User Manual Revision 2.001 English



Similar documents
User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

User Manual Revision English

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Application/Connection Examples

TX2123 RS485 TO ETHERNET ADAPTOR

PCS0100en Persy Control Services B.V. Netherlands

TX OPEN RS232/485 module

OPTICAL FIBER repeaters/ isolators

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Xbox LIVE Vision. english

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

INTMOD485-LH Protocol Converter

NC-12 Modbus Application

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

WEB log. Device connection plans

Universal Serial Bus (USB) to DH-485 Interface Converter

Product EASY-USB. Description. USB - UART TTL converter. Seneca s.r.l. support@seneca.it sales@seneca.it. Series of product. Pag.

Infrarot-Bewegungsmelder IP44

=============================== WARNING

Xbox HDMI AV Cable. english ! WARNING. english

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

R60 USB to CAN interface Manual (1.5 EN)

MIC-WKT and MIC-WKT-IR

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Accessories SUNNY REMOTE CONTROL

Installation guide H A. HSI hardwired system interface

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

USB Rover port USB m Cat 5 Extender. User Guide

User Guide. HDMI Active Cable Extender. DVI-7370c

PixelController II Art-Net controller for LED pixels

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

User s Manual Before using the inverter, you need to read and save the safety instructions.

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

M-Bus Network Installation Notes

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Using installed Fieldbus Wiring to carry Ethernet Communications

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

CompactLogix Power Supplies Specifications

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

USB 3.0 PCI Express. 2-Ports Host Controller Card. User Manual. HUSB302PCX

User Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

AXIS T81B22 DC 30W Midspan

Nest Learning Thermostat Installation Guide. Installation step-by-step

User manual Compact Web PLC WP240 series IEC-line

HDCATS-100. Installation Guide

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

PRONET WEB SERVER. INSTRUCTIONS FOR INSTALLATION AND USE English. Version 01/15 Ident no

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Powerware Relay-Serial Card User s Guide

Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions

Digital input modules

Smile 11 AS-i Emergency stop with safe AS-i input node

EZ-View Network Communications Guide

IFS SP-PoE Splitter User Manual

Kvaser Mini PCI Express User s Guide

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

PowerCommand iwatch 100

Modular I/O System Analog and Digital Interface Modules

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

SMART Board 8055i and 8055i-SMP

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

OZS Web server. For LPB/BSB plants

Transcription:

Document code: MN67020_ENG Revision 2.001 Page 1 of 11 User Manual Revision 2.001 English M-Bus Master / RS232 - Converter (Order Codes: HD67020-B2-3, HD67020-B2-10) for Website information: www.adfweb.com?product=hd67020 for Price information: www.adfweb.com?price=hd67020-b2-3 www.adfweb.com?price=hd67020-b2-10 Benefits and Main Features: Low cost No configuration software needed Mountable on 35mm DIN rail Electrical isolation between RS232 and M-Bus Industrial temperature range: -40 C / 70 C (-40 F / 158 F) Other Products HD67020-B2-3 HD67020-B2-10 For other M-Bus products see also the following link: Converter M-Bus / www.adfweb.com?product=hd67021 ( RS232) www.adfweb.com?product=hd67022 ( RS485) www.adfweb.com?product=hd67024 ( USB) www.adfweb.com?product=hd67030 ( Ethernet) Converter M-Bus / Modbus www.adfweb.com?product=hd67029m-232 ( on RS232) www.adfweb.com?product=hd67029m-485 ( on RS485) Analyzer / Scanner / Sniffer M-Bus www.adfweb.com?product=hd67031 M-Bus Repeater - Isolator www.adfweb.com?product=hd67032 Converter M-Bus / www.adfweb.com?product=hd67044m www.adfweb.com?product=hd67053m www.adfweb.com?product=hd67051-b2 www.adfweb.com?product=hd67058-b2 ( Modbus TCP) ( PROFIBUS) ( CANopen) ( DeviceNet) M-Bus Concentrator - Datalogger www.adfweb.com?product=hd67054m (Serial/Modem) www.adfweb.com?product=hd67057-b2-xxx (Ethernet) M-Bus Slave / Modbus Master - Converter www.adfweb.com?product=hd67059m-232 Do you need to choose a device? do you want help? Ask it to the following link: www.adfweb.com?cmd=helpme

