Dual Fiber SFP Series

DWDM SFP Series. Power budget* (note2) Laser

DWDM SFP Series. Power budget* (note2) Laser

SFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

Product Specification 10Gb/s BIDI SFP+ Transceiver

155Mbps DFB SFP Optical Transceiver, 120km Reach

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

4.25Gbps SFP Optical Transceiver, 30km Reach

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

LONGLINE 40km XFP Optical Transceiver

10/100/1000BASE-T SFP Transceiver

GPON OLT Optical Transceiver SFP Module RTXM Features

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

LONGLINE 2km XFP Optical Transceiver

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

1.25Gbps GBIC Optical Transceiver, 20km Reach

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

SFP Copper Transceiver 10/100/1000Base-T

RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet

EPON ONU Optical Transceiver SFF Module

XFP Optical Receiver, 80km Reach

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

Product Specification ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

10GBASE-LR XFP Optical Transceiver AXM752

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

X2 LR Optical Transponder, 10Km Reach

GBIC CWDM 40km Part no:

10GBASE -LRM, 220m Reach GX LRMC

10GBASE-SR XFP Optical Transceiver AXM751

Intel Ethernet SFP+ Optics

RoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, ST Duplex Plastic Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet

1000BASE-BX-OLT Transceiver

Dispersion penalty test 1550 Serial

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Cisco SFP Optics for Gigabit Ethernet Applications

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

3G-SDI/HD-SDI/SD-SDI Electric to Optical Converter EO3G-200

155Mbps ATM-Single Mode Transceiver

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

Golden test for dispersion penalty 1550 Serial

Photolink- Fiber Optic Receiver PLR135/T1

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

DM/SP7041-X 1000BASE-T

155 Mb/s Fiber Optic Light to Logic Receivers for OC3/STM1

BF15U REV DESCRIPTION DATE APPROVED 2 Preliminary 1/7/2016 RAS/MF

PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

TS321 Low Power Single Operational Amplifier

1000 BASE-X SFP. Key Features DATA SHEET HIGHLIGHTS 1000BASE-SX 1000BASE-LX 1000BASE-ZX 1000BASE BX-D*

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

VS-500 Voltage Controlled SAW Oscillator

Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

MASW TB. GaAs SPST Switch, Absorptive, Single Supply, DC-4.0 GHz. Features. Pin Configuration 1,2,3,4. Description. Ordering Information

CMOS 5GHz WLAN a/n/ac RFeIC WITH PA, LNA, AND SPDT

Signal Types and Terminations

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

+5 V Powered RS-232/RS-422 Transceiver AD7306

STRATO LED Drivers 70W, Single output

Silvertel. Ag9800M. 1. Features. 2. Description. Miniature PoE Module. Small SMT package. IEEE802.3af compliant. Low cost

Features. Modulation Frequency (khz) VDD. PLL Clock Synthesizer with Spread Spectrum Circuitry GND

Infrared Remote Control Receiver Module IRM-2638T

Un-cooled Multimode Pump Laser Module for Telecom Applications

ACT4077 Driver for MACAIR A3818, A5690, A5232, A4905 & MIL-STD-1553

ADQYF1A08. DDR2-1066G(CL6) 240-Pin O.C. U-DIMM 1GB (128M x 64-bits)

STF & STF201-30

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

User manual Rev. 1.2 (17/04/2015)

LOW POWER SPREAD SPECTRUM OSCILLATOR

ICS SPREAD SPECTRUM CLOCK SYNTHESIZER. Description. Features. Block Diagram DATASHEET

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

FM Radio Transmitter & Receiver Modules

Cisco 10GBASE SFP+ Modules

NI USB-5681 RF Power Meter Specifications

11. High-Speed Differential Interfaces in Cyclone II Devices

Series AMLDL-Z Up to 1000mA LED Driver

IR Receiver Module for Light Barrier Systems

STF THRU STF203-33

Optocoupler, Phototransistor Output, with Base Connection

Transcription:

