Vitodens 200, B2HA / B2HB - Product Introduction

Similar documents
Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W

Modern Gas Heating. The Vitodens 200 gas-fired condensing boiler is prepared for the use of conditioned biogas.

Vitocaldens 222-F Compact Gas-Hybrid appliance

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F

Flame Conductivity VS Flame Rectification Systems

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F

Technical Data Manual

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

RECON WATER HEATER INSTALLATION FORM

Better Boilers.

Oil/gas boilers for medium and high output

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

NAVIEN AMERICA INC FITCH AVENUE

SOLI TANKLESS PRODUCT GUIDE

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

Buderus. Flexible Energy Efficient Solutions. Comfortable. Efficient. Intelligent Heating. GB312 Series Natural Gas Condensing Boiler.

Cooling Capacity CFM in. w.c. (125 Pa)

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Commercial heating with oil and gas

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

HEAT INTERFACE UNITS (Modular)

Cooling Capacity CFM in. w.c. (125 Pa)

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

DESIGNER S HIGH EFFICIENCY GUIDE SYNC COMMERCIAL BOILERS. Up to 98% Thermal Efficiency.

TANKLESS DURABILITY Tankless Product Guide

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Cooling Capacity CFM in. w.c. (125 Pa)

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

FTQ. Daikin Inverter Ducted Heat Pump

Commercial Boiler Systems and Controls

G234X-55 Conventional Gas Boiler

Electric Flow Boiler

Commercial Gas Water Heater

Operating instructions

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Commercial Gas Furnace Upflow

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

ELECTRIC CENTRAL HEATING FLOW BOILER

Fossil fuel heating equipment

PART 11: START-UP PROCEDURES FOR THE INSTALLER

High efficiency, cast-iron gas boiler

HEAVY DUTY STORAGE GAS

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Gas Boilers - Commercial

Originators of the Flexible Water Tube design

Commercial Gas Water Heaters

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

VIESMANN. VITODENS Gas condensing boiler 1.9 to 35.0 kw. Technical guide. VITODENS 200-W Type B2HA, B2KA. VITODENS 222-W Type B2LA

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Spare Parts List M96A.24SM/B M96A.28SM/B

VIESMANN. VITODENS Gas condensing boiler 3.8 to 35.0 kw. Technical guide. VITODENS 200-W Type WB2C. VITODENS 222-W Type WS2B. VITODENS 300-W Type WB3D

High Efficiency Boiler Range Technical Guide

Technical Data Manual Model Nos. and pricing: see Price List

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

F9MXE. Product Specifications

FTXS. Wall Mount Heat Pump or Cooling Only

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

RPV - RP - RA air handling units

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

G9MXE. Product Specifications

Commercial Gas Water Heaters

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Logamax plus GB142. Applications Manual. Gas condensing boiler

Installation Instructions for use by heating contractor. VITODENS r 222-F IMPORTANT. Read and save these instructions for future reference.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

ECOCIAT. Domestic hot water heat recovery unit

Commercial Gas Water Heaters

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

ROTEX gas hybrid heat pump. A strong team.

Buderus. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. G315 G515 G615 Cast Iron Commercial Boilers.

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

presents Hydraulic Separation Beyond Primary / Secondary Piping

COMBIMASS. Technical Data COMBIMASS eco-bio +

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

UDSA - UDSBD unit heater

FHQ. Ceiling Suspended Heat Pump or Cooling Only

Conlift1, Conlift2, Conlift2 ph+

User's Instructions. Alpha HE CB25/33 and HE SY25

Boiler Applications Drawings

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Vacuum drying oven for non-flammable solvents

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Principals of Condensing Boiler System Design

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Apartment and Communal Heating Solutions

Transcription:

- Product Introduction

Foil 2, 10/2015 Viessmann Manufacturing Wall Mounted, Gas-Fired Condensing Boiler

Foil 3, 10/2015 Viessmann Manufacturing A member of the Viessmann family of heating products Condensing boilers System controls Solar systems DHW tanks AirFlowPLUS Hydronic Air Handler

Foil 4, 10/2015 Viessmann Manufacturing Vitodens Boiler History Vitodens 200, WB2A 2000 2009 Vitodens 200, WB2B 2009-2012 Vitodens 200, B2HA B2HB 2013 to today

Foil 5, 10/2015 Viessmann Manufacturing Vitodens Boiler Family Today Vitodens 100, WB1B 2 sizes 37-118 MBH 10 sizes 12-530 MBH Vitodens 222-F, B2TB 2 sizes 12 125 MBH

