Motor Control Centers (MCC) Identification Guide. www.usa.siemens.com/mccaftermarket. Answers for industry.



Similar documents
Industrial OEM products

Product Guide. Low voltage grounding system. Answers for industry.

tiastar and legacy Motor Control Center Aftermarket Renewal Parts Catalog

MCC Ratings. Voltage Rating

Concentrating on the essentials: the new Basic Panels SIMATIC HMI. Answers for industry.

SPEEDFAX TM 2011 Motor Control Centers Contents

Easy. Modular. Universal. Laboratory automation with SIMATIC PCS 7 LAB SIMATIC PCS 7. Answers for industry.

Utility generation line card

System approach to archiving and reporting

Realize your full potential with the new version of SIMATIC PCS 7

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

siemens.com/scada SIMATIC SCADA Systems Efficient to a new level Answers for industry.

CENTERLINE 2100 Low Voltage Motor Control Centers

What ensures easy and fast wiring?

WinCC / PerformanceMonitor V7.2

Solutions for Process Analytics

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Services the Next Level. How Industry Services from Siemens help you discover a new source of competitive advantage. siemens.com/industry-services

The following components are common to most cubicles; this example is an ABB HK cubicle.

WinCC / PerformanceMonitor V7.3. Production analysis and improvement through individual key performance indicators. siemens.

New, ready to go and very simple! simotion easy set PACKAGING

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Your advantages at a glance

2008 Eaton Corporation. All rights reserved.

Expanding a 40-Type Cabinet

Quick Reference Guide Euro Style Terminal Blocks

SENTRON Switching and Protection Devices Air Circuit Breakers

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Force Measurement Systems. Force Measurement Systems

Extend and optimize the life of your plant the modular Life Cycle Service portfolio

Eagle Talon RetroFit Double-Hung and Picture Window Measuring Guidelines

Number 1 in efficiency

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Integrated engineering with COMOS and SIMATIC PCS 7

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL

CENTERLINE Motor Control Centers Splicing Horizontal Ground Buses

Motor repair and express motor delivery

LED MOTION ACTIVATED FLOOD LIGHT

5SV Residual Current Protective Devices

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

Quick Reference Guide AMP CT Connector Series

Pattern Co. Monkey Trouble Wall Quilt. Size: 48" x 58"

Your plant can do more with Industry Services. usa.siemens.com/services

GE Power Controls. MiniFORM Switchboards

Non-Stop Manufacturing Excellence. Automotive. Answers for industry.

3K Load-Break Switches The Program for Safety and Performance. sentric

BETA Protecting SITOR Semiconductor Fuses

Sample Table. Columns. Column 1 Column 2 Column 3 Row 1 Cell 1 Cell 2 Cell 3 Row 2 Cell 4 Cell 5 Cell 6 Row 3 Cell 7 Cell 8 Cell 9.

LED MOTION ACTIVATED FLOOD LIGHT

Electrical Distribution Services for Mining and Metals Industries

siemens.com/simatic-energy-management Energy Management with SIMATIC From data acquisition to company-wide energy management Answers for industry.

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

How can I manage all automation software tasks in one engineering environment?

Vilter motor starter solutions The NEW industry standard in motor starter packages

More efficiency and transparency? You can get there. Optimized Packaging Line. Answers for Industry.

Petrochemical Industry Ethylene Plant

An online dashboard in a snap

Variable Frequency Drives and Energy Savings

EDI Distributor Control Interface Wiring and Setup Instructions

Table of Contents. Review Answers...77 Final Exam...80

Simply follow the sun. up to Maximize the yields of solar power plants with solar tracking control

KwikSplice cable tray system Save up to 50% on material and installation time

Houston Service Center Medium Voltage Service and Aftermarket Solutions

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

Medical Air Systems: Scroll

Extend the Life of Existing Switchgear

Risk Mitigation of Aging Electrical Infrastructure

Square D Power Management Services. Complete Custom Solutions for Your Power System

1 & 2 CIRCUIT. Architectural grade ISO 9001 quality JIT availability Open architecture ready for your fixtures now!

Siemens ENEAS solutions for substation automation and protection

COMOS. The software solution for integrated plant management.

5,000 lb Capacity. Wireless Communication Scale

Software solutions from Integrated Engineering to Integrated Operations

Circuit Breakers. NRC Series. NRC Series

Professional services. Full service for your automation tasks. We automate your success.

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

SIMATIC Remote Services. Industry Services

SIMATIC PCS 7 takes you beyond the limits. SIMATIC PCS 7. Answers for industry.

Monitoring and diagnostics

Tank Terminals Proven Solutions for Liquid Bulk Storage and Distribution Terminals

General Purpose, Interposing, Solid-State and Specialty Relays. Bulletin 700

Utility Distribution Systems

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

NX for Tooling and Fixture Design Transforming today s processes for designing and manufacturing injection molds, dies and fixtures

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

Energy Efficiency Financing Unlock opportunities for additional sales. Supplier benefits. Financial Services provided by

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

DT Media Newsletter. New impetus for drive systems: Newly developed generation of geared motors provides a pivotal link for consistent drive solutions

FASTON Terminals and Connectors

CXQuotes Doors and Windows Quotation software. Cogitrix

Current Transformers Ratio / Polarity / Types

Transcription:

Motor Control Centers (MCC) Identification Guide www.usa.siemens.com/mccaftermarket Answers for industry.

