CO-220 Carbon Monoxide Meter



Similar documents
Temperature Humidity Meter

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

HVAC Clamp Meter. Users Manual

62 Max/62 Max + Infrared Thermometer

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

i410/i1010 AC/DC Current Clamp

How To Use The Visifault Visual Fault Locator

323/324/325. Calibration Manual. Clamp Meter

MicroScanner 2. Cable Verifier. Getting Started Guide

Sounding the Call Carbon Monoxide What You Need to Know

MICROMAPPER. Users Manual. LAN Wiremap Checker

Dual Laser InfraRed (IR) Thermometer

Alarms. State of Wisconsin Rules ss (2) and (3) Comm Comm


Dual Laser InfraRed (IR) Thermometer with Color Alert

80PK-27 SureGrip TM Industrial Surface Temperature Probe

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Dual Laser InfraRed (IR) Thermometer

el-720 Carbon Dioxide Gas Leak Detector User s Guide

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Multifunction Process Calibrator

EzFlex Combustible Gas Leak Detector Model EZ40

, User s Manual

10 Multimeter. Users Manual

Ultrasonic Distance Meter. Operation Manual

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Carbon Monoxide Alarm User s Guide

OWNER S MANUAL for Models:

High Temperature InfraRed Thermometer with Laser Pointer

Macurco CM-E1 Carbon Monoxide Detector

Microwave Meter. Instruction Manual

SL280UHV SERIES GAS FURNACE WARNING

Thermocouple Thermometer Models

Instant Ear Thermometer

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Carbon Monoxide Alarm User s Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

CO-9B User Manual CARBON MONOXIDE POISONOUS GAS ALARM

Carbon Monoxide Alarm User s Guide

4-Channel Thermometer / Datalogger

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Natural Gas Safety What You Need To Know

Thermistor Thermometer MODEL NO

Instant Ear Thermometer

Carbon Monoxide Alarm User s Guide

DSM155 Digital LED Light Meter User s Manual DSM155

Mold Alert... Operation Manual P0270

Amendment: Combustion Appliance Testing Standards Removal. Proponent: Brett Dillon, Chair Standards Development Committee

INSTRUCTION MANUAL DTH Fax: (503)

Professional Thermohygrometer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

600-GD & 600-GDL 600 SERIES GAS DETECTOR

ExStik TM ph Waterproof Meters

User Guide for the Kidde RemoteLync. Remote Notification Device

Owner s Guide. ca6554

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Weather Radio Alarm Clock

Fuels Safety Program FS DIRECTOR S PUBLIC SAFETY ORDER

Alarm Clock USER GUIDE

1 For All Non-Programmable Digital Thermostat

User's Guide Integrating Sound Level Datalogger Model

Fossil fuel heating equipment

Lockout Specification BW Clip Maintenance-free single gas detector

LPM-06 CONVERSION KIT

Carbon Monoxide Alarm User s Guide

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

How To Use A Power Supply Unit (Upu)

GAS FIREPLACE USER GUIDE ST900. NORTH AMERICA Ce manual est disponsible en Français _3_Manual_User_ST900_US_R-emotion

digital fever alert ear thermometer suitable from birth instruction manual

Natural Gas Safety. What You Need to Know

User's Guide. Pinless Moisture Meter. Model MO257

AutoRanging Digital MultiMeter

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Carbon Monoxide and Explosive Gas Alarm User s Guide

Ford/Lincoln Remote Access Android User s Guide

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Ford/Lincoln Remote Access iphone User s Guide

Having a gas appliance installed or serviced? Doing home improvements?

Manual Ranging MultiMeter

Hygro-Thermometer + InfraRed Thermometer Model RH101

HIH-4000 Series Humidity Sensors

Standardized Terminology for Combustion Appliances and. Combustion Safety Testing

Ground Resistance Clamp-On Tester

INTRODUCTION USER S MANUAL

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

BITMAIN. APW PSU Series User Guide

Model 77 Series IV Digital Multimeter

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model ABOUT THIS ALARM

Transcription:

Page 1 CO-220 Carbon Monoxide Meter Instruction Sheet Introduction The CO-220 Carbon Monoxide Meter (hereafter referred to as the Meter ) detects the presence of carbon monoxide (CO) and measures concentrations between 1-1000 parts per million (PPM). The Meter indicates the presence of carbon monoxide in two ways: By a reading on the LCD in PPM. By a beeper tone. Contacting Fluke To contact Fluke, call one of the following telephone numbers: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at: www.fluke.com. PN 690559 (English) May 1998 Rev.2, 4/04 1998-2004 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

Page 2 WSafety Information - Read First Do not use the Meter as a personal safety monitor. Learn and recognize the effects of CO poisoning. 0-1 PPM Normal background levels. 9 PPM ASHRAE Standard 62-1989 for living areas. 50 PPM OSHA enclosed space 8-hour average level.* 100 PPM OSHA exposure limit.* 200 PPM Mild headache, fatigue, nausea and dizziness. 800 PPM Dizziness, nausea and convulsions. Death within 2 to 3 hours. * U.S. Department of Labor, Occupational Safety & Health Administration (OSHA) Regulation 1917.24: The CO content in any enclosed space shall be maintained at not more than 50 PPM (0.005%). Remove employees from enclosed space if the CO concentration exceeds 100 PPM (0.01 %). What the Meter Does The Meter indicates the presence of CO by a reading on the LCD and a beeper tone. Above 1000 PPM, the LCD reads OL to indicate an out of range condition. The beeper functions much like clicking of a Geiger counter: The higher the concentration of CO, the faster the beeper sounds. Above 200 PPM, the beeper sounds continuously, while the frequency of the tone increases with the concentration of CO. Turning the Meter On Install the battery. (See Installing and Replacing the Battery. ) To turn the Meter on, press the green button. The Meter beeps twice, then performs a self-test. During the selftest, the display counts down from 10 to 0, while the Meter emits a series of 2 beeps followed by a pause. If the Meter passes the self-test, the Meter begins monitoring, which is indicated by a beep every two seconds, and shows a reading on the display.

