EXPANSION AUTOMATS. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA.



Similar documents
EXPANSION AUTOMATS. Flamco. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA. Flamco Edition / EXP

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

Flamco. Flexcon M. Installation and operating instructions Flamco

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S.

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Flamco Diaphragm pressure expansion vessels

Electric Flow Boiler

Flamco Stainless steel mountings

Technical data. Danfoss DHP-A

PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Operation & Maintenance Manual

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Designed for multi-injector endurance testing, the

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

TIMER CONTROLLED DRAINS

Hydraulic Control Solutions

KNC Model 3666 Automatic Pressure Calibration System

Conlift1, Conlift2, Conlift2 ph+

Kompressoren. Adsorption Dryer AD

ECOCIAT. Domestic hot water heat recovery unit

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

Vacuum drying oven for non-flammable solvents

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

MFP14, MFP14S and MFP14SS Automatic Pumps

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

VDL 53 - Vacuum drying oven for flammable solvents

WHOLESALE DIRECT INC WEST 65TH STREET

Rotary screw compressors kw 5,5 7, , bar MODULO

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Electro-Pneumatic Bus Door Control Mechanism

Adsorption air dryers ADS 1 215

FLASH TANK ECONOMIZER PRODUCT GUIDE

Venting Range and Air/Dirt Separators

ThermoSorb Desiccant Dryers

Operators manual Basic water heater

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

Water make-up systems & water treatment technology

Heating and Hot Water Services Controls General Technical Specification

Power consumption (kw)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Workshop Compressors CLASSIC Series

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Cooking at the Speed of light!

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Portable Air Conditioner

Duplex Filters 40 FLDK 0008(C)-0120(C)

User manual. Solid (FR 98,),

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

swimming pool accessories

SunMaxx Solar Filling Station Operating Instructions

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Installation and maintenance instructions. Danfoss Vent

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

Magnum Mobile Generator MMG55 Specifications

FIREDEX Conventional Fire Panels

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

Sigma Control PC INSIDE. 97 psi 187 F R on load

Freezers - Ultrafreezers. Platilab & Irilab Series

Digital inductive conductivity transmitter

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

SF15K SF05KSS, SF10KSS

BERMAD Fire Protection

Repeaters and Mimics Data Sheet

TMS TANK MANAGEMENT SYSTEM

Centro-Matic Automatic Lubrication Systems System Controls

User manual. 086U6297 Rev. 9 EN

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Steam System Best Practices Condensate System Piping

Flamco. Flamco. Flamco. Venting range and dirt separators FLEXVENT FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S

Overheating limit control

VOYAGER 570G. 744A Sprayer Control

LABOKLAV. Autoclaves Made in Germany.

Direct steam injection humidifiers

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

AL-System 6 AQUALOOP System 6. Installation and operating instructions WATER IS OUR ELEMENT.

LK Electric Boiler - 4,5

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

HYDROSTATIC TEST PUMPS

Diagram of components 2. Reducer..3

Condensing unit type EPSILON-ECHOS LE Technical information manual

Check Valves & Actuated Valves

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

A Practical Guide to Free Energy Devices

1. Description. 2. List of Accessories included A B C F G H

Valve systems Base plates, according to standard ISO Brochure

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Kemppi Mastertig MLS 2500 and Welding Versatility for Professionals

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Oil, Gas and Dual Fuel Burners

Transcription:

EXPANSION AUTOMATS 2 Flamco Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA 2007 edition / UK

Flexcon M-K, the powerful compressor expan Flexcon M-K automats consist of a steel vessel with exchangeable diaphragm made of butyl rubber and a control unit with compressor. They are used for storing expansion volume in closed heating, cooling and air-conditioning installations. A Flexvent Super air vent is an optional extra. Quick-release couplings for auxiliary vessels. Pressure-pipe connections for maintaining pressure and pressure sensor. The Flexcon M-K compressor expansion automats store the expansion water in the installation. They also keep the set system pressure at a balanced level within close limits. Water and compressed air are separated from each other by an exchangeable diaphragm made of high-quality butyl rubber. Control panel. Steel vessel. Capacity sensor cable. Capacity and pressure sensor. The foot is adjustable in height, so that the vessel can be leveled on any surface. FLEXCON M-K/S ADVANTAGES: Extensive range of models and versions. Simple and cost-effective installation. Freely-programmable operation data. I m glad I only work with Flamco expansion automats. They are the best of their kind in terms of use, reliability and service! 2.2

