www.klmtechgroup.com TABLE OF CONTENT



Similar documents
TABLE OF CONTENT

TABLE OF CONTENT

TABLE OF CONTENT

TABLE OF CONTENT

Mechanical Installation

TABLE OF CONTENT

TABLE OF CONTENT

TABLE OF CONTENT

TABLE OF CONTENT

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

James M. Pleasants Company

TABLE OF CONTENT

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

NORSOK STANDARD COMMON REQUIREMENTS PIPING FABRICATION, INSTALLATION, FLUSHING AND TESTING

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

TABLE OF CONTENT

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Drive shaft, servicing

PIPING DRAWINGS BASICS N.P.TODKAR

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

TABLE OF CONTENT

TABLE OF CONTENT

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

API Flanged Safety Relief Valves Series 526 CATALOG

TABLE OF CONTENT

Engineered Solutions

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

WATER SERVICE 2

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells Last update: August 12, 2015

I BEAM TRACK INSTALLATION

BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013)

GMC 2013: Piping Misalignment and Vibration Related Fatigue Failures

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

NORSOK Compact Flange Installation and Assembly Procedure

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

TABLE OF CONTENT

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items

TYPE E Main Valve Sizes 3 /8 through 12

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Pressure Vessel Assessment Report

Oil and Gas Pipeline Design, Maintenance and Repair

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Select Radiators Installation Guide

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Copper and Copper Alloy Tube, Pipe and Fittings

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

Essentials Welding QA/QC Plan Sample

Trouble shooting guide

Hydraulic control unit series

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

HYDRAULIC PIPING STANDARD HANDBOOK. Revision 1

VAD Variable Area Desuperheaters

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

VAD. Variable Area Desuperheaters

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

TECHNICAL SPECIFICATION

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

SPECIFICATION FOR PIPEWORK WELDING, INSPECTION, SUPPORTING AND TESTING

Pipe Flange Bolting Guide Aztec Bolting Services, Inc.

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Specification for Rotary Drill Stem Elements

V47 Series Temperature Actuated Modulating Water Valves

Customer environment. Customers

STORAGE TANK SELECTION AND SIZING (ENGINEERING DESIGN GUIDELINE)

INSTALLATION & OPERATING INSTRUCTIONS

SureSite Magnetic Liquid Level Indicator

BODY OF KNOWLEDGE API-570 AUTHORIZED PIPING INSPECTOR CERTIFICATION EXAMINATION

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Hose Clamps & Fittings

Installation Instructions

EUROPEAN OEM SERVICE STAUFF. STAUFF - Line - Local solutions for individual customers worldwide

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

Engineering Specifications

LS 2540 SEWER LATERALS AND INSPECTION TEES

SECTION PIPE HANGERS AND SUPPORTS

PTFE Slide Bearings 04/10 149

SECTION FACILITY STORM DRAINAGE PIPING

Green Thread Product Data

TABLE OF CONTENT

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Wastewater Capital Projects Management Standard Construction Specification

NORSOK STANDARD COMMON REQUIREMENTS PIPING DETAILS

PBX Series Quick Fit Connector Bimetallic Steam Traps

SECTION 15 AIR RELEASE VALVE ASSEMBLIES General

Screw Plug Immersion Heaters

TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion

Transcription:

Page : 1 of 32 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia INSTALLATION, FLUSHING AND TABLE OF CONTENT SCOPE 3 REFERENCES 3 SYMBOLS AND ABBREVIATIONS 4 MATERIALS 4 Color Marking of Materials 4 Material Storage, Handling, Receiving and Identification Control 4 FABRICATION OF PIPEWORK 5 General Requirements 5 Welding and NDE 5 Butt Welds for Orifice Runs 6 Screwed Pipe work 6 Dimensional Tolerances for Pre-Fabricated Piping Assemblies 6 Branch Connections and Outlets 9 Pipe Flanges, Mechanical Hub and Clamp Coupling 9 INSTALLATION OF PIPING 8 Pipe work Erection 8 Flanged Joints 10 Strain sensitive equipment with flange connections 10 Gaskets 11 Bolting 11 Pipe Support 12 Global Tolerances, Installation 12 CLEANING OF PIPEWORK 13 General 13 Hydro Flushing 13 Pressurised Air Shock blowing 14 Pneumatic Flushing 14 Soft Pigging 14 Verification of Cleanness 15

Page 2 of 32 PRESSURE TESTS 15 General 15 Test Preparation 15 Test Media 16 Hydrostatic Testing 17 Pneumatic Testing 17 After Completion of Test 17 Test Acceptance Criteria 18 Test Documentation 18 CHEMICAL CLEANING 19 General 19 Documentation 20 HOT OIL FLUSHING 20 General 20 Marking 21 Documentation 21 TIGHTNESS 21 SYSTEM COLOUR CODING OF PIPING 23 Purpose 23 Types of Markers 23 Insulated Lines 24 Plastic/Rubber Lined Piping 24 Obstruction 24 Materials of Markers 24 Fastening Materials 25 Marker Text 25 Size and Use of Markers 25 Positioning of Markers 26 Valve Marking 26 Colour Coding Information 27 APPENDIX A 28 APPENDIX B 30

