CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter



Similar documents
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification.

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

A99B Series Temperature Sensors

System 350 A350E Electronic Cooling Control

P66 Series Electronic Fan Speed Controls

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Duct Humidity Transmitter

About the HotWire Slot Standalone Shelf

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

HVAC Processes. Lecture 7

T600xxx-4 and T600xxx-4+PIR Series Thermostat Controllers

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Triple Expansion Chassis

HE-6800 Series Humidity Transmitters with Temperature Sensor

T5000 T000 LCD Digital Fan Coil Thermostat

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

MCR1900 Media Converter 19-Slot Chassis

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

WARNING CANADIAN D.O.C. WARNING

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Power Over Ethernet Adapters POE101

HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide

Contents. Document information

System 350 A350R Electronic Temperature Reset Control (with Relay)

PIEZOMETER AIRFLOW MEASURING RING

FX07 Field Controller

T7560A,B,C Digital Wall Module

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Electronic Control Devices The European Product Catalogue 2007

aseries A13B Mini Bullet Camera User Manual

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

BroadBand PowerShield. User Manual

Broadband Telecommunications Drop Amplifier

How To Use A Ds340 (Dsp)

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

RRV934. Multi-controller. Synco living

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

Digital inductive conductivity transmitter

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued April 17, 2015

P70, P72, and P170 Series Controls for Dual Pressure Applications

Product Documentation on the World Wide Web

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE

Ultima X Series Gas Monitors

T7079A,B Solid State Remote Temperature Controllers

USB Mini Print Server PS121. Installation Guide

Perle Protocol Transparent Media Converter Modules

PRODUCT PROFILE FEATURES

iosafe Solo External Hard Drive

E-PDD Duct Smoke Detector Installation Sheet

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

FIBER OPTIC A/B/C SWITCH (Latching)

AXIS T81B22 DC 30W Midspan

Nevco, Inc. Installation Manual

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide

RAEGuard EC FGM-13XX

Network Control Engine Product Bulletin

Operating Instructions. UL325 Compliant Non-monitored

Simon XTi Installation Guide

Digital Library Assistant Model 701

Wireless Indoor/ Outdoor Thermometer

User guide. Miracast Wireless Display IM10

Technical Support. Support Information

Overview of Standards for CO Detection Products

Perle Fast Fiber to Fiber. Media Converters

Power Supply Guide Version 1.0 for D-Show

Model PS-4001 Power Supply User Instructions

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

HIH-4000 Series Humidity Sensors

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Y7230A CO 2 Alarm System

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Lockout Specification BW Clip Maintenance-free single gas detector

Dear Customer! Thank you for choosing our product.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Application Requirement

Zebra RW 420 Mobile Battery Eliminator Kits

EGSTON Standard E2xFxWx 12W

, User s Manual

Electronic Control Devices The European Product Catalogue 2007

Radiant Temperature Sensor TY7321

Powerline PL500 Series Adapter

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

GREISINGER electronic GmbH

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

HMI display Installation Guide

Transcription:

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter Product Bulletin CD-Pxx-00-1 Code No. LIT-216525 Issued December 6, 2010 Supersedes September 12, 2008 Johnson Controls offers a complete line of Carbon Dioxide (CO 2 ) transmitters for measuring and transmitting CO 2 levels, ranging from 0 to 2,000 parts per million (ppm), within Heating, Ventilating, and Air Conditioning (HVAC) applications. These compact, duct mounted devices offer a choice of 0 to 10 V or 0 to 20 ma output signals and feature an optional relay output with or without a digital display. Johnson Controls CO 2 transmitters are easy to install and to operate. The silicon-based CARBOCAP sensor delivers high accuracy and long-term measurement stability (±100 ppm) over a five-year period without calibration. The diffusion-aspirated, single-beam, dual-wavelength sensor structure is remarkably simple. It consists of an infrared (IR) source, a sample cell, an IR detector, and a tunable interference filter that enables measurements at two wavelengths. Reference measurements made using a tunable interference filter eliminate the typical weakness of dual-beam sensors and permits shifting the optical pass band electronically. This innovative design provides precise reference readings that eliminate the typically broad deviation expected from a traditional CO 2 sensor. Table 1: Features and Benefits Features Energy Savings from DCV Strategies CARBOCAP Single-Beam, Dual-Wavelength Design CARBOCAP Silicon, Micro-machined Construction Calibration Reliability Adjustable Duct Probe Depth Extended (Optional) Features Refer to the QuickLIT Web site for the most up-to-date version of this document. Benefits Figure 1: Duct Mount CO 2 Transmitter with Conduit Adaptor and Mounting Flange Offer potential for 10 to 70% energy savings. Provides superior performance compared to other technologies. Provides reliable CO 2 measurement in duct environments. Offers 5 years of reliable calibration. Permits optimal placement of sensing tip in a duct. Offer relay output for fan control. 1