sion automat The microprocessor-controlled control unit of the Flexcon M-K expansion automat has a number of easily programmable working variables. Typical to the Flexcon M-K are the reliability and strength. With the range of sizes and optional extras, the automats can be used in very different installations. The automats are fitted with low-noise, oil-free compressors which require no special maintenance. FLEXCON M-K/U Pressure-maintaining connection assembly (pressure-relief valve, discharge valve, nonreturn valve). The SDS control unit s display, also used on the Flexcon M-K/U, allows the user to see clearly what the pre-set parameters are, what the automat is doing and what the current filling level and system pressure are. These last two values can also be accessed remotely by means of module 33 (see page 15). Compressor 1. Diaphragm-rupture sensor (not supplied). Compressor 2 (optional). Exchangeable diaphragm made of high-quality butyl rubber. Foot-height adjuster. Solenoid valve opens. Solenoid valve closes. Compressor off. Compressor on. appr. 0.1 bar appr. 0.1 bar appr. 0.2 bar 2.3

Tomorrow s technology in the Flamcomat of The Flamcomat is a modern, pump-driven pressure-expansion automat which is easy to install and operate. Thanks to its elegant design, we have made it possible to incorporate lots of important functions into one compact unit. Flexvent Super air vent with air inlet preventer. Pressureless steel vessel. Flexible hoses (essential). The Flamcomat is suitable for both medium-sized and large heating installations, for both cooling and air-conditioning installations. The Flamcomat ensures that the system pressure remains balanced within close limits and that the system is topped-up automatically should there be any leakage. The venting process is at the same time dynamic and energy-efficient. User-friendly control panel. High-quality pump set. Top-up connection (225D-SDS). ADVANTAGES: The Flamcomat combines balanced pressure, dynamic de-aeration and top up interface in one package. Choice of pump modules in both single and twin versions. Vessel capacity ranging from 150 10,000 litres (both as master vessels and auxiliary vessels). Expansion water is stored (not at pressure) in an exchangeable butyl-rubber diaphragm. Use of patented PALL-rings to separate micro-airbubbles from the system. 2.4

today The Flamcomat consists of a pre-configured pump unit and a pressureless master vessel. This pressure-expansion system can be enhanced with accessories from our extensive range. In this way, you can tailor the equipment precisely to the needs of your installation. Atmospheric connection for pressure compensation in the space between the interior wall of the vessel and the exterior wall of the diaphragm. Exchangeable diaphragm made of high-quality butyl rubber. FLAMCOMAT By using integrated PALL-rings, you can separate air from the installation continuously and completely. The turbovent function significantly increases the de-aeration ability over a short time. Oxygenated water from the installation. De-aerated water fed back into the installation. PALL-RINGS Pump pressure pipe, from pressureexpansion vessel to installation. Pressure sensor. Solenoid valve. Pressure-relief valve. Sealable drain valve. The Flamcomat is a multi-ability expansion automat with excellent technical performance. The Flamcomat s de-aeration capacity does not depend on the circulation speed or pressure within the system. When fitting an installation with significant differences between summer and winter operation, we recommend use of a doublepump (load-dependent) Flamcomat pump automat. You will find the complete installation instruction on the CD. 2.5

