Introduction to Implosive Connectors



Similar documents
Implosive Connectors. for overhead transmission lines

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

COIL PAC. Subec AB, Sprängarvägen 16, Saltsjö-Boo, Sweden, Tel.: , Fax: , info@subec.se

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

EH-20 20m antenna. By VE3RGW

Reliable Metal Bending

ROOM TEMPERATURE SUSTAINED LOAD TEST ON 1572 KCMIL BITTERN ACCC/TW CONDUCTOR FOR COMPOSITE TECHNOLOGY CORPORATION

5.2. Overview. The better method to install solderless compression connectors on power cable

ANTENNA PARTS CATALOG

TARIFF CODE and updates standard

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

71

Thermostatic valve Type AVTA

Connect. Cable preparation and cutting tools

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Installation instruction CASAFLEX - Connecting piece DN 100

PX Series. from 18 to 29 m

Plug and Abandonment Forum

YOUR LOCAL SOURCE IN A GLOBAL WORLD YOUR SUPPLIER OF METAL COMPONENTS

Schedule-4(A3) Page 1 of 5. Specification No.: JPL/KWTL/A3 (Package-A3) To: Bidder's Name & Address

Front axle components, overview

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

Assembly Instruction CAI- Connector with universal Endbell

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

Ergonomical Polyurethane recoil hose

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

air water oil antifreeze grease diesel fuel kerosene oxygen-acetylene lpg-methane electricity Hose & cable reel

Machine needle shut-off nozzle type-a

Portable Hardness Tester

Substation Accessories

2700 DUST CONTROL MACHINE:

Unit 6: EXTRUSION. Difficult to form metals like stainless steels, nickel based alloys and high temperature metals can also be extruded.

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Fault location on power cables. Fault location on power cables

5-Other arc welding WELDING TOOLS AND ACCESSORIES

Nordson Automatic Spray Gun Support Kits

Activity 2.3b Engineering Problem Solving Answer Key

Specific volume and absorption properties

Soldering Techniques N I A G A R A C O L L E G E T E C H N O L O G Y D E P T.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

HARTING Ethernet Cabling 4-poles Overview

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

producer of zinc, aluminium, magnesium die casting and plastic moulding

FAG Hydraulic nuts. Technical Product Information

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

18. SKATES, PLATFORM HAND TRUCKS, LIFTING TABLES AND HAND TROLLEYS

Wire, Cable, and Battery Accessories Product Catalog

Linear Luminaire with LED Series EXLUX 6402/2

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Welding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)

multi-axis system ROBOTRAX cable 3D cable carrier system carrier

ORLANDO srl. M P R OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

INDIAN STANDARDS (BIS) ON WELDING

Machine needle shut-off nozzle type HP

UGVCL/SP/591/11KV HT AB CABLE

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Erich Lacher Präzisionsteile

Trunk Cables.

MESSENGERS FOR AERIAL CABLE

Hand chain 6,0m 1000kg

Cables and Accessories Selection Guide

Flash Butt Welding Machines

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

Session 14 Cable Support Systems

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

This kit may void factory warranty please check with manufacturer.

DESIGN STANDARDS SECTION

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

758 Heavy-duty Ratchet Guy Wire Cutter

KLEIN UTILITY TOOLS & MISC.

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

M-9000-ZX3 JRSC Focus Big Boost Upgrade Kit INSTALLATION INSTRUCTIONS

SECTION SIGNAL WIRE AND CABLE

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

Network Standard Advice No. 1420C 9/6/2011

Fundamentals of Extrusion

Fitting Instructions Garador, Westland & Catnic Garage Door Spring Box Roller Wheels & Wall Bracket & Link Arm

Terminal Boxes Series 8146

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

2100 AD Mirror Elevator Ball Nut Replacement Procedure

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

WORLDWIDE AUSTRIAN CABLE SYSTEMS

Flexit Central Vacuum Cleaner

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

Transcription:

Introduction to Implosive Connectors 9 June 2011 1

VP metall AS VP metall is situated in Raufoss Industrial Park, where you find the leading know-how in metallurgy and machining technology in Norway. 2

VP metall AS Activities: Production of Implosive Connectors Machining of: Aluminium Copper Brass Steel Hot forging 500 ton press Designing and construction of tools 3

VP metall AS Activities cont.: Punching and bending Presses up to 100 tons Designing and construction of tools CNC-machining Unisign, 12000 r/min, 52 tools, vertical mandrel, 4 axes MAZAK H 400, 10000 r/min, 30 tools, horizontal mandrel Mazak QT 250, drill/mill 12 tools, 4 axes Machining and assembly of automotive parts for SAAB 4