Foil 6, 10/2015 Viessmann Manufacturing Features: Wall mounted gas-fired condensing boiler 10 sizes: from 68 MBH to 530 MBH Stand alone or multi-boiler Fuel saving, highly efficient condensing operation Up to 95% A.F.U.E efficiency Compact design and modern appearance Zero clearance to combustibles Whisper quiet operation Fast and easy to install, simple to service Flexible venting options

Foil 7, 10/2015 Viessmann Manufacturing Features: InoX-Radial corrosion resistant stainless steel heat exchanger λ - Pro MatriX-Cylinder burner (NG or LP) Full modulation with up to 6.6:1 turndown Low NOx emissions < 20 ppm High altitude operation up to 10,000 FASL Lamda Pro Combustion Technology

Foil 8, 10/2015 Viessmann Manufacturing Features: Vitotronic 200, HO1B boiler control with black interface for easy programming and set up Comes internet ready for: Vitocom 100 LAN1 module and Vitotrol App Vitogate 300 for BMS network integration Full line of Viessmann System Technology accessories available: Low Loss Headers Mixing valve and actuators Remote controls Custom control panels Boiler stands

Foil 9, 10/2015 Viessmann Manufacturing Benefits: Long service life Lowest possible fuel consumption Reliability: Proven Viessmann Heat Exchanger, Burner and Control designs Suitable for a wide range of applications from small condo, to custom home, to large commercial Perfect for multi-temperature heating + DHW systems Fast and easy to set-up and service

Foil 10, 10/2015 Viessmann Manufacturing Vitodens 200, B2HB Five Sizes Available Natural Gas Capacities - MBH B2HB-19 B2HB-26 12 68 19 94 B2HB-35 B2HB-45 19 125 32 160 B2HB-57 32 199 Notes: Different Min. inputs for LPG

Foil 11, 10/2015 Viessmann Manufacturing Vitodens 200, B2HA Five Sizes Available Natural Gas Capacities - MBH B2HA-80 71 285 B2HA-88 71 311 B2HA-100 B2HA-112 71 352 113 399 B2HA-150 113 530 Notes: Input must be de-rated for high altitude. Different Min. inputs for LPG

Foil 12, 10/2015 Viessmann Manufacturing Multi-Boiler Cascade up to 8 boilers For systems up to 8 boilers With Vitotronic 300K, MW2C Cascade Control Common venting up to 4 boilers Total capacity up to 4,240 MBH

Foil 13, 10/2015 Viessmann Manufacturing Specifications Model Overall Dimension D W H B2HB- 19 15.7 17 ¾ 41 B2HB- 26 15.7 17 ¾ 41 B2HB- 35 15.7 17 ¾ 41 B2HB- 45 21 19 43 ½ B2HB- 57 21 19 43 ½ B2HA- 80 21 19 43 ½ B2HA- 88 21 19 43 ½ B2HA- 100 21 19 43 ½ B2HA- 112 27.1 23 5/8 44 ½ B2HA- 150 27.1 23 5/8 44 ½ Weight 110 lbs 110 lbs 110 lbs 210 lbs 210 lbs 194 lbs 194 lbs 194 lbs 298 lbs 298 lbs Heating S/R Connections ¾ ¾ ¾ 1 ½ 1 ½ 1 ½ 1 ½ * 1 ½ 2 2 * PRV ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ Drain ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ Gas ¾ ¾ ¾ 1 1 1 1 1 1 1 W= 17.7 W = 19 W = 23.6 D=15.7 D = 21 D = 27

Foil 14, 10/2015 Viessmann Manufacturing Pressure And Temperature Model Maximum working pressure B2HB- 19 B2HB- 26 B2HB- 35 B2HB- 45 B2HB- 57 B2HA- 80 B2HA- 88 B2HA- 100 B2HA- 112 psig 45 45 45 60 60 60 60 60 80 80 B2HA- 150 Maximum working temperature F (C) 165 (74) 165 (74) 165 (74) 165 (74) 165 (74) 176 (80) 176 (80) 176 (80) 180 (82) 180 (82) Need higher working temperature? Vitocrossal 300, CU3A Max. Temperature 194 o F (90 o C)

Foil 15, 10/2015 Viessmann Manufacturing Rated Efficiencies Model B2HB- 19 B2HB- 26 B2HB- 35 B2HB- 45 B2HB- 57 B2HA- 80 B2HA- 88 B2HA- 100 B2HA- 112 B2HA- 150 A.F.U.E. 95.0 95.0 95.0 95.0 95.0 92.0 CSA Thermal /Combustion Efficiency *1 94.5 94.5 93.9 93.5 Standards tests prove the Vitodens 200 B2HA / B2HB boiler to be among the most efficient in the industry. *1 Tested to U.S. Standards ANSI Z21.13/CSA 4.9.