ENA: the modern vacuum de-aeration and pres The Flamco ENA vacuum de-aeration and pressurisation unit can be used in both closed central-heating installations and in closed cooling and air-conditioning installations. The ENA is used in combination with a Flexcon diaphragm expansion vessel or a Flexcon M-K expansion automat. The ENA s maximum working temperature is 70 C. The ENA is available in three pressure options and is easy to set up. Flexvent air vent with air intake preventer. Control panel. Vacuum tank made of stainless steel. Connection from system: 3 /4. Top-up connection: 3 /4. Connection to system: 3 /4. Pump (pumps). Skid plate. The Flamco ENA allows you to choose between turbo-vent (quick and effective, with short pauses between the vent cycles) and normal venting (an energy-efficient method). Via a volt free error function log, reports can be transferred to a building-management system (BMS). The ENA is self-monitoring due to its logic control which verifies the sensor values. Like me, all my colleagues are convinced that a Flamco installation is always the best installation. Years of experience have proved this. 2.6

surisation unit Reduced system volume is caused by air venting and leakage. The ENA s automatic top-up interlock compensates for this. This combination represents the following advantages for you: Excellent de-aeration performance. Central venting point for both the installation and the top-up water. Comes completely valved and ready for connection. Requires little room in the boiler house. ENA WITH SINGLE PUMP ENA WITH DOUBLE PUMP Installation diagram for the ENA in an installation with external control of topping-up by means of the expansion automat control unit. Malfunction log interface (RS 485) (optional) 5 p Continental (Euro) plug, CEE 250 V Pump Float switch Vacuum pressure switch 9 ENA control unit p ENA 8 7 16 1 6 3 External connection for topping-up from the automat Normally closed 14 15 Normally open ( ) Separate accessories: NFE filler unit Rp 3 /4 Rp 3 /4 0 0 0 Σ m 3 Topping-up Compressor expansion automat Legend 1. Vacuum tank. 2. Pump/(pumps). 3. Control unit. 4. Volume current limiter. 5. Pressure sensor. 6. Float switch. 7. Flexvent air vent. 8. Air inlet preventer. 9. Pressure gauge. 10. Non-return valve. 11. Solenoid valve. 12. Filter. 13. Ball valve. 14. Non-return valve. 15. Solenoid valve. 16. Vacuum pressure switch. 13 10 4 2 Rp 3 /4 4 10 11 12 13 Rp 3 /4 Installation return pipe Seal (lockable); to be fitted by the installer The control unit with control panel is ergonomically situated The ENA can be operated and programmed easily with just four keys. The way to do this is clearly described in the installation and operation instructions. You can find them on the CD. Example of the display Pressure: 3.5 bar Venting: Turbo Choice on menu Flamco Back Next ENA 2 Enter 2.7

Flexcon digital sealed system pressurisation units A series of compact fl oor and wall mounted pressurisation units utilising the latest microprocessor control. For use on sealed heating and cooling systems, offering accurate control and excellent reliability. Easy system diagnostics with detailed messages scrolled across the controller screen. FLEXCON MINI WALL MOUNTED PRESSURISATION UNIT Available in single or dual pump versions with active pump monitoring and auto changeover on the dual pump models. Other features include an internal alarm with mute function, high/low pressure alarms with adjustable setpoint (auto reset) as well as a pump run limiter with alarm (manual reset flood protection). The Flexcon pressurisation units are also equipped with a low water detection to protect the pump(s), main pressure setpoint with adjustable differential and common fault volt free contact. The controller is protected by a security password. There are volt free / powered outputs for individual pump health, high pressure, low pressure and sensor health. All volt free outputs can be powered for warning lamps and/or alarms using up to 230 V and 8 A. ADVANTAGES FLEXCON PRESSURISATION UNITS: Accurate control and excellent reliability. Simple diagnostics, auto changeover. Pump monitoring and isolation. Volt free contacts plus boiler interlock (common alarm). Incorporates A-B type air gap and break tank. Analogue type Flexcon CN for use with Flexcon expansion vessels to provide a minimum system pressure requirement. Available with various options to provide an economical alternative with no sacrifice in quality. 2.8

