Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)



Similar documents
Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Automatic Bypass Control AVDO

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Data sheet ECC 12 and 22

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Data sheet Thermostatic sensors type RA 2000

Thermostatic element RAVV for 2-way valves

Mikrotherm. Manual radiator valves. To be precise.

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Thermostatic valve Type AVTA

Automatic balancing valves ASV

Thermostatic Actuators

stainless steel pre-assembled manifolds

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Assisted lift operated 2/2-way solenoid valves Type EV250B

VALVES FOR REFRIGERATING SYSTEMS

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Self-operated Temperature Regulators Temperature Regulator Type 1u

Solenoid valves 2/2-way direct-operated Type EV210A

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Globo P. Ball valves Pump ball valve made of gunmetal

Stainless steel process fittings

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

kymanual or Automatic - it s your Choice

Digital inductive conductivity transmitter

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Solenoid valves Type EVU

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

3/2-way Mini Solenoid Valve

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

AMX300 DirectConnect Mixing Valve Kits

Hose and Tube Fittings Series 1-3

REGULATORS 175/153 Series

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Type 3353 Angle Seat Valve

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

API Flanged Safety Relief Valves Series 526 CATALOG

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Water Pump Replacement

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

3/2-way Solenoid Valve, direct-acting, NC or NO

Radiator valve accessories

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Water valves REFRIGERATION AND AIR CONDITIONING. Fitters notes

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Installation Instructions S

Low-H2O valves Y EARS

Stainless Steel Single and Dual Circulation Kits

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Valve systems Base plates, according to standard ISO Brochure

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

RADIATOR VALVE. type m72. Page 1

Model 5600 & 5600 Econominder

2- and 3-port valves with flanged connections, PN 10

Overview of types. Technical data

Powers Controls TH 192 S Single Temperature Room Thermostat

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

NFPA31FuelOilPiping 1 Revised

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Pressure switches and thermostats, type KPS

2/2 and 3/2 Way Size 6 Seat Valves

Direct steam injection humidifiers

SISTO-16TWA/HWA/DLU. Type Series Booklet

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

ECOCIAT. Domestic hot water heat recovery unit

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Butterfly Valves PN 6/10/16 for flanged connection

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

STABITHERM INSTALLATION & SERVICE BOOKLET

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

SWIMMING POOL HEAT PUMP Owners Manual

Control blocks for two-hand start ZSB

How To Use A Flowmeter

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Automatic control equipment for HVAC systems

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

E v e r i n c r e a s i n g i n n o v a t i o n. R A R a n g e. C o m m e r c i a l T R V s

Thermostats. Technical information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Transcription:

Data Sheet Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity) Application RAS-C² thermostatic sensor RA-FN angle valve The RAS-C² thermostatic sensor is a selfactuating proportional controller with a small Pband. RAS-C² has a temperature range from 8 to 28 C and is equipped with frost protection setting and positive shut-off for maximum user flexibility. The RAS-C² thermostatic sensor and the RA-FN valves are designed for use in 2-pipe domestic heating systems. The valves are manufactured from brass with nickel plating. The pressure pin of the gland seal is of chromium steel and works in a lifetime lubricated O-ring seal. The complete gland assembly can be replaced without draining down the system. Approved to EN 215 Ordering and Specifications The valves are supplied with a grey protective cap, which can be used for manual regulation during the construction phase. The protective cap must not be used as a manual shut off device. A special manual shut off device (code no. 013G5000) should be used. Compression fittings for 15 mm, 10 mm or 8 mm copper tube are available. In order to avoid deposition and corrosion, the composition of the hot water must be in accordance with the VDI 2035 guideline (Verein Deutscher Ingenieure). It is recommended that formulations containing mineral oil are avoided. Thermostatic sensors RAS-C² with RA-FN radiator valves (fixed capacity) are manufactured to the highest standards, and are approved to the European standard EN 215. RAS-C² thermostatic sensor Type RAS-C² Danfoss Heating Solutions RA-FN straight valve Design Built-in sensor, frost protection, positive shutoff VDAVH202 Danfoss 03/2011 Setting range 1) 8-28 C Code no. 013G6040 1

