Floating Oscilloscope Measurements And Operator Protection



Similar documents
High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

1.5 GHz Active Probe TAP1500 Datasheet

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes

High-Speed Inter Connect (HSIC) Solution

PCI Express Transmitter PLL Testing A Comparison of Methods. Primer

AN3353 Application note

The Fundamentals of Three-Phase Power Measurements. Application Note

Advanced Power Measurement and Analysis Software DPOPWR Datasheet

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Agilent 87421A/87422A Power Supply

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

Instructions A Amp AC/DC Current Probe

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

TekSmartLab TBX3000A, TSL3000B Datasheet

Agilent 4338B Milliohm Meter

802.11ac Power Measurement and Timing Analysis

AN ISOLATED GATE DRIVE FOR POWER MOSFETs AND IGBTs

Agilent 8762/3/4A,B,C Coaxial Switches

Lab 1: The Digital Oscilloscope

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

MC Low noise quad operational amplifier. Features. Description

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

TL084 TL084A - TL084B

Report on Government Information Requests

AutoRanging Digital MultiMeter

TOPOLOGIES FOR SWITCHED MODE POWER SUPPLIES

Agilent 4339B/4349B High Resistance Meters

AN438 APPLICATION NOTE SAFETY PRECAUTIONS FOR DEVELOPMENT TOOL TRIAC + MICROCONTROLLER

User Manual. CFG253 3 MHz Function Generator

Report on Government Information Requests

TN0023 Technical note

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

TDA W CAR RADIO AUDIO AMPLIFIER

TL074 TL074A - TL074B

EVL185W-LEDTV. 185 W power supply with PFC and standby supply for LED TV based on the L6564, L6599A and Viper27L. Features.

Grounding and Shield Termination. Application Note 51204

User Manual. TDS 200-Series Digital Real-Time Oscilloscope

NI USB-6008/6009 OEM USER GUIDE

Power Supplies in Medical Electronics

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Handheld portable appliance testers

Think SAFETY When Selecting a Handheld Multimeter

Use and Application of Output Limiting Amplifiers (HFA1115, HFA1130, HFA1135)

LOXONE 12 Channel Amplifier

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

AN1826 APPLICATION NOTE TRANSIENT PROTECTION SOLUTIONS: Transil diode versus Varistor

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Agilent P940xA/C Solid State PIN Diode Switches

How To Build A Powerline Box Powerline Generator

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

UA741. General-purpose single operational amplifier. Features. Applications. Description. N DIP8 (plastic package)

10 Multimeter. Users Manual

Why to use isolated amplifiers

Power Analysis of PWM Motor Drives

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Safety Summary. Precision Measurements Start at the Probe Tip Tektronix Probe Selector. Tektronix Resources. Probe Fundamentals

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Lab E1: Introduction to Circuits

HCF4001B QUAD 2-INPUT NOR GATE

TDA W Hi-Fi AUDIO POWER AMPLIFIER

Accuracy counts! SENSORS WITH ANALOG OUTPUT

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

AN820 APPLICATION NOTE INPUT/OUTPUT PROTECTION FOR AUTOMOTIVE COMPUTER

Manual Ranging MultiMeter

Basic oscilloscope operation

The Next Generation in Automated Oscilloscope Test

BXR 300C BXR 300R. Owner, s Manual P/N

Agilent EEsof EDA.

Video Quality Monitors Sentry Verify Datasheet

ESDLIN1524BJ. Transil, transient voltage surge suppressor diode for ESD protection. Features. Description SOD323

Testing Video Transport Streams Using Templates

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

relating to household s disposable income. A Gini Coefficient of zero indicates

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

What Is the Total Public Spending on Education?