SDS digital pressurisation units. A series of microprocessor controlled enclosed type twin pump units for use with Flexcon constant pressure expansion equipment to provide make up water on demand. The processor allows for system logging and diagnostics. FLEXCON FLOOR STANDING PRESSURISATION UNIT The Flexcon pressurisation units offer a 4 digit bright LED display with scrolling messages including systems status and alarm modes. Digital pressurisation units including: On / off switch, with indicator neon. WRAS approved break tank. WRAS approved float valve. Constructed as type AB air gap with weir overflow, fluid category 5. Electric pump, 230 V 50 Hz single phase. Electronic pressure transducer. Normally closed, common fault, volt free boiler interlock. Normally open high pressure, low pressure, transducer health and pump health volt free contacts. System logging. Easy setup and commissioning. Acts as slave device when coupled to either a Flamcomat or an Flexcon MK/U balanced expansion equipment. RANGE 225D-SDS twin pump, 2.5 bar(g) max. delivery pressure. Suitable for all Flamcomat variations and Flexcon MK/U equipment with system pressures not exceeding 2.5 bar(g). The equipment is suitable for systems operating at pressures up to 10 bar(g). The individual SDS top-up set should be selected for the required system pressure. 250D-SDS twin pump, 5.0 bar(g) max. delivery pressure. For Flexcon MK/U equipment with system pressures between 2.5 bar(g) and 5.0 bar(g). 280D-SDS twin pump, 8.0 bar(g) max. delivery pressure. For Flexcon MK/U equipment with system pressures between 5.0 bar(g) and 9.0 bar(g). 2.9

A 300 Simple and quick installation with the Flexcon Feedboy The Flexcon Feedboy function server is suitable for medium and large heating systems and can be used in both existing and new installations. The LCD display on the control panel continuously shows a complete selfdiagnosis of the Flexcon Feedboy itself. FLEXCON M-K/S FLEXCON FEEDBOY All models of the Flexcon Feedboy are supplied as integral units. The Flexcon Feedboy is manufactured from durable materials and components; the control technology used is both user-friendly in the extreme and singularly reliable. The pressure in the installation can be set to any desired level within the range. A number of important functions are united in the Flexcon Feedboy: storage of expansion water, installation-pressure monitoring, venting and topping-up of water. This means that the unit is both compact and economical with space. It may be integrated into a buildingmanagement-system network. The expansion vessel is manufactured from stainless steel. Top-up connection. Power supply. Central heating connection to the Flexcon Feedboy. Central heating connection from the Flexcon Feedboy. Pot. free sockets and RS 485 connection for BMS systems feedboy process controller Overflow connection. THE ADVANTAGES OF THE FLEXCON FEEDBOY: C Level switch float expansion area top-up direction sewer tapwater DWL valve 2 Reliability due to the use of durable materials and low-maintenance components. Less intervention required as small errors are fixed automatically. Extra security aspect thanks to accurate monitoring. 2.10 B A B A level switches suppletion buffer ball valve pump valve 1 transmitter from central heating to

ENA vacuum de-aeration and top-up automats; Flexcon Feedboy function server Max. system pressure of ENA 1 and ENA 2 is 8 bars; ENA 3 is up to 10 bars. Versions and dimensions ENA Type System pressure System volume System connections Dimensions in mm Weight in in bars m 3 L B H kg Code number ENA 1 1.3-3.5 < 80 Rp 3 /4 710 340 1270 40 FLAMCO ENA 1 ENA 2 2.0-4.5 < 100 Rp 3 /4 740 340 1270 45 FLAMCO ENA 2 ENA 3 3.0-8.0 < 100 Rp 3 /4 710 540 1270 60 FLAMCO ENA 3 ENA Versions and dimensions Flexcon Feedboy function servers Type Capacity in litres Dimensions in mm Weight in L B H kg Code number Flexcon Feedboy 600/A 600 850 1070 1700 145 FCFBOY 600/A Flexcon Feedboy 600/B 600 850 1070 1700 145 FCFBOY 600/B Flexcon Feedboy 600/C 600 850 1070 1700 145 FCFBOY 600/C Flexcon Feedboy 600/ 600 850 1070 1700 145 FCFBOY 600/ H Flexcon Feedboy 1000/A 1000 1050 1300 1700 160 FCFBOY 1000/A Flexcon Feedboy 1000/B 1000 1050 1300 1700 160 FCFBOY 1000/B Flexcon Feedboy 1000/C 1000 1050 1300 1700 160 FCFBOY 1000/C Flexcon Feedboy 1000/ 1000 1050 1300 1700 160 FCFBOY 1000/ L B FLEXCON FEEDBOY H L B 2.11

