Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS



Similar documents
Fault Finder. A Service Engineers. for Warm Air Heating. Publication No. ZZ April 2015

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Combi 24 HE. User s Guide and Important Warranty Information

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

Combi Eco Elite Range. User s Guide and Important Warranty Information

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

Combi 30 HE. User s Guide and Important Warranty Information

User's Instructions. Alpha HE CB25/33 and HE SY25

For installation guide see reverse of book

Baxi Combi 80e & 105e

Operating instructions

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

User Guide. Promax System Condensing System Boiler

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

User Guide. Main Heat Condensing Central Heating Boiler

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

User Guide. Titanium Combi Condensing Combination Boiler

MODELS BR517R & BR517S (G.C & ) & ULTIMATE TURBOCHIM* & SUPERFLAME RF* Rear & Side Fan Flued Inset Gas Fires

San josé OWNER S MANUAL

Response: The combi boiler. Response: The fit anywhere combi

Look after your boiler so it can look after you

Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service

Contact Details. Please note that some of the contact details on this PDF document may not be current.

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

Troubleshoot resources for homeowner

orlando OWNER S MANUAL

Operating instructions

Energy Saving Fact Sheet Boilers

Operating instructions

Installation & User Instructions

AIR CONDITIONER WALL CONTROLLER

User Manual: C Long Point Houston, TX Facebook.com/CoolAZone Twitter.com/CoolAZone

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB

Vaillant s plain English guide to. simple, concise and precise

Please read and keep these instructions. Run water through your machine before first use

Operator: Save these instructions for future use!

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

A boiler breakdown can really be costly

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature


Gas Instantaneous Water Heater

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

Drayton Digistat +2RF

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

HeatSource HS1800 Heater

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Having a gas appliance installed or serviced? Doing home improvements?

Getting the best from your urn

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

GREENSTAR HEATSLAVE 12/18, 18/25, 25/32

cairn HMO Tenant Information Property Address: Letting: Maintenance:

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Installation Instructions

Advice for water, electricity, oil and gas consumers during severe weather.

The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget.

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

E-gas Instant Gas Water Heaters

Protect your pipes. Keep the water cycle running smoothly and be prepared in winter. Heat, insulate and protect your home.

Gas Condensing Boilers

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

Instruction manual for Firstline FCS12000CH

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

Protect your pipes. Keep the water cycle running smoothly and be prepared in winter. Heat, insulate and protect your home.

Your safety and the safety of others are very important.

HEATER, AIR CONDITIONING AND VENTILATION

Key energy-efficient features of your new home

HSQ. Heuston South Quarter Community Heating System User Guide

OTF Oil Fired Pool Heater

Protect your pipes. Be prepared this winter heat, insulate and protect your home

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

GAS/ELECTRIC REFRIGERATOR

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

PLP - TERMS AND CONDITIONS

User Operating Instructions Horstmann 425 Coronet Electro-mechanical Timeswitch

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Drayton Digistat +2RF/+3RF

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Frequently asked Questions about Drinking Water Supply.

How to choose a heat pump and use it wisely

Transcription:

sustainable solutions under one roof HEATING HOT WATER VENTILATION Hi-Spec Warm Air Heaters Publication No. ZZ 0782-11 June 2012 with System E-T & Basic Control USERS INSTRUCTIONS J25 - G.C. No. 42-416-99 J32 - G.C. No. 42-416-99 J32R - G.C. No. 42-416-99 J40 - G.C. No. 42-416-99 M31 - G.C. No. 42-416-99 These instructions are to be left with the User or adjacent to the Gas Meter www.johnsonandstarley.co.uk

CONTENTS The Benchmark Scheme 2 1 General Description 3 2 Starting and Stopping your Heater 4 3 Temperature Controls 5 4 Time Controls 5 5 Maintenance & Service 6 6 Trouble Shooting 7 7 Emergency Power Restrictions 7 8 Important Gas safety Information 7 The Benchmark Scheme Johnson & Starley Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales). All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist. This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. The Benchmark Checklist will be required in the event of any warranty work and as supporting documentation relating to home improvements in the otional documents section of the Home Improvement pack. In the interest of continuous development Johnson and Starley reserve the right to change specification without prior notice. Johnson and Starley prides itself on it s ability to supply spare parts quickly and efficiently. www.johnsonandstarley.co.uk 2

