Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

Similar documents
LINEARlight FLEX POWER

Radiance Angle [ ] Color Temp. [K]

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Features. High Brightness LED Light source

T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

PLVZ1-LIN DC > , PLVZ1-LIN DC > ,

Flux CCT. CRI SDCM (lm) (K) (V) (ma) (W) (lm/w)

OPTOTRONIC LED Power Supply OT180W/UNV/800C/2DIMLT2/P6 - Technical Specifications

CHM-27 COB Arrays White LED

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

Lumination LED Luminaires

T5 LongLast. GE Lighting DATA SHEET

JD(Doug) Rooks Western Area Applications Manager

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

High flux for outdoor applications

Kolorlux. GE Lighting DATA SHEET

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

LED Tubular Lamp / Kit Guide

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

MP-1919 XNOVA Cube TM SMD LED

Lumination LED Luminaires

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

LED High Bay FBX. An economical LED high bay Enjoy flexibility and savings along with quality illumination

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

T5 Watt-Miser Linear Fluorescent lamps

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

Evolve LED Garage Light

Flexible LED system approach

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

ADM1TE 5/30A DIN rail single phase two wire energy meter

Fortimo LED Line Gen3

PTU Series Ultrahigh-Purity Pressure Transducers

ST Series POWER SUPPLIES USER INSTRUCTIONS

DuroSite TM High Bay Lighting

STR7 Low Profile LED Strip Luminaire

Multi-Vapor Metal Halide Lamps

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

STRATO LED Drivers 70W, Single output

Evolve LED Roadway Lighting

The Latest in LED Lighting Test Methods and Standards. Jianzhong Jiao, Ph.D. OSRAM Opto Semiconductors Inc.

Lumination LED Luminaires

ALARI LED PARKING, ROADWAY & AREA LIGHTING

Evolve LED Area Light

CERAMIC XENON LAMPS APPLICATIONS FEATURES & BENEFITS VAC CERAMIC XENON LAMPS

Evolve LED Area Light

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

UNRIVALED EMERGENCY SOLUTIONS FOR LEDs CLASS 2 OUTPUT COMPLIANCE WITH AUTO-SENSE FORWARD VOLTAGE

SYLVANIA METALARC Pulse Start Metal Halide Lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Multiple colors, a single focal length

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

LED RETROFIT OPTIONS FOR LINEAR FLUORESCENT LUMINAIRES

LED light engine / OLED LED flexible. Umodule LLE-FLEX umodule LLE FLEX ADVANCED

High Bay Occupancy Sensor Selection Guide

IVIOS LED III. LUM Technical Information

Integration of a 400W ac dc power supply into a closed system relying only on natural convection cooling

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

MINI MCR-SL-R-UI(-SP)

Brilliant Mix System Design. Abstract

LED WALL WASHERS SPECIFICATIONS & INSTALLATION GUIDE

LUXEON S. High Flux Density

Recessed. EvoKit LED Retrofit Kits Gen 3

HL-A-3528H308W-S1-13. Description. Applications. Recommended Soldering. Package Dimensions

C2D LowBay: All the power, none of the bulk. C2D Advantage

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Special Specification 6111 LED Neighborhood Friendly High Mast (NFHM) Illumination Assemblies

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

COLOR VIDEO DOOR PHONE CDV-71BE/D

LUXEON TX Extreme efficacy that will transform your next market leading luminaire

Cree XLamp LED Operating Capacity

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

AOK i Series LED High Bay / Flood / Tunnel Light

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

2087 SERIES 120/277V LED

Manual Ranging MultiMeter

Cree XLamp XM-L LED 10,000-Lumen High-Bay Reference Design

LED Retro Fit the next generation in energy efficiency. Converting existing 12v systems to LED

ARTEMIS acdc1032. A compact, exterior, fully submersible, discrete, triple LED marker light & wallwash luminaire, delivering 350lm.

1247 Norwood Avenue, Itasca, IL (800)

GEMINI SYSTEM LED MODULE 120/277V LED

Product specifications

5W HI-POWER LED SPECIFICATION

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

LED DIMMING A HELPFUL GUIDE...