Flexcon M-K compressor expansion automats The Flexcon M-K version with SDS control unit is called Flexcon M-K/U. All Flexcon M-K automats consist of a steel master vessel, an exchangeable diaphragm made of butyl rubber, a control unit with control panel, height-adjustable feet and an oil-free compressor. All Flexcon M-K expansion automats are supplied complete and ready for connection. The Flexcon M-K auxiliary vessel does not have a control unit or compressor. If an auxiliary vessel is to be connected, it must be equivalent to the master vessel. Air-side connections between the master vessel and the auxiliary vessel must be made with a high-pressure hose. Quick-release couplings are available. Water-side connections must be made in situ. Versions and dimensions Flexcon M-K/U 6 and 10 bar Type Capacity Dimensions in mm Compressor System Weight Code number in conn. (int.) in kg litres ØD H C Ød ISO 228-1 6 bar 10 bar 6 bar 10 bar Flexcon M-K/U 400 400 750 1385 185 620 K 011 1 1 /4 165 210 23824 23864 Flexcon M-K/U 600 600 750 1805 185 620 K 011 1 1 /4 195 250 23826 23866 Flexcon M-K/U 800 800 750 2205 185 620 K 031 1 1 /4 230 300 23828 23868 Flexcon M-K/U 1000 1000 750 2760 185 620 K 031 1 1 /2 265 340 23830 23870 Flexcon M-K/U 1200 1200 1000 1990 175 850 K 031 1 1 /2 325 450 23832 23872 Flexcon M-K/U 1600 1600 1000 2490 175 850 K 031 1 1 /2 380 525 23836 23876 Flexcon M-K/U 2000 2000 1200 2230 175 1050 K 031 2 465 640 23840 23880 Flexcon M-K/U 2800 2800 1200 2830 175 1050 K 031 2 1 /2 550 765 23848 23888 Flexcon M-K/U 3500 3500 1200 3630 175 1050 K 031 2 1 /2 660 940 23855 23895 FLEXCON M-K/U Versions and dimensions Flexcon M-K auxiliary vessels 6 and 10 bar Type Capacity in litres Dimensions in mm System Weight Code number conn. (int.) in kg ØD H C Ød ISO 228-1 6 bar 10 bar 6 bar 10 bar Flexcon M-K 400 400 750 1385 185 620 1 1 /4 130 175 22040 22070 Flexcon M-K 600 600 750 1805 185 620 1 1 /4 160 215 22041 22071 Flexcon M-K 800 800 750 2205 185 620 1 1 /4 195 265 22042 22072 Flexcon M-K 1000 1000 750 2760 185 620 1 1 /2 230 305 22043 22073 Flexcon M-K 1200 1200 1000 1990 175 850 1 1 /2 290 415 22044 22074 Flexcon M-K 1600 1600 1000 2490 175 850 1 1 /2 345 490 22045 22075 Flexcon M-K 2000 2000 1200 2230 175 1050 2 430 605 22046 22076 Flexcon M-K 2800 2800 1200 2830 175 1050 2 1 /2 515 730 22048 22078 Flexcon M-K 3500 3500 1200 3630 175 1050 2 1 /2 625 905 22047 22077 H C Ø d Ø D Second compressor unit Type Suitable for Code number FLEXCON M-K Compressor K 01/K 011 Flexcon M-K/S and Flexcon M-K/U 23618 Compressor K 02 Flexcon M-K/S and Flexcon M-K/U 23619 Compressor K 03/K 031 Flexcon M-K/S and Flexcon M-K/U 23620 Compressor K 04 Flexcon M-K/S and Flexcon M-K/U 23621 The second compressor unit is fitted on a second support bracket on the expansion automat. The compressors have to be of the same type. Complete delivery and ready for connection. H Air-side connection between base vessel and auxiliary vessel Type Suitable for Code number High-pressure connection hose for 2 vessels, max. length 3 m Flexcon M-K/S and Flexcon M-K/U 22380 High-pressure connection hose for several vessels Flexcon M-K/S and Flexcon M-K/U 22381 C Adapter with flange connection PN 16 For vessel capacity (litres) Connection L Suitable for Code ext. PN16 mm number 400-800 1 1 /4 DN 32 350 Flexcon M-K/S and Flexcon M-K/U 23795 1000-1600 1 1 /2 DN 40 470 Flexcon M-K/S and Flexcon M-K/U 23796 2000-2000 2 DN 50 560 Flexcon M-K/S and Flexcon M-K/U 23797 2800-3500 2 1 /2 DN 65 560 Flexcon M-K/S and Flexcon M-K/U 23798 Ø d Ø D ADAPTER L 2.12

