0.0025% of reading/ 0 F Long Term Stability Zero offset <0.02% F.S. per year Sensitivity <0.02% F.S. per year Position Effect Negligible. Electrical Specification Excitation Voltages 5 or 10 Volts into 350 ohm bridge minimum (DPI 260/265, 261/266). 17.5 to 30 volts (not selectable) at 20mA for transmitter (DPI 262/ 267). Loop Voltage Drop 2V at 20mA (100 Ohm) DPI 262/267 Input Signal Range 10 to 200mV nominal for 19999 maximum display (DPI 260/265, 261/266). 16mA nominal for 19999 maximum display (DPI 262/267). Zero Suppression/Elevation Capable of ± 19999 by internal switch setting. Linearization Square law ± 1% maximum at 100mV input (DPI 261/266). Power Supplies 110V or 240V, 50-400Hz at 3VA max. Link selectable. See options for alternative supplies. Output Options A range of both digital and analogue outputs are available. Please refer to the Options section. Analog Output Options This multi-function board is configured by a link and resistor choice to give either a buffered 0 to 10 V (max) output or 4-20mA output; with zero suppression/elevation also being available. This 4-20mA can be configured either as passive sink or to power the loop with 20 volts (± 0.5V). Under any configuration the following applies; Zero rationalization <± 0.3% F.S. * Gain rationalization <0.1% F.S. Bandwidth 2KHz In-band noise <0.02% F.S. pk-pk. Zero offset temperature coefficient <0.002% of reading/ F * Gain temperature coefficient <0.0025% of reading/ F Zero suppression temperature coefficient <0.0025% of reading/ F * Gain errors do not apply to 0 to 2V output which is a unity gain buffer. Environmental Specification Temperature Operating 32 to 122 F (0 to 50 C) Calibrated 50 to 86 F (10 to 30 C) Storage -5 to +158 F ( 20 to +70 C) Physical Specification Weight 1.1 lbs (DPI 260 series). 1.7 lbs (DPI 265 series). Dimensions ins. (wide) x 1.89 ins. (high) x 6.89 ins. (deep) - DPI 260/261/262 ins. (wide) x ins. (high) x 6.89 ins. (deep) - DPI 265/266/267 Remote Connections Transducer or transmitter electrical connections available via connector on rear panel. REMOTE DRUCK PTX PRESSURE TRANSMITTER (DPI 262 ONLY) PRESS URE SOURC E REMOTE TRANSDUCER (OPTIONAL) L.E.D. DISPLAY INTEGRAL TRANSDUCER 100Ω (262 VERSION AMPLIFIER SCALING UNIT A.D. C. ONLY) POWER SUPPLIES LINEARIZATIO N UNIT BUFFER ED B C D OUTPUT +15v 15v +5v BUFFRE ED ANALOG OUTPUT +240v D.C FOR CURRENT LOOP POWE R ISOLATING TRANSFOR 110v 60Hz SUPPLI MER ES DPI 260-4/93 3

DPI 260: Specification DPI 260 Integral Transducer Specification 0-1 psi to 0-900 psi gauge 0-1 psi to 0-500 psi differential (Maximum line pressure 30 psi.) For higher line pressure, vacuum and compound ranges, refer to manufacturer. 0-5 psi to 0-900 psi absolute Barometric range version:- 11.5 psi to 17 psi absolute. ins. Hg, ins. H 2 O, Kpa, mbar, etc. The rated pressure can be exceeded by the following multiples causing negligible calibration changes:- 10 x for 1 psi to 2.5 psi ranges 6 x for 2.5 psi to 5 psi ranges 4 x 5 psi to 900 psi ranges 900 psi and above refer to manufacturer. Positive Pressure Media Reference Pressure Media Dry, non-corrosive, non-conducting gases. For liquid pressure media on reference, refer to remote transducer selection. Pressure Connections (integral) 1 / 8 NPT male Others available on request (via adapter). Remote Transducer Specification 0-1 psi to 0-900 psi gauge 0-1 psi to 0-500 psi wet/dry differential 0-2.5 psi to 0-500 psi bar wet/wet differential (Maximum line pressure 500 psi) 1000 psi line pressure available on request. 0-5 psi to 0-10000 psi sealed gauge or absolute inh 2 O, inhg, Kpa, mbar, etc. Transducer Selection Please note the following:- Gauge PDCR 800/900 series Absolute PDCR 900/series Wet/dry differential PDCR 920 Wet/wet differential PDCR 2100 series Depth measurement PDCR 830/930 Please refer to the relevant transducer data sheets for other types and specification Please refer to the relevant transducer data sheet. Pressure Media Electrical Connections Connector supplied with remote transducer and 6 ft. of cable. Pin 1 Supply positive Pin 2 Output positive Pin 3 Output negative Pint 4 Supply negative Pin 5 Screen Pin 6 Sense Longer lengths available on request. Pressure Measurement Specification Integral/external transducers. Combined non-linearity, hysteresis and repeatability. ± 0.08% F.S. for 1 psi to 500 psi ± 0.1% F.S. for 501 psi to 900 psi ± 0.15% F.S. for 901 psi to 10000 psi (with external transducer) ±0.6% F.S. available for ranges to 300 