Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB



Similar documents
GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

Installation Instructions

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

Operating Instructions for AGA BF Gas Fired Cooker Models GC, GCB, (2 Oven) 2=

AGA DUAL CONTROL. Model No s: DC3 & DC5. (Includes External Vent & Room Vent Option)

San josé OWNER S MANUAL

Installation Instructions for Rayburn 216SFW Solid Fuel and Wood Burning Cooker

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

orlando OWNER S MANUAL

AGA ELECTRIC COOKER (EC3) (3 OVEN) OWNERS MANUAL

User's Instructions. Alpha HE CB25/33 and HE SY25

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

For installation guide see reverse of book

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

MODELS BR517R & BR517S (G.C & ) & ULTIMATE TURBOCHIM* & SUPERFLAME RF* Rear & Side Fan Flued Inset Gas Fires

Response: The combi boiler. Response: The fit anywhere combi

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

HEAVY DUTY STORAGE GAS

Users Instructions for Aga Oil-Fired Cooker Models OC, OCB, (2 Oven) 2= OE, OEB, (4 Oven) =4=

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

AGA EC3 (ELECTRIC THREE OVEN) COOKER

Baxi Combi 80e & 105e

Operating instructions

HALSTEAD. Best db 30/40/50/60 HALSTEAD INSTALLATION & SERVICING INSTRUCTIONS FOR THE

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS

Operating instructions

Getting the best from your urn

Troubleshoot resources for homeowner

UNDERSTANDING CENTRAL HEATING SYSTEMS

Operating instructions

AGA Gas Fired Cooker Models GC and GE with AIMS

INSTALLATION REQUIREMENTS FOR DOMESTIC GAS WATER HEATERS ( RATED HEAT INPUT UP TO 70 kw )

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

Combi Eco Elite Range. User s Guide and Important Warranty Information

Betacom. 24c G.C. No c G.C. No Installation and Servicing. High Efficiency Condensing Combination Boilers

GREENSTAR 60/100 HORIZONTAL FLUE

HeatSource HS1800 Heater

I u SYSTEM BOILER. Central Heating Faned Flue system. Installation. System 40. System 60. heygfj& AA

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Combi 24 HE. User s Guide and Important Warranty Information

Session 2: Hot Water Supply

Mikrofill Ethos Condensing combination boiler

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

1 DESCRIPTION OF THE APPLIANCE

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Energy Saving Fact Sheet Boilers

Alpha CD13R,18R and 24R

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Combi 30 HE. User s Guide and Important Warranty Information

Gas Instantaneous Water Heater

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE)

High Output Boiler Systems

ferroli Boiler Replacement Optimax HE- Modena HE

E-gas Instant Gas Water Heaters

24CDi/28CDi/35CDi II RSF

CARING FOR YOUR WATER HEATER

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

GRANT. Vortex Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS

Installation Instructions

Bosch Group OIL HEATSLAVE

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

User Guide. Main Heat Condensing Central Heating Boiler

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler

2-SLICE COOL TOUCH TOASTER

Table of Contents. 1 List of Contents Contents included with ecomax pro boiler... 4

AGA ELECTRIC - AIMS EC & EE COOKER OWNERS MANUAL

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

User Guide. Promax System Condensing System Boiler

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Mynute 25 A. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1


Heating and Domestic Hot Water Systems for dwellings Achieving compliance with Part L 2008

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Link-Up. Solid Fuel Association Guide to Central Heating.

This section gives you some helpful information and tips on running your home and the equipment in it.

G670 Intermittent Pilot Ignition Controls

WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Safe Method: Gas Safety in Catering Establishments

High efficiency, cast-iron gas boiler

Please also see 10 golden rules for correct Saniflo installation on

Transcription:

