WASTE ACCEPTANCE PROTOCOLS FOR THE PROVINCES OF



Similar documents
HAZARDOUS AND NONHAZARDOUS OIL AND GAS WASTE

Hazardous Waste Containers. Hazardous Waste Disposal. Examples of HW Containers. Typical Wastes in Chemistry

XI (a). WASTE DISPOSAL -- CHEMICAL WASTE

RAILROAD COMMISSION OF TEXAS APPENDIX C LIST OF E&P WASTES: EXEMPT AND NONEXEMPT

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing

EMERGENCY PETROLEUM SPILL WASTE MANAGEMENT GUIDANCE. Hazardous Materials and Waste Management Division (303)

GUIDANCE NOTES FOR WASTE MANAGEMENT

F The following spent

Identifying Your Hazardous Waste

Environmental Forensics

Water Analysis Report Report Date: March 31, 2012 Testing Period: 1st - 4th Quarter 2011

The purpose of this bid is to procure a contract with a laboratory to provide analytical testing services on an as-needed basis.

7. Chemical Waste Disposal Procedures

San Mateo County Environmental Health Characterization and Reuse of Petroleum Hydrocarbon Impacted Soil

IDENTIFYING YOUR WASTE

To meet our acceptance criteria, we may require you to partially treat your wastewater before it discharges to sewer.

Waste that must be tracked

Industrial Solid Waste Management Plan (ISWMP)

TERRA TEK LIMITED GUIDE TO SAMPLE HANDLING. Version 1.06

LETTER FROM U S NAVY REGARDING RESEARCH, DEVELOPMENT, AND DEMONSTRATION PROJECT NCBC GULFPORT MS 8/12/1986 U S NAVY

LED Life-Cycle Assessment & Environmental Testing

Soil, Ground Water and Sediment Standards for Use Under Part XV.1 of the Environmental Protection Act Ministry of the Environment April 15, 2011

Here are some hazardous wastes commonly generated by the marina industry:

CHAPTER SOIL TREATMENT FACILITIES

Guidelines on Resource Recovery Exemptions (Land Application of Waste Materials as Fill)

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

CHAPTER 2 HAZARDOUS OIL AND GAS WASTE DETERMINATION

Texas Commission on Environmental Quality

Training Module. Hazardous Waste Identification (40 CFR Parts 261) Introduction to. Solid Waste and Emergency Response (5305W) EPA530-K

HAZARDOUS CHEMICAL WASTE DISPOSAL SECTION 7

Managing Automotive Repair And Body Shop Wastes

Managing Floor Drains and Flammable Traps

VENTURA COUNTY AIR POLLUTION CONTROL DISTRICT 669 County Square Drive, Ventura CA / FAX 805/

Waste. Guidelines. EPA 842/09: This guideline provides definitions for a range of terms commonly used within the waste industry.

PROCEDURES FOR LABORATORY CHEMICAL WASTE DISPOSAL

Environmental Technology March/April 1998

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. I - Types, Amounts and Effects of Industrial Solid Wastes - Jinhui Li

G U I D E L I N E S C L A S S I F I C A T I O N C O D I N G I N D U S T R I A L

Pollution Liability Exposure: Adjustments your automotive business should consider to maintain compliance

Ingrid Hewitson Air Pollution Control Division November 13, /12/2014 WCRAQC November 2014 DERA Presentation

The 2015 Annual Report on Violations of the U.S. and Florida Safe Drinking Water Acts in the State of Florida

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Ordinance pertaining to the recovery of waste at surface landfills (Deponieverwertungsverordnung DepVerwV) *) of 25 July 2005.