1. GENERAL INFORMATION IT IS A STATUTORY REQUIREMENT THAT ALL GAS APPLIANCES MUST BE INSTALLED BY COMPETENT PERSONS, (i.e. GAS SAFE REGISTERED INSTALLERS. GAS SAFE MEMBERSHIP ENQUIRIES - TEL: 0800 408 5500) IN ACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS (CURRENT EDITION). FAILURE TO COMPLY WITH THESE REGULATIONS MAY LEAD TO PROSECUTION. 1.1 IDENTIFICATION OF YOUR HEATER TYPE 1.1.1 Your heater will either be a System E-T, or Non E-T model. 1.1.2 System E-T model heaters are clearly identifi ed on the front of the appliance and are controlled by a Thermista-stat, whilst Non E-T models are controlled by a room thermostat. 1.2 WHAT IS SYSTEM E-T? 1.2.1 System E-T is a control that is in built into the warm air system, and which continuously adjusts the heaters operation to maintain the comfort level that you have selected. It provides a continuous supply of warm air, at just the right amount, to keep the selected temperature at a very precise level. 1.2.2 By setting the Thermista-stat to the temperature (comfort level) you require, it constantly measures the actual room temperature and compares it with the required temperature, and tells the heater how much warm air to supply in order to maintain the comfort level you have selected. When the comfort level is reached, the burner will cycle on and off, whilst the fan operates at a varying speed to maintain the comfort level. 1.2.3 The Thermista-stat is usually situated in the living room where it provides very accurate comfort level control. Since the Thermista-stat controls the heater, it also controls the warm air delivery to other rooms. The warm air system should be balanced to deliver the correct proportion of warm air to each room, and is usually carried out during installation. Adjustments can be made to individual registers (air outlets). By increasing the air fl ow, the temperature is increased, and conversely, for reduction in air fl ow the temperature is decreased. 1.2.4 Economy: If you wish to economise by cutting off heat to an unused room, simply close the register to that room. System E-T will automatically adjust the operation of the heater - and save gas. 1.2.5 Quick warm up: System E-T warms houses much quicker than radiator systems, however, if you turn on the warm air to a room when the rest of the house is already warm and the system is operating at less than full output, that room will warm up more slowly. 1.3 NON E-T MODELS 1.3.1 Non E-T model heaters operate under control of a room Thermostat. When the temperature falls below that set at the Thermostat, the main burner will ignite followed by the fan switching on. There will be a short delay from the burner ignition to the fan operation. 1.3.2 When the temperature reaches that set at the Thermostat, the main burner will extinguish followed by the fan switching off after the useful heat from the heater has been dissipated. Again there will be a short delay between the main burner extinguishing and the fan switching off. Sales/Spares 01604 707012 Replacement Help Line 01604 707011 3

2. STARTING AND STOPPING YOUR HEATER IMPORTANT: BEFORE LIGHTING YOUR WARM AIR HEATER, open the warm air outlets in all rooms, ensure any taps in the gas supply to the heater are turned on, the Thermista-stat/Room Thermostat is at a minimum setting, and the electrical supply to the heater is OFF. OPERATING CONTROL WARNING: If the pilot light is extinguished either intentionally or otherwise, no attempt should be made to relight the gas until at least 3 minutes have elapsed. Ensure the Electrical supply, time control and Selector switches are OFF. 2.1 TO LIGHT YOUR HEATER 2.1.1 Remove the heater lower front door. 2.1.2 Referring to Figure 1 & 2, identify the positions of the Multifunctional Control OPERATING CONTROL, the PILOT BURNER and IGNITION BUTTON. 2.1.3 Press and hold the OPERATING CONTROL (allowing gas to be supplied to the heater), then repeatedly press and release the LIGHTING button until the PILOT BURNER lights whilst still holding the OPERATING CONTROL depressed. After 20 seconds, release the OPERATING CONTROL and ensure the PILOT BURNER is lit. If the PILOT BURNER does not remain lit, turn the OPERATING CONTROL in the direction of the arrow and allow at least 3 minutes to elapse before repeating the lighting procedure, holding the OPERATING CONTROL depressed for a longer period than before. If the PILOT BURNER will not stay alight, consult your local gas service engineer. NOTE: (except HI-SPEC J25RS and HI-SPEC J25SC heaters) If the igniter unit fails to generate a spark, the pilot burner may be ignited by applying a lighted taper whilst the OPERATING CONTROL is pressed. Press and hold the OPERATING CONTROL and apply the lighted taper to the PILOT BURNER and ensure the PILOT BURNER lights. After 20 seconds, release the OPERATING CONTROL and ensure the PILOT BURNER remains alight. 2.1.4 Switch the electrical supply to the heater ON 2.1.5 Set the Time control to your required heating on periods. 2.1.6 Set the Thermista-stat/Room Thermostat to the required setting. 2.1.7 The heater will now operate under control of the Thermista-stat/Room Thermostat. 2.1.8 Refi t the heater lower front door. 2.2 TO TURN OFF YOUR HEATER FOR PROLONGED PERIODS (i.e. week or summer shutdown) 2.2.1 Remove the heater lower front door. 2.2.2 Turn the OPERATING CONTROL clockwise in the direction of arrow approx a ¼ turn and ensure it fully resets (springs fully out). 2.2.3 Ensure the main burner and pilot burner are extinguished. 2.2.4 Turn the gas supply to the heater OFF at the gas cock. 2.2.5 Switch off the electrical supply to the heater. 2.2 TO TURN OFF YOUR HEATER FOR LIMITED PERIODS (i.e. weekend shutdown) 2.3.1 Set the Thermista-stat/Room Thermostat to a minimum setting or OFF. This action will prevent the main burner from igniting, but will keep the pilot burner alight. To reinstate your heating, simply set the Thermista-stat/Room Thermostat to the required comfort level. PILOT BURNER FIGURE 1. HONEYWELL GAS VALVE AIR FILTER TIME CONTROL FIGURE 2. TYPICAL HI-SPEC AIR HEATER IGNITION BUTTON www.johnsonandstarley.co.uk 4

