20 kw. 20 kw ISO. Synergy Variable Speed Residential Standby Generator Air-Cooled Gas Engine FEATURES



Similar documents
16/20/22 kw CENTURION SERIES

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

16/20/22 kw. 16/20/22 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine

8/11 kw. 8/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Diesel Engine Driven Generators Page 1 of 6

Spark-ignited generator set

Magnum Mobile Generator MMG55 Specifications

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Frequently Asked Questions Generators

C18 ACERT Fire Pump Tier bkw/ rpm

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

residential & commercial Generators

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

ASCO SERIES 185 Power Transfer Switches

Technical Specification. Generating Set with Waukesha engine burning natural gas

Centro-Matic Automatic Lubrication Systems System Controls

DIESEL GENERATOR SETS

WHOLESALE DIRECT INC WEST 65TH STREET

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

GTEC transfer switch open transition

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Giving You the Power to Stand Alone

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

FTQ. Daikin Inverter Ducted Heat Pump

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

MAC-120HE-01 Air-Cooled Chiller

Uninterruptible Power Supply

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

CorePower Home Standby Generator

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

APS100 Rental Generator Set Specification

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Diesel Generator Set Model DFHC 60 Hz

Diesel Generating Set

How To Control A Power Command Powerplant

Diesel Generator Set Model DGDK 60 Hz

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

VLT Series 300 Watt True Sine Wave Inverter

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Continuous Power... Continuous Protection

Thyristor-controlled power supplies and battery chargers

Generator DoCKInG StatIonS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

New 27 hp 2 Cylinder Liquid-Cooled Engine

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

32VFD Variable Frequency Drives for Centrifugal Chillers

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

It s storming outside. Neighbors have no power. For you, dinner s on in 15.

Power Generation. Power Control PCL System Generator Set Control

D RDC2 Controller d One digital controller manages both the generator set and

Diesel Generator Set Model DFMB 60 Hz

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

PM734F - Technical Data Sheet Winding 28

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Mobile Data Power Model: MDP-25

Specifying a Variable Frequency Drive s

Oil and Coolant Circulating Heating System. Model - OCSM

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Low Profile Unit Cooler

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Rotary screw compressors kw 5,5 7, , bar MODULO

Annex-A TECHNICAL SPECIFICATION

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

POWER GENERATION.

The kva RAnge

Marine Generating Sets 3.7 to 50 kva

FTXS. Wall Mount Heat Pump or Cooling Only

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Transcription:

Synergy Variable Speed Residential Standby Generator Air-Cooled Gas Engine 1 of 5 INCLUDES: G-Flex Variable Speed Technology Two Line LCD Multilingual Digital Evolution Controller (English/Spanish/ French/Portuguese) 200 Amp Smart Switch with onboard load management Electronic Governor External Main Circuit Breaker, System Status & Maintenance Interval LED Indicators Mobile Link Cellular Monitoring System* GFCI Duplex Outlet Sound Attenuated Enclosure Flexible Fuel Line Connector Composite Mounting Pad Protective Base Fascia Natural Gas or LP Gas Operation 5 Year Limited Warranty Capability to be installed within 18" (457 mm) of a building** Standby Power Rating 006055-1 (Aluminum - Gray) - 60 Hz - USA 006098-1 (Aluminum - Gray) - 60 Hz - Canada *Built in the USA using domestic and foreign parts * Download the free App at ** Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN. But it doesn t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. G-Flex Variable Speed Technology: By utilizing patented variable speed technology, the generator is capable of running at various RPMs depending on the electrical demand, resulting in quieter operation, better fuel economy and produce power at <1.5% total harmonic distortion for quality power. TEST CRITERIA: PROTOTYPE TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITY SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ISO 9001: 2008