Foil 16, 10/2015 Viessmann Manufacturing Efficiency % Boiler Efficiencies vs Return Water Temperature 100% Boiler Efficiency Curve 98% 96% 94% 92% 90% 88% Boiler return water temperature determines condensing boiler efficiency 86% 70 80 90 100 110 120 130 140 150 Return Temperature o F

Foil 17, 10/2015 Viessmann Manufacturing Extremely Quiet Operation Matrix burner has very quiet operation Usual operation at less than 45dB (with the front cover installed) WOW! A boiler that s quieter than a typical refrigerator. Model 19 26 35 45 57 80 88 100 112 150 At MIN burner input At MAX burner input db 35 36 36 39 39 38 38 38 40 40 db 41 48 51 56 67 56 69 69 57 61

Foil 18, 10/2015 Viessmann Manufacturing Construction Details Flue gas outlet InoX-Radial stainless steel boiler heat exchanger Boiler S/R piping (connections at bottom of boiler) MatriX cylinder burner with Lambda Pro combustion technology Condensate P-trap and drain pipe Vitotronic control with user friendly interface

Foil 19, 10/2015 Viessmann Manufacturing Easy To Install Wall mounted wall with bracket Boiler stand For wall support or freestanding

Foil 20, 10/2015 Viessmann Manufacturing Multi-Boiler Cascade up to 8 boilers Optional multi-boiler manifolds and large Low Loss headers available One manifold size for all B2HA models from 45-150

Foil 21, 10/2015 Viessmann Manufacturing Multi-Boiler Cascade up to 8 boilers Optional multi-boiler manifolds and large Low Loss headers available One manifold size for all B2HA models from 45-150 2 and 3 boiler manifolds: Multiple configurations Corner or back to back

Foil 22, 10/2015 Viessmann Manufacturing Piping Connections For 19-150 kw All fittings are NPT for all sizes NEW! Thermometer (not shown) is now included in the fitting kits for the boiler supply. PRV: GC: BD: BF: DS: DR: BS: BR: Pressure Relief Valve Gas Connection Boiler Drain Boiler Fill DHW Supply DHW Return Heating Supply Heating Return

Foil 23, 10/2015 Viessmann Manufacturing Condensate Traps Easy to service condensate traps. B2HB 45-57 kw B2HA 80-150 kw B2HB 19-35 kw To drain To drain To drain

Foil 24, 10/2015 Viessmann Manufacturing Access To The Control Panel Control Panel tilts down for easy access for: Temperature sensor wiring Communication boards Fuses

Foil 25, 10/2015 Viessmann Manufacturing Control Board Tipped Down Shown with back cover removed Sensor inputs: #1 Outdoor temperature #2 Low Loss Header Ionization signal Fuse KM Buss LON Communication Card

Foil 26, 10/2015 Viessmann Manufacturing Power / Pump Module Wiring Enclosure Located in a swing down enclosure at bottom of boiler, below the controller interface.

Foil 27, 10/2015 Viessmann Manufacturing Power / Pump Module Wiring Enclosure Swing down the connection box.

Foil 28, 10/2015 Viessmann Manufacturing Power / Pump Module Wiring Enclosure Modules inside wiring enclosure EA1 Module Power / Pump Module

Foil 29, 10/2015 Viessmann Manufacturing Inox-Radial Heat Exchanger High grade SA240-316Ti Stainless Steel. Excellent corrosion resistance Excellent heat transfer Easy to clean No special system fluid fill or ph Developed and manufactured by Viessmann in Germany Time tested reliability for over 15 years

Foil 30, 10/2015 Viessmann Manufacturing Inox-Radial Heat Exchanger Condensation occurs on the outside of coil The entire surface is condensing! Self-cleaning on condensing surface of heat exchanger

Foil 31, 10/2015 Viessmann Manufacturing Inox-Radial Heat Exchanger Flue gas Precise 0.8 mm gaps for highly intensive heat transfer Supply Sensible and latent heat extracted Hot flue gas 1650 o F MatriX Cylinder Burner Water 86 o F Return Cool flue gas 115 o F Condensate drain

Foil 32, 10/2015 Viessmann Manufacturing Vitodens 200, B2HB Heat Exchanger Update For Sizes 19 to 57 New baffled Inox-Radial design maintains full condensing surface. Fully self cleaning behind centre refractory disc (does not need to be removed when servicing the boiler) Vent connection Heat Exchanger Burner Refractory disc Condensate drain

