Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit



Similar documents
Real-Time PCR Vs. Traditional PCR

Essentials of Real Time PCR. About Sequence Detection Chemistries

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Factors Influencing Multiplex Real-Time PCR

Absolute Quantification Getting Started Guide

SYBR Green Realtime PCR Master Mix -Plus-

TaqMan Fast Advanced Master Mix. Protocol

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Absolute Quantitation Using Standard Curve Getting Started Guide

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Applied Biosystems 7500/7500 Fast Real-Time PCR Systems. SUBJECT: Memory Upgrade Requirements for 7500 Software v2.0

SeqScape Software Version 2.5 Comprehensive Analysis Solution for Resequencing Applications

360 Master Mix. , and a supplementary 360 GC Enhancer.

Introduction To Real Time Quantitative PCR (qpcr)

Mir-X mirna First-Strand Synthesis Kit User Manual

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Quantitative PCR Systems

Quantifiler HP and Trio DNA Quantification Kits User Guide

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Quantification of Mycobacterium Tuberculosis. 150 tests

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

Human Herpes Virus 4 (Epstein Barr)

Quantifiler Kits Quantifiler Human DNA Quantification Kit and Quantifiler Y Human Male DNA Quantification Kit

Path-ID Multiplex One-Step RT-PCR Kit

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

Megaplex Pools For microrna Expression Analysis

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

Co Extra (GM and non GM supply chains: Their CO EXistence and TRAceability) Outcomes of Co Extra

Relative Quantification Applied Biosystems 7300/7500 Real Time PCR System

User Bulletin #2 ABI PRISM 7700 Sequence Detection System

PicoMaxx High Fidelity PCR System

PCR Instruments and Consumables

Reconstituting and Diluting Primers and TaqMan Probes

Gene Expression Assays

RealStar HBV PCR Kit /2012

2.500 Threshold e Threshold. Exponential phase. Cycle Number

Lyme Disease. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... RecA gene. 150 tests. Primerdesign Ltd.

Application Guide... 2

HID Real-Time PCR Analysis Software

Real-Time Quantitative PCR Instruments and Consumables

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

Quantification of Hepatitis B Virus. Core Protein Region. 150 tests

Validation Guide for the DNA IQ Reference Sample Kit for Maxwell 16 Printed in USA. 9/06 Part# GE181

Real-time PCR: Understanding C t

Real-time quantitative RT -PCR (Taqman)

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere tests. Primerdesign Ltd.

StepOne and StepOnePlus Real-Time PCR Systems

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

Quantification of Propionibacterium acnes. Standard kit 150 tests

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

Reagent Guide. Applied Biosystems StepOne and StepOnePlus Real-Time PCR Systems

Fast PCR: General Considerations for Minimizing Run Times and Maximizing Throughput

Validating Microarray Data Using RT 2 Real-Time PCR Products

HBV Quantitative Real Time PCR Kit

Beginner s Guide to Real-Time PCR

Lyme Disease. RecA gene. 150 tests. Quantification of Lyme Disease genomes. Advanced kit handbook HB

SEQUENCING. From Sample to Sequence-Ready

Gene Expression Assay Performance Guaranteed With the TaqMan Assays QPCR Guarantee Program

LightCycler 480 Real-Time PCR System

Aurora Forensic Sample Clean-up Protocol

Getting Started Guide

The AB7900Fast and Principles of Real Time PCR

Stratagene QPCR Mouse Reference Total RNA

DNA Sequence Analysis

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

TaqMan MicroRNA Assays

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

Borrelia burgdorferi

Absolute Quantitation Using Standard Curve Getting Started Guide

Streptococcus pneumoniae

PrimeSTAR HS DNA Polymerase

QPCR Applications using Stratagene s Mx Real-Time PCR Platform

GenScript BloodReady TM Multiplex PCR System

User Bulletin. GeneMapper Software Version 4.0. Installation Options. In This User Bulletin. Overview

TITRATION OF raav (VG) USING QUANTITATIVE REAL TIME PCR

Yfiler Plus PCR Amplification Kit

EZValidation Online Tool. The easy way to apply guidelines. The EZValidation Online Tool. The implementation of new tests

Real Time PCR Kit for Human Herpes Virus Type 6 Cat No. TM-60027: Primer Set

ab Hi-Fi cdna Synthesis Kit

BacReady TM Multiplex PCR System

Real time and Quantitative (RTAQ) PCR. so I have an outlier and I want to see if it really is changed

The Financial Benefits of the MicroSEQ Microbial Identification System

Herpes Simplex Virus 1 and 2

AffinityScript QPCR cdna Synthesis Kit

Highly specific and sensitive quantitation

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

Troubleshooting Sequencing Data

Procedures For DNA Sequencing

qstar mirna qpcr Detection System

Profiling of microrna in Blood Serum/Plasma. Guidelines for the mircury LNA TM Universal RT microrna PCR System