INDEX: Page INDEX 2 UPDATED DOCUMENTATION 2 REVISION LIST 2 WARNING 2 TRADEMARKS 2 SECURITY ALERT 3 CONNECTION SCHEME 4 EXAMPLE OF CONNECTION 5 CHARACTERISTICS 6 POWER SUPPLY 7 CONFIGURATION 8 CHARACTERISTICS OF THE CABLES 8 MECHANICAL DIMENSIONS 9 ORDER CODE 9 ACCESSORIES 9 DISCLAIMER 10 OTHER REGULATIONS AND STANDARDS 10 WARRANTIES AND TECHNICAL SUPPORT 11 RETURN POLICY 11 PRODUCTS AND RELATED DOCUMENTS 11 Document code: MN67020_ENG Revision 2.001 Page 2 of 11 UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: Updated Related to the product you own To obtain the most recently updated document, note the document code that appears at the top right-hand corner of each page of this document. With this Document Code go to web page www.adfweb.com/download/ and search for the corresponding code on the page. Click on the proper Document Code and download the updates. To obtain the updated documentation for the product that you own, note the Document Code (Abbreviated written "Doc. Code" on the label on the product) and download the updated from our web site www.adfweb.com/download/ REVISION LIST: Revision Date Author Chapter Description 1.000 30/09/2011 Fl All First release version 2.000 28/08/2012 Fl All Revision 2.001 04/04/2013 Nt All Added new chapters WARNING: ADFweb.com reserves the right to change information in this manual about our product without warning. ADFweb.com is not responsible for any error this manual may contain. TRADEMARKS: All trademarks mentioned in this document belong to their respective owners.

Document code: MN67020_ENG Revision 2.001 Page 3 of 11 SECURITY ALERT: GENERAL INFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation. The same applies also when using accessories. INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e. independent limit switches, mechanical interlocks, etc.). QUALIFIED PERSONNEL The device can be used only by qualified personnel, strictly in accordance with the specifications. Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and who have appropriate qualifications for their job. RESIDUAL RISKS The device is state of the art and is safe. The instrument can represent a potential hazard if they are inappropriately installed and operated by personnel untrained. These instructions refer to residual risks with the following symbol: This symbol indicates that non-observance of the safety instructions is danger for people to serious injury or death and / or the possibility of damage. CE CONFORMITY The declaration is made by us. You can send an email to support@adfweb.com or give us a call if you need it.

Document code: MN67020_ENG Revision 2.001 Page 4 of 11 CONNECTION SCHEME: Figure 1: Connection scheme for HD67020-B2-3, HD67020-B2-10

Document code: MN67020_ENG Revision 2.001 Page 5 of 11 EXAMPLE OF CONNECTION:

Document code: MN67020_ENG Revision 2.001 Page 6 of 11 CHARACTERISTICS: The HD67020-B2-xx is an M-Bus Master / RS232 Converter. The M-Bus / RS232 Converter allows the following characteristics: Electrical isolation between RS232 and M-Bus; No configuration software needed; Mountable on 35mm Rail DIN; Power Supply 15 21V AC or 18 35V DC; Overcurrent and short-circuit protection on the M-Bus; Baudrate: from 300 to 38400, Parity: None, Odd, Even; Temperature range -40 C to 70 C. At the Converter can be connected up to 10 standard M-Bus devices (1,5mA). This number depends of the code expressed by the xx number: HD67020-B2-3 support up to 3 M-Bus devices; HD67020-B2-10 support up to 10 M-Bus devices. The product allows to use an existent M-Bus program or allows to create an own program. It is necessary only to write the M-Bus frames on Serial RS232 and then receive the reply. For information about M-Bus see the link: www.m-bus.com. Note: The device gives back an echo of the data send on RS232 before sending the reply of the slave.