Produced water from oil and gas production

INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS

Terms Used in the following Tables 1 3

Hazardous Waste Procedures. Faculty of Science University of Ottawa

Characterizing Beauty Salon Wastewater for the Purpose of Regulating Onsite Disposal Systems

BOTTLED WATER QUALITY REPORT INTRODUCTION VOSS SOURCE SPECIFIC MINERAL ANALYSIS. VOSS Still. VOSS Sparkling. General Mineral Analysis

Managing Auto Repair & Body Shop Wastes

Hazardous Materials Handling and Disposal Policy and Procedures

Sampling Techniques to Ensure Quality Results. David Springer ACLCA Adelaide June 2013

Oxidizer(s) Management and Use Guidelines

Waste and Cost Reduction Techniques for Small Parts Cleaners

Welcome to NOAH and Langøya!

Advantages and Disadvantages of Low VOC Vegetable Based Metalworking Fluids

Handling of Specific Chemicals

PROTOCOL NO. 5: Petroleum Hydrocarbon Analytical Methods and Standards

BECHTEL JACOBS COMPANY ORR WASTE CERTIFICATION PROGRAM DOCUMENT CONTROL SYSTEM

WASTE STREAM 2Y51 Analytical Services Process Facilities - North Labs

TORONTO MUNICIPAL CODE CHAPTER 423, ENVIRONMENTAL REPORTING AND DISCLOSURE. Chapter 423 ENVIRONMENTAL REPORTING AND DISCLOSURE

South Dakota s Statewide Ground Water Quality Monitoring Network

Hazardous Waste Management & Waste Minimization Training

Unit A: Studying Materials Scientifically

Purity of water is defined in part by the mineral level found in specific bottled waters and is referred to as

Hazardous Waste Compliance Awareness For Faculty and Staff

INSTRUCTIONS FOR THE COLLECTION OF HAZARDOUS WASTE IN BIOCENTER OULU LABORATORIES

Hazardous Waste In New Zealand

Acrylonitrile Acetylaminofluorene Aminodiphenyl Arsenic 1

Industry Description and Practices. Waste Characteristics

EOC Quality Through Compliance. Policies and Procedures. HAWAII HEALTH SYSTEMS C O R P O R A T I O N Touching Lives Everyday" N/A

POTENTIAL TO EMIT SUMMARY FIBERIGHT, LLC HAMPDEN, MAINE

Fact Sheet: Disposal of Alkaline Batteries

Impact of utilised bottom ash

56 TOLEDO STREET, FARMINGDALE, NY P: F:

Policies and Procedures Manual Waste Management Plan Policy No. 06:04:00 Page 1 of 12

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

2013 Rhode Island Pollutant Discharge Elimination System Remediation General Permit

WasteTRACK - The New Zealand Waste Tracking System. Information and Tutorial

Waste Management Program

Ontario Drinking Water Parameter Limits and Descriptions

Diseases caused by toxic halogen derivatives of aliphatic or aromatic hydrocarbons

Queen s University Environmental Health & Safety

Response from EMR to outstanding questions from the Select Committee Regarding the Risks and Benefits of Hydraulic Fracturing January 2014

Guidance on applying the waste hierarchy to hazardous waste November 2011

The following sections provide hazardous waste safety guidelines and procedures. This section covers the following topics:

Secondary Lead Smelting

HAZARDOUS WASTE MANUAL For Faculty, Staff, and Students

Hazardous and Regulated Waste Management Plan Purpose

WHAT IS A HAZARDOUS WASTE? Kansas Department of Health and Environment Bureau of Waste Management

MITIGATION MONITORING PROGRAM (Accompanies the Van Nuys Fire Station 39 Initial Study/Mitigated Negative Declaration)

Land Application of Drilling Fluids: Landowner Considerations

OZONE SPARGE TECHNOLOGY FOR GROUNDWATER REMEDIATION. Charles R. Plummer, P.E., M.S., Michael D. Luckett, P.E., Shaun Porter, and Robert Moncrief

Removing Thallium from Industrial FGD Scrubber Water with Sorbster Adsorbent Media

Extraction Oil and Gas, LLC. Diamond Valley Central Oil Terminal Waste Management Plan

THE CORPORATION OF THE CITY OF MISSISSAUGA STORM SEWER BY-LAW ( amended by )