Quantitative Real Time PCR Protocol. Stack Lab

SNPbrowser Software v3.5

Easy Collection and Extraction of BioSamples Ahlstrom GenCollect Ahlstrom GenCollect Color

QuantStudio 12K Flex Real-Time PCR System. The all-in-one qpcr instrument

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR. Results Interpretation Guide

Transcription:

Product Bulletin Human Identification Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit The Quantifiler kits produce reliable and reproducible results, helping to select the appropriate short tandem repeat (STR) analysis method, reducing costs and saving time The Quantifiler Y Human Male DNA Quantification Kit is the first commercially available kit for male DNA quantification, a valuable tool for sexual assault sample analysis Pre-formulated Internal PCR Control (IPC) in each reaction allows quick identification of samples that may be inhibited or that do not contain human DNA Both Quantifiler kits utilize the same, simple protocol that requires fewer steps, minimizing hands-on time, and reducing manual error Both Quantifiler kits deliver specific, robust quantification of samples with DNA concentrations of 0.023µg/L to > 50µg/L Introduction DNA quantification forensic samples ensure optimal STR analysis. Quantifying the amount of amplifiable human DNA and human male DNA prior to subsequent STR analysis is fast, easy, and reliable, thanks to two reagent kits from Applied Biosystems. The Quantifiler Human DNA Quantification Kit and the Quantifiler Y Human Male DNA Quantification Kit provide reliable, reproducible, and highly sensitive real-time PCR quantification results for human identity samples. Optimized and validated for use with the Applied Biosystems 7500 Real-Time PCR System and the ABI PRISM 7000 Sequence Detection System, the Quantifiler kits provide an ideal quantification solution to meet the stringent requirements of the human identification community. The Quantifiler Y Human Male DNA Quantification Kit provides additional value when analyzing samples that may contain mixtures of female and male DNA, by specifically amplifying a target only found on the Y chromosome. Applied Biosystems offer the most complete, integrated system for the quantitation and STR analysis, including validated reagent kits, instruments, analysis software, technical training, and customer support services. Leading the way, the Human Identification group at Applied Biosystems offers the best scientific solutions continuing to enable laboratories to process more samples more efficiently. No other company delivers the depth of products, expertise, and applications support that are available for human identification applications. Reliable. Reproducible. Real-Time. The Quantifiler kits are optimized for use with the same simple protocol, utilizing the 5' nuclease assay (real-time PCR) and TaqMan probe-based technology for maximum reliability and ease of use (see Figure 1). During the real-time PCR assay, the accumulating fluorescent-labeled PCR product is monitored as amplification occurs, allowing the analyst to view the cycle-

to-cycle increase in the fluorescent signal (see Figure 2). Since the Quantifiler kits are based on well characterized PCR technology that determines the amount of DNA present in a sample, the results provide an accurate assessment of how downstream STR analysis will perform. Because Applied Biosystems quantification kits and AmpFlSTR kits utilize the same PCR technology, the Quantifiler kits provide the most accurate indication of subsequent STR analysis available. With one mouse click the real-time PCR amplification results are obtained using the Quantifiler kits, the 7000 and 7500 System Software automatically calculates the amount of total amplifiable DNA present in each sample. The calculation is determined by the cycle number at which the amount of amplified product crosses the noise threshold in each reaction. For each sample, the cycle number is then compared against a standard curve generated from a series of DNA standards, translating the cycle number into a DNA concentration. The Quantifiler Human DNA Standard is included in each kit and is simultaneously amplified with forensic samples on the same reaction plate. The values can then be used to select the appropriate amount of amplifiable DNA that can be added to subsequent STR amplification. The Quantifiler kits enable balanced STR results to be obtained the first time reducing the test cost and time to reportable result. Streamline Workflow. Ensure Superior Results The Quantifiler kits include all reagents necessary for the amplification, detection, and quantification of 400 reactions using the Applied Biosystems 7500 Real-Time PCR System or the ABI PRISM 7000 Sequence Detection System. Each kit contains three reagent components: Quantifiler PCR Mix Quantifiler Human Primer Mix or Quantifiler Y Male Primer Mix Quantifiler Human DNA Standard Both Quantifiler kits utilize the same reagents and allow the user to select the appropriate Quantifiler Primer Mix, which contains a pre-formulated mixture of primers and probes that amplify either the Human Telomerase Reverse Transcriptase gene (Quantifiler Human Kit) or the SRY gene (Quantifiler Y Kit). By amplifying both systems in a single tube, the Quantifiler kits provide an indicator of potential sample inhibition, and allow for quick identification of samples that do not contain human DNA. Each kit includes the Quantifiler Primer Mix specific for either the Quantifiler Human or Quantifiler Y Human Male Assay, 1 bottle of the Quantifiler PCR Reaction Mix, and 1 tube of the Quantifiler Human DNA Standard, sufficient for 400 reactions. The Quantifier Human Primer Mix and Quantifiler Y Male Primer Mix is formulated specifically to amplify the Human Reverse Transcriptase gene or SRY gene and is pre-formulated with the IPC system. Fast and Easy Protocol The Quantifiler kits minimize the labor required by reducing procedural steps and accelerating time-to-results. The simple protocol includes preparation of a DNA standard curve, setting up the PCR reactions, and clicking Start to begin amplification and detection. No additional steps are required. Unlike other quantification methods, the Quantifiler kits protocol does not require lengthy incubation steps, tubes to open and close, sample-transfer steps, or mid-process mixing and washing. The entire quantification procedure can be completed in approximately thirty minutes of hands-on time, providing robust, reproducible results Figure 1. Real-time PCR reaction. FORWARD PRIMER PROBE REVERSE PRIMER 1. Polymerization: A fluorescent reporter (R) dye and a quencher (Q) are attached to the 5' and 3' ends of a TaqMan probe, respectively. 2. Strand displacement: When the probe is intact, the reporter dye emission is quenched.

