Jay R. Smith Mfg. Co.



Similar documents
INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

Basic Principles for Sizing Grease Interceptors

MIFAB INTERCEPTOR SELECTION GUIDE

Editorial Note: bold and underline denotes added text, strikethrough denotes deleted text

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

PLUMBING ROUGH IN INSPECTION

GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS AND INTERCEPTORS

National Precast Concrete Association

SAN JACINTO RIVER AUTHORITY GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS, INTERCEPTORS AND SEPERATORS

Oil Interceptors. The Most Effective Way to Remove Oil and Grease From Water

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

Best Management Practices Fats, Oils, & Grease

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Guidelines for Precast Concrete Grease Interceptors

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Jay R. Smith Mfg. Co.

Grease Traps and Interceptors

Grease Trap Maintenance, Procedures and Cleaning Logs

City of Clare Grease and Sand Interceptor Policy

Top 10+ Mistakes of DWV plumbing design

Manual contents includes:

CHAPTER 11 STORM DRAINAGE

POLICY. (EFFECTIVE January 1, 2000)

Plumbing for retail food businesses

Fats, Oil, and Grease (FOG) Best Management Practices (BMP) For Food Service Facilities. Guidance Manual

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 10 - TRAPS AND INTERCEPTORS 1 2 1/AC AC SS SS/CC

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

CHAPTER 11 STORM DRAINAGE

Carriers, Fixtures & Piping

Louisville and Jefferson County. Metropolitan Sewer District Fats, Oils & Grease (FOG) Management Guidelines. Policy Adopted: May 27, 2008

Best Management Practices and Grease Control Device Maintenance for Food Service Establishment Employees

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Food Service Facilities

Hydro Mechanical v. Gravity Grease Interceptors TS Saturday 9:00am 12:00pm Rand Ackroyd

How do I clean my grease trap? Refer to Grease Trap and Interceptor Maintenance.

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

OPERATION & MAINTENANCE MANUAL

FOOD SERVICE WASTEWATER DISCHARGE PERMIT APPLICATION

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Septic System Owner s Manual

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

CHAPTER 10 TRAPS AND INTERCEPTORS

Air Eliminators and Combination Air Eliminators Strainers

Grease Interceptor. If it s a. then why not size by grease production? Presented by: Sean Duffy. Schier Products Company 2012

Element D Services Plumbing

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

Montgomery County Health Department Mobile Food Guidelines. Definitions

40 ltr Domestic Grease Trap GTO ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

FULL LINE CATALOG. Effective January 1, 2014 GREASE SEPARATORS SOLID WASTE SEPARATORS GREASE INTERCEPTORS CATCH BASINS SEDIMENT SEPARATORS

SECTION 3 SANITARY SEWER DESIGN

MODEL WEB CONTENT FOR CITY SANITARY SEWER DEPARTMENTS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Float and Thermostatic Traps Series H, C and X

PLUMBING & CROSS-CONNECTION CONTROL

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

BLADDER SURGE CONTROL SYSTEM

SECTION SOIL AND WASTE SYSTEMS

Prevent Blockages in the Sanitary Sewer System

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

What to Expect From the Examination. How to Study the Plumbing Codes

1.2 How Does FOG Affect You? The City of Huntington Beach FOG Control Program.. 2

When Should Examination Preparation Begin?

Fats, Oil, and Grease Best Management Practices Manual. Pollution Prevention and Compliance Information for Publicly-Owned Treatment Plants

15430 SAFETY SHOWERS AND EYEWASHES

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES

2006 IPC INTERNATIONAL PLUMBING CODE AMENDMENTS PLANNING & DEVELOPMENT SERVICES DEPARTMENT

SANITARY SEWER SPECIFICATIONS

Disposal of Fats, Oils, Grease and Food Waste Best Management Practice for Catering Outlets

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

NPCA WHITE PAPER DESIGN CONSIDERATIONS AND DISCUSSION OF PRECAST CONCRETE GRAVITY GREASE INTERCEPTORS

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Homeowner s Guide to Maintaining a Sewage Treatment System

4.3 Cisterns and Rain Barrels

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

FATS, OILS, AND GREASE (FOG) CONTROL RULE FOR FOOD SERVICE ESTABLISHMENTS BUTLER COUNTY DEPARTMENT OF ENVIRONMENTAL SERVICES (BCDES)

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

FOG PRETREATMENT INFORMATION. New London Public Utilities F.O.G. Program 120 Broad Street New London, CT 06320

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

SF15K SF05KSS, SF10KSS

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

IBC Tote Containment Sumps

300 Series PA Pump and Cooler Assemblies

Fats, Oils and Grease

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Welcome: What is U Drain? Drain Materials. Flow

Amendments to the 2012 International Plumbing Code

Chicago Plumber Licensure Examination Information

The Next Generation in Storm Sewer Inlet Controls

Department of Public Utilities. Information for Property Owners & Residents about Sewer Backup Incidents. September 2014.