Flexcon M-K compressor expansion automats The Flexcon M-K/S has a freely-programmable control unit for single and multiple use as well as master slave operation. All Flexcon M-K expansion automats have a connection for a Flamco SDS top-up pressurisation unit and a remote fault alarm. The maximum diaphragm temperature for all Flexcon M-K automats is 70 C (343 K) during continuous operation. Versions and dimensions Flexcon M-K/S 6 and 10 bar Type Capacity Dimensions in mm Compressor System Weight Code number in conn. (int.) in kg litres ØD H C Ød ISO 228-1 6 bar 10 bar 6 bar 10 bar Flexcon M-K/U 400 400 750 1385 185 620 K-01 1 1 /4 156 201 22901 22950 Flexcon M-K/S 400 400 750 1385 185 620 K-02 1 1 /4 165 210 22902 22951 Flexcon M-K/S 400 400 750 1385 185 620 K-03 1 1 /4 165 210 22903 22952 Flexcon M-K/S 400 400 750 1385 185 620 K-04 1 1 /4 170 215 22906 22954 Flexcon M-K/S 600 600 750 1805 185 620 K-01 1 1 /4 186 241 22907 22955 Flexcon M-K/S 600 600 750 1805 185 620 K-02 1 1 /4 195 250 22908 22956 Flexcon M-K/S 600 600 750 1805 185 620 K-03 1 1 /4 195 250 22909 22957 Flexcon M-K/S 600 600 750 1805 185 620 K-04 1 1 /4 200 255 22911 22959 Flexcon M-K/S 800 800 750 2205 185 620 K-01 1 1 /4 221 291 22912 22960 Flexcon M-K/S 800 800 750 2205 185 620 K-02 1 1 /4 230 300 22913 22961 Flexcon M-K/S 800 800 750 2205 185 620 K-03 1 1 /4 230 300 22914 22962 Flexcon M-K/S 800 800 750 2205 185 620 K-04 1 1 /4 235 305 22916 22964 Flexcon M-K/S 1000 1000 750 2760 185 620 K-01 1 1 /2 256 331 22917 22965 Flexcon M-K/S 1000 1000 750 2760 185 620 K-02 1 1 /2 265 340 22918 22966 Flexcon M-K/S 1000 1000 750 2760 185 620 K-03 1 1 /2 265 340 22919 22967 Flexcon M-K/S 1000 1000 750 2760 185 620 K-04 1 1 /2 270 345 22921 22969 Flexcon M-K/S 1200 1200 1000 1990 175 850 K-01 1 1 /2 316 441 22922 22970 Flexcon M-K/S 1200 1200 1000 1990 175 850 K-02 1 1 /2 325 450 22923 22971 Flexcon M-K/S 1200 1200 1000 1990 175 850 K-03 1 1 /2 325 450 22924 22972 Flexcon M-K/S 1200 1200 1000 1990 175 850 K-04 1 1 /2 330 455 22926 22974 Flexcon M-K/S 1600 1600 1000 2490 175 850 K-02 1 1 /2 380 525 22928 22976 Flexcon M-K/S 1600 1600 1000 2490 175 850 K-03 1 1 /2 380 525 22929 22977 Flexcon M-K/S 1600 1600 1000 2490 175 850 K-04 1 1 /2 385 530 22931 22979 Flexcon M-K/S 2000 2000 1200 2230 175 1050 K-02 2 465 640 22933 22981 Flexcon M-K/S 2000 2000 1200 2230 175 1050 K-03 2 465 640 22934 22982 Flexcon M-K/S 2000 2000 1200 2230 175 1050 K-04 2 470 645 22936 22984 Flexcon M-K/S 2800 2800 1200 2830 175 1050 K-02 2 1 /2 550 765 22938 22986 Flexcon M-K/S 2800 2800 1200 2830 175 1050 K-03 2 1 /2 550 765 22939 22987 Flexcon M-K/S 2800 2800 1200 2830 175 1050 K-04 2 1 /2 555 770 22941 22989 Flexcon M-K/S 3500 3500 1200 3630 175 1050 K-02 2 1 /2 660 940 22943 22991 Flexcon M-K/S 3500 3500 1200 3630 175 1050 K-03 2 1 /2 660 940 22944 22992 Flexcon M-K/S 3500 3500 1200 3630 175 1050 K-04 2 1 /2 665 945 22946 22994 FLEXCON M-K/S Additional options Flexcon control unit Type Code number Easycontact 23649 Diaphragm rupture sensor 22386 SDS modules, see page 15 2.13

