Conlit fire protection



Similar documents
Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

ROCK WOOL Preformed Pipe Section

Fire Barrier Duct Wrap 15A

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus

Services Enclosures and Protected Shafts - Maintaining Compartmentation

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Rockwool Flexi Insulation Application Guide

Rockwool Cladding Roll

ProRox Slabs (formerly known as RW slabs)

Hanson Building Products. precast basement solutions

Puddle Flange. FRANK Puddle Flange

Excerpts from the Canadian National Building Code (NBC)

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

General Allowances for Insulation & Cladding

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Mold Preventing I nterior System

Multi-layer Insulation Blanket for Roofs

TARIFF CODE and updates standard

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Welded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Tremco Fire Protection Systems Group Technical Bulletin

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

Fiberglas, Exterior Wall Thermal Insulation

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Detailing of Reinforcment in Concrete Structures

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster @@@

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Built to Last. Built for Beauty. Good. Solid. Logix. TM

BSF and BCC beam connections

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Chapter 2 Basis of design and materials

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

SIKA AT WORK THE KAENG KRACHAN ELEPHANT HOUSE AT ZURICH ZOO

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

H-Stud Area Separation Wall System

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

STENCA PIPE. High quality pipe insulation.

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Structural fire design Eurocode Timber structures

How To Repair A Boat Landing Deck With A Boat Bed

MERO Floor Systems - CleanRoom

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

sound reduction systems for commercial, educational and industrial environments

Marine & Offshore Insulation. - products and constructions November 2009

Composite Panel Firewall Systems

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

HOW TO INSULATE A CRAWLSPACE

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

Steel-framed Walls. Insulation

4 Installation Requirements

The WANZ Guide to Window Installation

Edition: Export Published: 11/2007. Product catalogue. Lapinus

European Technical Assessment ETA-15/0028 of 23/02/2015

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

SECTION PIPE HANGERS AND SUPPORTS

Product Information Sheet

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

BETONYP building boards. The modern way of living.

Light-Weight Panels. High quality panels.

TABLE OF CONTENT

PANELIZED HOME INSTALLATION GUIDELINE

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

39HQ Airovision Air Handling Units

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

DE Frame with C Series Sidelight

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Transcription:

Conlit fire protection A strong cut pipe section for industrial and building application Roxul Rockpipe C11 Key Application Qualifiers: - Resistant to temperatures up to 550 0 C - Excellent thermal and acoustic properties - imensionally stable - Non-corrosive and highly water-repellent - Cost-effective - Non-combustible GENERAL CHARACTERISTICS OF ROXUL ROCKWOOL PROUCTS: NON-COMUSTILE. WATER-REPELLENT. VERMIN- AN ROT-PROOF. ASESTOS-, CFC-, AN HCFC-FREE PROUCT AN PROCESS. CHEMICALLY INERT. EASY TO HANLE AN CUT. MAINTENANCE-FREE. Conlit-150 P Pipe Section

