Power consumption (kw)



Similar documents
UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

ECOCIAT. Domestic hot water heat recovery unit

AQUADA UV Eliminate Bacteria in Your Drinking Water!

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Alfa Laval PureBallast 3.1

User Manual: C Long Point Houston, TX Facebook.com/CoolAZone Twitter.com/CoolAZone

API Marine. BMS Presentation. Ballast Measurement Systems

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

TMS TANK MANAGEMENT SYSTEM

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Refrigeration Compressed Air Dryer Buran Ultrapulse

Duron UV System YoU adjust to changing conditions it S time YoUr UV SYStem DoeS too

Clinic Washer-Disinfectors. Washer-Disinfector Line

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

Sap Steady UV Unit for Maple Sap

LC/LCD ranges level controllers

IFC 070 Technical Datasheet

Please also see 10 golden rules for correct Saniflo installation on

Incubator with mechanical convection

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Hydraulic Control Solutions

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Electric Flow Boiler

Climate chamber with illumination

Vacuum drying oven for non-flammable solvents

Technical data. Danfoss DHP-A

COMBIMASS. Technical Data COMBIMASS eco-bio +

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Photovoltaic Solar Energy Unit EESFB

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

The kva RAnge

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

CATALOGUE BIOSAFETY EQUIPMENT: UV CLEANER-RECIRCULATORS, DNA/RNA UV CLEANER BOXES, LAMINAR FLOW CABINET, MULTI-CLEANER XL

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

STERILIZERS, LABORATORY DRYING OVENS

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

Magnum Mobile Generator MMG55 Specifications

Condensing unit type EPSILON-ECHOS LE Technical information manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Heating, air-conditioning, cooling

Centro-Matic Automatic Lubrication Systems System Controls

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Conlift1, Conlift2, Conlift2 ph+

Digital inductive conductivity transmitter

ELECTRIC CENTRAL HEATING FLOW BOILER

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Material test chamber with mechanical convection

Heating oven with mechanical convection

KNC Model 3666 Automatic Pressure Calibration System

Basics of UV Disinfection

Adsorption air dryers ADS 1 215

Kompressoren. Adsorption Dryer AD

ThermoSorb Desiccant Dryers

CRAC Precision climate control units for data centres

HEAVY WATER LEAK DETECTOR

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Thyristor-controlled power supplies and battery chargers

Solar Hot Water Heaters

CoolTeg Plus Chilled Water (CW) version: AC-TCW

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

GenStore Archive Cabinet

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

HUBER Vacuum Rotation Membrane VRM Bioreactor

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Testomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Stove-boiler for solid fuels KW Directions for use and assembling

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

BB-18 Black Body High Vacuum System Technical Description

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Morgue refrigeration unit

LK Electric Boiler - 4,5

HYDRUS ULTRASONIC METER

VDL 53 - Vacuum drying oven for flammable solvents

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

Copa Raked Bar Screen

Mission Hill Water Treatment Plant & Kalamalka Lake Pump Station Upgrades

Transcription:

OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components integrated in a compact stainless steel chamber and separate electrical cabinet. OS units were designed and are manufactured according to international standards for UV disinfection of wastewater water. Type Number of UV lamps Nominal flow rate* (m 3 /h) Power consumption (kw) Connection flanges Control cabinet type Cleaning system type OS-1A 1 13 0,28 DN 50 Type 2 WB-2 OS-2A 2 25 0,56 DN 50 Type 2 WB-2 OS-4A 4 70 1,12 DN 100 Type 2 WB-5C OS-5A 5 86 1,4 DN 100 Type 2 WB-5C OS-7A 7 130 2 DN 100 Type 3 WB-5C OS-12A 12 220 3,2 DN 250 Type 3 WB-5C OS-18A 18 329 5 DN 300 Type 3 WB-5C OS-36A 36 661 10 DN 400 Type 3 WB-5C 2 * 300 J/m at 70% water transmittance at the end of lamp life. Application LIT OS series units are applied for: - municipal and industrial wastewater disinfection; - process water and industrial recirculated water; - irrigation water; - sea- water. - Advantages - reliable disinfection with low energy consumption; - high-power amalgam lamp technology; - compact design in combination with large flow capacities; - reliable operation and long service life; - easy operation and maintenance. 0902-01