3. TEMPERATURE CONTROLS 3.1 SETTING THE THERMISTA-STAT (System E-T models) 3.1.1 The numbers on the Thermista-stat dial represent the levels of warmth, and when you select a number the heater operates automatically to maintain that level. You will soon fi nd the setting at which you are most comfortable; we suggest that you start at mark 6. When the room has warmed up, make adjustments of ½ mark steps until you are satisfi ed. The best economy is achieved at the lowest setting you fi nd comfortable. NOTE: The Thermista-stat incorporates a switch at the extreme clockwise position of the knob. This is marked as SUMMER AIRFLOW. With the knob in this position, the air heater fan will run continuously without the burner operating to provide circulation of unheated air. 3.2 SETTING THE ROOM THERMOSTAT (Non E-T models) 3.2.1 The Room Thermostat temperature of the air surrounding the Thermostat reaches the selected temperature, the Thermostat will switch the heater off. It will then automatically switch the heater on and off, several times an hour, to maintain the room temperature you have selected. Careful use of the Room Thermostat saves money. 3.3 CONTROLLING YOUR HEATING SYSTEM 3.3.1 You can control the heat to each room by opening and closing the warm air outlets, but you should never close more than half of them at the same time. Warm air outlets in the room where the Thermista-stat/Room Themostat is fi tted should always be open to make sure that the heating system is controlled properly. 3.3.2 During average winter weather, warm air outlets in rooms not having a Thermista-stat or Room Thermostat should be opened only as much as is necessary to bring the room to the desired temperature. In prolonged severe weather, it is better to set the air heater time control to ON ALL TIME overnight, and reduce the setting of the Thermista-stat or Room Thermostat. Resetting the Thermista-stat/Room Thermostat on rising will quickly raise the room temperature. This will provide general background heating. Recommended settings for these temperature controls are: a. Thermista-stat Mark 4 b. Room Thermostat 13 C (55 F) IMPORTANT: If at any time the main burner should not extinguish when there is no demand for heat, the gas valve OPERATING CONTROL should be reset. A safety device will prevent the Pilot burner from being relit for a period of 1 minute. 4. TIME CONTROLS 4.1 The integral time control (Figure 2) enables continuous or timed operation of your air heater and water heater (if fi tted), either individually or together. 4.2 The SUMMER AIRFLOW switch allows the heater to be used for circulating unheated air in the home. FIGURE 3. INTEGRAL TIME CONTROL Dummy switch for appliances without water heater Sales/Spares 01604 707012 Replacement Help Line 01604 707011 5

