HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR



Similar documents
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Waveguide Access Point WGA631. Product Guide

Duct Humidity Transmitter

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Voltage Regulator SPAU 341 C. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide

Three-phase monitoring relay CM-PFE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SEISMIC VELOCITY TRANSDUCER T1-40

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

T0118 T2118 T3118. Instruction Manual

Bulletin 150 SMC Flex Smart Motor Controller Specifications

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

IPS Magneto-Thermal protection device for electric loads.

MasterINTERFACE 39 Series - Relay interface modules

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Analog signal converters CC-E I/I Current / current isolators

Telephone- and leased line modem for industrial applications TD-36

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Remote Monitoring and REC 501 Control Unit Product Guide

08. SEK IDC CONNECTORS

HERZ-Thermal Actuators

80 Series - Modular timers 16 A. Features

CompactLogix Power Supplies Specifications

OZW30. Central Unit SYNERGYR

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Heating oven with mechanical convection

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Thermistor motor protection

FIREDEX Conventional Fire Panels

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Electronic Control Devices The European Product Catalogue 2007

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

HMI display Installation Guide

STRATO LED Drivers 70W, Single output

3500/62 Process Variable Monitor

Multi-Range Programmable DC Power Supplies 9115 Series

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

DC Electronic Loads 8500 series

Digital input modules

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Rack mounted telephone- and leased line modem for industrial applications

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

2.24. Pump Controller 704. Data Sheet

Electronic overload relay EF19 and EF45

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

... Electronic Softstarter...

Incubator with mechanical convection

MCR1900 Media Converter 19-Slot Chassis

Solid-State Timer H3G

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

1. SAFETY INFORMATION

Power Meter Series 700

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

80 Series - Modular timers 16 A. Features

MasterINTERFACE 39 Series - Relay interface modules

Test equipment for temperature and its reduction

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Physical Specifications (Custom design available.)

Current Monitoring Kit

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Freezers - Ultrafreezers. Platilab & Irilab Series

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

A sophisticated design for a demanding field. prima series

Permissible ambient temperature Operation Storage, transport

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Preset Counter signo 721

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

OLI. Oil level indicator

5000V Graphical Megohmmeter Model 5070

INSTRUCTION MANUAL Oil level indicator with pointer

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Transcription:

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL

Recent approval of new and rigorous European Laws protecting health and the environment require electrical machines to be manufactured with quality and safety standards that are substantially higher than the average standards applied up to now. Given the full and total liability of the manufacturer with respect to third parties however, it is still highly recommended, if not an absolute need, to monitor machine operation and to be able, whenever the need arises, to stop machine operation in order to prevent severe harm to persons and property. 1 2 5 1. Plastic isolating body. 2. Pull-out polarized terminal board. 3. Fastening components. 4. Screws. 5. Front panel made of self-extinguishing plastic. 4 3 Comem Engineering Office has designed and developed an electronic control unit, called MB 103, for use in air-insulated electric transformers - commonly called resin or dry transformers - and which also easily adapts for use in oil transformers. MB 103 units use PT 100 temperature probes for constant monitoring of transformer temperatures in 4 points: 3 on the transformer winding columns + 1 on the machine's magnetic circuit. If the transformer malfunctions, causing its temperature to rise, the MB 103 unit generates an electric alarm signal. If the temperature reaches danger levels the unit generates a 2nd intervention level. This can be connected to a machine stoppage switch that functions independent of alarms. A cooling system control program is also implemented in the unit. BACK PANEL WIRING DIAGRAM SERIAL PORT MB 103 temperature control units are equipped with a serial port for connection to a PC. (A data management program is furnished on request on a floppy disk, together with a small instruction manual.) When testing the transformer real time data can be furnished for all temperature information measured on the various active channels. This can be used to check intervention settings. There is also an automated acquisition function that can generate a graphic history of readings monitored at adjustable time intervals. 3