Product Overview This transmitter uses a completely new CO 2 sensing technology. The silicon based CARBOCAP sensor provides stability and reliability. The CARBOCAP sensor operates in accordance with the single-beam, dual-wavelength method. This patented sensor has unique reference measurement capabilities, offering excellent stability over both time and temperature. The monolithic Fabry-Perot Interferometer (FPI) chip utilizes the optical, mechanical, and electronic properties of silicon at the same time. The transmitter is factory set to measure CO 2 levels up to 2,000 (ppm). It requires a Class 2, 24 VDC/VAC power source and generates an output signal proportional to the CO 2 level detected. The duct mounted CO 2 transmitter series offers: standard CO 2 transmitter transmitter with relay output IMPORTANT: The CD-W00-00-1CO 2 Transmitter is intended to provide an input to equipment under normal operating conditions. Where failure or malfunction of the transmitter could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the transmitter. These compact, devices are designed to work: in standalone mode in support of Demand Control Ventilation (DCV) with fresh air and Indoor Air Quality (IAQ) systems as part of any integrated Building Automation System (BAS) with rooftop air handling Economizer controls systems connected to Metasys system or the AD-DME series Calibration Johnson Controls CO 2 transmitters are calibrated using certified gases for the following: output signal (0 to 10 V) proportional to CO 2 concentration (0 to 2,000 ppm) altitude range of 0 to 1,969 ft (0 to 600m) above sea level without compensation relay output trigger point set for 1,000 ppm (in models featuring the optional relay output) CARBOCAP Technology Johnson Controls is licensed to integrate the new, silicon based CARBOCAP CO 2 sensor into HVAC or Building Automation Systems. This sensor has several advantages: high accuracy, excellent stability, negligible temperature dependence, and ease of installation. The structure of the diffusion aspirated, single-beam dual-wavelength sensor is remarkably simple. It consists of an Infrared (IR) source, a sample cell, a tunable interference filter, and an IR detector. The tunable interference filter enables measurements at two wavelengths. As a result, references are measured accurately, without the typically broad tolerances inherent in dual-beam sensors. Dust, water vapor, and most chemicals do not affect the measurement accuracy of the sensor. No special software compensation patches are required. Packaging Innovation Johnson Controls offers the industry's first duct mount package that is Underwriters Laboratories, Inc. (UL) Listed and requires no separate hardware. This product includes a strain relief/conduit adapter for connecting to standard 1/2 in. fittings. The CARBOCAP sensor is not affected by typical airflow rates encountered in ducts or rooftop air handlers. The compact design of the device requires only a small hole in the ventilation duct, which eliminates the problems associated with leaking gaskets. The enclosure reduces material and labor costs by offering 2

