Agencourt AMPure XP. Xtra Performance Post-PCR clean UP



Similar documents
AxyPrep TM Mag PCR Clean-up Protocol

SOLID PHASE REVERSIBLE IMMOBILIZATION HIGH PERFORMANCE NUCLEIC ACID ISOLATION AND PURIFICATION

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

How To Get Rid Of Small Dna Fragments

FULLY AUTOMATED AND VALIDATED HIGH VOLUME DNA EXTRACTION USING CHEMAGEN MAGNETIC BEADS BASED KITS

FOR REFERENCE PURPOSES

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

Protocol v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION

The RNAi Consortium (TRC) Broad Institute

BR-10150B. Bringing power and flexibility down to size. BIOMEK NX LABORATORY AUTOMATION WORKSTATION

BacReady TM Multiplex PCR System

GenScript BloodReady TM Multiplex PCR System

Automated High Throughput Purification of BigDye TM Terminator Fluorescent DNA Sequencing Reactions Using Wizard MagneSil TM Paramagnetic Particles

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from μL of Plasma and Serum

Sequencing Guidelines Adapted from ABI BigDye Terminator v3.1 Cycle Sequencing Kit and Roswell Park Cancer Institute Core Laboratory website

Sanger Sequencing. Troubleshooting Guide. Failed sequence

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

UltraClean PCR Clean-Up Kit

TIANquick Mini Purification Kit

DNA Sequencing Setup and Troubleshooting

Welcome to Pacific Biosciences' Introduction to SMRTbell Template Preparation.

Amplicon Template Preparation and Sequencing

Automated Nucleic Acid Extraction WorkStation Faster, cleaner,

Software Getting Started Guide

Sanger Sequencing: Sample Preparation Guide

Single Nucleotide Polymorphisms (SNPs)

Genomic DNA Extraction Kit INSTRUCTION MANUAL

14/12/2012. HLA typing - problem #1. Applications for NGS. HLA typing - problem #1 HLA typing - problem #2

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

IMBB Genomic DNA purifica8on

Troubleshooting Sequencing Data

UltraClean Soil DNA Isolation Kit

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Difficult DNA Templates Sequencing. Primer Walking Service

1) Vector Preparation sg 1371 w/blp1 Ef1α puro t29 BFP (602 ng/ul)

MICB ABI PRISM 310 SEQUENCING GUIDE SEQUENCING OF PLASMID DNA

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products

ALPs (Automated Labware Positioners)

ZR DNA Sequencing Clean-up Kit

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Your Personal Pipetting Robot

Illumina TruSight HLA Sequencing Panel Automated on the Biomek FX P HLA SP Liquid Handler

SEQUENCING. From Sample to Sequence-Ready

Introduction. Preparation of Template DNA

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

Security, Audit, and e-signature Administrator Console v1.2.x

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

Automation in genomics High-throughput management of biological samples and nucleic acids. Valentina Gualdi Operational Scientist PGP

DNA Sequencing Troubleshooting Guide.

Institutional Partnership Program

Genetic Analysis. Phenotype analysis: biological-biochemical analysis. Genotype analysis: molecular and physical analysis

Multiplex your most important

Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated. Screening

Recommended Procedures for the Extraction of RNA. Jan Pedersen USDA, APHIS, VS, National Veterinary Services Laboratories, Ames, IA 50010

Click the Windows. Click the Office Trial icon to write letters or create a spreadsheet

MACHEREY-NAGEL NucleoSpin Robot-96 Extract Kit Genesis Freedom Genesis RSP Genesis RWS

Sanger Sequencing and Quality Assurance. Zbigniew Rudzki Department of Pathology University of Melbourne

Introduction Bioo Scientific

Fingerprint Enrollment Procedures

BabyWare Imperial PC Software

Inverse PCR & Cycle Sequencing of P Element Insertions for STS Generation

CUSTOM DNA SEQUENCING SERVICES

How is genome sequencing done?

DNA Sequencing Handbook

Agilent System Protocol Test Release Note

Application Guide... 2

Vector NTI Advance 11 Quick Start Guide

Dye-Blob message: Example: Generally, this is due to incomplete excess dye removal of the cycle sequence reaction.