Flamcomat pump expansion automats and pump units, Flexcon pressurisation units The Flamcomat consists of a pressureless master vessel with integrated turbo-venting, an exchangeable diaphragm made of butyl rubber, electronic level indicator and control, height-adjustable feet as well as a Flexvent air vent with air intake preventer. The Flamcomat combines three important functions: pressure control, dynamic venting and topping-up via the 225D-SDS pressurisation unit. Max. installation pressure: 10 bar; max. equipment delivery pressure 8.5 bar. Max. diaphragm temperature: 70 C (343 K) at continuous operation. Pump units completely assembled and ready for installation. Easily-programmable control unit, made up of a power section and a control section. Versions and dimensions Flamcomat GB (master vessels) and BB (auxiliary vessels) Type Capacity Dimensions in mm Weight Code number in litres ØD H in kg GB BB Flamcomat 150 150 550 1350 55 17710 17760 Flamcomat 200 200 550 1530 70 17711 17761 Flamcomat 300 300 550 2030 90 17712 17762 Flamcomat 400 400 750 1535 130 17713 17763 Flamcomat 600 600 750 1955 160 17714 17764 Flamcomat 800 800 750 2355 195 17715 17765 Flamcomat 1000 1000 750 2855 226 17716 17766 Flamcomat 1200 1200 1000 2210 290 17717 17767 Flamcomat 1600 1600 1000 2710 345 17718 17768 Flamcomat 2000 2000 1200 2440 430 17719 17769 Flamcomat 2800 2800 1200 3040 515 17720 17770 Flamcomat 3500 3500 1200 3840 625 17721 17771 Flamcomat 5000 5000 1500 3570 1240 17722 17772 Flamcomat 6500 6500 1800 3500 1710 17723 17773 Flamcomat 8000 8000 1900 3650 1830 17724 17774 Flamcomat 10000 10000 2000 4050 2025 17725 17775 H FLAMCOMAT GB Versions and dimensions pump units Type For max. heating capacity Dimensions in mm Connection internal thread Weight in MW L B H To vessel To system To water supply kg Code number M 0 0.3-1.3 440 330 890 1 1 /4 1 1 /2 15 17786 M 1 1.0-4.0 460 380 890 1 1 /4 1 1 /2 20 17780 M 2 2.0-8.0 460 380 890 1 1 /4 1 1 /2 23 17781 M 3 1.2-4.0 410 410 915 1 1 /2 1 1 /4 1 /2 30 17784 D 0 1.3-4.4 590 500 890 1 1 /2 1 1 /4 1 /2 32 17788 D 1 2.0-8.0 590 500 890 1 1 /2 1 1 /4 1 /2 34 17782 D 2 4.0-10.0 590 500 890 1 1 /2 1 1 /4 1 /2 40 17783 D 3 2.2-8.0 560 410 915 1 1 /2 1 1 /4 1 /2 75 17785 Ø D PUMP UNITS Versions and dimensions pressurisation units Type System pressure Pump Max. working pressure Dimensions in mm System connection Weight in H L B kg Code number 130 D Flexcon Mini < 3 bar single 6 bar 460 250 160 1 /4 M 6 FC FILL 130D 230 D Flexcon Mini < 3 bar dual 6 bar 460 250 160 1 /4 M 6 FC FILL 230D 125 D Flexcon floor standing < 3 bar single 10 bar 800 480 330 1 /2 M 28 FC FILL 125D 150 D Flexcon floor standing < 6 bar single 10 bar 800 480 330 1 /2 M 28 FC FILL 150D 225 D Flexcon floor standing < 3 bar dual 10 bar 800 480 330 1 /2 M 30 FC FILL 225D 250 D Flexcon floor standing < 6 bar dual 10 bar 800 480 330 1 /2 M 30 FC FILL 250D H L PRESSURISATION UNITS B Versions and dimensions Flexcon CN Type Dimensions in mm System Weight Code H L B connection in kg number Flexcon CN 125 700 770 530 1 /2 M 22 FC CN 125 Flexcon CN 150 700 770 530 1 /2 M 24 FC CN 150 Flexcon CN 225 700 770 530 1 /2 M 26 FC CN 225 *High/low switch kits available on request. H L B 2.14

