General Specifications



Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

CompactLogix Power Supplies Specifications

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

3500/93 System Display

Voltage Regulator SPAU 341 C. Product Guide

General Specifications

3500/22M Transient Data Interface

Temperature & Humidity SMS Alert Controller

NC-12 Modbus Application

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

1756 ControlLogix Chassis Specifications

Electro-pneumatic control valves

General Specifications

10/100/1000 Base-T to Gigabit Fiber Media Converter

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Digital input modules

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

DeltaV SISnet Repeater

Mitel DECT Base Stations

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Modular I/O System Analog and Digital Interface Modules

PCS0100en Persy Control Services B.V. Netherlands

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Foxboro Evo Process Automation System

3500/62 Process Variable Monitor

Accessories SUNNY REMOTE CONTROL

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

HCR3.2/.. Chipcard reader HOTEL SOLUTION

OZW30. Central Unit SYNERGYR

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

StructureScan HD Module. Installation Guide ENGLISH

DC Electronic Loads 8500 series

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

In-Sight Hardware specifications

LT-82 Stationary IR Transmitter

Prisma IP 10 GbE VOD Line Card

General Specifications

Application Server V240 Platform

General Specifications

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

Quick Connect. quick - simple - efficient.

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

Waveguide Access Point WGA631. Product Guide

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

SYSTEM DESCRIPTION Termination Boards

T Zone Weekly Timer


Technical Information

ABB RTU560A Series CMU & Modules

Scout 1U Rackmount Computer

USER MANUAL V5.0 ST100

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

G-TAP A Series // Data Sheet

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Setting Up and Testing the MAX Hardware

TrueAlarm Fire Alarm Systems

DCS Data and communication server

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

HARTING mcon 1000 Introduction and features

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

GSM HOME SECURITY SYSTEM

MRC High Resolution. MR-compatible digital HD video camera. User manual

Frequency Converter Fv

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Frequency selective monitoring and logging of environmental electromagnetic fields

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Multi-Range Programmable DC Power Supplies 9115 Series

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

FIREDEX Conventional Fire Panels

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

IOVU-571N ARM-based Panel PC

S-series Mass Connection Solutions

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

Disturbance Recoder SPCR 8C27. Product Guide

Fujitsu PRIMERGY BX600 S3 Blade Server

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

SMART Board interactive flat panel with appliance Model 8055ie-SMP

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

3500/25 Enhanced Keyphasor*Module

PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February Specifications subject to change without notice.

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Transcription:

General Specifications GS 33K50E20-50E Models AFV40S, AFV40D Field Control Unit Duplexed Field Control Unit (for Vnet/IP and FIO, with Cabinet) GENERAL This GS covers the hardware specifications of the Field Control Unit (FCU) which is the core of the control function of the Field Control Station (FCS). HARDWARE SPECIFICATIONS For the installation specifications and environmental conditions that are common to the systems, refer to Integrated Production Control System CENTUM VP System Overview (Vnet/IP Edition) (GS 33K01A10-50E). Processor VR5532 (350 MHz) Main Memory Capacity 128 MB Memory Protection During Power Failure Battery Battery Backup for Main Memory: Max. 72 hours Battery Recharge Time: Min. 48 hours FCU Status Contact Output 3 terminals (NC, NO and C) Contact Points open or close during FCU failure Contact Rating: Rated voltage: 250 V AC, max. 30 V DC Rated current: Max. 2 A Rated power supply: Max. 125 VA Communication Interface Vnet/IP Interface: Dual-redundant ESB Bus Interface: Dual-redundant or single (Always dual-redundant for AFV40D) For more details, refer to Integrated Production Control System CENTUM VP System Overview (Vnet/IP Edition) (GS 33K01A10-50E). House Keeping (HK) Function A House Keeping Unit (HKU) is standard hardware component provided with the type of FCU. With the HK function is able to monitor the environmental conditions of the connected cabinets via HK bus and/or optical ESB bus, and display HKU s operating status on HIS. System alarms can also be displayed. Cable: HK Bus cable (AKBHKU) Units that can be connected HKU of AFV40 : HKU of ACUKT1, ACUKT2, ACB51, or XL- Cabinet. Maximum number of connectable cabinets: 9/FCU (AFV40 ) Total maximum length of cable: 100 m (*1) Equipment in Cabinet FCU: 1 Power Distribution Board with Built-in HKU: 1 (Dual or single power supply) Power Supply Bus Unit, Vertical Type (AEPV7D): 2 (1 at front and 1 at rear) Node Fan Unit (ANFAN) (*1): Max. 4 (2 at front and 2 at rear) Door Fan Unit (AIP601): 4 (2 for front doors and 2 for rear doors) *1: Specify the option code. Module Configuration in FCU Power Supply Module (PW481, PW482, or PW484): Two modules in case of a dual-redundant configuration. Processor Module (CP461): Two modules in case of a dual-redundant configuration. ESB Bus Coupler Module (EC401 or EC402): Two modules in case of a dual-redundant configuration. I/O Modules (*1): Max. 6 *1: Non-standard components. *1: The each section connected in a daisy chain with HK bus. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 GS 33K50E20-50E Copyright Aug. 2011(YK) 5th Edition Jan. 17, 2014(YK)