psi on request. Please refer to manufacturer. direction only, unless otherwise specified. For bi-directional calibration, quoted accuracies are in one direction only. Temperature Effects Integral transducers ± 0.5% total error band 32 to 122 F. For remote transducers operating over wider temperature ranges refer to the relevant transducer data sheet for temperature effects. DPI 261 Specification identical to DPI 260 except:- ± 0.04% F.S. for 1 psi to 500 psi ± 0.06% F.S. for 501 psi to 900 psi ± 0.1% F.S. for 901 to 10000 psi (with external transducer) Better accuracies are available on request. direction only unless specified otherwise. Calibrated Temperature Range 50 to 86 F Thermal Sensitivity Effects <0.0025% of reading / F to 900 psi <0.01% of reading / F above 900 psi The temperature coefficient also applies to remote transducers. DPI 262 Remote Transmitter Specification See the relevant data sheet for specification This instrument is suitable for use with all Druck pressure transmitters with the exception of the PTX 200. Other 4-20mA two wire transmitters can also be interfaced. 0-1 psi to 0-880 psi gauge 0-5 psi to 0-10000 psi sealed gauge or absolute 0-2.5 psi to 0-500 psi wet/wet differential (Maximum line pressure 500 psi) 1000 psi line pressure available on request. Sealed gauge not available below 500 psi. inhg, inh 2 O, KPa, mbar, etc. Transmitter Selection Please note the following:- Gauge, sealed gauge or absolute - PTX 500/600 series Wet/wet differential - PTX 120/WL Depth measurement - PTX 161/D PTX 164/165 Please refer to the relevant transmitter data sheets for other types and specification Please refer to the relevant transmitter data sheet. Pressure Media Electrical Connection Connector supplied with remote transmitter and 6 ft. of cable. Pin 1 Supply positive Pin 2 Supply negative Pin 6 Screen Longer lengths available on request. Pressure Measurement Specification Combined non-linearity, hysteresis and repeatability. ± 0.1% F.S. for 1 psi to 10000 psi ranges. ± 0.3% F.S. for 1 psi to 10000 psi ranges. (PTX 500 only). ± 0.06% F.S. available for ranges to 300 psi on request. Please refer to manufacturer. direction only. Temperature Effects Refer to the relevant transmitter data sheet for temperature effects. DPI 265/266/267 The description of the DPI 260, 261 and 262 instruments is applicable to the enhanced options instruments the 265/266 and 267. For example, if the characteristics of the DPI 260 are required but the added facilities of alarm levels, peak hold or RS232 are also needed then the unit to specify will be the DPI 265. For further details of the special features of the DPI 265 series, e.g. RS232, peak hold, alarms etc, see following page. DPI 260-4/93 4

DPI 265 SERIES: Specification DPI 265/266/267 The DPI 265/266 and 267 provide the additional enhanced features of alarm levels, peak reading and RS 232 output. This range of instruments is housed in a larger x inches enclosure and the various settings and command instructions are via the panel membrane keyboard. All the specification details describing the DPI 260, 261 and 262 still apply since the instruments are effectively incorporated into the DPI 265, 266 and 267 respectively. These additional features allow extra applications to be addressed such as safety monitoring, tank filling, maximum failure pressure recording and central reporting to computer systems. Features Instruments are supplied with all the following features:- Alarm/Trip Levels Two independent trip levels are available. Each trip level can be set anywhere over the 0-100% F.S. value. Each trip level has in turn its own adjustable re-set or hysteresis value settable anywhere over the 0-100% F.S. providing, if required, a latched output. All the settings are carried out from the front panel membrane key-pad. Relay contacts are provided with 5A/220V capability. Peak Reading As an alternative to displaying the current pressure value, the maximum and minimum pressure excursions experienced over a period of time can be displayed. A press key is provided which on the first press displays the highest pressure value experienced. Repressing this key changes the display to the lowest pressure value experienced. To cancel either the maximum or minimum current value, press the! key. Pressing the set-up key returns the display to current value monitoring. The peak value is that sampled over the digital update period of 333mS. Hold Facility To freeze the display, press the