General Chemistry and Metals

Talinga Water Treatment Facility Discharge Water Quality Report

LOS ANGELES UNIFIED SCHOOL DISTRICT INDUSTRIAL WASTEWATER MANAGEMENT PROCEDURES

Treatment and Disposal Technologies for Medical Wastes in Developing Countries

Transcription:

WASTE ACCEPTANCE PROTOCOLS FOR THE PROVINCES OF BRITISH COLUMBIA ALBERTA SASKATCHEWAN

BRITISH COLUMBIA

BRITISH COLUMBIA SOLID WASTE ACCEPTANCE PROTOCOL BRITISH COLUMBIA This form will assist you in identifying if the waste(s) can be accepted and assist in the analytical testing requirements for each waste stream or type. Tervita Secure Landfills will accept solid hazardous waste (expect those prohibited) and non-hazardous industrial/oilfield solid wastes. EXAMPLES OF COMMON ACCEPTABLE SOLID WASTES (No Free Liquids) 1. Activated Carbon 2. Asbestos 3. Catalyst(s) Sulphur and Non-Sulphur 4. Cement (Crushed, Dry Returns) 5. Contaminated Debris and Soil(s) with: Chemical/Solvent(s) Crude Oil/Condensate Dry Cleaning/Industrial Related Mercury/Metals Methanol Produced/Salt Water Refined Fuel(s) (i.e. Gasoline) 6. Construction and Demolition (C&D) Debris 7. Desiccant(s)/Molecular Sieve(s) 8. Frac Sand (non-radioactive) 9. Incinerator Ash 10. Sand Produced 11. Sludge No Free Liquids (Solids ONLY) from: Hydrocarbon Lime Process Flare Pit 12. Drilling Mud/Cuttings: Advanced Gel Chem Gel Chem Invert (Diesel Fuel) Potassium Chloride (KCl) Potassium Sulphate (K 2 SO 4 ) 13. Treated Wood/Wood Waste (e.g. railway ties) 14. NORM (Naturally Occurring Radioactive Material) solid waste (Silverberry Landfill Only) BRITISH COLUMBIA Page 1 of 5

BRITISH COLUMBIA SOLID WASTE ACCEPTANCE PROTOCOL BRITISH COLUMBIA LANDFILL DISPOSAL CRITERIA The following is a list of landfill disposal criteria that may be required based on the description, origin and history of the solid waste: Analytical data provided must support the non-hazardous solid waste classification Analytical data provided must be current (not older than one (1) calendar year) It is the responsibility of the waste generator to determine the characteristics of the waste Un-used non-hazardous solid products require a SDS/Data Sheet PROHIBITED WASTES 1. Liquids (Paint Filter Test) 2. Wastes materials which contain free liquids 3. Wastes containing Benzene, Toluene, Ethylbenzene and/or Xylene(s) in total combined concentrations > 1,000.0 mg/kg (Total BTEX Analysis) 4. Containers holding free liquids 5. Lube oil filters (spin on/off) and containers covered under the BC Used Oil Management Association 6. Recyclable Oily Rags 7. Wastes containing halogenated organic compounds in total concentrations > 100.0 mg/kg (EOX Analysis), excluding tetrachlorethylene 8. Waste containing tetrachloroethylene in total concentrations > 500.0 mg/kg 9. Waste which contain dioxin TEQ, as defined by the Hazardous Waste Regulation, in a concentration greater than 100 parts per billion by weight 10. PCB Wastes 11. Wastes as defined by the Transportation of Dangerous Goods Regulations of Canada (TDG) (Transport Canada, 2011) which: Fall under TDG Classes 1 to 9 but excluding Class 4.1 UN 3175: Solids Containing Flammable Liquids Are listed as forbidden in Column 3 of Schedule 1. These are dangerous goods that must not be transported (some example substances are UN3097: Flammable Solids and UN3100: Oxidizing Solids) 12. Wastes as defined by the Hazardous Waste Regulation (Government of British Columbia, April 2009) which: contain any liquid or solid containing > 50 ppm by weight of chlorobiphenyls (PCB) contain dioxin TEQ in a concentration of > 100 ppb (dioxin TEQ is determined by adding the products of the measured concentrations of each congener listed in Schedule 1: Column 1 multiplied by the TEF in Column 2) contains one or more contaminates listed in Schedule 4: Table 1 with > than the concentration specified in Column 2 EXCEPT BTEX (when subjected to the Modified Leachate Extraction Procedure refer to Schedule 4: Part 2 Modified Leachate Extraction Procedure in the Hazardous Waste Regulation) BRITISH COLUMBIA Page 2 of 5

