A Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1)



Similar documents
Safety Storage Cabinets

FLAMMABLE LIQUIDS COMPLIANCE NOTE

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Flammable Liquids Storage

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Flammable Liquids Storage

English Version. Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Controlling fire and explosion risks in the workplace

Certain specific properties of compressed gases make them highly useful in various research activities.

Wilkins Safety Group

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING SULPHURIC ACID DRAIN CLEANER

SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES

Liberty Mutual Insurance RISK ENGINEERING PROCEDURE. REP 07 Incident Planning For external use

Fire safety in buildings and implementation of European fire test standards

Queen's University Environmental Health and Safety

Laboratory Work Risk Assessment

PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

LPG, Flammable Liquids, Toxic and Corrosive Substances

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

CHEMICAL SPILL MANAGEMENT GUIDELINES

HealthandSafetyOntario.ca. What is a work permit? Why use a work permit? Types of work permits. When is a work permit needed?

BEDFORDSHIRE FIRE AND RESCUE SERVICE FIRE SAFETY GUIDANCE NOTE NO 40

Propane Fuel. Material Safety Data Sheet

Process Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices

Fire Safety Risk Assessment Checklist for Residential Care Premises

The dangers of cellulose nitrate film

Guidance for Those Who Use and Store Gas Cylinders

Work Permits. A Health and Safety Guideline for Your Workplace. When is a Work Permit Needed? What is a Work Permit? Why use a Work Permit?

OSHA Office of Training and Education 1

HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING

Hazardous Substances and New Organisms Act 1996

Compressed Gas Cylinder Program

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

Fume Hood Questions and Answers

Risk Assessment. Module 1. Health & Safety. Essentials November Registered charity number

Product Code: VLB ml cartridges. Substance Name EC No. CAS No. % by Wt Hazard Symbols n Butylacetate

Material Safety Data Sheet

An inventory of hazardous materials used in your workplace will prove useful.

Section III Hazardous Materials Management

PEROXIDE SAFETY DATA SHEET (60% H2O2) Safety Data Sheet

Work Health and Safety Regulations: Classification and labelling for workplace hazardous chemicals

This leaflet provides information on

*** SAFETY DATA SHEET ***

ENVIRONMENT, SAFETY, HEALTH, AND QUALITY DIVISION

Guide to Certification for Retail Hardware Stores

Material Safety Data Sheet Ampicillin, sodium salt MSDS

Compressed Gas Cylinder Storage and Handling Guide

Safety and Health Office WORKPLACE SAFETY CHECKLIST

Safe Use of Flammable and Explosive Substances: A Guide to DSEAR in the University. Safety and Environmental Protection Services

Put us to the test. Construction testing and building investigations services from BRE.

MATERIAL SAFETY DATA SHEET

1.0 Purpose Definitions Hot Work Operations. 5

Presented by: Rich Perry Marsh Risk Consulting

BRO Roles & Responsibilities Form Page 1 of 9

5162 E. Working in oxygen-reduced atmospheres BGI/GUV-I 5162 E. Information

FIRE SAFETY ONLINE TRAINING

Site and Storage Conditions for Class 3.1 Flammable Liquids

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Date: 22 June 2005 Version: 2 Revision: Identification of the substance/preparation and company/undertaking

LABORATORY SAFETY INSPECTION CHECKLIST

Creation Date: Revision Date: Page: 1 of 7

For the Design, Installation, Commissioning & Maintenance of Fixed Gaseous Fire Suppression Systems

Fire and Rescue Service Operational Guidance. GRA 5.8 flashover, backdraught and fire gas ignitions

Flammable and Combustible Liquids. Slide 1 (of 23)

The dangers of cellulose nitrate film

SOLVENT CLEANER MSDS Page 1 of 5 SAFETY DATA SHEET. (To comply with OSHA s Hazard Communication Standard 29CFR /ANSI z400.

Fire Risk Assessment Safety Checklist

Confined spaces can be deadly. What is a confined space?