INTROUCTION Lapinus Conlit fire protection products are manufactured from mineral wool and are specially engineered to combine maximum fire protection with the least possible weight and thickness. This makes them ideal for those situations where weight reduction is an important factor, for example for ease of handling, in refurbishment and high rise construction work. oth the construction of Conlit systems and their ease of fixing make them highly competitive with other systems of fire protection. PROUCT ESCRIPTION Specially impregnated, self-supporting rigid mineral wool slab. Conlit-150 P Pipe Section Specially impregnated, pre-formed insulation units. Conlit Glue Conlit Glue is non-toxic with a ph value of approx. 11. It is provided in 20 kg drums and should always be stirred before use. Use approximately 0.5 kg per m 2 of slab or pipe section. Application 1. Structural Steel Lapinus and Conlit-150 P Pipe Sections can be used to provide 1 /2, 1, 1 1 /2, 2, 3, and 4 hour fire protection to flat and circular loadbearing steel beams and columns, assessed at 550 C failure criteria. 2. ucts Lapinus and Conlit-150 P Pipe Sections can be used to provide 1 /2, 1,1 1 /2 and 2 hour fire protection to rectangular and circular ventilation and smoke extract steel ductwork. The fire protection provided is in accordance with S 476 Part 24, duct type. The Conlit uctwork system protects horizontal and vertical ductwork against both fire break out and fire break in. Kitchen extract ducts, which are subject to separate S 476 Part 24 requirements, are additionally covered for 1 /2 and 1 hour protection periods. 3. Wall - Floor Penetrations of Pipes Lapinus Conlit-150 P Pipe Sections can be used to provide up to 90 minutes fire protection to water pipework penetrations in fire resistant wall and floor constructions. The pipes can either be of non combustible steel and copper or of combustible plastic material. 4. Sprinkler pipes Lapinus Conlit-150 P Pipe Section can be used to provide up to 90 minutes fire protection to fire fighting pipes. 5. Concrete floors Lapinus can be used to increase the fire resistance of concrete floors. The thickness of a concrete floor, based on a required fire resistance, can be reduced by 25 mm for every 10 mm of Conlit-P Slabs 756 used. Advantages Single layer, enabling verification of system integrity Fast installation time, easy to handle imensionally stable Space efficient, no maintenance, cost effective Moisture repellent, CFC and HCFC free Standards The Conlit uctwork System has been tested by the Loss Prevention Council in accordance with S 476 Part 24. Additional tests have been carried out in accordance with IN 4102 Part 6. The Conlit Structural Steelwork System has been tested according to S 476 Part 8 for the fire protection of loadbearing steel beams and columns, for up to 4 hours protection. The Conlit Sprinkler System has been assessed by the Technical University raunschweig in Germany for the fire protection of sprinkler pipes, for 1 1 /2 hour fire protection. The Conlit Concrete Floor System has been tested by the Norwegian Fire Technical Laboratory, SINTEF and has also been assessed by the Technical University raunschweig in Germany for the fire protection of concrete floor constructions. The Conlit Pipe Penetration System has been assessed by the Technical University raunschweig in Germany for the fire protection of wall and floor penetrations, for up to 90 minutes protection. imensions Length: 1800 mm Width: 1200 mm. Thicknesses: 15, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 and 110 mm. Thicknesses below 25 mm are available to special order. Thickness 15 mm only availabe with width 900 mm. Slabs can be supplied with reinforced aluminium foil facing. Conlit-150 P Pipe Sections Length: 1000 mm. Nominal pipe O/: 17-610 mm. Thickness: 25 up to 120 mm. Thickness availability dependent upon Conlit-150 bore.

STRUCTURAL STEEL Fixing options Conlit-P Slabs can be fitted to provide boxed or profiled fire protection for 1, 2, 3 or 4 sided exposed steel conditions. Conlit-P Slabs can be fixed using two methods: - Noggings, Conlit Glue and nails - Welded steel pins and glued butt corner joints FIXING CONLIT-P SLAS TO NOGGINGS Universal beams and columns Cut noggings 100 mm wide from waste Conlit-P Slab. Glue FIXING CONLIT-P SLAS WITH STU WELE PINS Universal beams and columns Stud welded pins provide the installer with a simple tested alternative to noggings. Minimum 2.5 mm diameter corrosion resistant steel pins are gun welded to the steel structure using capacitor discharge or drawn arc solid state power systems. Fix stud welded pins as indicated below. noggings to steel flanges with Conlit Glue ensuring the steel surface is free from dust and loose particles. Noggings should be at least 25 mm thick and never less than the cover slab thickness. For web depths greater than 500 mm, full depth noggings should be used. Fix noggings as indicated below. Impale vertical Conlit-P Slabs onto pins, and fit 38 mm diameter spring steel non return washers to secure slabs in situ. Apply Conlit Glue to all slab-to-slab joints. Offer up soffit slabs and/or top slabs and nail through glued corner joints at 450 mm maximum centres. Apply Conlit Glue to face of the noggings, then without delay apply vertical slabs and secure by nails long enough to completely pierce noggings. Glue edge joints. Repeat this sequence for the next section of work, first applying glue to all slab-to-slab joints, then crop off excess pin lengths if required. Apply bottom flange Conlit-P Slab. Glue at slab joints and nail fix at 450 mm centres. Repeat process with Conlit Glue between adjacent Conlit-P Slab edges. Apply bottom flange slab. Glue at slab joints and nail fix at 450 mm centres. Repeat process with Conlit Glue between adjacent slab edges.