HOLD key. The displayed value will then remain unchanged by further updates. Re-pressing this key will cancel the HOLD function and normal updates will resume. Print Key With an RS232 compatible printer connected to the interface, depressing this key outputs a single displayed value reading. Using of this key, in conjunction with this set-up facility, enables the Baud rate to be selected and, if required, carriage return/line feed/function. RS232 Interface In addition to providing a valuable pressure value transmission interface to a remote computer system, it is also possible to utilize this interface to remotely program the instrument. The RS232 interface can then be used to remotely set and read trip levels, read peak values and re-set trip levels, interrupts, lock-out or enable the keyboard, read key-press actions and provide usual device clear commands. Several instruments can be operated on the same interface connected in a Daisy Chain or network fashion, each being independently addressable. DPI 260 with remote transducer DPI 261 with integral transducer DPI 265/266/267 monitor DPI 262 with remote transducer DPI 260-4/93 5

DPI 260 SERIES: Digital Pressure Indicator OPTIONS (A) Buffered BCD Parallel Output. Full parallel, buffered, TTL compatible output with data valid signal, 10 msec data invalid period during update (DV=0). Display or output hold available. (B) Buffered BCD Multiplexed Output Four wire multiplexed data bus with TTL level and tri-state control, four bits parallel to indicate value and sequential digit transmission, with the digit address provided by a further 4 bits. Synchronised to data clock or can be continuously decoded. Display hold also available. (C) Buffered Analog Output 2V related to 19999. 0 to ± 2V relating to 0 to ± 19999 display, set to ± 0.3% F.S. zero rationalization with 2mA drive capability. (D) Buffered Analog Output scaled above 2.5 psi 0 to ± 10V relative to any scale value set to ± 0.3% F.S. zero rationalization and ± 0.1% gain rationalization with 2mA drive capability. (E) Current Output passive sink. 4-20mA representing 0-100% F.S. positive pressure read-out when powered by externally energized supply (this option allows the instrument to emulate a pressure transmitter). (F) Current Output with Loop Power. 4-20mA representing 0-100% F.S. positive pressure readout and providing energizing loop voltage of 20 volts nominal. (Loop voltage + 15V with option (H). (G) 12V d.c. Operation External 12V d.c. operation at 300mA max. If requesting the 12V d.c. option the instrument will not operate directly from a 110V or 240V power supply. (H) 28V d.c. Operation External 28V d.c. operation at 300mA max. If requesting the 28V d.c. option, the instrument will not operate directly from a 110V or 240V power supply. ACCESSORIES Power cord, options connector, five point calibration certificate and instruction manual supplied with instrument. ORDERING INFORMATION If required, the basic instrument can be ordered without transducer or calibration. Please refer to price list. Please state the following:- (1) Type number. (2) Pressure range and scaling factor. (3) Gauge, differential or absolute. N.B. Line pressure for differential range. (4) Integral or remote transducer. For remote transducer see relevant transducer data sheet for ordering information. (5) Temperature range for remote transducer. (6) Pressure connection. (7) Pressure media. (8) Power supplies. (9) Options. For non-standard requirements please specify in detail. Continuing development sometimes necessitates specification changes without notice. DIGITAL INSTRUMENTS Druck manufactures a comprehensive range of pressure indicators, controllers and calibrators. Please refer to manufacturer for further information and data sheets. CALIBRATION STANDARDS Instruments manufactured by Druck Inc. are calibrated against precision pressure calibration equipment which is traceable to the National Institute of Standards and Technology (NIST). INSTALLATION DRAWINGS Dimensions: inches FRONT REAR FRONT REAR 4.10 4.10 Pressure Indicator 1.89 1.73 SPAN 260 CONTROL ZERO CUT-OUT SIZE FOR PANEL MOUNTING CONTROL 3.6 X 1.8 DEPTH OF BOTH UNITS: 6.89 265 POWER CORD CUT-OUT SIZE FOR PANEL MOUNTING OUTPUT CONNECTION (OPTIONAL) 3.6 X 3.6 REFERENCE CONNECTION (IF DIFFERENTIAL) PRESSURE CONNECTION PRESSURE CONNECTION OUTPUT CONNECTION (OPTIONAL) REFERENCE CONNECTION (IF DIFFERENTIAL) POWER CORD RS 232 OUTPUT CONNECTION cd Representative: DPI 260-4/93 6