Gas Fired Cookers Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB FOR USE IN GB & IE PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible manufacturers we take care to make sure that our products are designed and constructed to meet the required safety standards when properly installed and used. IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING WARRANTY. Any alteration that is not approved by AGA could invalidate the approval of the appliance, operation of the warranty and could affect your statutory rights. Important This appliance may contain some of the materials that are indicated. It is the Users/Installers responsibility to ensure that the necessary personal protective clothing is worn when handling, where applicable, the pertinent parts that contain any of the listed materials that could be interpreted as being injurious to health and safety, see below for information. INSTALLATION With specific exceptions, the installing of any type of AGA Cooker is subject to the respective directions contained in current issue of The Building Regulations. In addition, Planning Permission may need to be obtained, which should be applied for separately. The complete range of AGA cookers are suitable for Natural or Propane gases only and cannot be used on any other gas. The complete cooker is floor-mounted and the space in which the appliance is to be fitted must have the following minimum dimensions:- A minimum clearance of 60mm is required above the raised insulating cover handle. Side Clearances: A 3mm gap is required each side between the cooker top plate and adjoining work surfaces that maybe fitted, this is to allow for the safe removal of the top plate should this be required at a later date. Where cookers are fitted against side walls a 116mm clearance is required at the right hand side for oven doors access. (A further 116mm is necessary if a left hand side gas connection is required. If the Aga is to be installed in a brick recess, then the minimum clearances should be increased by at least 10mm on either side, to allow for the walls not being square and also for the natural dimensional variations found in the castings. In addition a minimum clearance of 1000mm must be available at the front of the cooker to enable the cooker to be serviced. Firebricks, Fuel beds, Artificial Fuels - when handling use disposable gloves. Fire Cement - when handling use disposable gloves. Glues and Sealants - exercise caution - if these are still in liquid form use face mask and disposable gloves. Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre, Kerosene Oil - may be harmful if inhaled, may be irritating to skin, eyes, nose and throat. When handling avoid inhaling and contact with skin or eyes. Use disposable gloves, face-masks and eye protection. After handling wash hands and other exposed parts. When disposing of the product, reduce dust with water spray, ensure that parts are securely wrapped. NOTE: AGA GAS FIRED COOKERS ARE DELIVERED EX-WORKS UNASSEMBLED. ASSEMBLY IS UNDERTAKEN ON SITE BY THE AUTHORISED AGA DISTRIBUTOR. Cooker Base or Hearth It is essential that the base or hearth on which the cooker stands should be level and be capable of supporting the total weight of the respective cooker. Models GC and GCB 406Kg, GE and GEB - 584Kg. The top of the hearth must be of non-combustible material thickness of 12mm. The wall behind the cooker must be of non-combustible material for a minimum thickness of 25mm. Tiling When the cooker is to stand in a recess, or against a wall which is to be tiled, in no circumstances should the tiles overlap the cooker top plate. Installation Requirements The installation of the cooker must be in accordance with the relevant requirements of the Gas Safety Regulations, Building Regulations and the bylaws of the local Water Undertaking. It should be in accordance also with any relevant requirements of the Gas Region and Local Authority. In you own interest, and that of safety to comply with the law, all gas appliances should be installed by a competent person, in accordance with the relative regulations. Failure to install appliances correctly could lead to prosecution. On completion, test the gas installation for soundness. REMEMBER, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by AGA. 1 09/10 EINS 511056

V = VENT PIPE S = FLUE PIPE A B C D E F G H J K L M N P Q R S T U V mm 987 889 851 679 41 1330 756 1125 39 3 698 499 127 41 530 116 770 484 328 828 Models GC and GCB Balanced flue GC GCB NATURAL G20 MAXIMUM HEAT INPUT 5kW 5kW Thermostat Bypass 100 or 120 120 or 140 Main Burner Injector 285 285 Pilot Injector N35 N35 Inlet Pressure G20 20mbar 20mbar PROPANE G31 MAXIMUM HEAT INPUT 5kW (357g/h) 5kW (357g/h) Thermostat Bypass 60 or 80 80 or 100 Main Burner Injector 180 180 Pilot Injector L23 L23 Inlet Pressure 37mbar 37mbar Burner Pressure 28mbar 28mbar For Natural Gas the gas valve outlet pressure is non-adjustable, BUT for reference purposes only. A pressure drop of 1-2mbar can be observed between inlet and outlet pressures on a cold appliance. 2

V = VENT PIPE S = FLUE PIPE A B C D E F G H J K L M N P Q R S T U V mm 1487 889 851 679 41 1330 756 1125 39 3 698 632 591 51 67 116 770 484 328 828 Models GE and GEB Balanced flue GE GEB NATURAL G20 MAXIMUM HEAT INPUT 5kW 5.8kW Thermostat Bypass 100 or 120 120 or 140 Main Burner Injector 285 330 Pilot Injector N35 N35 Inlet Pressure G20 20mbar 20mbar PROPANE G31 MAXIMUM HEAT INPUT 5kW (357g/h) 5.8kW (414g/h) Thermostat Bypass 60 or 80 80 or 100 Main Burner Injector 180 200 Pilot Injector L23 L23 Inlet Pressure 37mbar 37mbar Burner Pressure 28mbar 32mbar For Natural Gas the gas valve outlet pressure is non-adjustable, BUT for reference purposes only. A pressure drop of 1-2mbar can be observed between inlet and outlet pressures on a cold appliance. 3