LABORATORY & CHEMICAL SAFETY GUIDELINES. Dr. Mobin Shaikh Convener SAFETY COMMITTEE DISCIP INE OF CHEMISTRY SCHOOL OF BASIC SCIENCE

Flammable Liquids 29 CFR

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

Material Safety Data Sheet

SAFETY DATA SHEET. according to 1907/2006/EC, Article 31 CYTOFIXX (CYTOLOGICAL FIXATIVE)

Dear Business Manager,

Material Safety Data Sheet

Material Safety Data Sheet

Mechanical Systems Competency 1.20

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

Take care with oxygen Fire and explosion hazards in the use of oxygen

MATERIAL SAFETY DATA SHEET Description: SAF DRAIN Revision Number: 00

Technical Data Sheet

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Grey Nuns Community Hospital. Chemical Spill / Hazardous Material

Safety Data Sheet Avesta Neutralization Agent 502

IGEM/UP/16 Communication 1756

WHMIS After GHS: Preparing for Change. Canadian Centre for Occupational Health and Safety

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Generic risk assessment form. This document forms part of Loughborough University s health and safety policy Version 3 February 2014

Globally Harmonized System Pictogram Reference Table

The EU-GHS Hazard statements in English (Precautionary statements: from page 5)

RPV - RP - RA air handling units

Safety Data Sheet Customwood MDF

BUSINESS LICENSE (2014) CHARTER TOWNSHIP OF FLINT 1490 S. DYE ROAD, FLINT Ml (810) OR FAX (810)

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Lone Working Guidance

Storage of flammable liquids in containers

Transcription:

White Paper A Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1) Published: May 2012 Author: Greg Smith, Labtex In this Labtex White Paper: Safety Storage Cabinets Overview What must a Safety Storage Cabinet be able to do A comparison of the fire resistance of cabinet constructions Consequences of the standard in Europe Approval documentation Conclusion the Science of Success www.labtex.co.uk

Safety Storage Cabinets Overview The European Standard BS EN 14470-1 was implemented in April 2004 and has since been published as a national standard in many European countries including the Netherlands, France, Spain, UK, Italy etc. In the UK it is recommended that no more than 50 litres of highly flammable solvent be stored in a room using cabinets referred to in such documents as DSEAR 2002 (Dangerous Substances and Explosive Atmospheres Regulations) and HSG 51 from the Health and Safety Executive (Storage of Flammable Liquids in Containers). These normally refer to single skinned metal cabinets manufactured according to BS 476. However, there is an exception which can be found by visiting the website: http://www.hse.gov.uk/fireandexplosion/storageflammliquids.htm On these web pages it states that subject to a thorough risk assessment, the 50 litre recommendation can be exceeded when using high specification safety cabinets such as those manufactured according to BS EN 14470-1. There are a number of dangers, risks and disadvantages of using an external store or any haphazard storage system When transporting hazardous materials from the centralised storage room to the workplace there is the risk of spillage or other incident. Precious working time is lost when collecting/returning material. Hazardous materials which are used at the work space are not always returned to the central store and hidden quantities of hazardous material develop. In the event of a fire these can contribute to an uncontrollable blaze and the protection of staff and fire fighters can no longer be ensured. If unknown quantities of hazardous materials are stored, or are in use within the laboratory, applicable regulations and laws may be breached. In case of damage, insurance cover may be lost and an employer is liable for property and damage to persons. In the event of an accident, the loss of production cannot be calculated/foreseen, nor the potential long term loss of reputation. Safety, protection and the advantages of a workplace with a fire resistant safety storage cabinet The time spent fetching and carrying from the storage room to the workplace is minimised and all hazardous materials for daily use can be readily available safely and conveniently in the lab. There is increased efficiency as there is no need to move flammables in and out from the central storage room. Type 90 safety cabinets in accordance with EN 14470-1 provide the highest degree of safety for personnel and the environment and give maximum safety to your investment. They guarantee the highest fire protection available today, minimise the potential for explosions and prevent an existing fire from spreading. A type 90 cabinet provides sufficient time for personnel to safely leave the building and for fire fighters to rescue people from the building and to extinguish a fire. Page 2 of 7

What must a Safety Storage Cabinet be able to do? The following points describe the basics and main safety, test and construction requirements. The primary protection for which a safety storage cabinet is intended is to shield stored, hazardous materials from a temperature rise of more than 180K in the event of fire for the defined period of time. Combustion may begin if the temperature rise inside the Safety Storage Cabinet exceeds 180K. From this value up, the majority of chemicals reach their ignition temperature and they explode. Fire is the same in all parts of the world! Whether in London or Lisbon, a fire has the same properties and temperatures. A temperature curve shows that after only 5 minutes a fire has reached a temperature of 576 C. After 30 minutes, 842 C has been reached, and after 90 minutes the flames are at more than 1000 C. The contents of a single skin storage cabinet to BS476 will follow the same temperature curve. A comparison of the fire resistance of cabinet constructions A double-wall steel cabinet provides no more than three minutes of protection before the interior has heated to 180 C. A Type 30 EN Safety Storage Cabinet provides 30 minutes of protection before the interior has heated to 180 C. 10 times more safety in the event of fire compared with a double-wall steel cabinet. Highest safety is achieved with a Type 90 EN Safety Storage Cabinet. These cabinets provide 90 minutes of protection before the interior has heated to 180 C. 30 times more safety in the event of fire and enough time for rescue and fire fighting services to take action. Page 3 of 7