APPLICATION 4 PT 100 temperature detection probes can be connected to the MB 103 temperature control unit. Software is designed so that any temperature malfunction is acquired, stored and a simple and clear signal is generated so that the machine operator knows how to intervene. Two temperature control alarm levels are provided: one to signal any probe breakdowns and one for control of cooling fan systems. A simple and flexible program is used to set thresholds and determine functions to be enacted and is able to set alarm levels and control for all channels either independently or in groups. It is divided into two sections: a first simplified section that includes the most common values and permits quick setting of parameters that are common for all channels and a second, more complex section that is used to change all programming parameters. A reset function is also installed, bringing all parameters back to default values. The 19 LEDs plus the display permit MB 103 temperature control units to clearly signal and control all information on the temperature status of the equipment being protected. Software characteristics: 2 alarm thresholds signaled by two relay switching contacts Autotest circuit with relay exchange contact and with probe malfunction signaled on the display as well (SSP, OPP). Fan operation setting with programmable hysteresis. This can be connected to all probes with NA relay contact signal. Activation of 1-4 channel operation. Digital linearization of probes. Display test command. Relay test command. Automatic indication of the hottest channel. Storage and retention of the highest temperature reading reached by the probes (MAX). Front panel programming. Recall of the basic pre-set program. Serial port for connection to a PC. GENERAL CHARACTERISTICS Input 4 PT100 (or PTC) temperature sensors Control temperatures minimum -10 C, maximum 200 C Outputs 4 relay outputs with 5A, 250 V A.C. contacts Accuracy 1 C Precision ± 1% on full-scale value + 1 digit Power Universal range 24 220 V D.C. or A.C. ± 10% (Polarity and +12 V D.C. separate input must not be respected) Memory EEPROM with data retention for more than 10 years Working temperature -20 C to +60 C Max. humidity 80%, without condensate VA Absorbed 4 VA Terminal board (IEC 988-1/IEC 998-2-1) Removable and polarized Insulation Double galvanic insulation between supply, microprocessor and temperature probes (2500 V test voltage) Weight 0.5 kg Protection degree IP 54 PROGRAM GRAPH TESTING 4

TESTS MB103 temperature control units have successfully passed both type testing required for achieving the CE brand and all testing required by internal COMEM technical standards: General standards CEI EN 50081-2 (Industrial environmental emissions) Radiant electromagnetic emission test according to EN 55011 standards: passed Harmonic components emission test according to EN 61000-3-2: passed Conducted electromagnetic emission test according to EN 55011 standards: passed General standards CEI EN 50082-2 (Industrial environmental immunity) Electrostatic discharge immunity test according to EN 61000-4-2 standards: passed Radiant electromagnetic field immunity test according to EN 61000-4-3 standards: passed Radiant electromagnetic field immunity test according to ENV 50204 standards: passed Common mode fast transient immunity test (BURST) according to EN 61000-4-4 standards: passed Pulsed transient immunity test (SURGE) according to EN 61000-4-5 standards: passed Radio frequency field-induced disturbance immunity test according to EN 61000-4-6 standards: passed The following routine tests are also performed before shipping each single unit: Visual inspection of the hardware cards Start-up and testing of the supply cards: 24 220 V ±10% D.C. and A.C. at a 5 Hz ±2% frequency Functional testing of display keys and LEDs Temperature test with sample temperature sensors. DELIVERY TERMS MB1034 temperature control units, product code 1MB1030000, are supplied individually in sturdy cardboard packing (dimensions 170x130h x 105 mm). Weight is 0.6 kg. and units are complete with the following accessories: installation and operation instruction manual complete fastening kit removable terminal boards. INSTALLATION INSTRUCTION FOR ASSEMBLY ON CONTROL PANEL DRILLING JIG Make a 90x90 mm square hole on the control panel. Insert the MB 103 temperature control unit in the hole and clamp it using the screw spacers furnished with it. Connect the temperature control unit to the PT100 tempera ture probes, the signal relays and the power supply, pulling out its terminal board for easier access and following the instructions given on the rear panel of the MB104 temperature control unit. No polarity needs to be complied with for Direct Current supply. If possible group instrument components in a zone that is separate from power and relay components. Avoid housing the following components in the same board: high power switches, contactors, relays, etc.; thyristor power units and, in particular, power factor correction units, motors, etc. It is good practice to avoid dust, humidity, corrosive gases and the vicinity to sources of heat. Hole dimensions: 90 x 90 mm. MB 103 TEMPERATURE DETECTOR The temperature probes indicated below are all perfectly compatible with MB 103 temperature control units. Each of these, however, has different structural and commercial characteristics designed to meet the all possible needs of different customers. 5