FIXING FLAT UCTS Conlit-P Slabs 756 are cut to size using either hand saws or machine tools. A 10 mm tolerance is made for cutting and other tolerances. FIXING CONLIT-150 P PIPE SECTIONS Universal beams and columns Conlit-150 P Pipe Sections should be wrapped around the circular beam of column. The pipe sections should be temporarily secured with 3 steel binding wires or steel bands at 200 mm centres per pipe section. All joints should be glued with Conlit Glue, including the internal pipe section joints. 1. Circular structural steel 2. Conlit-150 P Pipe Section 3. Joints glued with Conlit Glue 4. Steel bands at 400 mm centres 5. Steel cladding The pipe sections may be clad with a steel or aluminium cladding. Cladding should not be fastened directly to the circular section. Welded steel pins Conlit-P Slabs 756 are secured to the duct using 2,5 mm dia welded steel pins and 38 mm spring steel washers. Welded pins are generally spaced at 350 mm maximum centres along the length of the duct and at 500 mm maximum centres across the width/height of the duct. UCTS FLAT AN CIRCULAR UCTS Summary of Fire resistance performance Fire uct Conlit uct joint resistance type thickness and hanger (hours) [mm] options 1/2 Vertical 25 C Horizontal 25 C Kitchen extract 40 -C 1 Vertical 30 C Horizontal 40 -C Kitchen extract 90 A--C 1 1 /2 Vertical 50 -C Horizontal 70 A--C 2 Vertical 70 A--C Horizontal 90 A--C Hanger centres: 1500 mm (max.) rop rods: M10 steel (min.) Tensile stress drop rods: 6 N/mm 2 earers: 30 x 30 x 3 mm steel angle (min.) Installation sequence The installation sequence of the Conlit-P Slabs 756 may vary depending on whether the Conlit-P Slabs 756 are located inside or outside the hanger system. Insulation outside hanger system I, II, III Insulation inside hanger system III, II, I Insulation may be installed either inside or outside the hanger system. Joint options A C

Wall penetrations Support to the duct sides is required at all penetrations for stability purposes. This support can be provided by: - Locating the duct joint at the penetration mid point. - Rivetting a 30 x 30 x 2 mm mild steel angle frame to the duct at the penetration mid point. Steel rivets should be FIXING CIRCULAR UCTS Conlit-150 P Pipe Sections should be wrapped around the duct. The pipe sections to be glued with Conlit Glue at joints, hinge and longitudinal split. Steel bands or wires must be fitted circumferentially to the system at 300 mm nominal centres to hold the joints tightly closed while the glue sets. used at 300 mm maximum centres. 1. uct 2. Conlit-150 P Pipe Section 3. Joints glued with Conlit Glue 4. Steel band 30x3 mm 5. M10 steel drop Elbows Elbows can be protected by cutting fan shapes pieces. All joints are glued. PIPE PENETRATIONS Wall and floor pipe penetrations Conlit-150 P Pipe Sections can be used to provide up to 90 minutes fire protection to wall and floor penetrations for water pipework. Non combustible pipes Wall and floor penetrations of non combustible pipework, except aluminium and fibre cement, can be sealed with Conlit- 150 P Pipe Sections. Combustible pipes The penetration should be insulated the same way as for non combustible pipes. Three sided application This method for three sided applications, may also be used for two sided applications. Additionally wall and floor penetrations with combustible pipes and pipes of aluminium or fibre cement need special requirements. Wall penetrations The pipe should be insulated with Conlit-150 P Pipe Section over a distance of 4 m at the penetration, with a minimum of 1 m on one side of the penetration. 1. Combustible pipe 2. Conlit-150 P Pipe Section (detail A) 3. inding wire or steel band (3 per Pipe Section)