EOLS-BI1612-10-CL XX Series EOLS-BI1612-10-LC XX Series Single-Mode 100Mbps to 1.25Gbps FE/GBE /FC SC/LC Single-Fiber SFP Transceiver RoHS6 Compliant Features Support 1.25Gbps Data Links A type: 1310nm FP TX /1490nm RX B type: 1490nm DFB TX /1310nm RX Up to 10km with 9/125 µm SMF Single 3.3V Power supply and TTL Logic Interface Hot-Pluggable SFP Footprint Simplex SC/LC Connector Interface Class 1 FDA and IEC60825-1 Laser Safety Compliant Operating Case Temperature Standard: 0 ~+70 Applications Fiber Channel Links WDM Gigabit Ethernet Links Other Optical Links Industrial:-40 ~+85 Compliant with SFP MSA Specification Compliant with Digital Diagnostic Monitor Interface SFF-8472 FTTX Application Ordering Information Part No. Data Rate Wavelength Interface Temp. DDMI EOLS-BI1612-10-CL* (note1) 0.1~1.25Gbps 1310nm SC Standard NO EOLS-BI1612-10-LC* (note1) 0.1~1.25Gbps 1490nm SC Standard NO EOLS-BI1612-10-CLI EOLS-BI1612-10-LCI EOLS-BI1612-10-CLD EOLS-BI1612-10-LCD 0.1~1.25Gbps 1310nm SC Industrial NO 0.1~1.25Gbps 1490nm SC Industrial NO 0.1~1.25Gbps 1310nm SC Standard YES 0.1~1.25Gbps 1490nm SC Standard YES Page 1 of 12

EOLS-BI1612-10-CLDI EOLS-BI1612-10-LCDI 0.1~1.25Gbps 1310nm SC Industrial YES 0.1~1.25Gbps 1490nm SC Industrial YES EOLS-BI1612-10-CLL* (note1) 0.1~1.25Gbps 1310nm LC Standard NO EOLS-BI1612-10-LCL* (note1) 0.1~1.25Gbps 1490nm LC Standard NO EOLS-BI1612-10-CLIL EOLS-BI1612-10-LCIL EOLS-BI1612-10-CLDL EOLS-BI1612-10-LCDL EOLS-BI1612-10-CLDIL EOLS-BI1612-10-LCDIL Note1: Standard version Regulatory Compliance 0.1~1.25Gbps 1310nm LC Industrial NO 0.1~1.25Gbps 1490nm LC Industrial NO 0.1~1.25Gbps 1310nm LC Standard YES 0.1~1.25Gbps 1490nm LC Standard YES 0.1~1.25Gbps 1310nm LC Industrial YES 0.1~1.25Gbps 1490nm LC Industrial YES Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI) Immunity Laser Eye Safety Component Recognition MIL-STD-883G Method 3015.7 EN 55024:1998+A1+A2 IEC-61000-4-2 GR-1089-CORE FCC Part 15 Class B EN55022:2006 CISPR 22B :2006 VCCI Class B EN 55024:1998+A1+A2 IEC 61000-4-3 FDA 21CFR 1040.10 and 1040.11 EN (IEC) 60825-1:2007 EN (IEC) 60825-2:2004+A1 UL and CUL EN60950-1:2006 Class 1C (>1000 V) Compliant with standards Compliant with standards Noise frequency range: 30MHz to 6GHz. Good system EMI design practice required to achieve Class B margins. System margins are dependent on customer host board and chassis design. Compliant with standards. 1KHz sine-wave, 80% AM, from 80MHz to 1GHz. No effect on transmitter/receiver performance is detectable between these limits. CDRH compliant and Class I laser product. TüV Certificate No. 50135086 UL file E317337 TüV Certificate No. 50135086 (CB scheme ) Page 2 of 12