a b c for up to 80 samples and one set of standard curves (an 8 point standard curve run in duplicate). Because they use the same amplification and detection parameters, both kits can be run on a single plate, yielding results for up to 64 samples and two sets of standard curves (see Figure 3). Minimal hands-on time allows analysts to focus on other aspects of their laboratory work, and reduces the possibility of errors that may occur with multiple handling steps. Users of the Quantifiler kits have greater confidence in the reliability of their DNA quantification results. The easy, three-step protocol for reaction setup together with automated amplification, detection, and analysis procedures makes DNA quantification a simple, streamlined procedure. Validated Protocols for a Variety of Sample Types The Quantifiler kit components and amplification protocols are validated and optimized as a component of Applied Biosystems integrated systems for human identification applications. Stringent validation by the manufacturer ensures specific, robust amplification of human identity samples with DNA concentrations of 0.023µg/L to >50µg/L. Figure 2. Data obtained using Quantifiler Kits. 2a. Example of a positive DNA sample. 2b. Example of a sample with no detectable DNA. 2c. Example of a sample that is inhibited. 3. Cleavage: During each extension cycle, the DNA polymerase cleaves the reporter dye from the probe. 4. Polymerization completed: Once separated from the quencher, the reporter dye emits its characteristic fluorescence.

A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 Rows 1 2: Quantifiler Kit Standards (8-point standard curve run in duplicate) Rows 3 12: Quantifiler Kit Samples 2 Rows 1 2: Quantifiler Human Kit Standards (8-point standard curve run in duplicate) Rows 3 6: Quantifiler Human Kit Samples Rows 7 8: Quantifiler Y Kit Standards (8-point standard curve run in duplicate) Rows 9 12: Quantifiler Y Kit Samples Figure 3. Examples of possible plate setups using the Quantifiler and Quantifiler Y Human DNA Quantification Kits. Experiments to evaluate the Quantifiler kits were performed at Applied Biosystems, according to the DNA Advisory Board (DAB) guidelines, Quality R Assurance Standard for Forensic DNA Testing Laboratories. Complete protocols and a summary of the experiments performed and results obtained for developmental validation are available in the Quantifiler Kits User s Manual. For information on Applied Biosystems developmental validation of the Quantifiler kits please reference the article Developmental Validation of the Quantifiler Real-Time PCR Kits for the Quantification of Human Nuclear DNA Samples, Journal of Forensic Sciences, July 2005. Both Quantifiler kits require minimal sample handling and quantify DNA from a wide variety of human identity sample types, including, but not limited to, buccal swabs, blood, semen, and tissue samples. The quantification protocol is compatible with several commonly used DNA extraction methods including Phenol-Chloroform, Chelex, and silica based chemistries. Once samples are extracted, loaded into the quantification tubes, and sealed, no further sample handling is required. This ensures sample integrity and reduces the risk of contamination. Complete System Approach to Quantification Applied Biosystems offers fully integrated reagents, instruments and analysis software for processing data generated in human identification laboratories. DNA samples quantified with the Quantifiler kits may be amplified and analyzed with the ABI PRISM Sequence Detection System that accommodates an individual laboratory s throughput needs. Each Sequence Detection System includes all of the software necessary to amplify, detect, and analyze samples processed using both Quantifiler kits. Stringent Quality Control Each Quantifiler kit lot is subjected to stringent quality control testing to help ensure reliability and reproducibility from lot to lot. Applied Biosystems develops and manufactures its products in accordance with ISO 9001 quality system requirements. Additionally, a Certificate of Analysis is available upon request, which confirms that the specific components of the kits meet quality-assurance testing specifications. The Quantifiler and Quantifiler Y Human Quantification Kits convey certain specific rights to perform paternity and forensics testing services in conjunction with an Authorized Thermal Cycler such as the Applied Biosystems 7500 Real-Time PCR System or the ABI PRISM 7000 Sequence Detection System.