Table of Contents Overview MCC Timeline 1 MCC Quick Identification Table 2 MCC Number Overview 3 Identification by Handle Type 4 Identification by Unit Stab 5 Siemens MCC Models tiastar 6 Model 95+ 7 Model 95 8 Model 90 9 Marq21 10 Furnas MCC Models System89 11 Class89 12 Allis-Chalmers Models Mark 2 13 Mark 1 14 ITE Models Gould 5600 15 Gould 9600 16 Request for Quote 17

MCC Timeline Siemens has an installed base of Motor Control Centers dating back to 1964 due to acquisitions of Allis-Chalmers in 1978, ITE Gould in 1983 and Furnas Electric in 1996. This has resulted in eleven MCC models installed across the United States. Replacement units for these models as well as the current tiastar MCC offerings are built in the Siemens West Chicago plant. Siemens developed this tool to help people gain a better understanding of the wide variety of this installed base of MCCs. This should enable people to order aftermarket buckets or new MCCs much easier. In this brochure, all the tools necessary for identifying existing MCCs are included. All items listed as follows: timeline, product overview, identification guide and product descriptions. The intent of this guide is to provide a tool for Siemens customers so they can make a more educated purchasing decision. If you have any questions, please contact your local Siemens representative. MCC Type MCC Timeline ITE Gould 9600 ITE Allis-Chalmers Mark 1 Allis-Chalmers Furnas Class 89 Furnas ITE Gould 5600 ITE Allis-Chalmers Mark2 Allis- Chalmers Siemens-Allis Marq21 Siemens-Allis Siemens Furnas System89 Furnas Siemens-Furnas Siemens Model 90 Siemens Siemens Model 95 Siemens Siemens Model 95+ Siemens Siemens tiastar Siemens 1964 1965 1971 1972 1975 1979 1980 1986 1990 1992 1993 1995 1996 1997 2001 2002 >2002 Year Note: Timeline represents approximate values 1

MCC Quick Identification Table This overview is a clear and concise snap shot of Siemens entire MCC product offering. For your convenience, typical MCC part numbers are shown for continued identification possibilities. Furthermore, the overview covers the standard options for the product offering. Original Manufacturer Model Production Dates Type of Handle Mechanism Typical MCC Serial Number Page Number 89BF#####-### Siemens tiastar 2002 Current Lever Siemens Model 95 + 1997 2001 Slider 89BS#####-### 89BB#####-### W#### 95BF#####-### 95BS#####-### 95BB#####-### #### 6 7 Siemens Model 95 1995 1997 Slider 09-001-####-#####-### 8 Siemens Model 90 1990 1997 Slider 30-001-####-##### 9 Siemens-Allis Marq21 1975 1990 Slider 01-14##-#####-## 10 Siemens/Furnas System89 1980 2001 Lever Same as Siemens tiastar 11 Furnas Class89 1965 1979 Lever 89FV####-### 89SV####-### 89BV####-### V#### 12 Allis-Chalmers Mark 2 1972 1975 Rotary ##### 13 Allis-Chalmers Mark 1 1965 1972 Slider ##### 14 ITE Gould 5600 1971 1992 Rotary 84-##### 15 85-##### ITE Gould 9600 1964 1971 Rotary 86-##### 16 2

Style (Serial)/Order Number Overview This visual guide will help you locate and identify your MCC by its order number or style number. Please note your unit s style or order number and report this when placing your order. This will help ensure the accuracy and timely completion of your request. Style (Serial) Number The style number can be found on the name plate of your MCC. This is generally located on the section of incoming power supply. Order Number The order number is an acceptable alternative to the style number. This can be found on the inside of a specific bucket. Please also report the unit number when possible (located below the order number). Note: Some older models may not have this sticker. 3

Identification by Handle Type tiastar (page 6) System89 (page 11) Model 95+ (page 7) Model 95 (page 8) Model 90 (page 9) Marq21 (page 10) Class89 (page 12) Marq21 (page 10) Mark 2 (page 13) Mark 1 (page 14) Gould 5600 (page 15) Gould 5600 (page 15) Gould 9600 (page 16) 4

Identification by Unit Stab tiastar (page 6) Model 95+ (page 7) System89 (page 11) Model 95+ (page 7) System89 (page 11) Model 95 (page 8) Model 90 (page 9) Marq21 (page 10) Class89 (page 12) Marq21 (page 10) Mark 2 (page 13) Mark 1 (page 14) Gould 5600 (page 15) Gould 9600 (page 16) 5

Siemens tiastar Introduced in 2002, Siemens tiastar Motor Control Center represents a rugged time proven design. Unit widths are normally 15 or 20 wide, and 12 tall with 6 increments. Label Identification Timeline: Original Mfg: MCC#: 2002 Current Siemens 89BF#####-### 89BS#####-### 89BB#####-### 6