TERVITA BRITISH COLUMBIA INDUSTRIAL LANDFILL DISPOSAL CRITERIA BRITISH COLUMBIA The following associated regulatory levels are common compounds and the maximum allowable concentrations. Any material that exceeds these levels will not be approved for disposal. Refer to Schedule 4, Table 1 from the Hazardous Waste Regulation (Government of British Columbia, April 2009) for additional parameters. CONSTITUENTS BTEX: Total combined BTEX Benzene* Ethylbenzene* Toluene* Xylenes* REGULATORY LEVELS 1,000.0 mg/kg 0.5 mg/l 0.24 mg/l 2.4 mg/l 30.0 mg/l * Leachable BTEX levels classified as Hazardous Waste if > stated regulatory levels Halogenated Organic Compounds: EOX (Extractable Organic Halides) Tetrachloroethylene 100.0 mg/kg (total) 500.0 mg/kg Volatile Organic Compounds (VOCs): Discrete compound limits Other: Additionally, the waste must meet the following requirements: ph 2.0 and 12.5 (Except Wood Ash) No Free Liquids can be present (US EPA Method 9505 Paint Filter Liquids Test) CONSTITUENTS Common Leachable Substances: Arsenic Barium Boron Cadmium Chromium Cyanide Copper Fluorides Lead Mercury Nitrate Nitrite Selenium Silver Uranium Zinc PCBs: NORM Waste (Silverberry Only): REGULATORY LEVELS 2.5 mg/l 100.0 mg/l 500.0 mg/l 0.5 mg/l 5.0 mg/l 20.0 mg/l 100.0 mg/l 150.0 mg/l 5.0 mg/l 0.1 mg/l 4,500.0 mg/l 320.0 mg/l 1.0 mg/l 5.0 mg/l 10.0 mg/l 500.0 mg/l 50.0 mg/kg 70 Bq/g and Radium 226 at 5 Bq/g Note(s): Not all regulated compounds are listed. Refer to Schedule 4, Table 1 above from the Hazardous Waste Regulation (Government of British Columbia, April 2009) for additional parameters Waste containing elemental sulphur and sulphides 500.0 mg/kg is deemed Sulphur Waste (S-Waste). Refer to the Guidelines for Landfill Disposal of Sulphur Waste and Remediation of Sulphur Containing Soils (AEP, September 12, 2011) Dry Cleaner and/or other Industrial related impacted solids may require specific analytical parameters; please contact Tervita for full details BRITISH COLUMBIA Page 3 of 5