Transcription:

Jay R. Smith Mfg. Co. G u i d e T o I n t e r c e p t i o n Traditional G.I. Semi-Automatic Draw-off G.I. Custom Made, Special Quote, Interceptors P.O. Box 3237 Montgomery, AL 36109-0237 Tel:334-277-8520 Fax: 334-272-7396 www.jrsmith.com

THE TRADITIONAL GREASE INTERCEPTOR 8000 SERIES Overview The Traditional grease interceptor line is the cornerstone product of the Pioneering concept. For more than fifty years, Jay R. Smith Mfg. Co. has conducted hundreds of tests, in the laboratory and in the field, in order to offer the most efficient Grease Interceptors with improved operational characteristics suitable for most applications. The Traditional Grease Interceptor is designed for practical applications. These interceptors bear the certification seal of the Plumbing and Drainage Institute (PDI). Rating, sizing and special features of these units can be found in the Smith Yellow Pages Catalog, 8000 Series Interceptors. The Traditional line may be installed either on-grade, semi-recessed or fully recessed in the floor. In addition, the fully recessed installations have the option of a partially or completely enclosed cradle to act as a drip pan. Maintenance Even the best designed interceptors that are properly installed will fail if they are not maintained. Maintenance must be performed before the grease in the waste water down stream of the interceptor exceeds 100 parts per million (100 milligrams per liter) or in accordance with local code*. If user must comply with a code which limits grease to 100 parts per million, cleaning is recommended every 2 or 3 days. When cleaning is performed, it should be understood to always include the removal of grease from the top of the separation chamber as well as any solids which have accumulated along the bottom. See Figure 1. *See PDI Guide to Grease Interceptors, Eliminating the Mystery, page 8 for greater detail on maintenance. How the Traditional Grease Interceptor Works The Traditional Grease Interceptor has an external flow control fitting properly sized and installed to regulate the flow into the unit. This allows the grease-laden water to enter at a controlled rate of flow, free of turbulence. The water interacts with strategically located baffles to separate the grease from the water. Once separated, the grease contaminants rise to the surface of the water in the unit by natural flotation and are accumulated until removed. A regular manual cleaning interval must be established for maintaining proper discharge efficiency. Traditional Interceptor Guide Specification The Traditional Grease Interceptor, which is often referred to as a passive or manual unit, utilizes the gravity separation principle. The rate of flow into the interceptor is controlled by a flow control fitting, enabling the interceptor to collect over 90% of the grease which flows into it. Uni-lock cover design permits convenient cover removal for periodic cleaning. The interceptor may be set on the floor, semi-recessed or recessed with cover flush with finished floor. Low rough-in designs are available for use with low roughing sinks. The unit is constructed from gray duco coated fabricated steel complete with removable baffles, gasketed cover, external flow control fitting, internal air relief by-pass, cleanout plug and visible double wall trap seal. Available options include lift out sediment bucket and aluminum cover or cover recessed for terrazzo or tile. These units may also be fabricated from type 304 stainless steel. 2 When to Use the Traditional Unit The Traditional Grease Interceptor is recommended for areas where the accumulation of grease, fat, oil or other similar line-clogging contaminants should be prevented from entering the drainage line. The Traditional Grease Interceptor should always be considered when designing the plumbing drainage system in any restaurant, cafeteria, hotel, school, hospital, institutional or commercial building as well as food processing plants, dairies and other industries having facilities for the preparation and serving of food in quantity. In these installations, where grease and fats are by-products, an efficient Smith interceptor should be installed to prevent this material from entering the drainage line. FIGURE 1: Grease Interceptor Cleaning And Maintenance Remove cover. Inspect Interceptor. Remove grease (FOG) from top of separation chamber. Remove any solids from bottom of chamber. Make certain all passages, including air relief, are clear of obstructions. Check integrity of baffles and make sure they are in place. Check cover gasket for any damage. Replace if necessary. Reinstall cover. Tighten cover hold down apparatus. Lock and Lift Ring Non-Skid Cover Inlet Flow Control Separation Chamber Cleanout Neoprene Gasket Air Relief Static Water Line Removable Baffles Outlet Figure 1