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

Guide to using the Bio Rad CFX96 Real Time PCR Machine

DNA: A Person s Ultimate Fingerprint

USER GUIDE. Encore PART NOS and SP Rapid Library Systems

The Thermo Scientific KingFisher Family

Intended Use: The kit is designed to detect the 5 different mutations found in Asian population using seven different primers.

qstar mirna qpcr Detection System

Preparing Samples for Sequencing Genomic DNA

INSTALLATION GUIDE MC

Software Installation Instructions IK 5000 QUADRA-CHEK. Software Version 3.0.x

CyTOF2 Sample Acquisition: Super Sampler* (CyTOF software version )

Cluster Generation. Module 2: Overview

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

Mitos P-Pump. product datasheet

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

IX Support Tool Setting Manual

DNA SEQUENCING (using an ABI automated sequencer)

NEW FEATURE OVERVIEW SPRINGCM S APPROVAL WORKFLOW TOOL (AKA ROUTING AND APPROVAL WORKFLOW)

ab Hi-Fi cdna Synthesis Kit

Perceptive Connector for Infor Lawson AP Invoice Automation

USER MANUAL (PRO-CURO LITE, PRO & ENT) [SUPPLIED FOR VERSION 3]

DNA Sample preparation and Submission Guidelines

Aurora Forensic Sample Clean-up Protocol

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

PrepTip. Reverse Phase PrepTip User Guide

Bioanalyzer Applications for

Stellar Phoenix Exchange Server Backup

SERVICE REQUEST OF DNA SEQUENCING

Transcription:

Agencourt AMPure XP Xtra Performance Post-PCR clean UP

Applications o PCR o Genotyping, SNP detection o Fragment analysis o Sequencing (Sanger and Next generation) o Cloning o Primer walking

Agencourt AMPure XP: Xtra Performance Chemistry: SPRI based with speed beads Recovery: Double stranded and single stranded DNA with 70 90% of fragment sizes 150bp 10 kb Processing time: Faster than Traditional post PCR clean up methods Purification: Efficient removal of primers, primer dimers, dntps and salts. Stable PCR products post clean up: No PCR degradation at 4 C for 7 days Compatible with down stream applications PCR Genotyping ( SNP detection) Fragment analysis Sequencing (Sanger and Next generation (post shearing clean up) Cloning Fragment analysis Primer walking Automated and scalable: 96, 384 well formats (Biomek 3000, NX P, and FX P ) User friendly automated method o Quick start up menu o Deck set up walk through menu o Method recovery o LIMS compatible Shelf-life: 1 year

Agencourt AMPure XP

Agencourt AMPure vs. AMPure XP: Beads COOH COOH COOH COOH COOH COOH COOH Magnetite Encapsulation COOH COOH Non-styrene polymer surface

Fast and Pure PCR Products Bind Inc Bind settle EtOH settle Air Dry Elute Inc Elute Settle Total Agencourt AMPure 5 min 5 min 30 sec 10 min 2 min 5 min 27.5 min Agencourt AMPure XP 5min 2 min 30 sec 0 min 2 min 1 min 10.5 min

Agencourt AMPure XP vs. AMPure: Faster & Higher Throughput Final Transfer Plates Agencourt AMPure XP (min) Agencourt AMPure (min) XP % Faster Yes No 1 18 30 40% 2 23 34 32% 3 30 41 27% 4 37 47 21% 1 14 27 48% 2 19 32 41% 3 25 38 34% 4 31 44 30% 5 38 49 22% 6 45 55 18%

High Recovery 30 25 Agencourt AMPure XP QIAquick QuickStep Concentration (ng/ul) 20 15 10 5 0 200bp 800bp 10kb Template size (bp) Trade marks are property of their respective owners

Purification Versatility : ds & ss DNA 30.00 Concentration (ng/ul) 25.00 20.00 15.00 10.00 5.00 200 bp 800 bp 10 kb 0.00 ds DNA ss DNA Agencourt AMPure XP

Pure PCR Products: No Dimers --- No Salts M Agencourt AMPure XP QIAquick QuickStep ExoSAP-IT M 1 2 3 4 5 6 7 8 3.00 2.50 Agencourt AMPure XP QIAquick QuickStep ExoSAP-IT 2.00 OD260/230 1.50 1.00 0.50 Primer Dimers 0.00 No Primer Dimers 200bp 800bp 10kb Template size (bp) No Salts Carry Over Trade marks are property of their respective owners