Understanding LED Drivers

Transcription:

www.osram-americas.com/led Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting Key Features & Benefits High efficacy Boards incorporate multiple LEDs driven at low-current Delivers even and diffuse light Thermally independent requiring no additional heat sinking Simplifies luminaire design Minimizes optical requirements Ideal replacement for linear fluorescent sources 80+ CRI Service life up to 50,000 hours when temperature at Tc point is maintained at 85 C Compatible with 0 10V dimming systems Color variation within a 3-step MacAdam ellipse The Distributed Array LED Module portfolio from OSRAM offers an innovative solution for ambient illumination applications. The Distributed Array boards consist of multiple low-power LEDs in a precise layout that enables thermal self-management, delivers high efficacy at all CCTs and eliminates the need for supplemental heat sinking. The 9" long Distributed Array boards consume about 11 watts of power or less, while the 11" boards consume 9* watts or less. The 18" board consumes 22 watts. The boards produce an even and diffuse light that reduces the need for multiple optical layers, simplifying the luminaire design and maximizing optical efficiency. The Distributed Array products are a long-life, energy-efficient alternative to linear fluorescent sources. The Distributed Array LED Modules are designed for optimum performance when paired with OPTOTRONIC constant current power supplies for maximum system efficiency and life expectancy. Product Offering Ordering Abbreviation Nominal Length (LxW) Color L11LRE/320C/830/DA/9IN 9"x2" 3000K L11LRE/320C/835/DA/9IN 9"x2" 3500K L11LRE/320C/840/DA/9IN 9"x2" 4000K L11LRE/300C/830/DA24/9IN 9"x1.5" 3000K L22LRE/300C/832/DA48/18IN 18"x1.5" 3250K L11LRE/300C/835/DA24/9IN 9"x1.5" 3500K L11LRE/300C/840/DA24/9IN 9"x1.5" 4000K L9LRE/250C/830/DAL/11IN 11"x1.5" 3000K L9LRE/250C/835/DAL/11IN 11"x1.5" 3500K L9LRE/250C/840/DAL/11IN 11"x1.5" 4000K L9LRE/250C/830/DAL/11_6IN 11.6"x2" 3000K L9LRE/250C/835/DAL/11_6IN 11.6"x2" 3500K L9LRE/250C/840/DAL/11_6IN 11.6"x2" 4000K *at optimized currents Application Information Applications Accent/decorative lighting General lighting Office lighting Task lighting Undercabinet lighting Specifications and Certifications The OSRAM Distributed Array Family is UL8750 Recognized for US and Canada Class 2 Units (UL File# E320662). LED226R4 2-14

Specification Data Catalog # Project Comments Prepared by Type Date Ordering Information Optimized Max Rated Initial Item Ordering Input Input Dimensions Qty. of Nominal Color Lumens Number Abbreviation Current (ma) Current (ma) (L x W) LEDs Wattage (W)* Temperature CRI (lm)* 74800 L11LRE/320C/830/DA/9IN 320mA 350mA 9" x 2" 48 11.19 3000K >80 1020 74801 L11LRE/320C/835/DA/9IN 320mA 350mA 9" x 2" 48 11.04 3500K >80 1080 74802 L11LRE/320C/840/DA/9IN 320mA 350mA 9" x 2" 48 11.16 4000K >80 1170 71064 L9LRE/250C/830/DAL/11IN 250mA 350mA 11.375" x 1.5" 30 8.69 3000K >80 864 71065 L9LRE/250C/835/DAL/11IN 250mA 350mA 11.375" x 1.5" 30 8.76 3500K >80 938 71066 L9LRE/250C/840/DAL/11IN 250mA 350mA 11.375" x 1.5" 30 8.72 4000K >80 958 71250 L9LRE/250C/830/DAL/11_6IN 250mA 350mA 11.612" x 2" 30 8.69 3000K >80 864 71251 L9LRE/250C/835/DAL/11_6IN 250mA 350mA 11.612" x 2" 30 8.76 3500K >80 938 71252 L9LRE/250C/840/DAL/11_6IN 250mA 350mA 11.612" x 2" 30 8.72 4000K >80 958 71115 L11LRE/300C/830/DA24/9IN 300mA 300mA 9" x 1.5" 24 10.8 3000K >80 900 71116 L22LRE/300C/832/DA48/18IN 300mA 300mA 18" x 1.5" 48 21.6 3250K >80 1900 71117 L11LRE/300C/835/DA24/9IN 300mA 300mA 9" x 1.5" 24 10.8 3500K >80 1020 71118 L11LRE/300C/840/DA24/9IN 300mA 300mA 9" x 1.5" 24 10.8 4000K >80 1035 *Nominal ratings at 25 C ambient and at optimized input current listed. Notes: 1. All data is related to the entire module. Data reflects statistical mean values. Actual data may differ depending on variances in the manufacturing process. 2. Performance values were taken at steady state. Instant-on measurements may be higher. Ordering Guide L 11 L R E / XXXC / 8 30 / DA X / XX_XIN LED Wattage Linear Rigid Engine Current CRI>80 CCT Product Family Length in ma 30 = 3000K Distributed 32 = 3250K Array 35 = 3500K 40 = 4000K Power Supply Information OPTOTRONIC OPTOTRONIC Programmable Programmable OPTOTRONIC Compact* Linear* Step-DIM* Product OT25W OT40W OT30W OT48W OT50W 79376 & 79377 All Item Numbers Note: These are single-channel power supplies. Minimum and Maximum Ratings Parameter Operating Temperature at Tc Point Storage Temperature Range Notes: 1. Exceeding maximum ratings may damage the LED module and cause potential safety hazards. 2. Elevated operating temperatures can be expected to negatively impact the service life in terms of lumen output. 3. Incorrect wiring may damage the LED module. 4. Intended for use with OPTOTRONIC OT50 constant current power supplies. Values -30 to +85 C (-22 to +185 F) -30 to +80 C (-22 to +176 F)