TRADITIONAL GREASE INTERCEPTOR W/SEMI-AUTOMATIC DRAW-OFF 8000GT SERIES 3 Overview Smith GT Series Semi-Automatic Draw-off Grease Interceptors offer the same intercepting efficiency as the Traditional manually cleaned models, but minimize the effort involved in the unsanitary and undesirable job of removing the accumulated grease manually. The Semi-Automatic Draw-off Interceptor eliminates: Cover removal and Manually removing accumulated grease. Since cleaning a GT interceptor is simple, fast and efficient, maintenance personnel will more likely follow the regular cleaning schedule. This is a distinct advantage over the Traditional units which are frequently left unattended. The Semi-Automatic Draw-off Grease Interceptors are designed for floor mount installation. When to Use the Semi-Automatic Unit The Semi-Automatic Draw-off Grease Interceptor is recommended for areas where a regular cleaning schedule is difficult to maintain, and when no one wants to deal with removing the accumulated grease from a Traditional Grease Interceptor. The Semi-Automatic Draw-off Grease Interceptor makes it easy for maintenance personnel to extract grease, fat, oil, or other similar line-clogging contaminants that would otherwise enter the drainage line. Like the Traditional Grease Interceptors, the Semi-Automatic Draw-off is ideal for plumbing drainage systems in any restaurant, cafeteria, hotel, school, hospital, institutional or commercial building, or food processing plant having facilities for preparing and serving food in quantity. The frequency of the draw-off cycle is determined by the use load factor of the interceptor. The cleaning cycle can be set after the unit is in operation for several weeks. By observing the amount of grease collected and the frequency of use, the operator can determine a practical cleaning cycle. How the Semi-Automatic Interceptor Works 1. Unit in normal use has the line shut-off valve open and draw-off valve closed. When cleaning is required*, run a full stream of hot water through interceptor. It is preferable to have this water at 140 or higher, running for a period of at least two minutes. 2. Turn off hot water running into the interceptor and wait for a period of three to five minutes for the grease to liquefy. 3. Draw-off cycle can now be started. Close the line shut-off valve (A). 4. Open draw-off valve (B) at top of the interceptor and place a container underneath this valve. Run hot water through interceptor at a rate between 1-1/2 and 2-1/2 G.P.M. 5. After water has run into interceptor at this rate for a short period, the unit will fill. Accumulated liquefied grease will be raised into cone (C) and draw-off piping. INLET Grease Accumulating Cone (C) G-Cleanout Air Relief Static Water Line Removal Baffles 6. Allow accumulated liquefied grease to flow out of draw-off valve until clear water appears. 7. When clear water appears, shut off flow of hot water into interceptor, turn line shut-off valve to open position. 8. Close draw-off valve at top of interceptor. 9. Interceptor at this stage is ready again for normal use. GT Series Semi-Automatic Draw-Off Grease Interceptor Guide Specification The GT Series Semi-Automatic Draw-Off Grease Interceptor utilizes the gravity separation principle along with a unique semi-automatic draw-off design which permits removal of accumulated grease without cover removal. The rate of flow into the interceptor is controlled by a flow control fitting enabling the interceptor to collect over 90% of the grease which flows into it. Cover and Grease Accumulating Cone design permits fast removal of accumulated grease during established cleaning intervals. Low rough-in designs are available for use with low roughing sinks. The unit is constructed from gray duco coated fabricated steel complete with grease accumulating cone, line shut-off valve, draw-off valve, removable baffles, gasketed cover, external flow control fitting, internal air relief by-pass, cleanout plug and visible double wall trap seal. These interceptors may also be fabricated from type 304 stainless steel. Line Shut-off Valve (A) OUTLET Separation Chamber Draw-Off Valve (B)