TERVITA BRITISH COLUMBIA INDUSTRIAL LANDFILL DISPOSAL CRITERIA BRITISH COLUMBIA BASIC PARAMETERS The following BASIC analytical testing is required for all wastes regardless of the composition: FP Flash point for solid samples ph ph of solid waste material TBTEX Total Benzene, Ethylbenzene, Toluene and Xylene(s) LBTEX Leachable Benzene, Ethylbenzene, Toluene and Xylene(s) (TCLP and/or MLEP) LMETALS Leachable Metals (TCLP and/or MLEP) LMERCURY - Leachable Mercury (TCLP and/or MLEP) PFT Paint Filter Test ANALYTICAL REQUIREMENTS: SUPPLEMENTAL WASTE SPECIFIC PARAMETERS The following additional analysis MAY be required depending on the waste description and/or type (refer to guidance below). Additional analysis may be requested depending on the type of waste and source of generation. Sol Scan Landfill Solvent Screen in solid waste EPA 8240 PCB Polychlorinated Biphenyls PAH Polycyclic Aromatic Hydrocarbons EOX Extractable Halogenated Organic Compounds (TCLP and/or MLEP) VOC Volatile Organic Compounds (TCLP and/or MLEP) Waste Oil Means automotive lubrication oil, cutting oil, fuel oil, gear oil, hydraulic oil and any other refined petroleum based oil or synthetic oil, including diesel fuel where the oils in the waste in a total concentration greater than 3% by weight and the oils through use, storage or handling have become unsuitable for the original purpose due to the presence of impurities or loss or original properties (if the total concentration of oil in waste is > 3% by weight, the waste is considered waste oil and falls under the definition for hazardous waste) Spontaneous Combustion (Self-Heating) Sulphur Elemental Sulphur (S 0 ) and Sulphides (S 2- ) Water Reactivity (ΔT) % ANC % Acid Neutralizing Capacity Additional testing recommended for Sulphur impacted wastes % CCE % Calcium Carbonate Equivalent Additional testing recommended for Sulphur impacted wastes The following analyses are used to aid in the determination of the waste classification: 1. FP Flash Point for solid samples (solids with a flash point < to 60.5ºC using the closed-cup test method are considered flammable, fall under the category TDG Class 4.1 UN3175 Solids Containing Flammable Liquids, are acceptable at the Silverberry and Northern Rockies landfill). 2. Leachable Toxic Waste Means waste when subjected to the extraction procedure described in the US EPA Method 1311 produces an extract with a contaminant concentration greater than those prescribed in Table 1 of Schedule 4 of the Hazardous Waste Regulations. 3. Waste Oil Determination of Waste Oil Content in Solids and Liquids for HWR PBM (March 31,2005) 4. Modified Leachate Extraction Procedure (MLEP) Method used to determine suitability for waste disposal in a Secure landfill, see Schedule 4 Part 2 of the Hazardous Waste Regulation. BRITISH COLUMBIA Page 4 of 5

WASTE SPECIFIC ANALYTICAL REQUIREMENTS BRITISH COLUMBIA WASTE DECRIPTION ANALYTICAL REQUIREMENTS 1. Activated Carbon and Spontaneous Combustion (Self-Heating)* 2. Cement (crushed, returns dry) or Completion Cement SDS (if available) 3. Catalyst (sulphur), Elemental Sulphur and Sulphides, Spontaneous Combustion (Self-Heating)* and SDS (if available) 4. Catalyst (non-sulphur), Spontaneous Combustion (Self-Heating)* and SDS (if available) 5. Contaminated debris and soil with: Chemical/Solvent(s) Refined Oil(s) Diesel Fuel Crude Oil/Condensate Mercury/Metals Methanol Produced/Salt Water Industrial Chemicals/Dry Cleaner, Waste Oil, Sol Scan*, VOC s* and SDS (if available) and Waste Oil and Waste Oil, Elemental Sulphur and Sulphides and Additional Analysis* 6. Desiccant(s)/Molecular Sieve(s), Water Reactivity (ΔT)* and SDS (if available) 7. Sand - Produced 8. Incinerator Ash 9. Sludge - No free liquids (Solids ONLY) from: Flare Pit, Waste Oil, Sol Scan*, PAH*, PCB*, and EOX* Hydrocarbon Lime Process and Sol Scan*, Elemental Sulphur and Sulphides Refined Oil(s) and Waste Oil 10. Gel Chem Drill Mud/Cuttings 11. Advanced Gel Chem Drill Mud/Cuttings 12. Invert Drill Mud/Cuttings and Waste Oil 13. NORM Solids Radiochemistry (Bq/g) * Please contact the Facility Manager to discuss the requirements of these parameters. Note: The analytical requirements for waste approval include but are not limited to those listed above. Tervita may request additional testing prior to issuing approval. If a waste differs from the descriptions above please contact the Tervita facility. HELPFUL INFORMATION (Laboratory Requirements) Spontaneous combustion testing requires a four (4) liter pail of sample. BTEX sampling requires methanol preservation, EPA 5035A. Analytical reports must be the signed copy. BRITISH COLUMBIA Page 5 of 5