Highly Trained Forensic Application Specialists Applied Biosystems highly trained and experienced Forensic Application Specialists are available either by telephone or online to assist your laboratory with the implementation and use of the Quantifiler kits. Additional training on the use of the Quantifiler kits and Sequence. Detection Systems can be provided on site by a Forensic Application Specialist with the purchase of a new Applied Biosystems 7500 Real-Time PCR System or ABI PRISM 7000 Sequence Detection System and a Quantifiler kit. Applied Biosystems 7500 Real-Time PCR System and Quantifiler Kits. Features and Benefits at a Glance Both Quantifiler kits meet the Human Identification community s requirements for highly sensitive quantification results Quantification results more accurately reflect the performance of DNA amplification that will be observed in downstream PCR-based applications An IPC is pre-formulated in each reaction, allowing you to quickly identify samples that may be inhibited or that do not contain human DNA Easy-to-follow protocol minimizes hands-on time and reduces the possibility of contamination Reliable and reproducible results, produced with a single mouse click Both Quantifiler kits have a greater than 2,000-fold dynamic range of detection delivering quantification of samples with DNA concentrations of 0.023ng/µL to > 50ng/µL. Quantifiler Y and Yfiler kits can be used together to obtain the most comprehensive information present in sexual assault samples

Ordering Information Description Rxns x Total Rxn Volume P/N Quantifiler Human DNA Quantification Kit 400 x 25 µl 4343895 Quantifiler Y Human Male DNA 400 x 25 µl 4343906 Quantification Kit Quantifiler Human DNA Kit User s Manual 4344790 ABI PRISM 7000 Sequence Detection System (Laptop) 4349132 ABI PRISM 7000 Sequence Detection System (Tower) 4349117 Applied Biosystems 7500 Real-Time PCR System (Laptop) 4366604 Applied Biosystems 7500 Real-Time PCR System (Tower) 4366605 For Research, Forensic or Paternity Use Only. Not for use in diagnostic procedures. Notice to Purchaser: Limited License A license under the non-u.s. counterparts of U.S. Patents Nos. 4,683,202, 4,683,195 and 4,965,188 owned by F. Hoffmann-La Roche Ltd, for use in research and forensic and paternity testing, has an up-front fee component and a running-royalty component. The purchase price of the Quantifiler Human DNA Quantification Kit and Quantifiler Y Human Male DNA Quantification Kit includes a limited, non-transferable license under the running-royalty component to use only this amount of product to practice the Polymerase Chain Reaction (PCR) and related processes described in said patents solely in forensic and paternity testing applications, including reporting results of purchaser s activities for a fee or other commercial consideration and also for the purchaser s own internal research, when this product is used in conjunction with a thermal cycler whose use is covered by the up-front fee component. Rights to the up-front fee component must be obtained by the end user in order to have a complete license to use this product in the PCR process. Rights under the up-front fee component may be purchased from Applied Biosystems or obtained by purchasing an Authorized Thermal Cycler. The purchase price of this product includes a limited, non-transferable license under some or all of U.S. Patents Nos. 5,210,015, 5,487,972, 5,804,375, 5,476,774, and 5,219,727, and corresponding patent claims outside the United States, owned by Roche Molecular Systems, Inc. or F. Hoffmann-La Roche Ltd ( Roche ), and under U.S. Patents Nos. 5,538,848, 5,723,591, 5,876,930, 6,030,787, and 6,258,569, and corresponding patent claims outside the United States, owned by the Applera Corporation, for using only this amount of product in the practice of the 5 nuclease process solely in forensic and paternity testing, including reporting results of purchaser s activities for a fee or other commercial consideration and also for the purchaser s own internal research. No right under any other patent claims (such as apparatus or system claims in U.S. Patent No. 6,814,934) and no right to use this product for any other purpose, is hereby granted expressly, by implication, or by estoppel. Further information on purchasing licenses may be obtained from the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA. AB (Design), Applera, Quantifiler, and Yfiler are trademarks, and ABI PRISM and Applied Biosystems are registered trademarks of Applera Corporation or its subsidiaries in the US and/or certain other countries. TaqMan is a registered trademark of Roche Molecular Systems, Inc. 2005 Applied Biosystems. All rights reserved. Printed in the USA, 06/04. P+s Publication 112PB12-04. Headquarters 850 Lincoln Centre Drive Foster City, CA 94404 USA Phone 650.638.5800 Toll Free 800.345.5224 International Sales For our office locations please call the division headquarters or refer to our Web site at /about/offices.cfm