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Achat 115MA full-range speaker. user manual

e*scope Remote Control Puts Network-Connected Oscilloscope on Your PC Desktop

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Image Lab Software for the GS-900 Densitometer

Rapid Resolution of Trouble Tickets

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Brochure More information from

HIGH RELIABILITY POWER SUPPLY TESTING

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

How To Use A Cdm250 Digital Multimeter

Report on Government Information Requests

THE WORLD S LEADING CAR DESIGN MAGAZINE

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

Transcription:

Technical Brief Floating Oscilloscope Measurements And Operator Protection Introduction Oscilloscope users often need to make floating measurements where neither point of the measurement is at ground (earth) potential. Signal common may be elevated to hundreds of volts from earth. In addition, many of these measurements require the rejection of high commonmode signals 1 in order to evaluate low-level signals. Unwanted ground currents can also add bothersome hum and ground loops. Too often, users resort to the use of potentially dangerous measurement techniques to overcome these problems. Limitations of Traditional Oscilloscopes Traditional oscilloscope designs cannot effectively handle these problems alone. Let s examine why: Most oscilloscopes have their signal common terminal connected to the protective grounding system, commonly referred to as earth ground or just ground. This is done so that all signals applied to or supplied from the oscilloscope have a common connection point. This is usually the oscilloscope chassis and is held at (or very near to) zero volts by virtue of the third-wire ground in the power cord for AC-powered equipment. It also means that, with few exceptions, all measurements must be made with respect to earth ground. This constrains the typical oscilloscope (at least in a single measurement) from being used to measure potential differences between two points where neither point is at earth ground. Tektronix provides several solutions for floating measurements which are not only safe but also much more accurate than the sometimes used potentially dangerous procedures (see Table 1). These solutions meet the safety engineering principles stated in the sidebar on page 2. They fall into four general categories: Battery-powered oscilloscopes Monolithic isolation amplifiers Differential measurement systems Isolated input oscilloscopes 1 A common-mode signal is defined as a signal which is present at both points in a circuit. Typically referenced to ground, it s identical in amplitude, frequency, and phase. Making a floating measurement between two points requires rejecting the common-mode signal so the difference signal can be displayed. Copyright 1998 Tektronix, Inc. All rights reserved.

WARNING While the subject of this technical note is about Floating Measurements, some definitions of terms and general precautions must be understood before proceeding. Historically, floating measurements have been made by knowingly defeating the built-in safety ground features of oscilloscopes or measurement instruments in various manners. THIS IS AN UNSAFE AND DANGEROUS PRACTICE AND SHOULD NEVER BE DONE! Instead, this technical note describes instruments, accessories, and practices which can make these measurements safely as long as standard safety practices and precautions are observed. WARNING Whenever making measurements on instruments or circuits which are capable of delivering dangerously highvoltage, high-current power, measurement technicians should always treat exposed circuits, bus-bars, etc., as being potentially live, even when circuits have been shut off or disconnected. This is particularly true when connecting or disconnecting probes or test leads. Management And Safety In The Workplace Floating An Oscilloscope: A Definition Floating a ground referenced oscilloscope is the technique of defeating the oscilloscope s protective grounding system disconnecting signal common from earth, either by defeating the grounding system or using an isolation transformer. This allows accessible parts of the instrument such as chassis, cabinet, and connectors to assume the potential of the probe ground lead connection point. This is dangerous, not only from the standpoint of elevated voltages present on the oscilloscope (a shock hazard to the operator), but also due to cumulative stresses on the oscilloscope s power transformer insulation. This stress may not cause immediate failure, but may lead to future dangerous failures (a shock and fire hazard), even after returning the oscilloscope to properly grounded operation! Not only is floating a ground-referenced oscilloscope dangerous, but the measurements are often inaccurate. This results from the total capacitance of the oscilloscope chassis being directly connected to the circuit under test at the point where the common lead is connected. TEKTRONIX RECOMMENDS ONLY THOSE MEASUREMENT TECH- NIQUES THAT COMPLY WITH SAFETY ENGINEERING PRINCIPLES AND ENSURE ACCURATE MEA- SUREMENTS. Safety Engineering Principles Tektronix has adopted many safety principles in the design of their products. Of particular concern to making electrical and electronic measurements are these principles: When the instrument is used properly, accessible parts shall not become hazardously live, even in the event of the single worst-case fault. Electronic devices (those devices employing conduction in a vacuum, gas, or semiconductor) shall not be relied upon for providing operator protection from electric shock. Products should not develop insidious hazards during proper operation (an insidious hazard is a hazard which can develop in a way as to be well established before becoming apparent). The operator shall not need to defeat a protective system to make the measurement. Safety A Shared Responsibility The operator and employer share in the responsibility of meeting these principles through proper operation and measurement techniques. WARNING Never attempt to defeat the protective grounding system of your oscilloscope by using an isolation transformer (left) or disconnecting the ground connector on the power plug (right). Failure to follow safety warnings can result in serious injury or loss of life. page 2