ALBERTA

ALBERTA SOLID WASTE ACCEPTANCE PROTOCOL ALBERTA This form will assist you in identifying if the waste(s) can be accepted and assist in the analytical testing requirements for each waste stream or type. Tervita Class II Landfills will only accept solid, non-dangerous oilfield and non-hazardous industrial wastes. EXAMPLES OF COMMON ACCEPTABLE SOLID WASTES (No Free Liquids) 1. Activated Carbon 2. Asbestos 3. Catalyst(s) Sulphur and Non-Sulphur 4. Cement (Crushed, Dry Returns) 5. Contaminated Debris and Soil(s) with: Chemical/Solvent(s) Crude Oil/Condensate Dry Cleaning/Industrial Related Mercury/Metals Methanol Produced/Salt Water Refined Fuel(s) (i.e. Gasoline) 6. Construction and Demolition (C&D) Debris 7. Desiccant(s)/Molecular Sieve(s) 8. Drilling Mud(s)/Cuttings: Advanced Gel Chem Gel Chem Invert Potassium Chloride (KCl) Potassium Sulphate (K 2 SO 4 ) 9. Frac Sand (non-radioactive) 10. Incinerator Ash 11. Sand - Produced 12. Sludge - No Free Liquids (Solids ONLY) from: Flare Pit Hydrocarbon Lime Process 13. Treated Wood/Wood Waste (e.g. railway ties) ALBERTA Page 1 of 5

ALBERTA SOLID WASTE ACCEPTANCE PROTOCOL ALBERTA PROHIBITED WASTES 1. Free Liquids 2. Hazardous Solid Waste as defined in: The Waste Control Regulation (Government of Alberta, 1996) The Alberta User Guide for Waste Managers (AEP, August 1996) 3. Radioactive Material 4. Reactive Material 5. Explosives 6. Biological and/or Bio-Medical Waste 7. Ozone Depleting Substances LANDFILL DISPOSAL CRITERIA The following is a list of landfill disposal criteria that may be required based on the description, origin and history of the solid waste: Analytical data provided must support the non-hazardous solid waste classification Analytical data provided must be current (not older than one (1) calendar year) It is the responsibility of the waste generator to determine the characteristics of the waste Un-used non-hazardous solid products require a SDS/Data Sheet ALBERTA Page 2 of 5