Document code: MN67020_ENG Revision 2.001 Page 7 of 11 POWER SUPPLY: The devices can be powered at 15 21V AC and 18 35V DC. The consumption depends to the code of the device. For more details see the two tables below. VAC VDC Vmin Vmax Vmin Vmax 15V 21V 18V 35V Consumption at 24V DC: Device No Load [W/VA] Full Load [W/VA]* HD67020-B2-3 1.9 1.4 HD67020-B2-10 2.4 * This value is with all the Slave M-Bus devices of the code (3,10) connected to the line Warning: Not reverse the polarity power HD67020-B2-xx

Document code: MN67020_ENG Revision 2.001 Page 8 of 11 CONFIGURATION: The device doesn t need to be configured. The baudrate is automatically detected at RS232 side and used (the same) to the M-Bus side. CHARACTERISTICS OF THE CABLES: RS232: The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a NULL MODEM cable (a serial cable where the pins 2 and 3 are crossed). It is recommended that the RS232C Cable not exceed 15 meters. M-BUS: Figure 3: Null modem cabling A two wire standard telephone cable (JYStY N*2*0.8 mm) is used as the transmission medium for the M-Bus. The maximum distance between a slave and the repeater is 350m; this length corresponds to a cable resistance of up 29Ω. This distance applies for the standard configuration having Baud rates between 300 and 9600 Baud, and a maximum of 250 slaves. The maximum distance can be increased by limiting the Baud rate and using fewer slaves, but the bus voltage in the space state must at no point in a segment fall below 12V, because of the remote powering of the slaves. In the standard configuration the total cable length should not exceed 1000m, in order to meet the requirement of a maximum cable capacitance of 180nF. (Taken from M-Bus specifics)

Document code: MN67020_ENG Revision 2.001 Page 9 of 11 MECHANICAL DIMENSIONS: Figure 4: Mechanical dimensions scheme for HD67020-B2-3, HD67020-B2-10 ORDER CODES: Order Code: HD67020-B2-3 - M-Bus Master / RS232 - Converter (up to 3 slaves connected to M-Bus) Order Code: HD67020-B2-10 - M-Bus Master / RS232 - Converter (up to 10 slaves connected to M-Bus) ACCESSORIES: Order Code: APW020 - Power Supply for M-Bus Master device that supports up to 20 Slaves Order Code: AC34107 - Null Modem Cable Fem/Fem DSub 9 Pin 1,5 m Order Code: AC34114 - Null Modem Cable Fem/Fem DSub 9 Pin 5 m

Document code: MN67020_ENG Revision 2.001 Page 10 of 11 DISCLAIMER All technical content within this document can be modified without notice. The content of the document content is a recurring audit. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use. OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment (as in the European Union and other European countries with separate collection systems). This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it should be taken to an applicable collection point for the recycling of electrical and electronic equipment. If the product is disposed correctly, you will help prevent potential negative environmental factors and human health, which could otherwise be caused by inappropriate disposal. The recycling of materials will help to conserve natural resources. For more information about recycling this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE The device respects the 2002/95/EC Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (commonly referred to as Restriction of Hazardous Substances Directive or RoHS). CE MARKING The product conforms with the essential requirements of the applicable EC directives.

Document code: MN67020_ENG Revision 2.001 Page 11 of 11 WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: 1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the request, you need to provide detailed information about the problem. 2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs billed to us will not be accepted). If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no longer under warranty, you will receive a repair estimate. PRODUCTS AND RELATED DOCUMENTS: Part Description URL HD67120 Converter Ethernet to RS232/RS485 www.adfweb.com?product=hd67120 HD67119 Converter USB 2.0 to RS485 Isolated www.adfweb.com?product=hd67119 HD67507 Gateway Modbus TCP Server to RTU Master www.adfweb.com?product=hd67507 HD67510 Gateway Modbus TCP Client to RTU Slave www.adfweb.com?product=hd67510