Table 1. Methods of Making Floating Measurements Using Tektronix Instrumentation Meets Safety Dynamic Range/ Ease of Operation Common-Mode Differential Mode Common-Mode Engineering Principle Bandwidth Voltage (Float) Voltage (Signal) Reject Isolation Amplifiers High Medium <850 V RMS <850 V RMS High (A6907 and A6909) Active High Voltage Medium High <2,200 V RMS <4,400 V RMS Medium Differential Probes (P5200 Series) Differential Amplifiers Medium (+) Medium ( ) <353 V RMS <353 V RMS High (P6135A) Battery Powered Low High <30 V RMS <30 V RMS Low Oscilloscopes CAUTION! ONLY ONLY (TDS3000 Series) Isolated Input High High <600 V RMS <1,000 V RMS Low Oscilloscopes (THS700 Series) Isolation Transformers Defeating Grounds WARNING! This Is An Unsafe And Dangerous Practice And Should Never Be Done! WARNING! This Is An Unsafe And Dangerous Practice And Should Never Be Done! Battery-Powered Oscilloscopes The TDS3000 Series (see Figure 1), when operated from AC line power using its standard power cord, exhibits the same limitations as traditional oscilloscopes discussed previously. However, AC power is not always available where you want to make oscilloscope measurements. The TDS3000 Series optional battery pack (TDS3BAT) allows you to operate the oscilloscope without the need for AC power. Observing the following precautions will provide safe operation of the TDS3000 Series oscilloscopes when battery powered. Figure 2 shows the warning that is displayed on the TDS3000 Series screen when in battery operation mode. This warning applies to circuits that have voltages of greater than 30 V RMS (>42 V pk ). If the circuit under test has voltages that exceed 30 V RMS (>42 V pk ), the TDS3000 Series chassis needs to be connected to earth ground using the grounding wire provided with the instrument (Battery Pack) to prevent electrical shock to the operator. If you do not attach the grounding wire, you are not protected against electrical shock if you connect the oscilloscope to a hazardous voltage. WARNING Such electrical shock could result in serious personal injury or loss of life. While in battery operation and following environmental specification limits for the TDS3000 Series, it is safe to float the signal common for making measurements provided you do not connect a signal greater than 30 V RMS (>42 V pk ) from earth ground to either the probe tip or common lead. For measurements where higher voltages {>30 V RMS, >42 V pk ) are present, the instrument s chassis must be connected to earth ground using the supplied grounding wire to prevent electrical shock to the operator. WARNING If there is any doubt whether more than 30 V RMS is present or not, the supplied grounding wire should always be used and floating measurements SHOULD NOT BE ATTEMPTED! Be aware that hazardous voltages may exist in unexpected places due to faulty circuitry in the deviceunder-test. Figure 1. TDS30xx Digital Phosphor Oscilloscope (above). Optional TDS3BAT Battery Pack (right). Figure 2. Warning displayed by TDS3000 Series when operating in battery mode. page 3