Installation Restrictions To install Optical ESB Bus Node Units (ANB11 ) or ESB Bus Node Units (ANB10 ) in a remote location, use the Optical ESB Bus Repeater Master Module (ANT401 or ANT411) to connect them with an optical fiber cable. To install Optical ESB Bus Repeater Master Modules in the FCU, install a pair of modules in slots 1 to 6 from right to left according to the number of branches. In a single configuration, install the individual modules in slots 1, 3, and 5 in order from right to left. For details, see Optical ESB Bus Repeater Module (GS 33K50F51-50E/GS 33K50F52-50E). For the restrictions and notes for installing I/O modules, see FIO System Overview (for Vnet/IP) (GS 33K50F10-50E). No. of Node Units Connectable with FCU Max. 13/FCU The total number of ESB Bus Node Units (ANB10 ) and Optical ESB Bus Node Units (ANB11 ) that can be connected to FCU are 13 or less. ER Bus Node Unit (ANR10 ) cannot be connected. Control Function for Field Control Station (LFS1700) allows up to 3, and can be extended as follow by adding Node Expansion Package (LFS1750). LFS1750-V1: Max. 9/FCU LFS1750-V2: Max. 13/FCU To connect a node unit to the FCU, a Node Unit Expansion License (option code: /NDEL) is required for the node unit. No. of Units installable in Cabinet FCU: Max. 1/cabinet (front) Unit (*1): Max. 11/cabinet (5 at front and 6 at rear) *1: ESB Bus Node Unit (ANB10 ), and Unit for Optical ESB Bus Repeater Module (ANT10U) No. of Node Fan Units installable in Cabinet The required number of Node Fan Units (ANFAN) varies depending on the total number of units (*1) that are installed in the cabinet. The required number of Node Fan Units needs to be specified as an option. The total No. of units (*1) The required No. of Node Fan Units 0-4 1 5-9 2 10 3 11 4 *1: ESB Bus Node Unit (ANB10 ), and Unit for Optical ESB Bus Repeater Module (ANT10U) Power Consumption 100-120 V AC: 2500 VA (at max. node installation) 220-240 V AC: 2860 VA (at max. node installation) 24 V DC: 71A (at max. node installation) Weight Approx. 240kg (excluding node) Approx. 360 kg (at max. node installation) Connection Power Supply: M6 screw terminal connection (dual power system possible) Grounding: M8 screw terminal connection FCU Status Contact Output: M4 screw terminal connection Paint Color Main body: Frosty white (Munsell No. 2.5 Y 8.4/1.2) Channel base: Spring black (Munsell No. 3.3PB2.5/0.5) Channel Base Option Specification Channel base with hole for cable: (Option Code:/CH) A hole for cables, 300 (length) by 40(width) mm is opened at the rear of the channel base (with filler plate at time of delivery). IP Protection Rating IP20 Regulatory Compliance For the detailed information on following standards, see Integrated Production Control System CENTUM VP System Overview (Vnet/IP Edition) (GS 33K01A10-50E). Safety Standards [CSA] (for 100-120 V AC power supply) [CE Marking] (for 100-120 V AC, 220-240 V AC, and 24 V DC power supply) EMC Conformity Standards [CE Marking] (for 100-120 V AC, 220-240 V AC, and 24 V DC power supply) [C-Tick Marking] (for 220-240 V AC and 24 V DC power supply) [KC Marking] (for 100-120 V AC, 220-240 V AC, and 24 V DC power supply) 2 Power Supply Voltage: 100-120 V AC, Frequency: 50/60 Hz Voltage: 220-240 V AC, Frequency: 50/60 Hz Voltage: 24 V DC Specify with the Suffix Code. GS 33K50E20-50E Jan. 17, 2014-00

