MS41-22Ex0-R/24VDC MS41-22Ex0-R/115VAC MS41-22Ex0-R/230VAC



Similar documents
Inductive sensor NI10-M18-Y1X-H1141

SELF-POWERED VOLTAGE DETECTING & PROTECTING RELAY

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive Proximity Sensors

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Chapter 9 Latches, Flip-Flops, and Timers

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Creating Relay Logic Diagrams

Intrinsically Safe Barrier Relays NY2 and 8501TO

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

System 8. ü ( System 8

Solid State Timers Type F

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Programming A PLC. Standard Instructions

Three-phase monitoring relay CM-PFE

Electrical Symbols and Line Diagrams

WD-AMX Water Detection Controllers

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

SMART SENSOR COLLECTION

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

13 SERIES. Electronic step relays A

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

40 Series - Miniature PCB/Plug-in relays A. Features

*.ppt 11/2/ :48 PM 1

Warrick Series DMS-470/570 Montoring Panels Installation and Operation Bulletin

SKR - industry relay

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Water Leak Detection System

Programming Logic controllers

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

PNOZsigma - Base units

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Contents. Document information

RY2 miniature industrial relays

Short information Parameters are programmed via front-side membrane keypad

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

So far we have investigated combinational logic for which the output of the logic devices/circuits depends only on the present state of the inputs.

Model: DC-A2IO Advanced HVAC Controller

Having read this workbook you should be able to: recognise the arrangement of NAND gates used to form an S-R flip-flop.

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D

Single Channel Loop Detector

PROGRAMMABLE LOGIC CONTROLLERS Unit code: A/601/1625 QCF level: 4 Credit value: 15

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

PLC Based Liquid Filling and Mixing

Speed Control Relays SX2

How To Read A Pipe From A Sensor

Technical Data. Dimensions

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

Thermistor motor protection

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Sanitary Type Electronic Flow Switches

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

LAUBE TECHNOLOGY DRY REED RELAYS

THE INPUT/OUTPUT SYSTEM. Key Points

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Safety automation solutions

Configuring Alarms & Relays in the Enhanced Transformer Advantage

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Electronic Flow Switches

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Safety technique. Emergency stop module BO 5988 safemaster

SAFETY MANUAL SIL Switch Amplifier

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Solenoid Valve Island Type 3965

TDA4605 CONTROL CIRCUIT FOR SWITCH MODE POWER SUPPLIES USING MOS TRANSISTORS

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

EC3-D72 Superheat & Digital Scroll Controller Technical Data

Digital Expansion Modules Specifications

Combi B Alarm box. Mounting instructions

TRILOGI 5.3 PLC Ladder Diagram Programmer and Simulator. A tutorial prepared for IE 575 by Dr. T.C. Chang. Use On-Line Help

38 Series - Relay interface modules A

Controller Automation, Model II+

3BASIC RELAY INSTRUCTIONS

Inductors in AC Circuits

mecotron Safety relay ESTOP-2 For emergency stop monitoring

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Oil and Coolant Circulating Heating System. Model - OCSM

E-STOP relays, safety gate monitors

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

E-STOP relays, safety gate monitors

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

11. FLOWCHART BASED DESIGN

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

How to read this guide

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

SECTION LOW VOLTAGE LIGHTING CONTROLS

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Transcription:

The MS41-22Ex0-R is a single channel device with four intrinsically safe inputs that can be used as a bistable relay, or as a programmable switching amplifier without bistable characteristics. As a bistable relay, the switching functions can be programmed to perform AND (identity) or OR (exclusive OR) functions (set / reset control). By leaving the inputs open or closed, the desired function may be selected. Please refer to the following pages for further information on logic functions. The input circuits can be configured for: - - Flip-Flop Control - Programmable Switching Amplifier - Exclusive OR Circuit - Lockout Circuit - Trigger Circuit - Sequence Control - Pump in - Pump out MS41-22Ex0-R/24VDC MS41-22Ex0-R/5VAC MS41-22Ex0-R/230VAC Connection Diagram