Ordering Description Ordering Description CCT Current (ma) Voltage Lumens Watts Lumens / Watt Temp at Tc ( C) Item Number 71064 3000K 350 36 1118 12.53 89 65 and 71250 3000K 320 35 1047 11.36 92 61 3000K 300 35 997 10.59 94 59 3000K 280 35 945 9.83 96 57 3000K 250 35 864 8.69 99 53 3000K 200 34 716 6.84 105 48 3000K 150 34 560 5.04 111 41 Item Number 71065 3500K 350 36 1208 12.62 96 63 and 71251 3500K 320 36 1132 11.44 99 60 3500K 300 36 1079 10.67 101 58 3500K 280 35 1023 9.90 103 55 3500K 250 35 938 8.76 107 52 3500K 200 34 779 6.89 113 46 3500K 150 34 609 5.07 120 41 Item Number 71066 4000K 350 36 1239 12.58 98 64 and 71252 4000K 320 36 1160 11.40 102 61 4000K 300 35 1105 10.63 104 58 4000K 280 35 1048 9.86 106 56 4000K 250 35 958 8.72 110 53 4000K 200 34 796 6.86 116 48 4000K 150 34 619 5.05 123 39 2. LED modules were designed to be optimized at 900 lumens and approximately 100 LPW. Driving the boards at 250 ma at all CCTs meets or exceeds these targets. Boards may be driven up to 350 ma. Consult the OPTOTRONIC OT50 product information bulletin #ECS146 for driver specifications. Ordering Description CCT Current (ma) Voltage Lumens Watts Lumens / Watt Temp at Tc ( C) Item Number 74800 3000K 350 35 1089 12.30 89 55 3000K 320 35 1021 11.19 91 51 3000K 300 35 971 10.45 93 49 3000K 280 35 920 9.72 95 47 3000K 250 35 839 8.62 97 44 3000K 200 34 692 6.81 102 40 3000K 150 34 534 5.03 106 35 Item Number 74801 3500K 350 35 1168 12.15 96 52 3500K 320 35 1086 11.04 98 49 3500K 300 34 1030 10.30 100 47 3500K 280 34 972 9.57 102 45 3500K 250 34 882 8.49 104 42 3500K 200 34 724 6.71 108 38 3500K 150 33 556 4.96 112 35 Item Number 74802 4000K 350 35 1256 12.28 102 51 4000K 320 35 1169 11.16 105 47 4000K 300 35 1109 10.41 107 46 4000K 280 35 1048 9.67 108 43 4000K 250 34 952 8.58 111 41 4000K 200 34 782 6.76 116 36 4000K 150 33 603 5.00 121 32 2. Boards were designed to be optimized at 1100 lumens and approximately 100 LPW. Driving the boards at 320 ma at all CCTs meets or exceeds these targets. Boards may be driven up to 350 ma. Consult the OPTOTRONIC OT50 product information bulletin #ECS146 for driver specifications. Item Number CCT Current (ma) Voltage Lumens Watts Lumens / Watt Temp at Tc ( C) 71115 3000K 300 36 900 10.8 83 72 71116 3250K 300 36 1900 21.6 88 69 71117 3500K 300 36 1020 10.8 94 72 71118 4000K 300 36 1035 10.8 96 71

Assembly Diagram 48 LED 9" x 2"Board 24 LED 9" x 1.5" Board 48 LED 18" x 1.5" Board 30 LED 11.375" x 1.5" Board 30 LED 11.612" x 2" Board Dimensions in mm