2002/95/EC 4.1&4.2 RoHS6 Compliant with standards *note3 2005/747/EC 5&7&13 Note2: For update of the equipments and strict control of raw materials, EOPTOLINK has the ability to supply the customized products since Jan 1 st, 2007, which meet the requirements of RoHS6 (Restrictions on use of certain Hazardous Substances) of European Union. In light of item 5 in RoHS exemption list of RoHS Directive 2002/95/EC, Item 5: Lead in glass of cathode ray tubes, electronic components and fluorescent tubes. In light of item 13 in RoHS exemption list of RoHS Directive 2005/747/EC, Item 13: Lead and cadmium in optical and filter glass. The three exemptions are being concerned for Eoptolink s transceivers, because Eoptolink s transceivers use glass, which may contain Pb, for components such as lenses, windows, isolators, and other electronic components. Product Description The EOLS-BI1X12-X series is small form factor pluggable module for Gigabit Ethernet 1000BASE-BX and Fiber Channel single fiber applications by using 1310nm / 1490nm transmitter and 1490nm / 1310nm receiver. It is with the SFP 20-pin connector to allow hot plug capability. The transmitter section uses a class 1 laser compliant according to International Safety Standard IEC 60825. The receiver section uses an integrated B type / A type detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. The EOLS-BI1X12-XD series are designed to be compliant with SFF-8472 Multi-source Agreement (MSA). Absolute Maximum Ratings Parameter Symbol Min. Max. Unit Storage Temperature Ts -40 +85 C Supply Voltage Vcc -0.5 3.6 V Operating Relative Humidity - 95 % *Exceeding any one of these values may destroy the device immediately. Recommended Operating Conditions Parameter Symbol Min. Typical Max. Unit Operating Case EOLS-BI1X12-X 0 +70 TA Temperature EOLS-BI1X12-XI -40 +85 C Power Supply Voltage Vcc 3.15 3.3 3.45 V Power Supply Current Icc 300 ma Date Rate 1.25 Gbps Page 3 of 12

Performance Specifications - Electrical Parameter Symbol Min. Typ. Max Unit Notes Transmitter LVPECL Inputs(Differential) Input Impedance (Differential) TX_Dis TX_FAULT LVPECL Outputs (Differential) Output Impedance (Differential) RX_LOS MOD_DEF ( 0:2 ) Vin 400 2000 mvpp Zin 85 100 115 ohm Disable 2 Vcc+0.3 Enable 0 0.8 Fault 2 Vcc+0.3 Normal 0 0.5 Receiver Vout 400 2000 mvpp Zout 85 100 115 ohm LOS 2 Vcc+0.3 V Normal 0 0.8 V Optical and Electrical Characteristics VoH 2.5 V VoL 0 0.5 V (EOLS-BI1612-10-CL, 1310nm FP and PIN, 10km) Page 4 of 12 V V AC coupled inputs* (note5) Rin > 100 kohm @ DC AC coupled outputs* (note5) With Serial ID Parameter Symbol Min. Typical Max. Unit 9µm Core Diameter SMF L 10 km Data Rate 1250 Mbps Transmitter Center Wavelength λ C 1270 1310 1350 nm Spectral Width (RMS) Δλ 3.5 nm Average Output Power* (note3) Pout -9.5-3 dbm Extinction Ratio @ 1250Mbps ER 9 db Rise/Fall Time(20%~80%) tr/tf 0.26 ns Total Jitter TJ 260 ps Output Optical Eye* (note4) Compliant with IEEE 802.3z* (note7) TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Receiver Center Wavelength λ C 1450 1490 1530 nm Receiver Sensitivity* (note6) @1250Mbps Pmin -22 dbm Receiver Overload Pmax -3 dbm