TERVITA ALBERTA CLASS II INDUSTRIAL LANDFILL DISPOSAL CRITERIA ALBERTA The following lists of common compounds are found in Table 2 of the Alberta Users Guide for Waste Managers (AEP, August 1996). The associated regulatory levels are the maximum allowable concentrations. Any material that exceeds these levels will not be approved for disposal at the Tervita Class II Landfill. Note: Refer to the Class II Industrial Landfill Analytical Requirements following this page for the specific analytical required based on the waste stream description. CONSTITUENTS REGULATORY CONSTITUENTS REGULATORY Leachable/Total BTEX: Solvent Scan: Benzene 0.5 mg/l Total cresol 200.0 mg/l Toluene 0.5 mg/l Methyl ethyl ketone 200.0 mg/l Ethylbenzene 0.5 mg/l Nitrobenzene 2.0 mg/l Xylenes 0.5 mg/l Pyridine 5.0 mg/l Extractable halogenated organic compounds (EOX): Volatile organic compounds (VOCs): 1,000.0 mg/kg (total) Discrete compound limits Leachable Metals: PAHs: Antimony 500.0 mg/l Napthalene 0.50 mg/l Arsenic 5.0 mg/l Barium 100.0 mg/l PCBs: Beryllium 5.0 mg/l PCB 50.0 mg/kg (Total) Boron 500.0 mg/l Cadmium 1.0 mg/l Methanol Flash Point > 60.5 C Chromium 5.0 mg/l Cobalt 100.0 mg/l Other: Copper 100.0 mg/l Additionally, the waste must meet all the Iron 1,000.0 mg/l following requirements: Lead 5.0 mg/l ph 2.0 and 12.5 Mercury 0.2 mg/l Flash Point > 60.5 C (Degrees Celsius) Nickel 5.0 mg/l No Free Liquids can be present Selenium 1.0 mg/l (US EPA Method 9505 Paint Filter Liquids Test) Silver 5.0 mg/l Thallium 5.0 mg/l Uranium 2.0 mg/l Vanadium 100.0 mg/l Zinc 500.0 mg/l Zirconium 500.0 mg/l Note(s): Not all regulated compounds are listed above. Refer to the Alberta Users Guide for Waste Managers (AEP, August 1996) for the complete list Dry cleaner and/or other industrial related impacted solids may require specific analytical parameters; please contact Tervita for full details Waste containing elemental Sulphur and Sulphides 500.0 mg/kg is deemed Sulphur Waste (S-Waste). Refer to the Guidelines for Landfill Disposal of Sulphur Waste and Remediation of Sulphur Containing Soils (AEP, September 12, 2011) Refer to Table 2.0 of the Alberta Users Guide for Waste Managers (AEP, August 1996) for Halogenated Organic Compounds discrete compound regulatory limits in addition to the 1,000.0 mg/kg total. ALBERTA Page 3 of 5

TERVITA ALBERTA INDUSTRIAL LANDFILL ANALYTICAL REQUIREMENTS ALBERTA BASIC PARAMETERS The following BASIC analytical testing is required for all wastes regardless of the composition: FP Flash point for solid samples ph ph of solid waste material LBTEX Leachable BTEX (TCLP) LMETALS Leachable metals (TCLP) PFT Paint Filter Test SUPPLEMENTAL WASTE SPECIFIC PARAMETERS The following additional analysis MAY be required depending on the waste description and/or type (refer to guidance below). Additional analysis may be requested depending on the type of waste and source of generation. Sol Scan Landfill Solvent Screen in solid waste EPA 8240 PCB Polychlorinated Biphenyls PAH Polycyclic Aromatic Hydrocarbons EOX Extractable Halogenated Organic Compounds (TCLP) VOC Volatile Organic Compounds (TCLP) Spontaneous Combustion (Self-Heating) Sulphur Elemental Sulphur (S 0 ) and Sulphides (S 2- ) Water Reactivity (ΔT) % ANC % Acid Neutralizing Capacity Additional testing recommended for Sulphur impacted wastes % CCE % Calcium Carbonate Equivalent Additional testing recommended for Sulphur impacted wastes ALBERTA Page 4 of 5

WASTE SPECIFIC ANALYTICAL REQUIREMENTS ALBERTA WASTE DECRIPTION ANALYTICAL REQUIREMENTS 1. Activated Carbon and Spontaneous Combustion (Self-Heating)* 2. Cement (non-contaminated crushed, dry returns) Completion Cement, SDS (if available) 3. Catalyst (sulphur), Elemental Sulphur and Sulphides, Spontaneous Combustion* and SDS (if available) 4. Catalyst (non-sulphur), Spontaneous Combustion* and SDS (if available) 5. Desiccant(s)/Molecular Sieve(s), Water Reactivity (ΔT)* and SDS (if available) 6. Contaminated debris and soil with: Chemical/Solvent Methanol Crude Oil/Condensate Refined Fuel(s) Mercury/Metals Produced/Salt Water Industrial Chemicals/Dry Cleaner 7. Frac sand (non-radioactive) 8. Incinerator ash 9. Sand produced 10. Sludge no free liquids (solids only) from: Flare pit Hydrocarbon Lime Process, Sol Scan* and SDS (if available), Elemental Sulphur and Sulphides and Additional Analysis*, Sol Scan*, PAH*, PCB* and EOX* and Sol Scan*, Elemental Sulphur and Sulphides 11. Drill mud/cuttings *Please contact the Facility Manager to discuss the requirements of these parameters. Note: The analytical requirements for waste approval include but are not limited to those listed above. Tervita may request additional testing prior to issuing approval. If a waste differs from the descriptions above please contact the Tervita facility. HELPFUL INFORMATION (Laboratory Requirements) Spontaneous combustion testing requires a four (4) liter pail of sample. BTEX sampling requires a 500 ml glass jar with no head space. Analytical reports must be the signed copy. ALBERTA Page 5 of 5