Stable PCR Products M Agencourt AMPure XP QIAquick QuickStep ExoSAP-IT M M Agencourt AMPure XP QIAquick QuickStep ExoSAP-IT M 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 > 50% degradation Day 0 Day 7 at 4 C PCR Products Post PCR Clean up on 1.2% Agarose

Faster PCR Clean up Time to Process 96 Samples (min) 100 80 60 40 20 0 Agencourt AMPure XP QIAquick QuickStep ExoSAP-IT

Agencourt AMPure XP Offering Product Size* Product # Agencourt AMPure XP---5.0mL 139/278 A63880 Agencourt AMPure XP---60.0mL 1666/3333 A63881 Agencourt AMPure XP---450.0mL 12500/25000 A63882 Method Product # Software - Agencourt AMPure XP 96 MC - v3.x A79794 Software - Agencourt AMPure XP 384 MC - v3.x A79795 * Note: Ampure price per prep dependent on PCR reaction volume. Pricing assumed for 25(96) & and 10(384) ul PCRs.

User Friendly Interface

Agencourt AMPure XP GUI Quick Start tab Purpose: To provide a simple interface for users to quickly specify common runtime variables and confirm deck setup. Key Features: System Inputs - Number of plates - PCR volume System Outputs - Transfer option - Elution volume - Transfer volume Sample Tracking - User ID - Reagent Lots Display deck layout - Barcode Entry Automatic restoration of previous run values

Agencourt AMPure XP GUI Run Setup tab Purpose: To guide novice users through the run setup process. Key Features: Detailed instructions to guide users step by step through the setup process at their own pace. Positions specified in the instructions are highlighted in the deck display. Minimum fill volumes for each reagent reservoir are calculated and displayed (i.e. it takes more reagent to process 4 plates than 1). Completely optional; expert users do not have to go through setup guide to start a run Just Quick Start > Run.

Agencourt AMPure XP Method Recovery tab Purpose: To enable users to recover an aborted run. Key Features: The state of each plate (which steps have been performed, which have not) and the location of each plate is maintained throughout the run. If a method recovery file is found when the method starts up, the GUI will present the Method Recovery tab. The list view shows the current state of the highlighted plate. Users can click on any plate in the deck display to highlight it and see its state. Users can manipulate the state of each plate by checking/unchecking the box to the left of each step. Users can rearrange the location of plates in the deck display. Users can reset a plate, all plates, the deck or start over completely with the click of a button. Detailed instructions for this step are provided with the click of a button.

Agencourt AMPure XP Customize Procedure tab Purpose To make it easy for users to adjust run settings. It enables users that are not comfortable editing or creating Biomek methods to easily customize an Agencourt method to suit their specific needs. Key Features Every sensible protocol variable is exposed in a descriptive and readable format. Non-validated run settings are highlighted to caution against changes. Validated run settings can be restored with the click of a button. Custom run settings are saved and restored. Allows multiple users to run their own customized version of the method. Settings can be locked. Detailed instructions for this step are provided with the click of a button.

Automation Configuration NX P 96 Beckman Part # Qty Decription A31841 1 Biomek NXp Single Arm Multichannel Laboratory System A16170 1 Biomek Automation Controller XP and Monitor with Biomek System Software 719368 1 Biomek FX/NX 96-Channel 200 µl disposable tip pipetting head 719356 1 Biomek Disposable Tip Loader ALP The Biomek Disposable Tip Loader ALP for 96/P200 and 384/P30 disposable tips. Requires: 40 PSI clean dry air, 2.5 cfm. 719948 1 High-Density Twelve-Position 4x3 ALP For use on a FX/NX 719357 1 Standard Single-Position ALP for positioning of one standard 96 and/or 384 well microtiter plate. 719363 1 Biomek Disposable 96 ALP Tip Wash Station. NOTE: Requires Biomek Device Controller (P/N 719366) 719366 1 Biomek Device Controller Includes Biomek device controller module, CAN communications cable. A29216 1 Agencourt AMPure 96 Batch method A42033 1 Installation & validation, North America, 1-day A32782 3 Agencourt SPRIPlate 96R Super Magnet Plate