Floor penetrations The pipes should be insulated over the total length at every floor with Conlit-150 P Pipe Sections. If aluminium or fibre cement pipes are used, the pipe should only be insulated at every second floor. Required insulation thickness for wall and floor penetrations: 30 mm. Conlit-150 P Pipe Sections are generally secured with 3 steel binding wires or steel bands per pipe section. SPRINKLER PIPES Insulating sprinkler pipes with Conlit-150 P Pipe Sections can provide fire protection up to 1 1 /2 hour. The required insulation thickness depends on the thickness of the pipe. 1. Concrete floor 2. 3. M6 screw with steel dowel or 6 mm steel fixing with 38 mm diameter non-return washers 4. Conlit Glue to all slab to slab joints Required Conlit-150 P thickness for 90 minutes fire resistance Pipe thickness [mm] 2.0-2.5 2.5-3.5 3.5-4.5 4.5-5.0 5 60 mm 50 mm 40 mm 30 mm 25 mm ESIGN PARAMETERS Protection of structural steelwork The extent of added protection will depend on the size, mass, degree of exposure and function of the element. Any element to be protected can be described by a Section Factor Hp/A (m -1 ) This factor is obtained by dividing the perimeter of the element exposed to fire (Hp). in metres, by the cross sectional area of the steel element (A) in square metres. Hp is determined as shown below. A is generally taken from section tables. 1. Concrete floor 2. Sprinkler pipe 3. Conlit-150 P Pipe Section, all joints should be glued with Conlit Glue 4. Steel band or steel wire at 400 mm centres 5. Steel drop rods M10. Tensile stress 6 N/mm 2. TALE: OX AN SOLI PROTECTION STEEL SECTION Universal beams, universal columns and joists (plain and castellated) Structural and rolled tees 2 OX and SOLI protection d Partially exposed +2d 2 sides + CONCRETE FLOORS Insulating the soffit of a concrete floor with Conlit-P Slabs 756 can decrease the thickness of a concrete floor, based on a required fire resistance. 25 mm concrete can be replaced by Angles 2 2 Flange to soffit Flange to soffit Toe of web to soffit Toe of flange to soffit 10 mm Conlit-P Slab. Conlit-P with a thickness of 25 mm can Channels replace 65 mm concrete. 2 Web to soffit 2+ Flange to soffit Hollow sections, square or rectangular Hollow sections, circular 2 π π determination method for profiled protection available on request