3 EXTERNAL DIMENSIONS (650) 25 600 25 800 Unit: mm (60) 2105 Front view Side view HARDWARE CONFIGURATION When installing ESB Bus Node Units in the cabinet using ESB Coupler Module (EC401), up to 9/FCU (AFV40 ) can be installed When installing ESB Bus Node Units in the cabinet using the ESB Coupler Module (EC402), up to 11/FCU (AFV40 ) can be installed. Up to 5 node units can be installed at the front of the cabinet, and up to 6 node units at the rear. F02E.ai Front Rear Example of node installation position and configuration in cabinet (when using EC402) F03E.ai GS 33K50E20-50E Aug. 19, 2011-00

4 HK BUS CONNECTION EXAMPLE Optical ESB Bus (Max. 50 km) ESB Bus AFV40 ACB51 ETBC ACB51 ETBC HK Bus Transmission Distance: Max. 100 m HK Bus Transmission Distance: Max. 100 m F04E.ai GS 33K50E20-50E Aug. 19, 2011-00

5 Models and Suffix Codes Field Control Unit (for Vnet/IP and FIO, with Cabinet) Description Model AFV40S Field Control Unit (for Vnet/IP and FIO, with Cabinet) -S Standard type 3 Dual-redundant Vnet/IP, single power supply (*1) 4 Dual-redundant Vnet/IP, dual-redundant power supply 1 Single ESB Bus, EC401 1 2 Dual-redundant ESB Bus, EC401 2 (*1) 3 Single ESB Bus, EC402 1 Suffix Codes 4 Dual-redundant ESB Bus, EC402 2 (*1) 1 Always 1 1 100-120 V AC Power Supply 2 220-240 V AC Power Supply Option Codes 4 24 V DC Power Supply 0 Basic type 1 LFS1700 Control function for field control station (for AFV30 /AFV40, Vnet/IP and FIO) <for CP461> / -S1C Node unit for Single ESB Bus Single power supply (*2) [Model: ANB10S-3 5/NDEL] / -S2C Node unit for Single ESB Bus Dual-redundant power supply (*2) [Model: ANB10S-4 5/NDEL] / -D2C Node unit for Dual-redundant ESB Bus Dual-redundant power supply (*2) [Model: ANB10D-4 5/NDEL] / -T1A Unit for Optical ESB Bus Repeater Module Single power supply (*2) [Model: ANT100-3 5/NDEL] / -T2A Unit for Optical ESB Bus Repeater Module Dual-redundant power supply (*2) [Model: ANT10U-4 5/NDEL] / -FAN Node fan unit (*3) [Model: ANFAN- 0] /CH Channel base with cable hole (*4) /CE With CE Marking, C-Tick Marking and KC Marking (*4) /ATDOC Explosion Protection Manual (*5) Note: Node Units must be installed in the cabinet in the following order: first ANB10 and then ANT10U. Note: Connector Unit for ESB Bus and ESB Bus Cable (YCB301) in the cabinet are all already connected. However, ESB Bus Cable between ANB10 and ANT10U is not connected. Note: To perform HK bus communication between cabinets, HKUs of the cabinets must be connected with the HK Bus Cable (AKBHKU). (To connect cabinets with the optical ESB bus, the HK bus cable is not required.) *1: Suffix codes -S32 and -S34 cannot be specified. *2: Specify the number of units to be installed (1 to 9, A, or B) in as needed. (If the number of units to be installed is 10, specify /A-, and if 11, specify /B-. ) The maximum number of units (ANB10 /ANT10U) that can be installed in the cabinet is 11. However, to install ANB10 and ANB11, a Node Expansion Package is required separately depending on the total number of units to be connected to the FCU. When installing different types of unit in the cabinet, installation is only possible in a configuration that meets the following conditions. -S31 or -S33 : / -S1C and / -T1A -S41 or -S43 : / -S2C -S42 or -S44 : / -D2C and / -T2A *3: Node Fan Units (ANFAN) must be specified as follows according to the total number of units (ANB10 /ANT10U ) to be installed in the cabinet. Number of units is 0 to 4: /1-FAN Number of units is 5 to 9: /2-FAN Number of units is 10: /3-FAN Number of units is 11: /4-FAN *4: If /CH is specified, CE Marking, C-Tick Marking and KC Marking cannot be specified. *5: Select the option code /ATDOC to follow the ATEX Directive for use in potentially explosive atmospheres. GS 33K50E20-50E Jan. 17, 2014-00