Page 3 of 32 SCOPE This Project Standard and Specification covers the basis for fabrication, installation, flushing, pressure testing, chemical cleaning, hot oil flushing and system color coding of process, drilling and utility piping for offshore oil and/or gas production facilities. This Project Standard and Specification does not cover the following: - all instrument control piping downstream of first piping block valve; - subsea pipe work and risers; - flexible hoses; - GRP piping; - marine systems in hulls of vessels and floating platforms and land based plants. REFERENCES Throughout this Standard the following dated and undated standards/codes are referred to. These referenced documents shall, to the extent specified herein, form a part of this standard. For dated references, the edition cited applies. The applicability of changes in dated references that occur after the cited date shall be mutually agreed upon by the Company and the Vendor. For undated references, the latest edition of the referenced documents (including any supplements and amendments) applies. 1. ASME B31.3 Process Piping 2. ASME B1.20.1 Pipe Threads, General purpose, Inch 3. ASME PCC2 Repair of Pressure Equipment and Piping 4. ASME VIII Boiler and Pressure Vessel Code, Section VIII Rules for construction of Pressure Vessels, Division 1 5. API 6A API standard 6A 6. NS 813 Piping systems Identification colours for the content 7. NS 4054 Colours for identification 8. ISO 4406 Hydraulic fluid power Fluids Method for coding the level of contamination by solid particles 9. ISO 9095 Steel tubes Continuous character marking and colour coding for material identification 10. ASME PCC-1 Guidelines for Pressure Boundary Bolted Flange Joint Assembly 11.EN 1591 Flanges and their joints

Page 4 of 32 12.ISO 19900 Petroleum and natural gas industries General requirements for offshore structures SYMBOLS AND ABBREVIATIONS SYMBOL/ABBREVIATION ABS API ASME EN GRP He HVAC ISO IX N 2 N 2 He NCR NDE NPT O 2 OD P&ID PAS PVC UV DESCRIPTION absolute American Petroleum Institute American Society of Mechanical Engineers European Standard glass fiber reinforced plastic helium heating, ventilation and air conditioning International Organisation for Standardisation special metallic seal ring nitrogen nitrogen helium non conformance request non destructive examination National Pipe Thread Taper oxygen outside diameter piping and instrument diagram pressurised air shock blowing polyester vinyl chloride ultra violet MATERIALS Color Marking of Materials Color marking shall be according to ISO 9095. If possible, gaskets shall be marked to be visible after installation. Material Storage, Handling, Receiving and Identification Control Procedures for off-loading, storage, recieving, control, traceability and inspection of piping material supplied for fabrication and installation shall be worked out. In general, the following applies: - storage of piping and piping equipment shall be under cover and protected against contact with the ground;

Page 5 of 32 - carbon steel and stainless steel components shall be segregated to avoid any cross contamination. - all fittings and equipment shall be protected against damage during handling from supplier to fabrication yard and further to final installation plant. Especially focus shall be made to sealing surfaces, beveled areas, and contact between different material qualities to avoid surface contamination. This also includes protection during erection phase in order to protect against contamination from other activities on site. FABRICATION OF PIPEWORK General Requirements Prefabricated pipe spools shall be cleaned, painted (if required) and preserved prior to installation. Internal cleaning of pipe spools shall be done by hydro flushing or hydro jetting. The fabrication yard shall be outfitted for work with relevant materials. Intermediate storing, lifting devices and handling equipment shall have a surface not causing contamination of the materials they are used for. All tools shall be restricted to the relevant material group to avoid rust contamination and shall be marked to avoid mixing of tools for different materials. Different grades of stainless steel materials can be handled with the same tools. Separate tools shall be used for titanium materials. All welded attachments to piping, including pads and doubler plates, shall be of a material 100 % compatible with the piping material. Fabrication of high alloy piping shall take place in areas separated from areas where carbon steel piping is fabricated. Titanium fabrication shall also be separated from stainless steel and carbon steel fabrication areas. Bending and forming of pipe shall be carried out in accordance with ASME B31.3 and shall be carried out according to documented procedures. Welding and NDE Internals of in-line valves and equipment that could be damaged due to heat transfer shall be removed prior to welding and/or heat treatment.