SDS modules and Flamcomat accessories A Flamcomat unit consists of a master vessel (optionally an auxiliary vessel), plus a SDS controller, pump unit, vessel connection and other accessories. Switch module and connectors with rotatable connection, sealed. Non-return valve incl. dirt trap and seal. SDS modules Type Description Suitable for Code number Flexcon Flamcomat M-K/U SDS module 31 Soft starter for pump(s) 17793 SDS module 32 Timer with week programme for optimal freedom of choice in, for instance, de-aeration cycles 17790 SDS module 33 Analogue signalling for capacity and pressure 17792 SDS module 34 Diaphragm rupture sensor 17791 SDS module 45 PA contact, for connecting a Flamco 225D-SDS top-up unit or Flamco 250D-SDS top-up unit or Flamco 280D-SDS top-up unit 17794 Easycontact 23649 Vessel connections, sealed Type Connection to Weight in Code number vessel (int.) control unit (ext.) kg Vessel connection type 5 1 1 /2 1 1 /4 0,5 17730 Vessel connection type 6 1 1 /2 1 1 /4 0,5 17731 Ball cock with blow-off valve Type Connection to Weight in kg Code number Ball cock with blow-off valve 1 ext. 0,5 17737 Ball cock with blow-off valve 1 1 /4 ext. 0,5 17738 SDS MODULE Vessel connections, sealed Ball cock with blow-off valve System divider Type Connection to Weight in Code number kg System divider (BA) 1 /2 int. - 1 /2 ext. 0,6 17737 2.15

EXPANSION AUTOMATS CONTENTS PAGE FLEXCON M-K Flexcon M-K compressor expansion automat 2.2/2.3 Flamcomat: The technology of the future 2.4/2.5 ENA de-aeration and topping-up automat 2.6/2.7 Pressurisation units 2.8/2.9 Flamco UK Limited Unit 4, St. Michael s Road Lea Green Industrial Estate St. Helens, Merseyside WA9 4WZ Tel.: +44 (0) 1744 818100 Fax: +44 (0) 1744 830400 info@flamco.co.uk www.flamco.co.uk Flexcon Feedboy function server 2.10 FLAMCOMAT Tables 2.11/2.15 You can find more information on the CD which accompanies this brochure. Copyright Flamco UK Limited. No part of this publication may be reproduced or published in any way without explicit mention of the source. The data listed are solely applicable to Flamco products. Flamco UK Limited shall accept no liability whatsoever for incorrect use, application or interpretation of the technical information. Flamco UK Limited reserves the right to make technical alterations. ENA Flamco UK Limited conditions of sale apply. 18502398