2 of 5 features and benefits Engine Generac (OHVI) design Spiny-lok cast iron cylinder walls Electronic ignition/spark advance Full pressure lubrication system Low oil pressure shutdown system High temperature shutdown Optimized muffler and resonator Generator Cylindrically wound rotor Skewed stator Variable speed, constant frequency AVR Automatic voltage regulation UL 2200 listed Transfer Switch Fully automatic Maximizes engine breathing for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. Rigid construction and added durability provide long engine life. These features combine to assure smooth, quick starting every time. Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating. Results in dramatically quieter operation during exercise and normal loads than constant speed systems. Allows for multi-phase excitation, enabling variable engine RPM resulting in fuel savings and sound reduction. Produces a smooth output waveform for compatibility with electronic equipment. Provides uncommonly clean power with less than 1.5% THD (Total Harmonic Distortion) Regulates the output voltage to ±1% prevents damaging voltage spikes. For your safety. Transfers your vital electrical loads to the energized source of power. DPM Technology NEMA 3R Rated Evolution Controls Auto/Manual/Off illuminated buttons Sealed, raised buttons Utility voltage sensing Generator voltage sensing Digital Power Management Technology allows for the smart control of two air conditioners without any additional items. Can be mounted indoors or outdoors for simple, low cost installation Selects the operating mode and provides easy, at-a-glance status indication in any condition. Smooth, weather-resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to ensure the cleanest power delivered to the home. Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Engine warm-up Engine cool-down Ensures engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week as default with the option of setting weekly or monthly to allow for flexibility and potential fuel savings. Smart battery charger Main line circuit breaker Electronic governor Unit Weather protective enclosure Enclosed critical grade muffler Small, compact, attractive SAE Installation System 1 ft (305 mm) flexible fuel line connector Composite mounting pad Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Protects generator from overload. Maintains constant 60 Hz frequency. Ensures protection against mother nature and can withstand winds up to 150mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation. Sound attenuated enclosure ensures quiet operation. Easy installation.

specifications Generator 006055-1/006098-1 Rated Maximum Continuous Power Capacity (LP) 20,000 Watts* Rated Maximum Continuous Power Capacity (NG) 18,000 Watts* Rated Voltage 240 Rated Maximum Continuous Load Current 240 Volts (LP/NG) 83.3/75 Total Harmonic Distortion Less than 1.5% Main Line Circuit Breaker 90 Amp Phase 1 Number of Rotor Poles 2 Rated AC Frequency 60 Hz Power Factor 1.0 Battery Requirement (not included) Group 26R, 12 Volts and 525 CCA Minimum Unit Weight (lb/kg) 471/213.6 Dimensions (L x W x H) in/mm 48 x 25 x 29/1218 x 638 x 732 Sound output in db(a) at 23 ft (7 m) with generator operating at normal load** 63 Sound output in db(a) at 23 ft (7 m) with generator in Quiet-Test low-speed exercise mode** 57 3 of 5 Engine Type of Engine GENERAC OHVI V-TWIN Number of Cylinders 2 Displacement 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Ignition System Solid-state w/ Magneto Governor System Electronic Compression Ratio 9.5:1 Starter 12 Vdc Oil Capacity Including Filter Approx. 1.9 qt/1.8 L Operating rpm 2,700-3,600 Fuel Consumption Natural Gas Liquid Propane ft³/hr (m³/hr) Exercise 1/2 Load Full Load ft 3 /hr (gal/hr) [l/hr] Exercise 1/2 Load Full Load 43 (1.22) 174 (4.93) 285 (8.07) 5.55 (.15) [.58] 59.7 (1.64) [6.20] 123.7 (3.4) [12.94] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercury) for natural gas, 10-12" water column (19-22 mm mercury) for LP gas. For Btu content, multiply ft 3 /hr x 2500 (LP) or ft 3 /hr x 1000 (NG). For Megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG). Controls 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons: Auto Automatic Start on Utility failure. Programmable exercise. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. Off Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance Messages Engine Run Hours Indication Programmable start delay between 2-1500 seconds (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning Run/Alarm/Maintenance Logs 50 Events Each Engine Start Sequence Cyclic cranking: Engine cranks a maximum of five times at factory set intervals and durations. Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Charger Fault/Missing AC Warning Low Battery/Battery Problem Protection and Battery Condition Indication Automatic Voltage Regulation with Over and Under Voltage Protection Under-Frequency/Overload/Stepper Overcurrent Protection Safety Fused/Fuse Problem Protection Automatic Low Oil Pressure/High Oil Temperature Shutdown Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown High Engine Temperature Shutdown Internal Fault/Incorrect Wiring Protection Common External Fault Capability Field Upgradable Firmware **Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 C (10 F) above 16 C (60 F).