OS System Description and Components Principle of operation UV reactor of OS units has a longitudinal geometry with side inlet/outlet flanges. Water enters the chamber and is exposed to germicidal radiation destructive for bacteria and viruses. UV lamps are isolated from treated water by special quartz sleeves made of high quality fused quartz with high transmission coefficient for ultraviolet radiation (95%). After UV treatment water doesn't contain microorganisms dangerous to health and is instantly ready for use. UV Dose OS units ensure high UV dose in a wide range of water transmission values. The minimal required dose is guaranteed over all time of lamps life taking into account lamps aging. UV Lamps All units are equipped with modern, industrially manufactured amalgam lamps having long service life and enhanced UV-C output. Low depreciation of UV-radiation intensity at the end of lamp life guarantees effective disinfection during the whole operation period of OS units. UV sensor According to Russian Hygiene Governmental Authority all OS units are equipped with UV-radiation intensity sensor. It allows to continuously monitor UV dose and generate alarm signals when UV dose drops lower than necessary level. Control Cabinet Proper operation of UV system is provided through control cabinet according to the table above. LIT OS systems are supplied with two types of control cabinet described below. Cleaning System Standard delivery package of all LIT OS units includes a special chemical cleaning system for regular cleaning of disinfection chamber and quartz sleeves. Chemical cleaning system consists of stainless steel tank, water pump and set of pipes. The tank is used for preparation of cleaning solution. The water pump provides circulation of water mixed with cleaning solution through the chamber. The 0.2 % aqueous solution of citric or oxalic acid is used for periodical cleaning (once 2-3 months) of disinfection chamber. Chemical cleaning method provides effective removal of fouling from quartz sleeves and inner walls of disinfection chamber and requires minimum labour and material resources. 0902-02

OS-1A UV System View without ballast cabinet 1 - UV chamber, 2 - UV lamp, 3 - quartz sleeve, 4 - ballast cabinet, 5 - input/output flanges (2 ), 6 - cleaning valves (3/4 ), 7 - sampling valves, 8 - UV sensor. UV-unit type OS-1A Nominal flow rate (300 J/m 2 at 70% water transmittance) 13 m 3 /h Number of UV-lamps per unit 1 UV-lamp type DB-300 Guaranteed lifetime of the lamp 12 000 hours UV chamber material Stainless steel 304/316* Chamber volume 7,5 liters Maximum operating pressure 8 bar UV chamber protection class IP 65 Dry chamber weight 37 kg Power consumption 220 V / 50-60 Hz / 0,28 kw Power factor >0,96 Connection DN 50 Water temperature 1 C 30 C Head loss See diagram below 0902-03

OS-2A UV System View without ballast cabinet 1 - UV chamber, 2 - UV lamp, 3 - quartz sleeve, 4 - ballast cabinet, 5 - input/output flanges (2 ), 6 - cleaning valves (3/4 ), 7 - sampling valves, 8 - UV sensor. UV-unit type OS-2A Nominal flow rate (300 J/m 2 at 70% water transmittance) 25 m 3 /h Number of UV-lamps per unit 2 UV-lamp type DB-300 Guaranteed lifetime of the lamp 12 000 hours UV chamber material Stainless steel 304/316* Chamber volume 15 liters Maximum operating pressure 8 bar UV chamber protection class IP 65 Dry chamber weight 60 kg Power consumption 220 V / 50-60 Hz / 0.56 kw Power factor >0,96 Connection DN 50 Water temperature 1 C 30 C Head loss See diagram below 0902-04