Page 6 of 32 Butt Welds for Orifice Runs When the design of an orifice run necessitates welds, these shall be ground smooth and flush with the inside of the pipe. Pipe-tap connections, where required, shall be drilled through the pipe wall and be smooth inside. Screwed Pipework Unless otherwise stated on approved drawing or specifications, pipe threads shall conform to ASME B1.20.1. All threading shall be carried-out after bending, forging or heat treatment, but where this is not possible, suitable thread protection shall be provided. NPT threads need special attention to dimensional tolerances due to the conic configuration. Minimum engagement shall be 4.5 for NPT threads. Tape shall not be used on threads for screwed piping connections. Dimensional Tolerances for Pre-Fabricated Piping Assemblies Dimensional control of prefabricated piping spools shall be performed in a systematic manner, assuring that the final installation will be correct. Prefabricated spools for offshore installation shall be 100 % dimensionally controlled. The tolerances on linear dimensions (intermediate or overall) are illustrated in Figure 1 and Figure 2. These tolerances are not accumulative. Angularity tolerances across the face of flanges, weld end preparation and rotation of flanges shall be as stated in Figure 1 and Figure 2. Closer tolerances on weld end preparations than stated in Figure 1 and Figure 2, may be specified in the relevant welding specification for the material in question, and shown on the fabrication isometric(s). When closer tolerances other than those given above are required, these shall be as specified on the isometric drawing in question.

Page 7 of 32 Figure 1 - Tolerances for prefabricated piping assemblies

Page 8 of 32 Figure 2 - Tolerances for prefabricated piping assemblies Note: 1) Before reworking any spools contact engineering department in order to check complete isometric. 2) Cut to fit requirement to be stated on fabrication isometrics (typically 100 mm). 3) Bolt holes on flanges shall straddle the horizontal or vertical lines or plant north/south centre lines when orientation is not given on drawings.

Page 9 of 32 Branch Connections and Outlets All welded branch connections shall be jointed to the header with full penetration welds. Stub-in connections shall be set-on type. Set-in type is not acceptable. Reinforcement pads or saddles required by specifications and drawings shall be of the same material as the main pipe (unless specified otherwise) and shall be formed and countered to provide a good fit to both main and branch pipe. Branch reinforcement pads shall be according to ASME B31.3. Branch reinforcement pads or each segment thereof shall be provided with a minimum 3,0 mm drilled and tapped hole prior to fitting to the pipe, to ensure leak detection, venting and testing facilities. Whenever possible, pad should be made in one piece before fitting onto pipe. After welding and testing the hole shall be permanently plugged, e.g. welded or metal plug in piping material. Pipe Flanges, Mechanical Hub and Clamp Coupling Seal faces of mechanical hub and clamp couplings and flanges shall be protected during fabrication and storage. Where possible, hub and clamp couplings shall be protected by fitting and hand tightening the complete coupling assembly. INSTALLATION OF PIPING Pipe work Erection All pipes shall be inspected before erection to ensure that they are free from loose contamination. Pipe work shall be erected on permanent supports designated for the line. Temporary supports shall be kept to an absolute minimum, but to an extent sufficient to protect nozzles and adjacent piping from excessive loads during the erection. Tubing shall not be used inside walls or other enclosed compartments without access. The weldolets shall be fully welded to the extent needed to confirm with the design requirements in ASME B31.3. Pipework shall be fitted in place without springing or forcing to avoid undue stressing of the line or strain being placed on a vessel or item of equipment, etc. All temporary pipe spools and supports that are an aid to erection, testing/flushing, sea fastening, etc. are to be specially marked for removal identification. All valves shall be protected against ingress of dirt during any temporary storage.

Page 10 of 32 Flanged Joints Before assembly, flanges shall not have any damage that will interfere with the integrity of the joint. The flanges shall be clean and free from any rust, dirt or other contamination. The joints shall be brought up flush and square without forcing so that the entire mating surfaces bear uniformly on the gasket and then mated-up with uniform bolt tension. With the piping flange fitted and prior to bolting-up the joint, the following shall be maintained: - bolting shall move freely through accompanying bolt-holes at right angle to the flange faces; - there shall be a clear gap between two flange faces before gasket installation. There shall be sufficient flexibility to install and replace gaskets. Compact flange heel are one of two sealing surfaces and are vulnerable to damage from corrosion and rough handling and need special attention. For work on flanges, OLF guideline 118 gives a practical view on flange work. Strain sensitive equipment with flange connections Flange covers shall be retained on all flange connections to valve or equipment, until ready to connect the mating piping. All equipment shall be blanked, either by pressure test blanks, spades or blinds, to stop the ingress of internal pipe debris. Flanges connecting to strain sensitive mechanical equipment (e.g. pumps, compressors, turbines, etc.) shall be fitted-up in close parallel and lateral alignment prior to tightening the bolting. Unacceptable forces transferred on to the nozzles shall be prevented. To achieve this true alignment, full advantage shall be taken of the 'cut to fit' allowances and loose flanges provided. In general, flange connections to strain sensitive equipment shall be the last connection made on completion of a line or interconnecting system of lines. Connections to strain sensitive equipment shall always be subject to stress analysis with true misalignment. As a minimum the following shall be evaluated: - the stiffness of the system; - sufficient tightening force for flange connections; - allowable nozzle loads for the equipment. With the piping flange fitted and prior to bolting-up the joint, the tolerances shown in Figure 3 shall be maintained. Maximum angular misalignment: