Valve range. To be precise.



Similar documents
Mikrotherm. Manual radiator valves. To be precise.

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Data sheet Thermostatic sensors type RA 2000

Thermostats. Technical information

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

HERZ-Thermal Actuators

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Low-H2O valves Y EARS

Radiator valve accessories

Globo P. Ball valves Pump ball valve made of gunmetal

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Thermostatic Actuators

Data sheet ECC 12 and 22

stainless steel pre-assembled manifolds

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

1. Geo Vertical 2. Geo Horizontal

Self-operated Temperature Regulators Temperature Regulator Type 1u

new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Technical catalogue convectors POLAND 2012

Powers Controls TH 192 S Single Temperature Room Thermostat

Please refer to the chapters below for detailed information about all aspects of the products usage.

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Brochure EX

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Radio controlled, programmable radiator thermostat RA PLUS-w

AFE424 SERVICE PARTS

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

AIR LINE VALVES AND GAUGES

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Floor Heating Warehouse.co.uk

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Frequently Asked Questions

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

» WEH HVAC-R CONNECTORS

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Thermostatic element RAVV for 2-way valves

Operators manual Basic water heater

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Description of functions

E v e r i n c r e a s i n g i n n o v a t i o n. R A R a n g e. C o m m e r c i a l T R V s

STABITHERM INSTALLATION & SERVICE BOOKLET

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Your safety and the safety of others are very important.

building engineering services association specification for: Domestic Heating

Cooling system components, removing and installing

Turbine Flow Sensor Series VTR

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Product catalogue, pipe and sewer cleaning systems

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

Cooling system components, removing and installing

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

ECOCIAT. Domestic hot water heat recovery unit

Zenith Solar thermal 4.5m pump station Installation manual

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

FOXAIR 60/50 ALL MODELS

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Laddomat Charging unit

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

HAZUBA. HAZUBA AG Rainstrasse Zuchwil T F info@hazuba.ch 06/14

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

EMERGENCY PLUMBING FIXTURES

MOUNTING AND OPERATING INSTRUCTIONS

Product and Application Description

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

swimming pool accessories

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

RADIATOR VALVE. type m72. Page 1

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Operating instructions

VOYAGER 570G. 744A Sprayer Control

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Cooling system components, servicing

RF 1. Contents: Connecting diagram. Detailed information:

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

2003 ACCORD - Automatic Transmission Removal

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

NFPA31FuelOilPiping 1 Revised

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Industrial infrared heater IR For premises with large volumes and high ceilings

Series description: Wilo-Star-Z

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Transcription:

Valve range To be precise.

Thermostatic room temperature control Thermostatic head K with built-in sensor. Graduation cap white RAL 9016, Graduation cap chrome-plated, Graduation cap anthracite grey RAL 7016, Graduation cap light grey RAL 7035 and Graduation cap dusty grey RAL 7037. Thermostatic head VD with connection cover for radiators with integrated valves, from the DESIGN LINE range. Thermostatic head WK Angle form for radiators with integrated valves. Thermostatic head VK with clamp, for radiators with integrated valves. standard with zero position with anti-theft protection Thermostatic head DX with built-in sensor. Graduation cap white RAL 9016, Graduation cap chrome-plated, Graduation cap graphite grey RAL 7024, Graduation cap light grey RAL 7035 and Graduation cap dusty grey RAL 7037. Thermostatic head B secured public building model. Thermostatic head D Thermostatic head K anti-theft ring anti-theft device with two screws with zero position for indoor swimming-pools model for public buildings Thermostatic head F Remote dial. with built-in sensor with remote sensor for indoor swimming-pools Thermostatic head K with remote sensor. anti-theft ring anti-theft device with two screws with zero position for indoor swimming-pools model for public buildings With direct connection to valves from other manufacturers K for Danfoss RAVL K for Danfoss RAV VK for Danfoss RA standard with zero position with anti-theft protection D for Danfoss RA K for Vaillant D for Herz M 28 x 1.5