OS-4A UV System View without protective cap View without ballast cabinet 1 - UV chamber, 2 - UV lamp, 3 - quartz sleeve, 4 - ballast cabinet, 5 - input/output flanges (2 ), 6 - cleaning valves (3/4 ), 7 - sampling valves, 8 -protective housing, 9 - air release valve, 10- drainage valve, 11 - UV sensor. UV-unit type OS-4A Nominal flow rate (300 J/m 2 at 70% water transmittance) 70 m 3 /h Number of UV-lamps per unit 4 UV-lamp type DB-300 Guaranteed lifetime of the lamp 12 000 hours UV chamber material Stainless steel 304/316* Chamber volume 61 liters Maximum operating pressure 8 bar UV chamber protection class IP 65 Dry chamber weight 74 kg Power consumption 220 V / 50-60 Hz / 1,12 kw Power factor >0,96 Connection DN 100 Water temperature 1 C 30 C Head loss See diagram below 0902-05

OS-5A UV System View without protective cap View without ballast cabinet 1 - UV chamber, 2 - UV lamp, 3 - quartz sleeve, 4 - ballast cabinet, 5 - input/output flanges, 6 - cleaning valves (3/4 ), 7 - sampling valves, 8 - protective cap, 9 - air release valve, 10- drainage valve, 11- UV sensor. UV-unit type OS-5A Nominal flow rate (300 J/m 2 at 70% water transmittance) 86 m 3 /h Number of UV-lamps per unit 5 UV-lamp type DB-300 Guaranteed lifetime of the lamp 12 000 hours UV chamber material Stainless steel 304/316* Chamber volume 60 liters Maximum operating pressure 8 bar UV chamber protection class IP 65 Dry chamber weight 77 kg Power consumption 220 V / 50-60 Hz / 1,4 kw Power factor >0,96 Connection DN 100 Water temperature 1 C 30 C Head loss See diagram below 0902-06

OS-7A UV System View without protective cap View without ballast cabinet 1 - UV chamber, 2 - UV lamp, 3 - quartz sleeve, 4 - ballast cabinet, 5 - input/output flanges, 6 - cleaning valves (3/4 ), 7 - sampling valves, 8 - protective cap, 9 - air release valve, 10 -drainage valve, 11 - UV sensor UV-unit type OS-7A Nominal flow rate (300 J/m 2 at 70% water transmittance) 130 m 3 /h Number of UV-lamps per unit 7 UV-lamp type DB-300 Guaranteed lifetime of the lamp 12 000 hours UV chamber material Stainless steel 304/316* Chamber volume 100 liters Maximum operating pressure 8 bar UV chamber protection class IP 65 Dry chamber weight 110 kg Power consumption 220 V / 50-60 Hz / 2 kw Power factor >0,96 Flanges diameter DN 100 Water temperature 1 C 30 C Head loss See diagram below 0902-07

OS-12A UV System View without protective cap 1 - UV chamber, 2 - UV lamp, 3 - quartz sleeve, 4 - input/output flanges, 5 - cleaning valves (3/4 ), 6 - sampling valves, 7 - air release valve, 8 - drainage valve, 9 - protective cap, 10- UV sensor. UV-unit type OS-12A Nominal flow rate (300 J/m 2 at 70% water transmittance) 220 m 3 /h Number of UV-lamps per unit 12 UV-lamp type Guaranteed lifetime of the lamp DB-300 12 000 hours UV chamber material Stainless steel 304/316* Chamber volume Maximum operating pressure 220 liters 8 bar UV chamber protection class IP 65 Dry chamber weight Power consumption 285 kg 220 V / 50-60 Hz / 3,2 kw Power factor >0,96 Connection DN 250 Water tem perature 1 C 30 C Head loss See diagram below 0902-08