A comparison of the fire resistance of cabinet constructions continued Fire protection In the event of a fire the cabinet must ensure that, over a period of time defined by the manufacturer (but in any event at least 15 minutes), its contents do not present an additional risk that the fire will spread. The cabinet doors must close entirely, starting from any position (closing time max. 20 seconds). Air inlet and outlet openings The cabinets must have openings for air inlet and outlet (for connection of the cabinet to an exhaust system). The ventilation openings must close automatically at a temperature of 70 C. Shelves and drawers must be able to support the loading specified by the manufacturer over the period of the test in the furnace. Design evidence of the load-carrying capacity of shelves and drawers in the event of fire based on EN 1365 (fire resistance tests for self-supporting components). The internal equipment of the cabinet must include a spill containment sump and the spill containment sump must retain its ability to function after the fire resistance test. This is to be checked visually by filling the spill containment sump with water. Fire resistance Each model must be independently verified by tests on a design sample. The fire resistant cabinet is exposed to flames in a suitable furnace. The doors, walls and ceiling of the cabinet being tested must be exposed to the same heating conditions. Cabinets must be tested as free-standing single cabinets. The flame exposure is carried out in accordance with the standard temperature curve of BS EN 1363-1 (5.1.1). The temperature rise is measured inside the cabinet. The cabinet will then be classed as type 15, 30, 60 or 90, according to the time that has elapsed before the temperature rose by 180 K. Page 4 of 7

A comparison of the fire resistance of cabinet constructions continued EN 14470-2. The standard for gas cylinder cabinets Maximum safety in the storage, provision and withdrawal of gas cylinders in indoor areas. Due to the positive pressure and the contents (corrosive, toxic, inflammable, fire accelerating), gas cylinders represent a hazard potential. It is therefore usually recommended to store gas cylinders in outdoor areas. In practice this is often not possible or is associated with very high costs. With the publishing of the new European standard for gas cylinder cabinets, EN 14470-2, an economical and flexible option for the installation of gas cylinders in indoor areas is now available that offers a level of safety comparable to that of outdoor storage. Consequences of the standard in Europe Fire resistance is classified into 4 classes from G15 up to G90 (fire resistance of 15 up to 90 minutes). Each type of cabinet and each cabinet size must to be type tested in a furnace. In case dimensional variation exceeds the tolerance, the cabinet has to be retested again. Tests can only be executed by an authorised material testing institute. Cabinets must be tested in a furnace as free-standing single cabinets. BS EN 14470-2 stipulates declaration of conformity or certificates of conformity be supplied with each cabinet delivery. Approval Documentation Complete approval documentation for each safety storage cabinet includes: 1. A test report of an authorised material testing institute stating/proving the successfully passed fire test. 2. Test certificate by an independent testing organisation and declaration of CE conformity by the manufacturer This ensures compliance with regulations, safety for the user and clear identification of approval documents with the model of safety storage cabinet. Page 5 of 7

asecos - Standard for safety and quality 1. Testing certificates of an authorised material testing institute for each cabinet. Approved fire resistance in accordance with EN 14470-1. 2. Verification for all cabinet models on observing the Equipment and Product Safety Law. Documented in the testing certificates by independent testing organisations. 3. CE approval certificates for each cabinet model. Verification that all relevant European guidelines are observed. 4. Quality Management in accordance to DIN EN ISO 9001. asecos quality from the quotation to the delivery. Conclusion BS EN 14470-1 and BS EN 14470-2 are product specifications giving performance requirements of safety cabinets for internal storage of flammable and other hazardous products. For maximum safety, efficient working practises and to keep one step ahead of legislation these cabinets have no equal. Page 6 of 7

Contacts Labtex is a specialist laboratory and process chemistry equipment solutions provider. A dynamic team of professionals with expertise in research and process development across a wide range of industries and disciplines. You will find that talking to Labtex is a breath of fresh air. No complicated telephone system, just real people ready to react professionally to your enquiry. We pride ourselves on our customer service based on quick response, accurate informed advice and attention to detail. Labtex, Dogley Mills, Penistone Road, Fenay Bridge, Huddersfield, West Yorkshire, United Kingdom HD8 0LE Tel: 01484 600200 Fax: 01484 607390 Email: info@labtex.co.uk Web: www.labtex.co.uk Page 7 of 7