4.3 TIMED OPERATION 4.3.1 To set TIMED operation ON and OFF times: a. ON times are set by moving tappets IN towards the centre of the dial to show the orange band. b. OFF times are set by moving tappets OUT away from the centre of the dial to show the black band. 4.3.2 The minimum time set is 15 minutes (single tappet). 4.3.3 EXAMPLE: The ON times wanted are 07.30 am to 09.00 am, and 4.30 pm to 11.15 pm. a. Move all tappets between 07.30 to 09.00 and 16.30 to 23.15 IN. b. Move all other tappets OUT. c. Set the correct time of day by turning the dial CLOCKWISE to align the correct time numbers with the black pointer (each hour is divided into 15 minute markings). d. Set the air heater and/or water heater switches to TIMED. e. Set the Thermista-stat/Room Thermostat to the position required. 4.4 OTHER OPERATING CONDITIONS: 4.4.1 The heaters can be made to operate during the day (i.e. weekends) by setting the switches to ON ALL TIME. ( I ) Room and hot water temperatures will be controlled automatically. 4.4.2 To return to the usual ON and OFF times (i.e. overnight or during weekdays), set the switches to TIMED. 4.4.3 If heating is NOT WANTED, set the switches to the OFF position. 5. MAINTENANCE & SERVICE 5.1 AIR FILTER 5.1.1 IMPORTANT: The air fi lter should be cleaned every 2 weeks during the heating season. To clean the air fi lter, withdraw it from the heater, clean with a soft brush or vacuum cleaner and refi t. DO NOT allow the fi lter to become clogged or the heater output will become greatly reduced and fuel will be wasted. In NEW HOUSES, clean the fi lter once a week for the fi rst month or two to clear builders dust etc. 5.2 MAINTENANCE AND GAS TARIFF 5.2.1 It is recommended that a full maintenance check should be made on your appliance(s) annually by a GAS SAFE registered installer and that a service contract is taken out when the guarantee period ends. Your installer will give you details of arrangements for this service. If your installer has diffi culty in providing this information, please contact Johnson and Starley Service Department, who will provide information of suitable service companies. 5.2.2 On completion of the service the installer should fi ll in the Service Record section in the benchmark Checklist. 5.2.3 All installers registered with GAS SAFE carry an identifi cation card, this card will have an ID number which should be recorded in the Benchmark Checklist. 5.2.4 If you have any queries regarding your installer you can contact GAS SAFE by telephone on 0800 408 5500 6. TROUBLE SHOOTING 6.1 AIR HEATER NOT WORKING 6.1.1 Check that the Thermista-stat/Room Thermostat and time controls are set correctly for your requirements, and that at least half of the warm air outlets are open, especially in the room where the Thermista-stat/Room Thermostat is fi tted. 6.1.2 Check that the Pilot burner is alight. If not, follow the lighting procedure as described in Section 2. 6.1.3 Check if the air fi lter is clogged. Clean as instructed in Section 5. www.johnsonandstarley.co.uk 6

6.1.4 If your heater still does not work, call for expert advice. Johnson and Starley Service Department can provide details of suitable companies to carry out servicing and maintenance. 6.1.5 For new houses, service is usually supplied for a specifi c period under arrangements made by the local building contractor. 6.1.6 Housing Associations and Local Authorities will have arrangements for their own servicing arrangements. IMPORTANT: When replacing a mains fuse, the fuse rating MUST NOT EXCEED 5 amps. 7. EMERGENCY POWER RESTRICTIONS 7.1 If you experience an electrical power cut, the gas control on your heater, being electrically operated, will close. The main burner will go out but the Pilot burner will remain alight. When the electrical supply returns, the air heater will work normally again. 7.2 If your heating system is controlled by an electrical time control, it will be necessary to reset the clock dial as described in Section 4. 8. IMPORTANT GAS SAFETY INFORMATION (Power Cuts) FOR YOUR HEATER TO WORK EFFICIENTLY AND FOR YOUR HEATING SYSTEM TO PERFORM SATISFACTORILY, IT IS ABSOLUTELY ESSENTIAL TO OBSERVE THE FOLLOWING: 8.1 This air heater is installed in a ventilated area. DO SEEK ADVICE from your Gas Service Centre before making any alterations likely to reduce the supply of fresh air to the heater. 8.2 DO KEEP CLEAN, and make sure you DO NOT OBSTRUCT any grilles on the heater, in the heater compartment, or in any walls, windows or doors of the building. 8.3 DO CLEAN AND REFIT the air filter (if fitted) at least once per month or to the manufacturers instructions. 8.4 DO NOT PLACE ANYTHING (clothing, linen etc.) in contact with the air heater or its flue pipe. 8.5 DO NOT USE the heater compartment for storage or airing. 8.6 DO NOT turn off the mains electricity supply to the air heater until the gas supply has been turned off. 8.7 IF YOU SMELL GAS: GAS LEAK DO NOT OPERATE ANY ELECTRICAL SWITCHES, OR USE A NAKED FLAME. TURN OFF THE GAS SUPPLY. VENTILATE THE AREA BY OPENING DOORS AND WINDOWS. CONTACT THE NATIONAL GAS EMERGENCY SERVICE ON 0800 111999 Sales/Spares 01604 707012 Replacement Help Line 01604 707011 7

Johnson & Starley Ltd Rhosili Road, Brackmills, Northampton NN4 7LZ sales@johnsonandstarley.co.uk marketing@johnsonandstarley.co.uk Reception 01604 762881 Sales/Spare 01604 707012 Service/Warm Air Heating 01604 762881 Warm Air Upgrade 01604 707011 Johnson & Starley Dravo Division Industrial H&V Sales 01604 707022 sales@johnsonandstarley.co.uk www.dravo.co.uk Anniversary 1922-2012