OS-18A UV System View without protective cap 1 - UV chamber, 2 - UV lamp, 3 - quartz sleeve, 4 - input/output flanges, 5 - cleaning valves (3/4 ), 6 - sampling valves, 7 - air release valve, 8 - drainage valve, 9 - protective cap, 10- UV sensor. UV-unit type OS-18A Nominal flow rate (300 J/m 2 at 70% water transmittance) 329 m 3 /h Number of UV-lamps per unit 18 UV-lamp type DB-300 Guaranteed lifetime of the lamp 12 000 hours UV chamber material Stainless steel 304/316* Chamber volume 263 liters Maximum operating pressure 8 bar UV chamber protection class IP 65 Dry chamber weight 295 kg Power consumption 220 V / 50-60 Hz / 5 kw Power factor >0,96 Connection DN 300 Water temperature 1 C 30 C Head loss See diagram below 0902-08

OS-36A UV System View without protective cap 1 - UV chamber, 2 - UV lamp, 3 - quartz sleeve, 4 - input/output flanges, 5 - cleaning valves (3/4 ), 6 - sampling valves, 7- air release valve, 8 - drainage valve, 9 - protective cap, 10 -UV sensor. UV-unit type OS-36A Nominal flow rate (300 J/m 2 at 70% water transmittance) 661 m 3 /hr Number of UV-lamps per unit 36 UV-lamp type DB-300 Guaranteed lifetime of the lamp 12 000 hours UV chamber material Stainless steel 304/316* Chamber volume 465 liters Maximum operating pressure 8 bar UV chamber protection class IP 65 Dry chamber weight 390 kg Power consumption 220 V / 50-60 Hz / 10 kw Power factor >0,96 Connection DN 400 Water temperature 1 C 30 C Head loss See diagram below 0902-09

Example of typical installation of OS plants 1- UV chamber, 2- control/ballast cabinet, 3- chemical cleaning system, 4-support frame. Service area for lamp replacement Installation instructions - OS units must be installed according to the instructions provided in Installation, Operating and Maintenance Manual supplied with unit. 2 - Water pressure in connecting pipes should not exceed 8 kg/cm (8 Bar). - It is recommended to equip water supply pipe with flow-meter and flow regulating device. - Sufficient space has to be allocated to install the components of the UV system and provide free access to them during maintenance and repair works. Special service zones should be provided as it is indicated in assembly drawing. - The control cabinet should be fixed on the wall or frame in easily accessible place convenient for observation of the front panel. - In the operating area temperature must be kept within the range of + 1C + 35C, humidity - not more than 80%. 0902-11

Control cabinet. TYPE 2 General description Control and monitoring of UV system operation is performed through control cabinet. LIT control cabinet (type 2) consists of plastic (or optional stainless steel) housing with glass front door. Through the door one can see folding front panel that serves for monitoring and control. There are liquid crystal display, keyboard, system on/off button and light indicators placed on the panel. 1 - housing, 2 - glass door, 3 - bracing, 4 - hermetic lead-in, 5 - latch, 6 - bolding front panel, 7 - LC Display, 8 - keyboard, 9 - on/off button. Control capability 1. Local switching on/off the UV plant Applicable UV units OS-1A OS-2A OS-4A OS-5A OS-7A Electricity requirements 220V / 50-60Hz Weight 10 kg Dimensions, mm 329 x 379 x 219 Protection class IP 65 Monitoring capability Local: 1. UV system on/off status 2.Operation status (normal operation, warning, failure) 3. UV intensity in the chamber (W/m2 or %) 4. Number of on/off cycles 5. Total operation time of UV system 6. Total operation time of UV lamps 7. Status of each lamp 8. Critical temperature in ballast cabinet 9. Critical temperature of treated water Remote: 1.UV system on/off status (through dry contacts) 2.Operation status: normal operation, warning, failure (through dry contact) 3.UV intensity in the chamber (through 4 20 ma signal) 0902-12