Standard for two-pipe pumped heating systems. with particularly low resistance for gravity and conventional single-pipe heating systems. Body in angle, straight, axial and double-angle form, made out of gunmetal and nickel-plated. Models in DN 10 DN 32 with a female thread and DN 15 with a male thread and press connection. Can be fitted with covers from the DESIGN LINE range for angle and straight NW 10 NW 15 with female thread. Duolux Valve for radiators with lateral two-point connection. Models for single and two-pipe systems. E-Z Valve including immersion pipe for radiators with bottom single-point connection. Models for single and two-pipe systems. Body made of gunmetal, nickel-plated. Single pipe valve with immersion pipe for radiators with a lateral single-point connection. V-exakt with exact pre-setting for heating systems with a normal to higher temperature spread. F-exakt with exact pre-setting for heating systems with low mass flows or large-scale temperature spreads, e.g. for remote heating systems. Body in angled, straight, axial and doubleangle form, made out of gunmetal and nickelplated. Models in DN 10 DN 20 with a female thread and DN 15 with a male thread and press connection. Can be fitted with covers from the DESIGN-LINE range for angle and straight NW 10 NW 15 with female thread. E-Z System Valve for radiators with lateral two-point connection. Can be changed from single-pipe to two-pipe operation. Body made of gunmetal, nickelplated. Multilux for radiators with low-positioned, two-point connection, distance from center to center 50 mm. For pre-setting and draining. Available in angle and straight models for both single and two-pipe systems. Connection R 1 /2 and G 3 /4. Can be fitted with covers from the DESIGN LINE range in white and chrome.

Electric/electronic room temperature control Time Adaptor Room temperature controllers Radio system for floor heating system E-Pro Time Adaptor for Thermostatic Valves A time adaptor designed to regulate room temperatures in tune with specific times of the day and night. The device is fitted between the valve and the thermostatic head. HEIMEIER thermostatic heads, which are already available, can continue to be used after fitting of the time adaptor. Room thermostat Two-point room thermostat for thermal actuators EMO T/ EMOtec. Thermostat P Two-point room thermostat with 7-day switch clock for thermal actuators EMO T/EMOtec. Thermostat E 1 Proportional room thermostat for motorized actuators EMO 1. Thermostat E 3 The 3-point room thermostat for motorized actuators EMO 3. Radiocontrol F consisting of room transmitter and central unit. For the individual room temperature control of floor, wall or ceiling heating systems or cooling systems. Thermal actuators Motorized actuators Motorized actuators EMO T Two-point actuator for heating, ventilation and air-conditioning systems. EMOtec Two-point actuator for floor heating systems. With position indicator in NC version. EMO 1 Proportional actuator for heating, ventilation and air-conditioning systems. EMO 3 Three-point actuator for heating, ventilation and air-conditioning systems. EMO 3 / 230 "3-point 230 V" input signal. Ideally suited for the regulating of the supply pipe temperature. EMO EIB Proportional actuator for direct connection to the European Installation Bus EMOLON Proportional actuator for use in LonWorks networks.

Special fittings Three-way valves Three-way reversing valve for distributing flow rates in heating and cooling systems. Three-way mixing valve with and without pre-setting feature for mixing flow rates in heating and cooling systems. Body made of gunmetal. For all HEIMEIER thermostatic heads and actuators. Thermostatic head K with contact or immersion sensor Use of the sensor in conjunction with heat conducting base as a contact sensor or with an immersion sleeve as an immersion sensor. Thermostatic head with spiral-shaped immersion sensor without immersion sleeve. Sealed to the capillary tube by means of clamping joint. Floor control set for the constant control of the supply temperature in combined floor and radiator heating systems. Return temperature limiter RTL e. g. for the temperature control of smaller floor areas. Body in angle and straight versions, made of gunmetal, nickel-plated. Connection R 1 /2 and G 3 /4. Flush individual room control for floor heating systems Multibox K with thermostatic valve. Multibox RTL with return temperature limiter. Multibox K-RTL with thermostatic valve and return temperature limiter. Models in white or chrome. Multibox F with thermostatic valve. Multibox C/E with thermostatic inserts for actuators or remote dial. Multibox C/RTL with interior return temperature limiter. Models available in white. Double connection fittings for radiators with integrated valves Vekolux Double connection fitting with drain-off facility. Versions for single and two-pipe systems. Can be fitted with covers in white from the DESIGN LINE range. Vekotec Double connection fitting. Models for two-pipe systems. Body in angle and straight form and made of gunmetal, nickel-plated. Connection R 1 /2 and G 3 /4.