RA-N radiator valves Type Design Connec-tions k v -value 1) (m³/h at 1 bar pressure drop) P-band = K Inlet Outlet 0.5 K 1.0 K 1.5 K 2.0 K k vs Max. work. temp. Code no. RA-FN 10 Angle R p 3/8 R 3/8 0.17 0.34 0.47 0.56 0.65 120 C 013G0001 RA-FN 10 Straight R p 3/8 R 3/8 0.17 0.34 0.47 0.56 0.65 120 C 013G0002 RA-FN 15 Angle R p 1/2 R 1/2 0.22 0.43 0.57 0.73 0.90 120 C 013G0003 RA-FN 15 Straight R p 1/2 R 1/2 0.22 0.43 0.57 0.73 0.90 120 C 013G0004 Technical data Max. working pressure: 10 bar, max. diff. 2) pressure: 0.6 bar, test pressure: 16 bar 1) The k v -value indicates the water flow (Q) in m³/h at a pressure drop ( p) across the valve of 1 bar;. At setting N the k v -value is stated according to EN 215, at X P = 2K i.e. the valve is closed at 2 C higher room temperature. At lower settings the X P value is reduced to 0.5K of the setting value 1. The k vs -value states the flow Q at a maximum lift, i.e. at fully open valve at setting N. 2) Working pressure = static + differential pressure. The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regulation. As with any device which imposes a pressure drop in the system, noise may occur under certain flow/pressure conditions. To ensure quiet operation, maximum pressure drop should not exceed 30 to 35 kpa. The differential pressure can be reduced by the use of the Danfoss differential pressure regulators types AVD, AVDL, AVDS, IVD or ASV-P. Thermostatic Efficiency Label Manufacturer: Model: Registration number: Danfoss A/S RAS C2 6040 10014 20090331 Information: www.tell online.eu A Label of EUnited Valves European Valve Manufacturers Association Accessories Product Dimension For valve body Code no. Gland seal All RA-N valves 013G0290 2 VDAVH202 Danfoss 03/2011 Danfoss Heating Solutions

Compression fitting for steel and copper tubes Rp 3/8 x Ø10 mm Rp 3/8 x Ø12 mm Rp 1/2 x Ø10 mm Rp 1/2 x Ø12 mm Rp 1/2 x Ø15 mm RA-N 10 RA-N 15 013G4100 013G4102 013G4110 013G4112 013G4115 All accessories comes in boxes of 10 pcs. Sensor Mounting 1. 2. Remove the valve protection cap. Turn the sensor to, then turn the union nut as much as possible to the right. 3. 4. Mount the sensor with the scale pointer upwards. Press the sensor firmly onto the valve. 5. 6. Secure connection by turning the union nut clock-wise by hand. Fully tighten the grey union nut using a pair of parrot nose pliers. Danfoss Heating Solutions VDAVH202 Danfoss 03/2011 3

Capacities RA-FN DN10 [mwg] Q [l/h] RA-FN DN15 [mwg] Q [l/h] 4 VDAVH202 Danfoss 03/2011 Danfoss Heating Solutions

Design RAS-C² 1. Actuator 2. Setting dial 3. Safety spring 4. Bellows 5. Spindle 6. Socket 7. Union nut 1 2 3 4 5 6 7 RA-N 1. Gland seal 2. O-Ring 3. Pressure pin 4. Seal 5. Regulation spring 6. Setting dial 7. Valve body 8. k v -nozzle Materials in contact with water Valve body and other metal parts O-ring Valve cone Pressure pin and valve spring Nozzle Ms 58, brass EPDM NBR Chrome/Steel PP Dimensions ø50 S 2 d 2 76.9-83.8 H 2 H 1 H 3 S 1 S 2 d 2 H 2 L 5 H 1 H 3 D L 1 d 1 S 1 d 1 13 L 2 D L 3 L 4 ø40.5 Type ISO 7-1 Arc. flats L 1 L 2 L 3 L 4 L 5 H 1 H 2 H 3 D d 1 d 2 S 1 S 2 RA-N 10 G 3/8 G 5/8 A R 3/8 50 75 24 49 20 47 50 15 22 27 RA-N 15 G 1/2 G 3/4 A R 1/2 55 82 26 53 23 47 50 15 27 30 Danfoss Heating Solutions VDAVH202 Danfoss 03/2011 5

6 VDAVH202 Danfoss 03/2011 Danfoss Heating Solutions

Danfoss Heating Solutions VDAVH202 Danfoss 03/2011 7

Danfoss A/S Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone:+45 7488 8000 Fax: +45 7488 8100 Email: heating.solutions@danfoss.com www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 VDAVH202 Danfoss 03/2011 Danfoss Heating Solutions