Siemens Model 95+ The Model 95+ retrofit units are designed to fit into Model 95+ MCCs. This upgrade from Model 95 included changes in handles, color, pilot devices, and stabs. Unit widths are normally 15 or 20 wide, and 12 tall with 6 increments. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up. Label Identification Timeline: 1997 2001 Original Mfg: Siemens MCC#: 95BF#####-### 95BS#####-### 95BB#####-### 7

Siemens Model 95 Model 95 served as a style template for many old MCC units since installation procedures and dimensions stayed the same. Unit widths are normally 15 or 20 wide, and 12 tall with 6 increments. The original Model came with a variety of CB and starters from ITE, C-H and Siemens 3TF & 3UA Overload. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up. Label Identification Timeline: 1995 1997 Original Mfg: Siemens MCC#: 09-001-####-#####-### 8

Siemens Model 90 The Model 90 retrofit units are designed to fit into Model 90 MCCs. Unit widths are normally 15 or 20 wide, and 12 tall with 6 increments. The original Model 90 came with a variety of CB and starters from ITE, C-H, and Siemens 3TF and 3UA Overload. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up. Label Identification Timeline: 1995 1997 Original Mfg: Siemens MCC#: 30-001-####-##### 9

Siemens-Allis Marq21 The Marq21 retrofit units are designed to fit into Marq21 MCCs. Marq21 was created from the forge of two of the world s foremost electrical companies, Siemens-Allis. Units widths are normally 15 or 20 wide, and 12 tall with 6 increments. Original components are no longer available. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up. Label Identification Timeline: 1975 1990 Original Mfg: Siemens-Allis MCC#: 01-14##-#####-## Important Note: Models produced between 1982 1985 may feature a vertical bus phase isolation barrier. The Model 95 style retrofit buckets cannot be used due to interference with the bucket stabs. The unit will instead be supplied as a panelmounted unit that is cabled to the horizontal bus (cables are provided). 10

Furnas System89 This is an upgrade from Class89 developed by Furnas in 1965. Unit structures are normally 15 or 20 wide, and 12 tall with 6 increments. The original System89 came with a variety of CB and starters from Westinghouse, GE and Furnas Electric. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up. Label Identification Timeline: 1979 2001 Original Mfg: Furnas Electric MCC#: 89BF#####-### 89BS#####-### 89BB#####-### 11

Furnas Class89 Original components are no longer available. Replacement units are no longer available. A new tiastar MCC can be cabled to an existing line up with an MLO assembly. Label Identification Timeline: 1965 1979 Original Mfg: Furnas Electric MCC#: 89FVXX###-### 89SVXX###-### 89BVXX###-### 12

Allis-Chalmers Mark 2 The Mark 2 retrofit units are designed to fit into their old design. This is an upgrade from the Mark 1 in ValueLine family. Unit widths are normally 15 or 20 wide, and 12 tall with 6 increments. The original Mark 2 came with a variety of CB and starters from Westinghouse and Allis-Chalmers. Original components are no longer available. Today, we provide you with Siemens breakers and starters. Add-on MCCs: A new tiastar MCC can be directly spliced to existing line-up. Timeline: 1972 1975 Original Mfg: Siemens MCC#: ##### 13

Allis-Chalmers Mark 1 Original components are no longer available. Replacement units are no longer available. A new tiastar MCC can be cabled to an existing line up with an MLO assembly Timeline: 1965 1971 Original Mfg: Allis Chambers MCC#: ##### 14

ITE Gould 5600 The 5600 MCC retrofit units were designed to fit into their old design. Units are 15 wide and the fix mounted panels are 20 wide. Original components are not longer available. Today we provide you with Siemens starters and breakers. Note: Units can be provided as a fix-mounted unit cabled to the horizontal bus, or as a plug-in unit. Add-on MCCs: A new tiastar MCC can be cabled to an existing line up with an MLO assembly. Label Identification Timeline 5600: 1971 1992 Original Mfg: ITE / Rowan Control MCC#: 84-##### 85-##### 86-##### 15

ITE Gould 9600 The 9600 MCC retrofit units were designed to fit into their old design. Units are 20. Original components are no longer available. Today we provide you with Siemens breakers and starters. Note: Units can be provided only as a fix-mounted unit cabled to the horizontal bus. Add-on MCCs: Replacement units are not available. A new tiastar MCC can be cabled to an existing line up with an MLO assembly. Label Identification Timeline: 1964 1971 Original Mfg: ITE / Rowan Control MCC#: 84-##### 85-##### 86-##### 16

Request for Quote To request a quote for aftermarket MCC units, please visit www.usa.siemens.com/mccaftermarket 17

Siemens Industry, Inc. Industry Automation Division 3333 Old Milton Parkway Alpharetta, GA 30005 1-800 -241-4453 Subject to change without prior notice. Order No: CCBR-MCCAR-0813 All rights reserved. Printed in USA 2013 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. info.us@siemens.com www.usa.siemens.com/mccaftermarket All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.