etermining protection thickness Circular Structural Steel eams and Colums Thickness [mm] Structural Steel eams Thickness [mm] Structural Steel Colums Thickness [mm] Conlit-150 P Pipe Sections SECTION FACTOR /A [m -1 ] 260 25 25 50 65 255 25 25 50 65 250 25 25 50 65 245 25 25 50 65 240 25 25 40 65 235 25 25 40 65 230 25 25 40 65 225 25 25 40 65 220 25 25 40 65 215 25 25 40 65 210 25 25 40 65 205 25 25 40 65 200 25 25 40 65 195 25 25 40 65 190 25 25 40 65 185 25 25 40 65 180 25 25 40 65 175 25 25 40 50 170 25 25 40 50 165 25 25 40 50 80 160 25 25 40 50 80 155 25 25 40 50 80 150 25 25 40 50 75 145 25 25 40 50 75 140 25 25 40 50 75 135 25 25 40 50 75 130 25 25 40 50 75 125 25 25 40 50 75 120 25 25 40 40 65 115 25 25 40 40 65 110 25 25 40 40 65 105 25 25 25 40 65 100 25 25 25 40 65 80 95 25 25 25 40 65 80 90 25 25 25 40 65 75 85 25 25 25 40 65 75 80 25 25 25 40 50 75 75 25 25 25 40 50 65 70 25 25 25 40 50 65 65 25 25 25 40 50 65 60 25 25 25 25 40 65 55 25 25 25 25 40 65 50 25 25 25 25 40 50 45 25 25 25 25 40 50 40 25 25 25 25 40 40 35 25 25 25 25 40 40 30 25 25 25 25 40 40 25 25 25 25 25 40 40 20 25 25 25 25 40 40 15 25 25 25 25 40 40 SECTION FACTOR /A [m -1 ] 260 15 15 25 45 90 255 15 15 25 45 90 250 15 15 25 45 90 245 15 15 25 45 90 240 15 15 25 45 90 235 15 15 25 45 90 230 15 15 25 45 90 225 15 15 25 45 90 220 15 15 25 45 90 215 15 15 25 40 80 210 15 15 20 40 80 205 15 15 20 40 80 200 15 15 20 40 80 195 15 15 20 40 80 190 15 15 20 40 80 185 15 15 20 40 80 110 180 15 15 20 40 80 110 175 15 15 20 40 80 110 170 15 15 20 40 80 110 165 15 15 20 35 70 110 160 15 15 20 35 70 110 155 15 15 20 35 70 100 150 15 15 20 35 70 100 145 15 15 20 35 70 100 140 15 15 20 35 70 100 135 15 15 20 35 70 100 130 15 15 20 35 60 90 125 15 15 15 30 60 90 120 15 15 15 30 60 90 115 15 15 15 30 60 90 110 15 15 15 30 60 90 105 15 15 15 30 60 80 100 15 15 15 30 60 80 95 15 15 15 25 50 80 90 15 15 15 25 50 80 85 15 15 15 25 50 70 80 15 15 15 25 45 70 75 15 15 15 25 45 70 70 15 15 15 20 40 60 65 15 15 15 20 40 60 60 15 15 15 20 35 60 55 15 15 15 20 35 50 50 15 15 15 20 35 50 45 15 15 15 15 30 45 40 15 15 15 15 30 40 35 15 15 15 15 30 35 30 15 15 15 15 30 30 25 15 15 15 15 30 30 20 15 15 15 15 30 30 15 15 15 15 15 30 30 SECTION FACTOR /A [m -1 ] 260 15 20 35 60 110 255 15 20 35 60 110 250 15 20 35 60 110 245 15 20 35 60 110 240 15 20 35 60 110 235 15 20 35 60 110 230 15 20 35 60 110 225 15 20 35 60 110 220 15 15 35 60 110 215 15 15 35 60 110 210 15 15 35 60 100 205 15 15 30 60 100 200 15 15 30 60 100 195 15 15 30 60 100 190 15 15 30 60 100 185 15 15 30 50 100 180 15 15 30 50 100 175 15 15 30 50 90 170 15 15 30 50 90 165 15 15 30 50 90 160 15 15 30 50 90 155 15 15 30 50 90 150 15 15 30 45 90 145 15 15 25 45 90 140 15 15 25 45 80 135 15 15 25 45 80 130 15 15 25 45 80 125 15 15 25 40 80 110 120 15 15 25 40 80 100 115 15 15 25 40 70 100 110 15 15 25 40 70 100 105 15 15 25 40 70 100 100 15 15 20 35 70 100 95 15 15 20 35 70 90 90 15 15 20 35 60 90 85 15 15 20 35 60 90 80 15 15 20 30 60 80 75 15 15 20 30 60 80 70 15 15 20 30 50 80 65 15 15 15 30 50 70 60 15 15 15 25 45 70 55 15 15 15 25 45 70 50 15 15 15 25 40 60 45 15 15 15 20 40 60 40 15 15 15 20 35 50 35 15 15 15 20 30 45 30 15 15 15 15 30 40 25 15 15 15 15 30 35 20 15 15 15 15 30 30 15 15 15 15 15 30 30 1/2 1 1 1 /2 2 3 4 1/2 1 1 1 /2 2 3 4 1/2 1 1 1 /2 2 3 4 FIRE RESISTANCE PERIO [hours] FIRE RESISTANCE PERIO [hours] FIRE RESISTANCE PERIO [hours] etermining protection thickness 1. As stated previously, an early decision is required on wether profiled or boxed protection is to be employed. 2. etermine /A factor Calculate the perimeter of the element exposed to fire ( ) in metres. Take the cross sectional area of the steel member (A) from section tables in square metres. 3. Establish the period of fire protection required. 4. Use the tables to determine the thickness of appropriate material to be used. Examples Universal column A = 66.4 cm 2 = 203.9 mm Fire protection: 3 hours = 206.2 mm ox protection 4 sided exposure = 2 + 2 = 2 * 203.9 + 2 * 206.2 = 820.2 mm = 0.820 m /A = 0.82 / 0.00664 = 123.5 m -1 Required insulation thickness: : 80 mm