LOS De-Assert@1250Mbps LOSD -23 dbm LOS Assert LOSA -45 dbm LOS Hysteresis* (note8) 0.5 db (EOLS-BI1612-10-LC, 1490nm DFB and PIN, 10km) Parameter Symbol Min. Typical Max. Unit 9µm Core Diameter SMF L 10 km Data Rate 1250 Mbps Transmitter Center Wavelength λ C 1480 1490 1500 nm Spectral Width (-20dB) Δλ 1 nm Average Output Power* (note3) Pout -9.5-3 dbm Extinction Ratio @ 1250Mbps ER 9 db Side Mode Suppression Ratio SMSR 30 db Rise/Fall Time(20%~80%) t r /t f 260 ps Output Optical Eye* (note4) Compliant with IEEE 802.3ah-2004* (note7) TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Receiver Center Wavelength λ C 1260 1360 nm Receiver Sensitivity* (note6) @1250Mbps Pmin -22 dbm Receiver Overload Pmax -3 dbm Return Loss 12 db Optical Path Penalty 1 db LOS De-Assert@1250Mbps -23 dbm LOSD LOS De-Assert@100Mbps -23 dbm LOS Assert LOSA -45 dbm LOS Hysteresis* (note8) 0.5 db Note3: Output is coupled into a 9/125μm single-mode fiber. Note4: Filtered, measured with a PRBS 2 7-1. Note5: LVPECL logic, internally AC coupled. Note6: Measured at all data rates specified in Data Rate table with ER=9 db, 2 7-1 PRBS data pattern, BER <1E-12. Note7: Eye Pattern Mask Note8: LOS Hysteresis Page 5 of 12

Functional Description of Transceiver SFP Transceiver Electrical Pad Layout Page 6 of 12

Pin Function Definitions Pin Plug Name Function NO. Seq. Notes 1 VeeT Transmitter Ground 1 5) 2 TX Fault Transmitter Fault Indication 3 1) 3 TX Disable Transmitter Disable 3 2) Module disables on high or open 4 MOD-DEF2 Module Definition 2 3 3) Data line for Serial ID. 5 MOD-DEF1 Module Definition 1 3 3) Clock line for Serial ID. 6 MOD-DEF0 Module Definition 0 3 3) Grounded within the module. 7 Rate Select Not Connect 3 Function not available 8 LOS Loss of Signal 3 4) 9 VeeR Receiver Ground 1 5) 10 VeeR Receiver Ground 1 5) 11 VeeR Receiver Ground 1 5) 12 RD- Inv. Received Data Out 3 6) 13 RD+ Received Data Out 3 6) 14 VeeR Receiver Ground 1 5) 15 VccR Receiver Power 2 7) 3.3 ± 5% 16 VccT Transmitter Power 2 7) 3.3 ± 5% 17 VeeT Transmitter Ground 1 5) 18 TD+ Transmit Data In 3 8) 19 TD- Inv. Transmit Data In 3 8) 20 VeeT Transmitter Ground 1 5) Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 10 KΩ resistor. Its states are: Low (0 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Modulation Absent, connected to VEET or VEER in the module. 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. Page 7 of 12

5) VeeR and VeeT may be internally connected within the SFP module. 6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. 7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module. 8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not write protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. If the module is defined as external calibrated, the diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2H. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 9.3. Page 8 of 12

Recommended Circuit Schematic Page 9 of 12

Mechanical Specifications SC LC Page 10 of 12

Laser Emission Data Wavelength Total output power (as defined by FDA: 7mm aperture at 20cm distance) Total output power (as defined by IEC: 7mm aperture at 10cm distance) 1310nm <0.195mW <15.6mW Beam divergence 12.5 Wavelength Total output power (as defined by FDA: 7mm aperture at 20cm distance) Total output power (as defined by IEC: 7mm aperture at 10cm distance) 1490nm <0.79mW <10mW Beam divergence 12.5 Laser Emission Obtaining Document You can visit our website: http://www.eoptolink.com Or contact listed at the end of the documentation to get the latest document. Page 11 of 12

Revision History Revision Release Revision Initiated Reviewed Approved History Date V3.a Cathy Kelly Released. Mar 27, 2010 V4.a V4.b Phlio Phlio V4.c Phlio Kelly Update Recommend Circuit Change Link Budget and Remove EEPROM Information Update Product Picture Aug 10, 2011 Aug 22, 2011 Oct 17, 2011 V4.d Kelly Update photo. Nov 4, 2011 Arvin Kelly Update the average output power July 24, 2012 Notice: Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add: Floor 5, Building 2, No. 21 Gaopeng Avenue, High-Tech District, CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 028-85122709 ext 816 & 809 Fax: (+86) 028-85121912 Postal: 610041 E-mail:sales@eoptolink.com http://www.eoptolink.com Page 12 of 12