PT 100 TEMPERATURE SENSORS TIPO / TYPE PT 4I cod. 1PT1000100 TIPO / TYPE PT 6I cod. 1PT1000000 TIPO / TYPE PT 6V cod. 1PT1000200 TIPO / TYPE PT 8V cod. 1PT1000300 PT4I - PT100 platinum temperature sensor designed to DIN 43760, CEI EN 60751 Class. CEI 65-8/IEC 751 standards. Class B precision. N 1 stainless steel dia. 4 x 40 mm. cylindrical bulb. Connection to 3 silver-tinned copper conductors insulated with teflon and twisted. Rubber cover protecting against sharp edges. Standard cable length: 2500 mm. Electric rigidity test: 2500 VCA for 60. Insulating resistance: >100 MΩ at 500 V DC. Maximum operating temperature +180 C. PT6I - PT100 platinum temperature sensor designed to DIN 43760, CEI EN 60751 Class. CEI 65-8/IEC 751 standards. Class B precision. N 1 stainless steel dia. 6 x 65 mm. cylindrical bulb. Cover in heat-shrunk kynar. Connection to 3 silver-tinned copper conductors insulated with teflon. Shielded cable (CU-St) insulated with silicone rubber. Standard cable length: 2500 mm. Electric rigidity test: 3000 VCA for 60. Insulating resistance: >100 MΩ at 500 V DC. Maximum operating temperature +180 C. PT6V - PT100 platinum temperature sensor designed to DIN 43760, CEI EN 60751 Class. CEI 65-8/IEC 751 standards. Class B precision. N 1 flat fibreglass 60 x 10 mm bulb, 3 mm thick. Connection to 3 silver-tinned copper conductors insulated with teflon. Shielded cable (CU-St) insulated with teflon. Standard cable length: 2500 mm. Electric rigidity test: 3000 VCA for 60. Insulating resistance: >100 MΩ at 500 V DC. Maximum operating temperature +180 C. PT8V - PT100 platinum temperature sensor designed to DIN 43760, CEI EN 60751 Class. CEI 65-8/IEC 751 standards. Class B precision. N 1 flat fibreglass 80 x 10 mm bulb, 3 mm thick. Connection to 3 silver-tinned copper conductors insulated with teflon. Shielded cable (CU-St) insulated with teflon. Standard cable length: 2500 mm. Electric rigidity test: 3000 VCA for 60. Insulating resistance: >100 MΩ at 500 V DC. Maximum operating temperature +180 C. 6

EXTENSION CABLE cod. 1PTCDE Extension cable for PT100 probes. Reference standards: CEI 20.22. No. 4 triads of 20 AWG conductors in silver-tinned copper with teflon insulation. Shielded cable (Cu-St) insulated with rubber, dia. 8.8 mm. Cable length: on request. Dielectric rigidity test: 2000 VCA for 60. Operating temperature: minimum -35 C, maximum +90 C. N.B.: reading error with cable > 10 m. Optional calibration with >10 m. cable lengths: extra charge. 7

Due to technical improvement of our products, the information contained in this catalogue may be subjected to change without notice. comem - S.p.A Strada Statale 11, Signolo 22 36054 MONTEBELLO VIC.NO (VI) ITALY Tel. 0444 449 311 Fax 0444 449 352-440 359 http://www.comem.com e-mail: comem@comem.com Company managed and co-ordinated by ABB S.p.A. edizione GB 03/2007 - www.studiograficoedigraf.com