FLUE SYSTEM The terminal is suitable for wall thicknesses from 228mm to 600mm cut size Should the installation of the appliance be in an unusual location or restricted space, special procedures may be necessary. Terminal Position The minimum acceptable spacings from the terminal to obstructions and ventilation openings are as shown in the diagram. Where the terminal is fitted within 600mm below plastic guttering an aluminium shield 1500mm long should be fitted to the underside and immediately beneath the guttering or eaves. Where the terminal is fitted within 450mm below eaves or painted guttering an aluminium shield 750mm long should be fitted to the underside and immediately beneath the guttering or eaves. Minimum siting dimensions for Balanced Flue terminals Position Minimum Spacing mm A Directly below an openable window, air vent, or an other ventilation opening 300 B Below gutter, drain/soil pipe 300 C Below eaves 300 D Below a balcony or car port roof 600 E From vertical drain pipes and soil pipes 300 F From internal or external corners 600 G Above adjacent ground or balcony level 300 H From surface facing the terminal 600 I Facing terminals 600 AROUND THE HOUSE DESN 511052 J From opening (door/window) in car port into dwelling 1200 UNDER CAR PORT, ETC. DESN 511053 K Vertical from a terminal 1500 L Horizontally from a terminal 300 Terminal Protection A terminal guard is supplied with the cooker and must be fitted if flue termination is less than 2 metres above ground level, or subject to damage. When fitted, it must be positioned to provide a minimum of 50mm clearance from any part of the terminal and be central over the terminal. 4

AIR SUPPLY Kitchen or Internal Space Air Supply Where the appliance is to be installed in a kitchen or internal space, it does not require the kitchen or internal space containing it to have a permanent air vent. INSTALLATION PIPES Installation pipes should be fitted in accordance with current Gas Regulations. Pipework from the meter/tank to the cooker must be of adequate size, cooker connection size of 15mm Dia. On completion test the gas installation for soundness and purge in accordance with current Gas Regulations. ELECTRICAL A 3Amp 230V~50Hz fused electrical supply is required adjacent to the appliance. External wiring to the fan unit must be installed using a 3 core heat resisting 85 C PVC sheathed cable and in accordance with the current Wiring Regulations and any local regulations which apply. The wiring should be completed as indicated: The method of connection to the mains electricity supply must facilitate complete electrical isolation of the appliance, preferably by the use of an unswitched shuttered socket outlet in conjunction with a fused three pin plug. Alternatively, a fused double pole switch, having a contact separation of at least 3mm in both poles, serving only the appliance may be used. THE HOT WATER SYSTEM (Models GCB and GEB Only) In a domestic hot water system, the hot water storage vessel must be of the indirect cylinder of calorifier type. The hot water storage vessel should be insulated, preferably, with not less than 75mm thick mineral fibre, or its equivalent. Pipework not forming part of the useful heating surface should be insulated to help prevent heat loss and possible freezing, particularly where pipes are run through roof spaces and ventilated under floor spaces. Cisterns situated in areas which may be exposed to freezing conditions should also be insulated. Draining taps must be located in accessible positions which permit the draining of the whole system, including the boiler and hot water storage vessel. Draining taps should be at least 15mm nominal size. The use of horizontal pipe runs should be avoided wherever possible in order to prevent the collection of air in the system. If horizontal runs are unavoidable, the pipes should rise upwards in the direction away from the boiler. Hot water systems should be in accordance with the relevant recommendations. Water Circulation System (Models GCB and GEB only) The cooker boiler should be connected to a cistern water supply and subject to a maximum head of 18.25m and minimum 1m. The 28mm minimum diameter primary flow pipe must rise continuously from the cooker boiler to the cylinder to ensure good gravity circulation and have an open vent. The 28mm diameter primary flow and return pipes must not exceed 5.5m in length and be well insulated. Water Connections (Models GCB and GEB only) The two 28mm copper flow and return pipes from the boiler can be obtained for right or left hand connections. Hot Water Storage Vessel It is recommended that an indirect 190 litre (40 gallon) hot water storage cylinder of the double feed type should be lagged and fixed vertically as near as possible to the cooker. The water draw-off pipes to the taps must be dead leg connection from the vent/expansion pipe. A drain tap must be fitted at the lowest point of the system. Cooker Boiler Heat Exchanger The heat exchanger must be connected to a 190 litre (40 gallon) copper double feed indirect cylinder. 5