CUSTOM MADE, SPECIAL QUOTE, INTERCEPTORS Overview When a job specification or construction project requires an interceptor to do more than just prevent fat, oil, and grease (FOG) from entering the city s sanitary sewer system, Jay R. Smith Mfg. Co. offers a variety of interceptors to meet your specific needs from the innovative Remediator Grease Treatment System, as well as a variety of specialty interceptors. Speciality Engineering For a complete line of specialty interceptors, look to Jay R. Smith Mfg. Co. Our in-house staff of engineers possess the technical knowledge to confer with engineers and contractors to design an interceptor to meet a special application, product modification, or installation need. We look forward to the challenge of designing and manufacturing special products which solve our customer s needs. No cookie cutter approach here, our designs are customer specified to get the job done. Speciality Interceptors Our full line of interceptors are designed for adaptability, conformance to code, ease of installation, and maximum performance efficiency. Some of the speciality interceptors available from Jay R. Smith Mfg. Co.: Fish Scale Interceptor, SQ-8-1164 Slurry/Pulper Waste Retention Interceptor, SQ-8-1637 Animal Fur/Hair Interceptor, SQ-8-2180 Sand Sump with Solids Interceptor, SQ-8-1099 Solids Interceptors, 8700 Series Sand Interceptors, 8800 Series Lint and Sediment/Oil Interceptors, 8900 Series Custom Made, Special Quote, Products We have more than 77 years of experience in designing new products to meet unusual specification requirements for particular jobs. The Jay R. Smith Mfg. Co. Special Quote Products job studies binder holds a wealth of products solutions for a variety of installation needs. To order a copy or to talk about your spec requirements, please contact your local representative or us at www.jrsmith.com Featured Product: SQ-8-2180, Animal Fur/Hair Interceptor - 10, 20, 25, and 50 g.p.m. Problem: A major pet store chain provides complete grooming facilities. The washing and trimming of the animals create excessive animal fur resulting in continuous stoppages in the building sewer. Goal: Provide an interceptor that will retain the majority of the animal fur along with a removable sediment bucket. Solution: An interceptor is designed to accommodate the flow along with the anticipated quantity of fur. A sediment bucket constructed of stainless steel framing and mesh was supplied to meet the requirement for a durable and non-corrodible material. A secondary screen was also included between the bucket and the outlet. Result: The stoppage in the building sewer was resolved. This unit may also be suitable for applications including veterinary clinics, kennels, beauty salons, and barber shops, wherever fur/hair may present a problem. SQ-8-2180, Animal Fur/Hair Interceptor Secured Gasketed Cover Made From 3/16 (5) Diamond Plate Anchor Flange (When Specified) Optional (2) 2" (51) Vent Connections Removable Secondary Screen INLET Static Water Line Lift Ring OUTLET Offset (By Others) 4 Suggested Piping Arrangement (By Others) Removable Stainless Steel Mesh Bucket