It s important to remember that the signal commons for all channels are at the same potential and are NOT independent. Ensure that all probe common leads are connected to the same voltage or common point. Do not connect a grounded device, such as a printer or computer, to the oscilloscope unless the oscilloscope s grounding wire is connected to earth ground! In order to perform differential measurements with independent signal grounds, true differential probes such as the P5205 or P5210 must be used. Monolithic Isolation Amplifiers The Tektronix A6900 Series monolithic isolation amplifiers (see Figure 3) connect between the oscilloscope and the circuit-under-test. The signal is coupled across an electro-optical isolation barrier, providing the necessary isolation. Monolithic voltage isolators provide multiple channels with different common potentials in a convenient portable package. These units are designed to be used next to the measurement instrument where physical separation is not a requirement. Because multiple channels are contained within a single unit, the cost per channel is lower and the actual circuitto-instrument connections are simplified. The A6900 Series monolithic voltage isolators are essential tools for power conversion design. The A6907 and A6909 offer safety, performance, multiple isolated channels (A6907 four channels, A6909 two channels), direct connection to the measurement instrument, and simplified controls in a single instrument package. Total Galvanic isolation is accomplished through the use of electro-optical and optical-electro converters. The isolator chassis is referenced to ground to ensure safety while making floating measurements. The A6900 Series isolators feature a bandwidth of 60 MHz and GPIB control (standard on the A6907; available as Option 10 for the A6909), in a compact package. The CMRR is 105 db (178,000:1) at 60 Hz, 60 db (1,000:1) at 1 MHz and 50 db (316:1) at 10 MHz. The 850 V probes plug directly into the isolators and are specifically designed for safe connection to floating circuits and enhanced CMRR. These microprocessor controlled instruments feature push-button self-calibration of offset and gain for increased accuracy. Coupling and attenuation for each channel can be individually set. The A6907 and A6909 satisfy third party safety standards. Figure 3. A6905 two-channel isolation amplifier (right); A6907 four-channel isolation amplifier (left). Shown with probes. page 4

Differential Measurement System Pseudo-Differential Techniques. The most popular solution to the need for a floating measurement is the A minus B pseudo-differential technique. Most generalpurpose dual-trace oscilloscopes have an ADD Mode where the two channels can be electrically subtracted (invert CH 2), giving a display of the difference signal. Higher voltage probes such as the P5100 (2,500 V, 100X see Figure 4) are used, but they limit minimum sensitivities. This can be a problem when attempting to examine low-level control signals in the presence of high commonmode voltages. Also, the common-mode dynamic range is severely limited (+1 division beyond screen height) and common-mode rejection ratio (CMRR) is low approximately 20 to 1. True Differential Techniques. True differential amplifiers feature complementary inputs (+ and ) and offer high CMRR as high as 10,000 to 1 or higher for many instruments. Since the amplifier s ability to reject the commonmode component depends on the degree to which the two channels remain balanced, its common-mode rejection ratio will decrease with frequency (imbalance due to effects of stray C, etc.) and with the magnitude of the commonmode signal (imbalance due to effects of amplifier overdrive). Use of a differential probe pair such as the P6135A (see Figure 5) is essential to maintain maximum CMRR. Figure 4. P5100 High Voltage Passive Probe. Figure 5. P6135A Differential Passive Voltage Probe pair. page 5

High-Voltage Active Differential Probes. The P5200 Series High Voltage Active Differential Probes are economical, heavy-duty solutions for making safe, accurate floating measurements with any oscilloscope. With true differential amplifiers in the probe heads, the compact P5200 Series are rated for differential voltage measurements up to 4,400 V RMS (5,600 V (DC + pk AC)) depending on the probe chosen. Circuit connections are made by leads terminated by standard 4 mm shrouded banana plugs. The included crocodile clips and insulated plunger style clamps enable safe, easy connections to a wide range of test points from bus bars to IC legs, even when hot. The P5200 (see Figure 6) connects directly to the BNC input of the measurement instrument and is powered by a 9 V wall adapter. The P5200 has a bandwidth of 25 MHz with CMRR of 50 db at 1 MHz. The P5205 (Figure 7) and P5210 (Figure 8) use the Tektronix, Inc. TekProbe interface system found on the TDS3000, TDS 400, TDS 500, TDS 600, and TDS 700 oscilloscope systems. The TekProbe interface provides probe power, readout, and many other features not readily available on common probes. The P5205 has a bandwidth of 100 MHz and a voltage level of 1,300 V RMS. At 4,400 V RMS, the P5210 can measure frequencies up to 50 MHz. Both probes provide a CMRR of 50 db at 1 MHz. The P5200 Series High Voltage Active Differential Probes satisfy today s third party safety standards Figure 6. P5200 High Voltage Active Differential Probe. Figure 7. P5205 High Voltage Active Differential Probe. Figure 8. P5210 High Voltage Active Differential Probe. page 6