Wiring Diagram Warranty OPTOTRONIC OTXX 4-Channel Power Supply Black (L) White (N) VOLTAGE 120-277 V AC 50/60Hz INPUT OUTPUT CONTROL 0-10 V DC DC (+) CH1 B(-) CH2 B(-) CH3 B(-) CH4 B(-) Purple (+) Red Gray (-) OSRAM LED products are covered by our LED Module, OPTOTRONIC Power Supply or Control warranty. The Distributed Array LED Module Portfolio is covered under warranty as long as the temperature at the Tc point does not exceed 85 C; exceeding this temperature will void all warranties. For additional information or to download the warranty registration form, refer to the latest version of the warranty (LED089) available in the Literature section of www.osram-americas.com/led. Module Warranty: 3 years System Warranty: 5 years Safety Information WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION. TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR LIGHT ENGINES. Failure to install the power supplies and/or LED light engines in accordance with the National Electric Code (NEC), all applicable Federal, State and local electric codes as well as the specific Underwriters Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property damage and/or product malfunction. 1. The LED module itself and all its components shall not be subjected to mechanical stress and assembly must not damage or destroy conducting paths on the circuit board. 2. Observe correct electrical polarity, incorrect polarity may destroy the module. (Depending on the product, incorrect polarity may lead to emission of red or no light.) 3. Ensure the power supply is of adequate power to operate the total load. 4. Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the module. (For more information, reference document # LED093 ESD Protection for LED Systems.) 5. Installation of LED modules shall be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. 6. Modules may be hot to the touch. Use caution when handling. 7. Damage by corrosion and improper heat sinking will not be honored as a materials defect claim. It is the user s responsibility to ensure adequate heat sink and protection against corrosive agents such as moisture, condensation and other harmful elements. Assembly Information 1. The PrevaLED Line, Bar and Panel needs no supplemental heat sinking when the temperature at the Tc Point is maintained at or below 85 C. Service life when the Tc temperature is maintained is 50,000 hours/l 70. When the environment is unknown, the Distributed Array products should be installed in luminaires designed to provide proper thermal management to avoid premature failure of the product and to obtain expected service life. Service life (i.e. lumen depreciation) is primarily a function of LED temperature, which is to be monitored on the circuit board at the designated Tc Point. 2. Due to variations in fixture designs, there is no exact installation prescription for obtaining an appropriate Tc Point temperature. In general, the PrevaLED Line, Bar and Panel should be adhered to a flat metal surface which has enough surface area to transfer the heat from the LEDs to the surrounding air. In some cases, the metal surface can be part of the mass of the fixture itself. 3. It is important to understand that once heat is transferred to a heat sink that heat must still be allowed to escape the system. A heat sink transferring the thermal energy to the inside of an enclosed cavity may ultimately be of little use. 4. Tc Point temperature measurements should be taken with the modules operating at thermal equilibrium in potential fixture designs installed in an appropriate environment. Tc Point temperature can be measured with a standard thermocouple in direct contact with the circuit board at the Tc Point or with ML4C Series non-reversible OMEGALABELS (www.omega.com) or equivalent. 5. The 2" wide PrevaLED Line, Bar and Panel take a #6-32 screw. The 1.5" wide boards take a 3mm screw. OSRAM, LED CREATING TOMORROW and OPTOTRONIC are registered trademarks of OSRAM GmbH. Specifications subject to change without notice. United States OSRAM SYLVANIA 100 Endicott Street Danvers, MA 01923 1-800-LIGHTBULB Trade Phone: 800-255-5042 Fax: 800-255-5043 National Accounts Phone: 800-562-4671 Fax: 800-562-4674 OEM/Special Markets Phone: 800-762-7191 Fax: 800-762-7192 Retail Phone: 800-842-7010 Fax: 800-842-7011 SYLVANIA Lighting Services Phone: 800-323-0572 Fax: 800-537-0784 Display/Optic Phone: 888-677-2627 Fax: 855-543-1043 Canada OSRAM SYLVANIA LTD. 2001 Drew Road Mississauga, ON L5S 1S4 1-800-LIGHTBULB Trade Phone: 800-263-2852 OEM/Special Markets/Display/Optic Phone: 800-265-2852 Retail Phone: 800-720-2852 SYLVANIA Lighting Services Phone: 800-663-4268 Fax: 866-239-1278 Mexico OSRAM MEXICO Tultitlan/Edo de Mexico Phone: 011-52-55-58-99-18-50 ENCELIUM Products United States Phone: 201-508-1570 Fax: 201-508-1589 Canada Phone: 905-731-7678 Fax: 905-731-1401 www.osram-americas.com 2014 OSRAM 2-14