Control cabinet. TYPE 3 General description Control and monitoring of UV system operation is performed through control cabinet. LIT control cabinet (type 3) consists of painted steel (or optional stainless steel) housing with front door. On the front door there is a sighting window made of glass. Behind the window there is front panel that serves for monitoring and control. The liquid crystal display, keyboard, control buttons and light indicators are placed on the panel. The electronic ballasts are mounted inside the housing. 1 - housing, 2 - base, 3 - glass window, 4 - front panel, 5 - eye-bolt, 6 - latch. Applicable UV units OS-12A OS-18A OS-36A Electricity Protection Weight Dimensions, mm requirements class 220 V / 50-60Hz Max 200 kg 600 x 2230 x 600 IP 54 There are two main operating modes of the control cabinet: - local - through keyboard and buttons on the panel of the cabinet - remote control from central control room of water treatment plant - through dry contacts or RS-485 serial bus Monitoring capability (in both local and remote modes): 1. UV system on/off status 2. Operation status (normal operation, warning, failure) 3. UV intensity in the chamber (W/m2 or %) 4. Number of on/off cycles 5. Total operation time of UV system 6. Total operation time of UV lamps 7. Status of each lamp 8. Critical temperature in control cabinet 9. Critical temperature of treated water Control capability 1.Local switching on/off the UV plant 2.Local switching on/off the chemical cleaning pump 3.Remote switching on/off the UV plant 0902-13

Chemical cleaning system WB-2 General description The chemical cleaning system consists of circulation pump, stainless steel tank for preparation of cleaning solution, pipes and valves. The cleaning tank and pump are connected with flexible pipe. Cleaning is carried out with oxalic (or citric) acid, which is supplied in the form of powder and dissolved in the tank before cleaning. When the pump is on the water mixes with cleaning solution and circulates through UV chamber. After cleaning the water is removed out of the chamber through water discharge tap mounted on the chamber. 1- tank for cleaning solution, 2 - pump, 3 - inlet connection, 4 - outlet connection, 5 - drain valve, 6 - reservoir for cleaning agent, 7 - tank cap. System type WB-2 Cleaning tank material Stainless steel 304/316* Cleaning tank volume, l 0,7 Connection pipes DN 25 Cleaning agent Oxalic acid Electricity requirements 220 V, 50-60 Hz Power consumption, kw 0,72 Overall dimensions (length height width), mm Electric pump 340 210 185 Tank 210 150 112 Weight, kg: Electric pump 7 Tank 2 0902-14

Chemical cleaning system WB-5C 1 - tank for cleaning solution, 2 - pump, 3 - inlet connection, 4 - outlet connection, 5 - seal, 6 - tank cap. General description The chemical cleaning system consists of circulation pump with embedded stainless steel tank for preparation of cleaning solution, pipes and valves. Cleaning is carried out with oxalic (or citric) acid, which is supplied in the form of powder and dissolved in the tank before cleaning. When the pump is on the water mixes with cleaning solution and circulates through UV chamber. After cleaning the water is removed out of the chamber through water discharge tap mounted on the chamber. System type WB-5C Cleaning tank material Plastic armored with glass fiber PRO-GF30 Cleaning tank volume, l 5 Connection pipes DN 25 Cleaning agent Oxalic acid Electricity requirements 220 V, 50-60 Hz Power consumption, kw 0,72 Overall dimensions (length height width), mm 498 270 215 Weight, kg 9 0902-15

Hydraulic Parameters of OS plants Flow diagram for OS -A units (UV Doze = 300 J/m 2 ) 2000 1000 OS-1A OS-5A OS-18A OS-2A OS-7A OS-36A OS-4A OS-12A ow rate, 3 m / hr 100 Fl 10 5 40 50 60 70 80 90 UV transmission, % Head loss diagram for OS-A units 600 100 OS-1A OS-2A OS-4A OS-5A OS-7A OS-12A OS-18A OS-36A Head l oss, cm 10 2 5 10 100 1000 2000 Flow rate, m 3 /hr 0902-10