Isolated-input Oscilloscopes Isolated-input oscilloscopes such as the Tektronix THS700 Series (THS710A, 60 MHz; THS720A, 100 MHz; THS730A, 200 MHz; THS720P, 100 MHz see Figure 9) are hand-held, battery operated oscilloscopes that feature dual input channels, individually isolated from the oscilloscope s chassis as well as from each other. This allows dual-trace waveform comparisons to be made, with each of the two channels referenced to its own common. The safe operating voltage of these oscilloscopes depends on the probes used. The standard 10X P6117 probe is rated for IEC category II applications up to 300 V RMS tip-to-common, with the common lead floating up to 30 V RMS above earth ground. This range is suitable for most typical measurements on low-voltage electronics circuits. For higher voltage applications, the THS710A, THS720A, THS720P, and THS730A, with the 10X P5102 Probe (see Figure 10), are rated for IEC category II applications up to 1,000 V RMS tip-to-common, with the common lead floating up to 600 V RMS above earth ground. This combination of scope and probe takes full advantage of the THS700 Series IsolatedChannel architecture and allows safe probing of floating signals, providing protection to both the user and the equipment under test. Conclusion Tektronix has reviewed these methods in an effort to increase user awareness regarding the potential dangers inherent in the improper operation of oscilloscopes. Our commitment to Test and Measurement Product Safety has resulted in the isolated input oscilloscope, isolation amplifiers, and differential products described here. If you feel your applications would be more safely and accurately served by these products, please contact your nearest Tektronix representative. Figure 10. P5102 High Voltage Probe for the THS700 Series. Figure 9. THS720P TekScope Isolated Channel oscilloscope. page 7

For further information, contact Tektronix: Worldwide Web: For the most up-to-date product information, visit our web site at www.tektronix.com. ASEAN Countries (65) 356-3900; Australia & New Zealand 61 (2) 9888-0100; Austria, Central Eastern Europe, Greece, Turkey, Malta, & Cyprus +43 2236 8092 0; Belgium +32 (2) 715 89 70; Brazil and South America 55 (11) 3741-8360; Canada 1 (800) 661-5625; Denmark +45 (44) 850 700; Finland +358 (9) 4783 400; France & North Africa +33 1 69 86 81 81; Germany + 49 (221) 94 77 400; Hong Kong (852) 2585-6688; India (91) 80-2275577; Italy +39 (2) 25086 501; Japan (Sony/Tektronix Corporation) 81 (3) 3448-3111; Mexico, Central America, & Caribbean 52 (5) 666-6333; The Netherlands +31 23 56 95555; Norway +47 22 07 07 00; People s Republic of China 86 (10) 6235 1230; Republic of Korea 82 (2) 528-5299; South Africa (27 11) 651-5222; Spain & Portugal +34 91 372 6000; Sweden +46 8 477 65 00; Switzerland +41 (41) 729 36 40; Taiwan 886 (2) 2722-9622; United Kingdom & Eire +44 (0) 1628 403300; USA 1 (800) 426-2200. From other areas, contact: Tektronix, Inc. Export Sales, P.O. Box 500, M/S 50-255, Beaverton, Oregon 97077-0001, USA 1 (503) 627-6877. Copyright 1998, Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 11/98 TD/XBS 51W 10640 1