Foil 33, 10/2015 Viessmann Manufacturing Vitodens 200, B2HB Heat Exchanger Update For Sizes 19-57 Increased heat transfer surface area at rear of HX enhances the full condensing effect Temperature Direction of flue gas flow 845 743 641 540 438 336 234 132

Foil 34, 10/2015 Viessmann Manufacturing Vitodens 200, B2HA Inox-Radial Heat Exchanger for sizes 80, 88, and 100 Two coils One HX Inter-twined

Foil 35, 10/2015 Viessmann Manufacturing Vitodens 200, B2HA Inox-Radial Heat Exchanger for sizes 80, 88, and 100 2 circuit heat exchanger design T T Isolation valves Dual redundant thermistors Internal to boiler External pump Flow switches Heating system Low Loss Header

Foil 36, 10/2015 Viessmann Manufacturing Vitodens 200, B2HA Inox-Radial Heat Exchanger for sizes 112 and 150 Multi circuit heat exchanger design Air venting ridge Supply ports Manual air bleed Return ports Ultrasonic flow sensors Heating supply Gas Heating return

Foil 37, 10/2015 Viessmann Manufacturing Vitodens 200, B2HA InoX-Radial-Heat Exchanger 112kW 150kW

Foil 38, 10/2015 Viessmann Manufacturing Matrix Cylinder Burner Fully modulating burner Up to 6.6 :1 turndown Natural gas or LP gas Lambda Pro Technology Low NO x emissions (< 20 ppm) Easy to setup and service

Foil 39, 10/2015 Viessmann Manufacturing Matrix Cylinder And Dome Burners Matrix-cylinder 6,8 to 2,230 MBH Matrix-dome 6,8 to 1,110 MBH Developed and manufactured by Viessmann. Used for floorstanding and wallhung boilers for over 15 years Production Plant Viessmann Allendorf

Foil 40, 10/2015 Viessmann Manufacturing Matrix Cylinder Burner Lambda Pro Technology: What is it? Self calibrating burner and combustion management Automatic adjustment to varying gas quality / conditions Ensures optimum combustion and constant high efficiency at all times Easily adjusts to NG or LP

Foil 41, 10/2015 Viessmann Manufacturing Matrix Cylinder Burner Lambda Pro Technology: How it works: Controls gas and air independently of each other Ionization current indicates flame quality Gas and air control constantly adjusts to changes No field adjustments required

Foil 42, 10/2015 Viessmann Manufacturing Lambda Pro Technology Benefits : Always optimum combustion Benefits for Boiler Owner: Constant high efficiency, safety and comfort Automatically adjusts to varying gas quality Low susceptibility to interference Vitocrossal 300 Vitodens 222-F Vitodens 200 Automatic adjustment to the gas quality Benefits for Installer: Simple, fast commissioning No field adjustments or calibration required Easy adjustment for NG or LPG Changes in Gas supply structure = fluctuating gas quality Fracking Shale gas LNG Bio-gas Combustion control is the answer to future developments of gas quality

Foil 43, 10/2015 Viessmann Manufacturing Natural Gas or LP Gas Operation Boilers are factory adjusted for Natural Gas No additional parts needed for conversion to LP Gas. Easy conversion to LP: ¼ turn on gas valve set screw Change two addresses in Coding 2 A combustion setting adjustment is not normally required Gas Pressure requirements: B2HA/B All models Min Press. NG Min Press. LPG Max Press. NG/LPG 4 wc 10 wc 14 wc

Foil 44, 10/2015 Viessmann Manufacturing Integrated Vitotronic 200, HO1B control Built-in multi-function outdoor reset boiler and system control Clear text display and graphic support Multi-temperature space heating and DHW controller: 1 high temperature heating circuit 2 low temperature heating circuit Domestic hot water priority function Integrated digital clock with daily and weekly program Easy communication with BMS or Internet: Vitocom 100 LAN1 Internet communication Vitogate 300 BMS Gateway

Boiler supply temperature o C Vitodens 200, B2HB Foil 45, 10/2015 Viessmann Manufacturing Integrated Vitotronic control Weather responsive control automatically adapts boiler water supply temperature to changing outdoor temperatures Reduced fuel consumption by up to 15% per year Provides enhanced comfort for occupants Outside temperature sensor Outside temperature o C Boiler supply