Type ID Number Power Supply Supply voltage Power consumption Galvanic isolation MS41-22Ex0-R/24VDC M5363700 Input Circuit Nominal operating characteristics (per DIN 19234) - Voltage 8 V - Current 4.5 ma Switching threshold 1.55 ma Hysteresis 0.2 ma 20-28 VDC, 10% ripple 3.6 W between input circuit, output circuit and supply voltage, test voltage 2.5 kvrms Bistable Switching Amplifier Intrinsically Safe MS41-22Ex0-R/...(24VDC/5VAC/230VAC) MS41-22Ex0-R/0-120VAC M5363400 98-126 VAC, 48-62 Hz 3.5 VA between input circuit, output circuit and supply voltage, test voltage 2.5 kvrms 8 V 4.5 ma 1.55 ma 0.2 ma MS41-22Ex0-R/230VAC M5363100 184-250 VAC, 48-62 Hz 3.5 VA between input circuit, output circuit and supply voltage, test voltage 2.5 kvrms 8 V 4.5 ma 1.55 ma 0.2 ma Intrinsic Safety Parameters See page K14 See page K14 See page K14 Output Circuit Contact material two SPDT relays AgCdO two SPDT relays AgCdO two SPDT relays AgCdO Switching voltage 250 VAC/60 VDC 250 VAC/60 VDC 250 VAC/60 VDC Switching current 4 A 4 A 4 A Switching capacity 1000 VA/60 W 1000 VA/60 W 1000 VA/60 W LED Indications - Output energized yellow yellow yellow Housing Style Diagram E (page A18) Diagram E (page A18) Diagram E (page A18) -Point and Logic Controllers

Exclusive OR Logic 14 Any time the two sensors have the same state: Either both sense or do not sense a target, the relay is energized. 13 Any time the two sensors have a different state: 12 One is sensing a target and the other is not, the relay is de-energized. 10 9 Switching Amplifier The MS41-22Ex0-R can be used as a single channel switching amplifier. Programming Diagram # Dry Contacts Input Inductive NAMUR Capacitive NAMUR Output Relay 1 Energized 2 Energized Diagram 1 Diagram 2 14 13 12 10 9 14 13 12 10 9

MS41-22Ex0-R... 1 Channel - Control Table 1 The truth tabel for the MS41-22Ex0-R as a - control is shown in Table 1. Typical applications for the - control are: - Forward-Reverse operation of a work piece carrier. - Detecting the leading edge of a large target to start () and further down a line stop () work. This is especially useful for a larger target that may be warped and drift in and out of the sensing range. Input Input Output Relay (power up only) (power up only) Target Energized Target Target Target Energized (per diagrams 3 & 5) (per diagrams 4 & 6) No change from previous state Diagram 3 Inductive Sensor Input Diagram 4 Inductive Sensor Input -Point and Logic Controllers Diagram 5 Capacitive Sensor Input Diagram 6 Capacitive Sensor Input

Sequence Control for Pump-in Filling a Tank The MS41-22Ex0-R will start a pump or open a fill valve when the liquid drops below the low level sensor and remains on until the high level sensor is reached. The relay then de-energizes and stays off until the low level is reached. The pump or valve does not cycle constantly as would be the case if only one sensor were used. Sequence control for Pump-out Draining a Tank The MS41-22Ex0-R will start a pump when the liquid reaches the high level sensor and remains on until the low level sensor is reached. The relay then de-energizes and stays off until the high level is reached. The pump or valve does not cycle constantly as would be the case if only one sensor were used.

MS41-22Ex0-R/... Lockout Control The MS41-22Ex0-R can be used to control the filling of tanks or bins and then automatically lockout refilling. The lockout remains effective even if the power is recycled or the level in the vessel drops. The N.C. push-button contacts on terminals 9-10 must be opened when the level has dropped below the sensor to the lockout. The unit is also used where contamination of the product in the vessel is possible and the consequences are major. The contamination may come from dissimilar products or even the same product where age must be considered, such as dairy products. Even with the best sensors to detect low level, product or residue is left in the vessel or outlet. Human control and inspection are needed. TURCK has a complete line of Intrinsically Safe Capacitive NAMUR Sensors and a selection of throughthe-wall sensor wells approved for food grade applications. Trigger Control -Point and Logic Controllers The MS41-22Ex0-R can be used with two inputs to function as a trigger circuit. The ladder logic equivalent is shown. The advantage of using the MS41-22Ex0-R is that it is all in one device. It replaces 2 channels of Intrinsically Safe switching amplifiers, or multiple barriers and one control relay. The ready sensor detects a large target such as a container, a work piece carrier or clamp. The trigger sensor is looking for a leading edge or pin point index. When the trigger target is detected and the ready target is present, the output relays of the MS41-22Ex0-R are energized. They remain energized until the ready target moves out of range, even if the trigger is Diagram 7 Diagram 8 Trigger Trigger Capacitive Sensors Ready Inductive Sensors Ready 12