TABLE 2: SIZING AND RATING PDI Size Symbol 4 7 10 15 20 25 35 50 Flow Rate GPM 4 7 10 15 20 25 35 50 L/s.25.44.63.95 1.26 1.58 2.20 3.16 Grease Capacity Pounds 8 14 20 30 40 50 70 100 KG 3.6 6.4 9.1 13.6 18.2 22.7 31.8 45.4 TABLE 3: PROCEDURE FOR SIZING GREASE INTERCEPTORS (Metric Equivalents Omitted for simplicity) Steps Formula Example 1 2 3 4 5 TABLE 5 Determine cubic content of fixture by multiplying length X Width X depth. Determine capacity in gallons. 1 gal. = 231 cubic inches Determine actual drainage load. The fixture is normally filled to about 75 % of capacity with water. The items being washed displace about 25 % of the fixture content, thus actual drainage load = 75% of fixture capacity Determine flow rate and drainage period. In general, good practices dictate a one(1) minute drainage period; however, where conditions permit, a two (2) minute drainage period is acceptable. Drainage period is the actual time required to completely drain the fixture. Flow rate = Actual Drainage Load Drainage Period Select interceptor. From Table 2 select interceptor which corresponds to the flow rate calculated. Note: Select next larger size when flow rate falls between two sizes listed. TABLE 4: SELECTION CHART (Metric Equivalents Omitted for Simplicity) Fixture Compartment Sizes (Inches) A sink 48 long by 24 wide by 12 deep. Cubic content 48 X 24 X 12=13,824 cubic inches Contents in gallons 13,824/231 = 59.8 gallons Actual drainage load.75 X 59.8 = 44.9 gallons Calculate flow rate for one-minute period 44.9/1 = 44.9 GPM Flow Rate Two-minute period 44.9/2 = 22.5 GPM Flow Rate For one-minute period - 44.9 GPM requires PDI size 50 For two-minute period - 22.5 GPM requires PDI size 25 18 X 12 X 6 1 4.2 7 4 16 X 14 X 8 1 5.8 7 4 20 X 18 X 8 1 9.4 10 7 18 X 16 X 8 2 15.0 15 10 20 X 18 X 8 2 18.7 20 10 30 X 20 X 8 1 15.5 20 10 24 X 20 X 12 1 18.7 20 10 22 X 20 X 8 2 23.0 25 15 22 X 20 X 12 2 34.0 36 20 24 X 24 X 12 2 44.9 50 25 Fixture Outlet or Trap Size (Inches) 1-1/4 1 7.5 10 1-1/2 2 15.0 15 2 3 22.0 25 2-1/2 4 30.0 35 3 5 37.5 50 4 6 45.0 50 5 No. of Compartments Drainage Fixture- Unit Value Drainage Load (Gallons) GPM Equivalent Recommended PDI Size Grease Interceptor One-Minute Drainage Period Two-Minute Drainage Period PDI Size Grease Interceptor SIZING INTERCEPTORS ACCORDING TO PDI STANDARD PDI-G101 The recommendations for sizing, installation and maintenance of grease interceptors contained in this section are based on experience of the industry and were taken from PDI-G101. Sizing Considerations A grease interceptor conforming to Standard PDI-G101 is designed and certified to operate efficiently at its rated capacity. The larger the interceptor the higher the flow rate it will handle efficiently with a greater quantity of grease retained before cleaning is required. While a small interceptor, undersized, can accommodate a flow of waste water well in excess of its rated capacity, it will not intercept grease efficiently under such overload conditions. Fixture drainage period, in combination with the service required and the quantity of waste water involved, establishes the rate of flow through the grease interceptor. Flow rate is therefore the primary gauge which establishes interceptor size or capacity. The link between flow rate and drainage load to produce satisfactory grease interceptor operation is a Flow Control Fitting. Without it, a correctly sized grease interceptor will not regulate the flow of water discharged from the fixture it is serving. Therefore, to ensure that the flow rate does not exceed the grease interceptor s rated capacity, a flow control fitting is essential for protection against overloading the grease interceptor which could occur from sudden surges from the fixture. The flow control fitting will control the flow of waste water at all times, enabling the interceptor to operate at its certified capacity. Size Symbols It has been determined through the testing and rating procedure that eight (8) different sized grease interceptors are required for normal domestic, commercial, and institutional installations. These sizes are based on certification standard flow rates and grease retention capacity ratings for grease interceptors, see Table 1. Table 2 lists the PDI size symbol for each of the standard rated grease interceptors. Sizing Procedure Table 3 is provided to show the standard formula in steps for sizing grease interceptors to suit requirements of specific fixtures. Selection Table 4 is included as a selection chart for standard PDI Certified grease interceptors applicable to various size fixtures commonly used in domestic, commercial and institutional installations. The selections listed are based on the sizing formula covered in Table 3. Dishwashers A separate grease interceptor is recommended for each commercial dishwasher. The size of the interceptor is determined by the GPM discharge rate of the dishwasher. Select proper interceptor of equivalent or next higher rate from Table 2. Multiple Fixtures When multiple fixtures are served by a single interceptor, calculate the total capacity of all fixtures, establish the maximum number of fixtures that may be drained simultaneously and apply this factor to the total capacity to determine the maximum simultaneous capacity. Then proceed with sizing and selection of interceptor using sizing formula, Table 3. Alternate Sizing Method Based on Drainage Fixture-Units Most plumbing codes list drainage Fixture- Unit values for plumbing fixtures and for fixtures not listed, these values are given for drain outlet or trap size. Fixture-Unit values are converted to discharge rates on the basis of one Fixture-Unit equaling 7.5 GPM. See Table 5 for recommended PDI size grease interceptor based on drainage Fixture-Unit sizing method. TABLE 1: CERTIFICATION STANDARD FLOW RATES AND GREASE RETENTION CAPACITY RATINGS FOR GREASE INTERCEPTORS Flow Rate (GPM) (L/s) Grease Retention Capacity Rating Recommended Maximum Capacity of Fixtures Connected Connected to Interceptors (Pounds) (kg) (Gallons) (L) For Small 4 0.25 8 3.6 10.0 37.9 Domestic Use 7 0.44 14 6.4 17.5 66.2 10 0.63 20 9.1 25.0 94.6 For Large 15 0.95 30 13.6 37.5 141.9 Domestic, 20 1.26 40 18.2 50.0 189.3 Commercial, and 25 1.58 50 22.7 62.5 236.6 Institutional Use 35 2.20 70 31.8 87.5 331.2 50 3.16 100 45.4 125.0 473.1

Guide to Interception Contact your local representative Traditional G.I. Semi-Automatic Draw-off G.I. Custom Made, Special Quote, Interceptors SMITH CUSTOMER DRIVEN JAY R. SMITH MFG. CO. DIVISION OF SMITH INDUSTRIES, INC. POST OFFICE BOX 3237 MONTGOMERY, ALABAMA 36109-0237 (USA) TEL: 334-277-8520 FAX: 334-272-7396 www.jrsmith.com ASPE MEMBER OF: