Hematology Reagents and Controls Our products for your critical process



Similar documents
Preparation of Blood Films

STAINING OF PBF AND INTERPRETATION OF NORMAL AND ABNORMAL RED CELL MORPHOLOGY

R&D Systems Hematology Products

ABO-Rh Blood Typing With Synthetic Blood

MANUAL PLATELET COUNT

MANUAL WBC LAB OBJECTIVE

HumaCount System Line A Better Way to Connect. A Better Way to Work.

Pentra DX Nexus. Process efficiency in Hematology

BC Auto Hematology Analyzer

Functions of Blood. Collects O 2 from lungs, nutrients from digestive tract, and waste products from tissues Helps maintain homeostasis

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

XE-2100 Automated Hematology System. Fast, Accurate, Dependable

Color, True and Apparent

Color, True and Apparent

CAP Accreditation Checklists 2015 Edition

Urinalysis and Body Fluids CRg. Synovial Fluid. Synovial Fluid. Unit 4. Composition and formation. Functions. Reasons for analysis.

Phosphorus, Reactive (Orthophosphate)

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Exercise 9: Blood. Readings: Silverthorn 5 th ed, , ; 6 th ed, ,

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS


Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

COULTER A C T diff COULTER A C T diff 2

QUALITY CONTROL (QC) INFORMATION AND TROUBLESHOOTING GUIDE HEMATOLOGY

ABO-Rh Blood Typing Using Neo/BLOOD

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

Kemet DIAMOND PRODUCTS

Lab 02: Blood Cytology (20 points)

Automated Cerebrospinal Fluid Cytology

BY UV SPECTROPHOTOMETRY

HEMATOCRIT/HCT AND CALCULATED HEMOGLOBIN/HB

MANUAL PLATELET COUNT

EDUCATIONAL COMMENTARY RED BLOOD CELLS AND WHITE BLOOD CELLS IN URINALYSIS

Minneapolis User Group Meeting

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Quaternary Ammonium Compounds DOC

Class time required: Two 40-minute class periods + homework. Part 1 may be done as pre-lab homework

The Sievers 900 Series TOC Analyzers

Blood. Functions of Blood. Components of Blood. Transporting. Distributing body heat. A type of connective tissue. Formed elements.

Cardiovascular System. Blood Components

ab StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Level 1 Hematology Training Module For AcT Diff and AcT Diff 2

DR/4000 PROCEDURE. CHLORINE, Free

Measuring Protein Concentration through Absorption Spectrophotometry

n/a MYSTERY OF THE BLOOD STAIN (RE)

6 Characterization of Casein and Bovine Serum Albumin

SEED Haematology. Sysmex Educational Enhancement and Development February 2013

Keywords: RBC histogram, Peripheral blood smear, red cell disorders.

Factors Affecting Enzyme Activity

Position Classification Standard for Medical Technician Series, GS-0645

GIEMSA STAIN PREANALYTICAL CONSIDERATIONS

Mainstream retailer response to hard discount, an analysis of intra-store and interstore competition in EU!

Hematology Morphology Critique

Chapter 14 Urinalysis, Body Fluids and Other Specimens. Objectives:

LAB: Blood Exploration

Blood. Blood. Blood Composition. Blood Composition. Fractionation & Hemopoesis

Introduction to Flow Cytometry

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

KEY CHAPTER 14: BLOOD OBJECTIVES. 1. Describe blood according to its tissue type and major functions.

AIRMoN, ph and Conductivity Field Measurement

Appendix C. Vernier Tutorial

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Platelet Transmission Electron Microscopy and Flow Cytometry 11/15/2015

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

Preparation "Clinical Laboratory Technologist and Technician Overview"

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

ILLINOIS DEPARTMENT OF CENTRAL MANAGEMENT SERVICES CLASS SPECIFICATION CLINICAL LABORATORY TECHNICIAN SERIES

Catalytic Activity of Enzymes

UltraClean Soil DNA Isolation Kit

EXPERIMENT # 3 ELECTROLYTES AND NON-ELECTROLYTES

Scope and application: For testing residual corrosion inhibitors (oxygen scavengers) in boiler feed water or condensate

cobas 6500 urine analyzer series Fully automated urine work area on a modular platform

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

Bioprocessing Media and Buffers Grow with Us

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

Total Aerobic Bacteria, Yeasts and Molds

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Blood Stains at the Crime Scene Forensic Investigation

37 2 Blood and the Lymphatic System Slide 1 of 34

Validation and Calibration. Definitions and Terminology

Thrombin Generation Assay

Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians

Analytical Chemistry Lab Reports

FDA Public Hearing on Clinical Accuracy Requirements for Point of Care Blood Glucose Meters (BGMs)

March 19, Dear Dr. Duvall, Dr. Hambrick, and Ms. Smith,

Islet Viability Assessment by Single Cell Flow Cytometry

Calibration Verification

Annexin V-EGFP Apoptosis Detection Kit

PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

Laboratory 12 Blood Cells

Cell Cycle Phase Determination Kit

PRODUCT INFORMATION...

Blood, Plasma, and Cellular Blood Components INTRODUCTION

HAEMATOLOGY LABORATORY

Transcription:

Part of a pure process Hematology Reagents and Controls Our products for your critical process

2 Reagents you can count on

Mallinckrodt Baker s chemical expertise and 30 years of experience are the foundation of our J.T.Baker products for Hematology. We understand not only cell lysing and chemical interference of compounds on cell membranes, but also the characteristics of these compounds in aqueous solutions and their long-term behavior in the presence of other chemicals. Within our Hematology product line we offer a broad range of reagents for Hematology cell counters together with a variety of hematology controls to monitor daily accuracy and precision. In Hematology we offer: Reagents for cell analysers Hematology Controls Rapid Stat Manual Hemoglobinometry Staining in Hematology Our Hematology products are produced using state-of-the-art production and packaging techniques in modern certified manufacturing facilities. Quality Our products are designed and manufactured according to the following Quality systems: NEN-EN-ISO 9001 NEN-EN-ISO 14001 IVD Directive 98/79/EC; all our products that are subject to the Directive are registered and CE marked International Responsible Care; our contribution to environmental friendly and efficient manufacturing 3

Accountable Reagents for cell analysers Cymet J.T.Baker lysing reagents are available both as Cyanide (CN) free / SDS free solutions and as traditional cyanide containing reagents. The CN/SDS free reagents are non-poisonous and have shown to be more stable than the traditional reagents. This results in a longer shelf-life and a better stability after opening. J.T.Baker reagents for your cell-counter We offer a complete range of reagents for the majority of cell-counters on the market including 5 part differential models and automated reticulocyte counting instruments. The product range consists of: diluting fluids (Diluids) lysing reagents (CyMets) several types of rinsing and cleaning solutions Diluid Diluid is a specially filtered non-sterile blood diluting fluid for use in cell counting and sizing. The composition of the reagent maintains the stability of RBC s, PLTs and WBC s during counting. J.T.Baker Diluid is available to monitor five-part WBC differential analysis based on the laser light scattering principle. It can also be used for three-part differential analysis or non-diff applications. Diluid is stable for 3 years. Cleaners Mallinckrodt Baker supplies several cleaning and rinsing solutions, such as isotonic chemical cleaners, named DetectoTerge with surface active ingredients. The enzymatic cleaners ProClean and ProClean Plus contain proteolytic enzymes and are designed to be used for daily routine cleaning or for emergency cleaning. Hypochlorite solutions for effective clog removing are offered in several concentrations. Quality Control Together with testing for specifications such as ph, osmolality and conductivity, all reagent batches are performance tested to guarantee excellent suitability for the hematology analyzer. Packaging Diluids are packed in 5, 10 or 20 L polycubes CyMets are provided in 0.5 or 1 L HDPE bottles or 5 L polycubes Cleaners are offered in several packsizes Equipment dedicated bottles are also available. Suitable Convenient Consistent Complete Suitable A dedicated reagent set for each Hematology cell counter Consistent Raw materials all from an internal source Most lytic reagents are Cyanide and SDS free Convenient All diluting fluids are packed in easy to carry boxes Long shelf life and stability after opening Complete The current range covers over 50 different diluting, lysing and cleaning solutions for a wide range of cell analysers. 4

Hematology Controls for precision and accuracy Our range of Controls comprises 8-Parameter Controls for most instruments and differential Controls for various 3-part and 5-part differential analysis including reticulocyte counting. Daily use of the Controls provides quality control data to confirm the precision and accuracy of instrument operation. The Controls simulate whole blood and are available in abnormal Low, Normal and abnormal High levels. The products contain human red blood cells, simulated white blood cells and mammalian platelets, suspended in a plasma like fluid. All Controls are manufactured and delivered on a four or six times per year schedule, depending on their stability. Analysis of the Controls Suitable Convenient Consistent Complete Suitable: Assay values for the applicable instruments are provided with each lot and at www.mallbaker.com Vial volumes varying from 2.5 8 ml Convenient: Several packaging options with screw cap vials or pierceable vials Lot numbers have one month overlap of shelf life Consistent: Closed vials are stable for 3 or 4 months Open vial stability of 2 4 weeks Complete: The range covers non diff and differential controls for a wide range of cell-counters Specific Controls for blood bank applications Reticulocyte controls available Ordering information Controls Product Product Number Content Product Product Number Content Controls for all instruments (non diff) 8-Parameter Control L / N / H 3724/3725/3726 2.5 ml 8-Parameter Control L / N / H 3701/3702/3703 4.5 ml 8-Parameter Control L / N / H 3721/3722/3723 8 ml Controls for Bayer Advia ADV-Diff Control L / N / H 3684/3685/3686 3.5 ml ADV Retic 1 / 2 / 3 3690/3691/3692 4.0 ml Controls for Coulter 5 diff 5 D Control L / N / H 3681/3862/3683 5.0 ml Controls for Sysmex or Biochem K-Diff Control L / N / H 3896/3897/3898 2.5 ml XE-Diff Control L / N / H 3731/3732/3733 4.5 ml SE-Diff Control Low 3693/3694/3695 4.5 ml SE Retic 1 / 2 / 3 3666/3667/3668 3.0 ml Controls for Swelab AC-Diff Control L / N / H 3892/3893/3894 2.5 ml Controls for 3 part diff analysis 3-Diff Control L / N / H 3734/3735/3736 2.5 ml 3-Diff Control L / N / H 3820/3821/3822 4.5 ml Controls for Abbott CellDyn CD-Diff Control L / N / H 3828/3829/2830 3.0 ml CD 4K Retic 1 / 2 3687/3688 3.0 ml Controls for Medonic CA-Diff Control L / N / H 3607/3608/3609 2.5 ml CA-Diff Control L / N / H 3782/3783/3784 4.5 ml Controls for Diatron AJ 5 DIA-Diff 5 Control L / N/ H 3610/3611/3612 4.5 ml Other Controls Cal Set 1 3940 2 x 2.5 ml Laser Primer 3679 6 x 15 ml Laser Control 3680 6 x 15 ml Platelet Control extended value 3713 30 x 2 ml Platelet Control extended value 3720 15 x 2 ml WBC Reduced Plt Control L / H 3696/3697 3.0 ml WBC Reduced RBC Control L / H 3698/3699 3.0 ml Coagulation Control Level I / II / III 3710/3711/3712 24 x 1 ml Orders are guaranteed when received 9 weeks in advance. 5

Rapid Stat, quality control and assessment program J.T.Baker Hematology Controls Rapid Stat is a fast and convenient Quality Assessment program for hemocytometry. Users of all J.T.Baker Hematology Controls are allowed to participate in this external, between-lab and betweeninstrument statistical program. This free service is provided to inform users of our Controls about their individual performance compared to other users. Participation is easy. A new lot of Controls must be analyzed during 5 days. The results are sent by e-mail and within a few days a complete statistical report is received. The Rapid Stat report contains results per parameter for the current lot number and a cumulative review of the last 4 lot numbers. A comparison is made with your instrument group and with the total group of users of the same Control. Suitable Convenient Consistent Complete Suitable: All users of J.T.Baker Hematology Controls can use Rapid Stat Rapid Stat is instrument / manufacturer independent Multi instrument applicable Convenient: Fast: Send results and receive report by e-mail The Clinical part of our website www.mallbaker.com shows the Rapid Stat Reply Sheets Trends are visualized and easy to recognize Consistent: Participation in Rapid Stat is possible for each lot number 4 lotnumber history in each report Complete: Distribution histograms showing statistical distribution of the results of all users, your instrument group and your results The excentricity graphs present the confidence intervals per parameter Manual Hemoglobinometry For the manual analysis of Hemoglobin J.T.Baker offers a Concentrated Reagent and several Hemoglobin standards. The reagents are developed according to Van Kampen and Zijlstra. Ordering information Product Product Number Content Hb Reagent 20 ml for 1L 3060.0020 20 ml Hb Reagent 100 ml for 5L 3060.0100 100 ml HemiGlobin-Cyanide Standard 3061 10 x 10 ml HemoGlobin standard L / N / H 3074 4 x 3 x 0.5 ml HemoGlobin standard Normal 3075 12 x 0.5 ml 6

Staining in Hematology, bright and reliable May-Grünwald, Giemsa, Wright and Leishman These stains are used for tissue sections, cytology smears, blood smears and bone marrow. Our production methods and formulations are modified to the highest standards resulting in optimized color intensity. Hemacolour and Sørensen buffer Hemacolour is a fast, efficient and convenient staining method for blood smears replacing the traditional May Grünwald and Giemsa method. The procedure takes less than 1 minute and requires only 1 solution. To ensure the consistency it is advised to use Sørensen buffer instead of water. RetiCount For the identification of reticulocytes in blood smears and for counting the number of reti s per 1000 erythrocytes by microscopic analysis we offer RetiCount. Hemacolour staining method Documentation Through our website www.mallbaker.com or our specialized customer service department the following documentation about all our products is available: Material Safety Data Sheets (MSDS) Certificates of Analysis Specification sheets Validation reports Product information sheets Ordering information Stains Product Product Number Content Giemsa 3856 500 ml, 1L, 2.5L Hemacolour 3719 300 ml, 1L Leishman 3879 1L, 2.5L May-Grünwald 3855 500 ml, 1L, 2.5L RetiCount 3774 30 ml Sørenson Buffer 20x concentrated 3716 10 x 100 ml Wright 3878 1L, 2.5L More Information All our products are distributed through our worldwide network of distributors. Some reagents are only available through specified instrument dealers. For all our Hematology products, the Certificates of Analysis and the Material Safety Data Sheets, please access our Clinical business group on our website www.mallbaker.com or contact our Customer Service by telephone 0031 570 687500 or send us an e-mail at: jtbaker.nl@emea.tycohealthcare.com. 7

Part of a pure process How to contact Mallinckrodt Baker for your J.T.Baker Products Contact our international Customer Service at: Mallinckrodt Baker B.V. Teugseweg 20 P.O. Box 1 7400 AA Deventer The Netherlands T 0031 570 687500 F 0031 570 687574 E jtbaker.nl@emea.tycohealthcare.com Mallinckrodt Baker UK 107/112 Leadenhall Street London EC3A 4AH United Kingdom P 0044 1908 506 000 T 0044 1908 503 290 E jtbaker.uk@emea.tycohealthcare.com Mallinckrodt Baker Germany Im Leuschnerpark 4 D-64347 Griesheim Germany P 0049 6155 667 939 F 0049 6155 667 940 E jtbaker.de@emea.tycohealthcare.com Mallinckrodt Baker France 33 Avenue Phillipe Auguste 75011 Paris France P 0033 144 648 971/2 F 0033 144 648 973 E jtbaker.fr@emea.tycohealthcare.com Mallinckrodt Baker Italy Via P. Portaluppi 11/2 20138 Milano Italy P 0039 02 580 891 F 0039 02 580 19 264 E jtbaker.it@emea.tycohealthcare.com Visit us at: www.mallbaker.com 2006 Mallinckrodt Baker B.V. Deventer, The Netherlands. All rights reserved.