KRINGLOOP Roxul Compatibility Rockpipe C11 Lapinus mineral wool is compatible with all materials with A strong cut pipe section for which industrial it is likely and to building come into application contact in normal building and industrial applications. Handling and storage Lapinus Industrial Conlit products are light and easy to cut to any shape with a sharp knife. For long-term protection they should be stored indoors or under a waterproof covering. iological Technical services COMMON APPLICATION Lapinus Conlit products offer no sustenance to vermin and The usiness Centre Industry, staffed by insulation Roxul Rockpipe is specially manufactured to meet the specification requirements do of industrial not encourage and building the growth application. of fungi, Our state-of-the-art moulds or bacteria. manufacturing process experts, is always ready to give help and advice on fire protection insulation and other situations concerned with the use gives the flexibility to produce the blocks with random fibre orientation that provide excellent thermal conductivity and compression-resistance properties. The advanced Environment CA/CAM technology, exclusive to the manufacture of our Roxul Rockpipe of Lapinus C11, Conlit products. ensures the following remarkable characteristics: No CFCs or HCFCs are used in the manufacture of Lapinus materials. 1. Our unique Lapinus lock system materials ensures do not there contain are no thermal any asbestos. bridges occurring in the insulation, thus avoiding heat loss in the process pipes. 2. Exact dimensioning which is meeting or exceeding, in most cases, all required standards and specifications. 3. Accurate nesting, resulting in exact fitting every time. 4. Smooth outer surface for a jacketed finish that ensures professional appearance. PACKAGING & STORAGE Smaller diameter pipes are packed in cartons 1020 x 410 x 410. igger diameter pipes are shrink-wrapped in branded polyethylene sheets. Products should be stored indoors or under a waterproof covering. IMENSIONS Length (mm) 1000 Pipe O & Insulation Thickness (mm) Suits S1387, S2871, ASTM C585 Nominal ensity (kg/m 3 ) 100 125 FOR OTHER SIZES, PLEASE CONTACT OUR CUSTOMER SERVICE REPRESENTATIVES. TECHNICAL PARAMETERS Maximum Service Temperature 550 0 C Thermal Conductivity 50 100 150 200 250 300 350 W/MK ASTM C335 / 0.038 0.048 0.055 0.062 0.070 0.083 0.095 S874 Fire Performance Non-combustible S476 Part 4 Chemical Chemically inert. Aqueous extract of the sections is neutral or slightly ASTM C 795 alkaline. It meets the requirements for use over stainless steel in The information included in this guideaccordance relates to thewith manufactured ASTM C 795products and product performance at the date of publication. As new technology develops, Chloride technical Content details as published are 6mg/kg subject to change without notice. Lapinus can assume no liability for misprints. Where ASTM Lapinus C 871has no control over installation design and construction, or conditions of application, Lapinus does not warrant performance or results of any installation employing Moisture Resistance Absorb less than 0.02 Vol % ASTM C1154 / C1104M their products. Refer also to the General Trading Terms. Water Absorption Less than 1% S2972 : 75 Suitability for Use Roxul Rockpipe C11 complies with the requirements of S 3958: Part 4 onded preformed mineral wool pipe sections and can be used to satisfy S 5422 Thermal insulating materials on pipes, ductwork and equipment. It also conforms to ASTM C 547 Type II, Standard Specification for Mineral Fibre Pipe Insulation. Roxul Rockpipe C11 has excellent properties for thermal insulation, fire protection and sound attenuation of pipework in industrial applications, such as chemical plants, petrochemical plants and power stations S 3958 Part 4 S 5422 ASTM C 547 Type II THE INFORMATION CONTAINE IN THIS ATA SHEET IS ELIEVE TO E CORRECT AT THE ATE OF PULICATION. ROXUL ASIA SN H OES NOT ACCEPT RESPONSIILITY FOR THE CONSEQUENCES OF USING ROXUL ROCKPIPE C11 IN APPLICATIONS IFFERENT FROM THOSE ESCRIE AOVE. ROXUL ASIA SN H IS A SUSIIARY OF THE ROCKWOOL INTERNATIONAL GROUP, THE LEAING AN LARGEST MANUFACTURER OF STONE WOOL PROUCTS IN THE WORL. PLEASE VISIT THE WESITE OF ROCKWOOL INTERNATIONAL A/S WWW.ROCKWOOL.COM TO HAVE AN OVERVIEW OF OUR GLOAL REPRESENTATION, PROUCTS, AN SERVICES. PAPIER KARTON 0800.2.5/EN Printed on 100% recycled paper. Head Office / Factory ROXUL ASIA SN H (495634-V) 175 A &, Kawasan Perindustrian Air Keroh Jalan Lingkungan Usaha 75450 Melaka, Malaysia. Phone : + 60.6.233.2010 Fax : + 60.6.233.2012 Email : info@roxul.com.my Webpage : www.roxul.com.my omestic / Export Sales Office ROXUL ASIA SN H (495634-V) 3A-12, lk, Kelana Square 17, Jalan SS7/26, Taman Kelana Indah Kelana Jaya, 47301 Petaling Jaya, Selangor. Phone : + 60.3.7880.0093 Fax : + 60.3.7880.2093 Email : info@roxul.com.my Webpage : www.roxul.com.my Singapore Representative Office 3 International usiness Park Unit No. 03-22, Nordic European Centre Singapore 609927 Phone : + 65.6890.6238 Fax : + 65.6890.6237 Email : info@roxul.com.my Rockwool Lapinus.V., Export ivision, P.O ox 1160, 6040 K Roermond, The Netherlands. Tel: (31) 475 35 34 75. Fax: (31) 475 35 36 40.