6 Duplexed Field Control Unit (for Vnet/IP and FIO, with Cabinet) Description Model AFV40D Duplexed Field Control Unit (for Vnet/IP and FIO, with Cabinet) -S Standard type 4 Dual-redundant Vnet/IP, dual-redundant power supply 2 Dual-redundant ECB Bus, EC401 2 4 Dual-redundant ESB Bus, EC402 2 1 Single power supply Suffix Codes 2 Dual power supply 1 100-120 V AC Power Supply 2 220-240 V AC Power Supply 4 24 V DC Power Supply 0 Basic type 1 LFS1700 Control function for field control station (for AFV30 /AFV40, Vnet/IP and FIO) <for CP461> / -D2C Node unit for dual-redundant ESB Bus Dual-redundant power supply (*1) [Model: ANB10D-4 5/NDEL] / -T2A Unit for Optical ESB Bus Repeater Module Dual-redundant power supply (*1) [Model: ANT10U-4 5/NDEL] Option Codes / -FAN Node FAN unit (*2) [Model: ANFAN- 0] /CH Channel base with hole for cable (*3) /CE With CE Marking, C-Tick Marking and KC Marking (*3) /ATDOC Explosion Protection Manual (*4) Note: Node Units must be installed in the cabinet in the following order: first ANB10 and then ANT10U. Note: Connector Unit for ESB Bus and ESB Bus Cable (YCB301) in the cabinet are all already connected. However, ESB Bus Cable between ANB10 and ANT10U is not connected. Note: To perform HK bus communication between cabinets, HKUs of the cabinets must be connected with the HK Bus Cable (AKBHKU). (To connect cabinets with the optical ESB bus, the HK bus cable is not required.) *1: Specify the number of units (1 to 9, A, or B) to be installed in as needed. (If the number of units to be installed is 10, specify /A-, and if 11, specify /B-. ) The maximum number of units (ANB10 /ANT10U ) that can be installed in the cabinet is 11. To install ANB10 and ANB11, a Node Expansion Package is required separately depending on the total number of units to be connected to the FCU. *2: Node Fan Units (ANFAN) must be specified as follows according to the total number of ANB10 and ANT10U units that are installed in the cabinet. Number of units is 0 to 4: /1-FAN Number of units is 5 to 9: /2-FAN Number of units is 10: /3-FAN Number of units is 11: /4-FAN *3: If /CH is specified, CE Marking, C-Tick Marking and KC Marking cannot be specified. *4: Select the option code /ATDOC to follow the ATEX Directive for use in potentially explosive atmospheres. Side Panel for Cabinet Model ACB2P Side Panels for Cabinet Description Note: Two panels are necessary when mounting on both sides of the cabiet. SOFTWARE REQUIREMENT For AFV40S and AFV40D, the Control Function for Field Control Station (LFS1700) is required. Specify this control function with the suffix code. The number of the connectable node units and the application capacity can be expanded if the Node Expansion Package (LFS1750) is purchased. For the specifications of LFS1700 and LFS1750, refer to GS 33K15C10-50E. REQUIREMENTS FOR USING SEM (SEQUENCE OF EVENTS MANAGER) For using SEM, the hardware requires some conditions. For details, refer to SEM Sequence of Events Manager (for Vnet/IP and FIO) (GS 33K30D10-50E). GS 33K50E20-50E Jan. 17, 2014-00

7 STANDARD ACCESSORIES The FCU is delivered with the following standard accessories. Part Name Part No. Description Quantity Remarks Filter T9070CB 2 for Door RELATED PRODUCTS Model AKT211 Connection Kit for Cabinet ORDERING INFORMATION Specify model and suffix codes. TRADEMARKS CENTUM and Vnet/IP are registered trademarks of Yokogawa Electric Corporation. Other product and company names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice. GS 33K50E20-50E Aug. 19, 2011-00