Page 3 Self-Test The Meter tests the sensor and the battery each time it is turned on and continuously monitors the battery. If the battery is low, M is shown on the LCD. If battery power is below the level required to power the Meter, or if the sensor fails, the Meter emits a series of five beeps, followed by a long pause, and another series of five beeps. The Meter then turns itself off. If after replacing the battery, the alarm condition persists, the sensor may have failed. Contact an authorized Fluke service center for information on how to replace the sensor. Establishing a Baseline Before testing for CO, establish a baseline against which the Meter compares other environments. Do this by turning on the Meter. If the Meter detects between 0-3 PPM of CO, the beeper sounds and the Meter establishes a new baseline. If the Meter detects more than 3 PPM, it does not establish a new baseline, but starts taking CO measurements. Storing Maximum Readings (Max/Hold) In the Max/Hold mode, the Meter stores the maximum CO level it has detected. In this mode, the Meter continuously monitors the level of CO, which is indicated by the beeper, while displaying only the highest level detected on the LCD. To enable or disable the Max/Hold mode, press the MAX button; the beeper emits two quick tones when the Max/Hold mode is enabled and disabled. When the Max/Hold mode is enabled, MAX is shown on the LCD. Auto-Back-light If the ambient light is too low (making the LCD difficult to read), the LCD back-light automatically turns on. The back-light automatically turns off when sufficient light is present. Automatic Power-Off The Meter automatically turns itself off after 20 minutes.

Page 4 Muting the Beeper To mute the beeper, press the ON/OFF switch for more than 2 seconds when turning the instrument on. The mute beeper icon is shown on the display. To re-enable the beeper, turn the Meter off and then turn it back on. 1 5 MAX 2 3 MAX 4 8 7 6 NV001F.EPS A B C LCD (Liquid Crystal Display) Max/Hold button ON/OFF button D Sensor (Fluke PN 689497) E F G H Digital reading in parts/million (PPM) Max/Hold mode (display shows maximum reading) Low battery indicator Beeper turned off Fluke CO-220 Carbon Monoxide Meter

Page 5 Installing and Replacing the Battery 1 2 5 3 4 NV002F.EPS A B C D Screw Battery Door Battery, 9 V NEDA or IEC 6LR61, or equivalent Battery Connector E Sensor Common Sources of CO Common sources of potentially dangerous levels of CO are: Poorly maintained furnaces, gas heaters, or fireplaces. Dirty or plugged chimneys, or flue exhausts. Poorly maintained gas, oil, or kerosene appliances. Internal combustion engines (e.g., automobiles, lawnmowers, blowers).

Page 6 CO and Appliance Malfunctions The following table identifies typical problems that can produce high levels of CO. Appliance Fuel Typical Problems Gas furnaces Room heaters Oil, natural gas, or LPG (liquefied petroleum gas) 1. Cracked heat exchanger. 2. Not enough air to burn fuel properly. 3. Defective/blocked flue. 4. Maladjusted burner. 5. Building not properly pressurized. Central heating furnaces Room heaters Central heaters Water heaters Ranges Ovens Stoves Fireplaces Coal or kerosene Kerosene Natural gas or LPG Natural gas or LPG Gas, wood, coal 1. Cracked heat exchanger. 2. Not enough air to burn fuel properly. 3. Defective grate. 1. Improper adjustment. 2. Wrong fuel (not K-1). 3. Wrong wick or wick height. 4. Not enough air to burn fuel. 5. System not properly vented. 1. Not enough air to burn fuel properly. 2. Defective/blocked flue. 3. Maladjusted burner. 4. Building not properly pressurized. 1. Not enough air to burn fuel. 2. Maladjusted burner. 3. Misuse as a room heater. 4. System not properly vented. 1. Not enough air to burn fuel properly. 2. Defective/blocked flue. 3. Green or treated wood. 4. Cracked heat exchanger. 5. Cracked firebox.

Page 7 Specifications Temperature Operating: Storage: Humidity (non-condensing) < 3 weeks > 3 weeks Measurement range Measurement resolution Accuracy Sensor type Typical sensor life 0 o C to +50 o C -30 o C to +50 o C 0-99 % RH 0-90 % RH 0 to 1000 PPM 1 PPM for 0-200 PPM; 5 PPM for 200-1000 PPM 5 % or ± 2 PPM (whichever is greater) Stabilized electrochemical Gas-specific (CO) 3 years Temperature Coefficient Add 0.4 % per C > 25 C Add 0.6 % per C < 20 C Self Test Battery Typical battery life Certification < 20 seconds 9 V, NEDA 1604A or IEC 6LR61, or equivalent. 500 hours P

Page 8 Calibration or Service The Meter should be calibrated once a year by an authorized Fluke service center. During normal use, the Meter does not require adjustment. Any required adjustments are made at calibration. To replace the sensor, contact an authorized Fluke service center. Warranty LIMITED WARRANTY & LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke s behalf. To obtain service during the warranty period, send your defective tester to the nearest Fluke Authorized Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation Fluke Europe B.V. P.O. Box 9090 P.O. Box 1186 Everett, WA. 5602 B.D. Eindhoven 98206-9090 The Netherlands 10/96