History implosive fittings 1965-1968 Development. Cooperation between RA NVE, FFI and SINTEF 1968 Plastic explosives on steel First installation, NVE, 2 detonations 1970 Split steel tube 1 detonation joints for FerAl conductors, (1RA) 1976-1977 2RA (Norway only) Short type 1979-1980 3RA (Skandinavia) Profiled tubes, spiral 1983-1984 4RA (Dead end / jumper terminal) 2000 VP metall AS buys the product and the rights connected to it, from Raufoss 5

Implosive Connectors Implosive Connectors utilize the energy in a small implosive charge to compress a metal sleeve over conductor or wire. The pressure is applied instantaneously (1/10 000 sec.) and the compression of the sleeve and cable is performed with a high degree of accuracy. 6

Implosive connectors include: full tension joints dead-ends jumper terminals repair sleeves full tension repair joints non-tension sleeves compression rings miscellaneous other fittings The Connectors can be used on dry conductor, fully greased aluminium alloy conductors and ACSR conductors with greased steel core. Connector components have been standardized to fit all common conductor types. 7

Implosive connectors for: Al. conductors from 50mm 2 till 1584 mm 2 FeAl conductors from 50 6/1 till LOMVI (1 detonation) Special conductors (2 detonations) Fjord crossings Steel conductors from 39 mm 2 till 900 mm 2 (Greenland) 8

The system provides: Consistant high quality Optimum compression Only radial deformation Reduced installation time Less total installed cost Faster stringing With this system buying, using, maintaining, storage and transportation of hydraulic presses or other compression tools is unnecessary! 9

Dead-end for ACSR conductor 1 of 2 10

Dead-end for ACSR conductor Dead-end with coil ACSR conductor PVC hose Implosive charge 2 of 2 Al tube with connector pad 11

Full tension repair joint for ACSR conductor 1 of 2 12

Full tension repair joint for ACSR conductor Steel tube with coil ACSR conductor Implosive charge Solid bolt PVC hose Aluminium tube 2 of 2 13

Full tension repair joints 14

Accessories REPAIR SLEEVES Repair sleeves restores the conductivity of a conductor with one or more broken strands. The implosive charge is mounted on one half of the sleeve and is taped together before compression. 15

Accessories COMPRESSION RINGS Compression rings are made for use in handling and sleeving large conductors and special conductors with aluminium alloy strands. They will make the installation work a lot easier. 16

Other areas of use Implosive Connectors may also be used for other purposes. As shown on the next page, Implosive Connectors are used in connecting steel wires between two bridgeheads. Here at the construction of the bridge Höga Kusten on E4 north of Stockholm, Sweden. 17

18

Transition joint (ex. Between Al and ACSR conductor) 19

Testing and quality assuranse: Production VP Metall is certified to meet the requirements in of NS-EN ISO 9001: 2000, and NS-EN ISO 14001: 2004 The implosives connectors are approved for -marking by PvTT. Each new type of Implosive Connectors are tested at Sintef. (Trondheim, Norway) 20

21

22

23

- certificate 24

25

Safety: Wooden boxes for transportation approved by DNV Basis for approval: Drop-test Fall from 25 meters with 3 stk. Curlew connectors, repeated 7 times. CONCLUSION: Deformed connectors, but no detonation of explosives. Hazard-test Detonation test under storage. CONCLUSION: Classification: 1.2 D 1: Mass explosion in one box. 2: No mass explosion in other boxes nearby (no transmission of the detonation). 3: The explosives burned without detonation. 26

Regulation regarding transportation: Each company dealing with Implosive Connectors must be updated on local regulation regarding transportation From VP Metall to our customer: Dangerous goods ADR transport Transportation are carried out by Multisped AS, who have a lot of knowledge about transporting explosives VP Metall s responsibility ends when the goods arrive at the customer Regulations in Norway For transportation and handling less then 20 kg netto explosives: Car: do not transport explosives in the passenger area No requirement regarding marking of the car 27

Storage: Each company dealing with Implosive Connectors must be updated on local regulation regarding storage Local regulations In Norway, permission for storage up to 250 kg are given by local authority s. Requirement regarding personnel who handles the goods: Training and knowledge about handling and storage. 28

ONGOING PROJECTS FOR STATNETT VP metall provides joints, pulling grips, dead ends and jumper terminals for these projects: Sauda Liastølen Sima Samnanger Skogfoss - Varangerbotn 29

Changing old joints Through several years Statnett has replaced old non-implosive joints with implosive repair joints. Including also dead ends and jumper terminals. Repair dead ends, repair sleeves and other special solutions. Customer s request our challenge! 30

Marking on each joint: - Cat.no - Production month and year - CE-no 31

Building transmission lines over 32

a Norwegian Fjord 33

using Dead-ends 34

Pictures from changing Dead Ends at Sognefjorden Lenght across the fjord appr. 4500 meters Break load at 90 tons 35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55