4 of 5 switch options Service Rated Smart Switch Features (USA) Includes Digital Power Management Technology specifically designed for variable speed operation standard (DPM). Intelligently manages two air conditioner loads with no additional hardware. Up to four more large (120/240 VAC) loads can be managed when used in conjunction with 50 amp Power Management Modules (PMM**). Electrically operated, mechanically-held contacts for fast, clean connections. Rated for all classes of load, 100% equipment rated, both inductive and resistive. 2 pole, 250 VAC contactors. Service rated, dual coil design. Rated for both aluminum and copper conductors. NEMA/UL 3R aluminum outdoor enclosure. Main contacts are silver plated or silver alloy to resist welding and sticking. 006055-1 (USA) No. of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240, 1Ø Utility Voltage Monitor (Fixed)* -Pick-up -Dropout 80% 60% Return to Utility* approx. 13 sec. Bi-weekly exercise for 5 minutes* UL Listed Enclosure Type NEMA 3R Withstand Rating (Amps) 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller W1 **Note: PMM starter kit is required prior to using the modules. *** Note: Any single load larger than 10 kw or 2.4 kvar must be connected to the load management control Dimensions 200 Amps 120/240, 1ø Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 27.24 30.0 11.4 13.5 7.09 mm 692.0 762.4 289.0 343.0 180.0 DEPTH H2 W2 H1 Non-service Rated Smart Switch Features (Canada) Includes Digital Power Management Technology specifically designed for variable speed operation standard (DPM). Intelligently manages two air conditioner loads with no additional hardware. Up to four more large (120/240 VAC) loads can be managed when used in conjunction with 50 amp Power Management Modules (PMM**). Electrically operated, mechanically-held contacts for fast, clean connections. Rated for all classes of load, 100% equipment rated, both inductive and resistive. 2 pole, 250 VAC contactors. Dual coil design. Rated for both aluminum and copper conductors. NEMA/UL 3R aluminum outdoor enclosure. Main contacts are silver plated or silver alloy to resist welding and sticking. 006098-1 (Canada) No. of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240, 1Ø Utility Voltage Monitor (Fixed)* -Pick-up -Dropout 80% 60% Return to Utility* approx. 13 sec. Bi-weekly exercise for 5 minutes* CSA Listed Enclosure Type NEMA 3R Withstand Rating (Amps) 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller **Note: PMM starter kit is required prior to using the modules. W1 *** Note: Any single load larger than 10 kw or 2.4 kvar must be connected to the load management control Dimensions 200 Amps 120/240, 1ø Open Transition Non-Service Rated Height Width H1 H2 W1 W2 Depth in 17.24 20.0 12.5 14.6 7.09 mm 437.9 508 317.5 370.8 180.1 DEPTH H2 W2 H1

available accessories # Product Description 005819-0 26R Wet Cell Battery 006212-0 Cold Weather Kit Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product. If the temperature regularly falls below 32 F (0 C), a cold weather kit is required to maintain optimal battery and oil temperatures. Kit consists of battery warmer and oil filter heater with built-in thermostats. 5 of 5 005621-0 Auxiliary Transfer Switch Contact Kit The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may not need. 005704-0 Paint Kit 006829-0 Scheduled Maintenance Kit If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. 006186-0 Power Management Module (50 Amps) Power Management Modules are used in conjunction with the Smart Switch to increase its power management capabilities. It gives the Smart Switch additional power management flexibility not found in any other transfer switch. 006199-0 PMM Starter Kit The PMM Starter Kit consists of a 24 VAC, field installed transformer that enables the use of the 24 VAC Power Management Modules (PMMs) and one PMM. The standard controller (without starter kit) can control two HVAC loads with no additional hardware. This kit is required if installing this unit in a home with a digital HVAC controls vs. the standard 24 VAC system. Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. dimensions & UPC 637.6 mm [25.1 in] 1218 mm [47.9 in] UPC 006055-1 696471060553 006098-1 696471060980 731.9 mm [28.8 in] 642 mm [25.3 in] LEFT SIDE VIEW 1226 mm [48.3 in] FRONT VIEW Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0K8465-D Printed in U.S.A. 12/18/15