Foil 46, 10/2015 Viessmann Manufacturing Integrated Vitotronic control Bright white text on black background for easy to read information. Easier to use with more intuitive programming functions, graphically displayed information & more features. Main home screen

Foil 47, 10/2015 Viessmann Manufacturing Integrated Vitotronic control Easy to navigate with plain text and graphics Setback timers Heating curve adjustment Change units

Foil 48, 10/2015 Viessmann Manufacturing The Viessmann System Approach Vitotrol 200/300 Communication Thermostat Vitotronic Boiler and System Control Mixing valves + Motorized actuating motors

Foil 49, 10/2015 Viessmann Manufacturing Vitogate 300 - BAS Communication Gateway BAS Management Layer System Integration Layer BACnet / Modbus communication controller Vitogate 300 Two versions available: LON to BACnet. LON to Modbus. LON LON LON Mechanical System / Device Layer Vitocrossal 200, CM2 with GW6B Vitodens 200 with or without MW2C Other Viessmann boilers with Vitotronic boiler controllers

Foil 50, 10/2015 Viessmann Manufacturing Internet communication with Vitocom 100 LAN1 module LON LAN* LON-Module Vitocom 100 LAN1 Router Internet Vitotrol App *Vitocom 100 must be wired with LAN cable to router

Foil 51, 10/2015 Viessmann Manufacturing Multiple venting options Venting made easy with multiple vent material options Pipe in pipe Coaxial PPs Separate flue gas and combustion air openings on boiler Approved materials: Coaxial PPs Rigid PPs Flexible PPs CPVC Stainless Steel Equivalent lengths up to 180 ft. Single wall pipe: PPs Rigid PPs Flexible CPVC Stainless steel

Foil 52, 10/2015 Viessmann Manufacturing Vitodens 200, B2HB Venting Connections On The Boiler 19 35kW Combustion Air connections at A Flue Gas connection at B B B A A Cover A A 2 pipe option Coaxial or room air dependent option

Foil 53, 10/2015 Viessmann Manufacturing Venting Connections On The Boiler 45 150kW Combustion Air connections at A B A Flue Gas connection at B A B Coaxial or room air dependent option 2 pipe option

Foil 54, 10/2015 Viessmann Manufacturing Venting Layouts Supported Coaxial, (concentric) Vertical Horizontal Flue gas Combustion air

Foil 55, 10/2015 Viessmann Manufacturing Venting Layouts Supported Coaxial, (concentric) Vertical Horizontal Two Pipe Vertical Horizontal Hybrid

Foil 56, 10/2015 Viessmann Manufacturing Venting Layouts Supported Coaxial, (concentric) Vertical Horizontal. Two Pipe Vertical Horizontal Hybrid Single Pipe (room air dependent) Vertical Horizontal

Foil 57, 10/2015 Viessmann Manufacturing Venting Layouts Supported Coaxial, (concentric) Vertical Horizontal. Two Pipe Vertical Horizontal Hybrid Single Pipe (room air dependant) Vertical Horizontal Flexible with PPs

Foil 58, 10/2015 Viessmann Manufacturing Common Venting For Multiple Boiler Installations Up to four boilers into one common vent Multiple combustion air options: Room air dependent Individual boiler intake Common intake (up to four boilers) Vertical vent termination only

Foil 59, 10/2015 Viessmann Manufacturing Piping Layout Options Low mass boiler construction requires minimum boiler flow rate Dedicated boiler pump with hydraulic separation is required Primary-secondary piping with closely spaced tees, or Low loss header Option 1: Closely spaced Tees Option 2: Low Loss Header

Foil 60, 10/2015 Viessmann Manufacturing Piping Layout Options Space heating with multiple zone pumps DHW heating with priority LLH

Foil 61, 10/2015 Viessmann Manufacturing Piping Layout Options Multi-temperature (2) space heating DHW heating with priority LLH

Foil 62, 10/2015 Viessmann Manufacturing Piping Layout Options Multi-temperature (3) space heating Multiple motorized mixing valves DHW heating with priority LLH

Foil 63, 10/2015 Viessmann Manufacturing Piping Layout Options Multiple boilers Multi-temperature (2) space heating DHW heating with priority LLH

Foil 64, 10/2015 Viessmann Manufacturing Everything You Need In A Heating Boiler Suitable for a wide range of residential / commercial applications Cascade up to 8 boilers Highly efficient operation for dramatic fuel savings Powerful multi-function heating + DHW system controller Durable, reliable and long service life with stainless steel construction NG /LPG burner with Lambda Pro Technology Whisper quiet operation Flexible venting options Easy to service and maintain

- Product Introduction