Manual valves Manual radiator valve Manual valves for floor heating system Mikrotherm with pre-setting. With hand wheel cap made of white plastic. Body in angle and straight form, made of gunmetal and nickel-plated. NW 10 NW 32. Manual valves and also lockshields for heating manifolds, universal connection possibilities on both sides, body made of gunmetal. Radiator lockshield Radiator lockshield Regulux for shutting off, pre-setting, draining and filling. Models in DN 10 DN 20 with a female thread and DN 15 with a male thread and press connection. Can be fitted with covers from the DESIGN LINE range for angle and straight versions NW 10 NW 15 with female thread. Regutec for shutting off and controlling. Models in DN 10 DN 20 with a female thread and DN 15 with a male thread and press connection. Can be fitted with covers from the DESIGN LINE range for angle and straight versions NW 10 NW 15.

Shut-off valves Ball valve for heating systems Pump ball valve for heating systems Drinking Water Ball Valve Globo H Body and ball made of gunmetal. Models available as DN 10 DN 50 with a female thread, DN 15 DN 40 with a onesided male thread and DN 15 32 with press connection. Thermometer in red or blue as an accessory, can be upgraded by exchanging the locking cap. Can be fitted with heat insulating shell. Globo P Globo P-S with gravity brake. Body and ball made of gunmetal Models available as 1 x 1, 1 1 /4 x1 1 /4, 1 1 /4 x 1, with 28 mm x 1 and 35 x 1 1 /4 press connections. Thermometer in red or blue as an accessory, can be upgraded by exchanging the locking cap. Can be fitted with heat insulating shell. Globo D Body and ball made of gunmetal. Models DN 15 - DN 32 with female thread and press connection. Thermometer in green as an accessory, can be upgraded by exchanging the locking cap. Can be fitted with heat insulating shell. Filling and draining ball valve Differential pressure overflow valve Globo KFE with locking cap or with threaded hose coupling and locking cap. Body made of brass and brass nickel-plated. Models ranging from NW 10 NW 20. Hydrolux Proportionally-operating differential pressure overflow valve for installation in pumped heating systems. With clearly visible display of setting values. Models with female thread or fitting ranging from NW 20 NW 32.

About us With its thermostatic valve, HEIMEIER has attained a leading position worldwide. The K head is the best-selling thermostatic head in the world. In Germany, the largest thermostatic valve market of all, almost every second thermostatic valve installed in recent years came from HEIMEIER. A great success story which began when Theodor Heimeier founded the company in the Westphalian town of Lippstadt in 1928. In the 1950s the company started specializing in valves for heating systems. The tandem valve Mikrotherm developed during this phase was the first great classic from HEIMEIER. The final breakthrough came with the thermostatic valve with an incompressible sensor, corrosion-resistant gunmetal body and the HEIMEIER adaptor M 30 x 1.5 presented in 1969. These three typical features have been retained till this day a decisive reason for the triumphal march of the HEIMEIER thermostatic valve, which has also always been ranked first in product tests for the past 20 years. At the German testing institution, Stiftung Warentest, it was given the mark Very good four times in a row. Apart from the thermostatic valves for almost all conceivable requirements the current range includes more than 120 different thermostatic valve bodies on which the over 40 different thermostatic heads can be mounted HEIMEIER offers an extensive assortment of actuators, room thermostats, special valves, manual valves and shut-off valves. HEIMEIER has belonged to the British group IMI plc since the middle of the 1990s. In this constellation HEIMEIER has become a major global player on international markets as well. Today, more than 30 per cent of the product range for heating and airconditioning systems for our export business are manufactured at the production site in the Westphalian town of Erwitte. To be precise. Valve range Printed on paper bleached without the use of chlorine. 9000-18.483 / 02.07 Subject to technical alterations. Theodor Heimeier Metallwerk GmbH Postfach 1124, 59592 Erwitte, Germany Telephone + 49 2943 891-0 Fax + 49 2943 891-100 www.heimeier.com