6 DESN 510252 A 5 OFF ON COMMISSIONING LIGHTING THE BURNER - Fig. 2 CAUTION: NO SMOKING OR NAKED LIGHTS Open the outer burner door to expose the gas control combination valve. OFF CAUTION: BEFORE LIGHTING: ENSURE THAT THE GAS VALVE CONTROL KNOB 2 IS SET IN THE OFF POSITION (SEE FIG. A) AND COMBUSTION DISCHARGE SAFETY DEVICE BUTTON IS DEPRESSED. FIG A 1. Turn off union gas cock 1. Test the gas installation from the meter cock for soundness and purge. 2. Turn on gas supply to cooker and open gas cock 1. 3. Turn the gas valve control knob 2 anti-clockwise to the position (see Fig. B.). Press down and hold the knob in the position while depressing the piezo ignitor 3 several times until the pilot has lit. This can be observed through the viewing window 4. 4. When the pilot has lit continue to hold the gas valve control knob for approximately 30 seconds. If it goes out, wait 3 minutes and repeat the procedure holding for a little longer. 5. With the pilot flame established, release the gas valve control knob 2 gradually and rotate anti-clockwise to its low fire position. Where upon the main burner will automatically light. Leave in the low fire position for at least 30 minutes. NOTE: ANY ATTEMPT TO ROTATE THE CONTROL KNOB BEFORE RELEASE MAY RESULT IN DAMAGE. 6. After 30 minutes rotate the control knob further anticlockwise to the mid-position of the green band for normal running (see Fig. D). FIG B FIG C FIG D IGNITION WHITE BLOCK LOW FIRE GREEN BAND NORMAL RUNNING 6

NOTE: AFTER SEVERAL HOURS THE HEAT INDICATOR SHOULD BE ON OR ABOUT THE CENTRE OF THE SILVER SECTION. IT MAY BE NECESSARY TO ADJUST THE CONTROL KNOB SLIGHTLY IN THE GREEN BAND TO ACHIEVE THIS. IF THE FLAME HAS EXTINGUISHED FOR WHATEVER REASON, WAIT THREE MINUTES (MINIMUM) BEFORE RE-LIGHTING. 7. On the first lighting or if the cooker has been cold for a long time. moisture from the insulation may run down the enamelled front of the cooker. This should be wiped off to prevent staining. INSTRUCTIONS Hand these and the Operating Instructions to the User for retention and instruct in the safe operation of the appliance. Advise the User of the precautions necessary to prevent damage to the Domestic Hot Water System and to be building in the event of the Domestic Hot Water System remaining inoperative during frost conditions. Finally advise the User that, for continued efficient and safe operation of the appliance it is important the adequate servicing is carried out at regular intervals recommended by the Aga Distributor or local Gas Region. 8. Check the inlet gas pressure is as indicated in the data plate as follows: (i) Turn the gas valve control knob 2 to OFF position (see Fig. A). Remove the inlet pressure test nipple plug 5 and fit pressure gauge. Turn gas valve control knob 2 to the mid position of green band. (ii) Check inlet pressure correctly corresponds to the data plate. (iii)check that the gas pressure is unaffected when other gas appliances are used. (iv)turn gas valve control knob 2 to ignition position (see Fig. B). Remove the pressure gauge and replace gas nipple plug. Turn gas valve control knob 2 to the mid-position of the green band for normal running. NOTE FOR L.P. COOKERS ONLY Repeat instruction 8 on completely cold cooker with the pressure gauge fitted to the burner pressure test point 6. Check that the burner pressure correctly corresponds to the table on pages 2 or 3. NOTE: IF FOR ANY REASON A GAS RATE CHECK IS REQUIRED, TURN OFF ALL OTHER APPLIANCES USING GAS AND USING THE GAS METER TEST DIAL AND STOP WATCH, CHECK THAT THE MAXIMUM GAS INPUT IS AS INDICATED ON THE DATA PLATE. Once the correct setting has been confirmed, the heat control will operate automatically to maintain the cooker at full temperature. NOTE: REMEMBER TO NOTE THE SETTING POSITION IF TURNING OFF THE COOKER. 7

With AGA's policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any time. AGA For further advice or information contact your Station Road local AGA Specialist Ketley Telford Shropshire TF1 5AQ www.aga-web.co.uk www.agalinks.com England www.agacookshop.co.uk 8