Energy Efficiency Using the CO 2 transmitter duct probe results in considerable savings in installation, operation, and maintenance costs with no recalibration expenses. Johnson Controls CO 2 transmitters, when used with BAS/Economizer controllers (featuring DCV strategies), can generate energy savings ranging up to: 20 to 40% in office buildings 20 to 60% in restaurants/light retail facilities 10 to 70% in educational/business settings Dimensions See Figure 2 and Figure 3 for CO 2 transmitter and mounting flange dimensions. 3.13 (79.38) 1.50 38.10) 2.52 (64.00) 3.14 to 5.51 (80.00 to 140.00) Figure 2: Transmitter Dimensions, in. (mm) 1.65 (42) 0.87 (22) 0.59 (15.00) FIG:trns_dim Optional Feature Relay Module For applications where On/Off ventilation or fan control is required to provide fresh air, order the CD PR0 00 0 transmitter. This model includes a relay output module that plugs into the main Printed Circuit Board (PCB) offering a 30V, 0.5A Class 2 output with configurable On and Off trip points. Default On is 1,000 ppm, and default Off is 950 ppm. Note: To redefine the relay On and Off trip points to suit the application, use the ACC CD S Relay Setpoint Software. Repair Information If the CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter fails to operate within its specifications, replace the unit. For a replacement CO 2 transmitter, contact the nearest Johnson Controls representative. Altitude Compensation These devices are intended for an altitude range of 0 to 1,969 ft (0 to 600m) without compensation. To compensate for higher altitudes, refer to the installation instructions for this device. Ordering Information Contact the nearest Johnson Controls representative to order a CO 2 transmitter, and specify the desired product code number from Table 1. See Table 3 for replacement parts and Table 4 for accessories available for the duct mount CO 2 transmitter. 1.65 (42) Figure 3: Mounting Flange Dimensions, in. (mm) FIG:mnt_dim Table 2: CO 2 Transmitters CD-P00-00-0 CD-PR0-00-0 Duct Mount CO 2 Transmitter Duct Mount CO 2 Transmitter Table 3: Replacement Parts for Duct Mount CO 2 Transmitters ACC-CD-R ACC-CD-CFK1 Relay Output Module for use in CD-P00-00-0 or CD-PR0-00-0 Conduit Adaptor Kit 3

Table 4: Accessories for Duct Mount CO 2 Transmitters ACC-CD-S Relay Setpoint Software Kit; includes software and interface cable to reset the On and Off relay setpoints for CD-PR0-00-0 Y6531-0 Multiple Primary Transformer, 40 VA, 12-/208/230V Primary 24V Class 2 Secondary with Screw Terminals, Foot Mounting or 4 x 4 in. (101.6 x 101.6 mm) Plate Technical Specifications CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter Measuring Range 0 to 2,000 ppm CO 2 Accuracy at 77 F (25 C) < ±[30 ppm CO 2 + 2.0% of reading] (includes manufacturing deviation and drift). All accuracy specifications reflect testing the transmitters using high-grade, certified gases. Transmitters are intended for an altitude range of 0 to 1,969 ft (0 to 600 m) above sea level without compensation Non-Linearity < 0.5% of Full Scale Temperature of Dependence of < 0.56% of Full Scale/F (<0.1% of Full Scale/C ) Output Long-Term Stability < ±5.0% of Full Scale/5 Years Response Time (0 to 63%) 1 Minute Operating Temperature Range 23 to 113 F (-5 to 45 C) Storage Temperature Range -4 to 158 F (-20 to 70 C) Humidity Range 0 to 85% non-condensing Transmitter Output Signal CO 2 Jumper Selectable: 0 to 20 ma or 4 to 20 ma or 0 to 10 VDC (Default) Maximum Output Current: 25 ma; Maximum Output Voltage: 12.5 V Maximum 30 V, 0.5 A, Class 2 Recommended External Load Current Output: Maximum 500 ohms Load Resistance Voltage Output: Minimum 1,000 ohms Load Resistance Power Supply Range 20 to 30 VAC (18 to 30 VDC), Class 2 Power Consumption < 2.5 W Average, 4.1 VA Warm-up Time < 5 minutes Airflow Range 0 to 7,500 ft/minute (0 to 2,286 m/minute) Duct Probe Material Duct Probe Meets Plenum Rating Requirements of UL 1995, Heating and Cooling Equipment Housing Material ABS Plastic Dimensions (H x W x D) 3-5/32 x 3-3/16 x 8 in. (80 x 81 x 204 mm) Shipping Weight 0.3 lb (140 g) Compliance United States UL Listed, CCN XAPX Canada UL, LIsted XAPX7 Europe CE Mark Johnson Controls, Inc., declares that the CD-Pxx-00-0 Duct Mount CO 2 Transmitters are in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC. The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 4

United States Emissions Compliance This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. Canadian Emissions Compliance This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2010 Johnson Controls, Inc. 5 Published in U.S.A. www.johnsoncontrols.com