SASKATCHEWAN

SASKATCHEWAN SOLID WASTE ACCEPTANCE PROTOCOL SASKATCHEWAN This form will assist you in identifying if the waste(s) can be accepted and assist in the analytical testing requirements for each waste stream or type. Tervita Industrial Landfills will only accept solid, non-dangerous oilfield and non-hazardous industrial wastes. EXAMPLES OF COMMON ACCEPTABLE SOLID WASTES (No Free Liquids) 1. Activated Carbon 2. Asbestos 3. Catalyst(s) Sulphur and Non-Sulphur 4. Cement (Crushed, Dry Returns) 5. Contaminated Debris and Soil(s) with: Chemical/Solvent(s) Crude Oil/Condensate Dry Cleaning/Industrial Related Mercury/Metals Methanol Produced/Salt Water Refined Fuel(s) (i.e. Gasoline) 6. Construction and Demolition (C&D) Debris 7. Desiccant(s)/Molecular Sieve(s) 8. Drilling Mud(s)/Cuttings: Advanced Gel Chem Gel Chem Invert Potassium Chloride (KCl) Potassium Sulphate (K 2 SO 4 ) 9. Frac Sand (non-radioactive) 10. Incinerator Ash 11. Sand - Produced 12. Sludge - No Free Liquids (Solids ONLY) from: Flare pit Hydrocarbon Lime Process 13. Treated Wood/Wood Waste (e.g. railway ties) 14. Treatable Solid Waste (Hydrocarbon impacted, Refined fuel impacted solids) (Lomond Treatment Pad ONLY) SASKATCHEWAN Page 1 of 5

SASKATCHEWAN SOLID WASTE ACCEPTANCE PROTOCOL SASKATCHEWAN PROHIBITED WASTES 1. Free Liquids 2. Hazardous Solid Waste as defined in: Transportation of Dangerous Goods Regulations (Transport Canada, 2011) Appendix B of the specific Tervita Saskatchewan Landfill Approval(s) 3. Municipal Solid Waste (MSW) 4. Radioactive Material 5. Medical or Bio-medical Waste 6. Putrescible Waste (e.g. animal carcasses) 7. Waste containing distillate invert mud systems with oxygen scavengers 8. Large metal objects (e.g. automobiles/white goods) 9. Explosives 10. Reactive Material LANDFILL DISPOSAL CRITERIA The following is a list of landfill disposal criteria that may be required based on the description, origin and history of the solid waste: Analytical data provided must support the non-hazardous solid waste classification Analytical data provided must be current (not older than one (1) calendar year) It is the responsibility of the waste generator to determine the characteristics of the waste Un-used non-hazardous solid products require a SDS/Data Sheet SASKATCHEWAN Page 2 of 5

TERVITA SASKATCHEWAN CLASS II INDUSTRIAL LANDFILL DISPOSAL CRITERIA SASKATCHEWAN The following list of common compounds and associated regulatory levels are the maximum allowable concentrations for solid waste that can be accepted at Tervita Saskatchewan Industrial Landfills. Any material that exceeds these limits will not be approved for disposal. Note: Refer to the TERVITA SASKATCHEWAN INDUSTRIAL LANDFILL ANALYTICAL REQUIREMENTS following this page for the specific analysis required based on the waste stream description and Appendix B of the Landfill Approval for additional acceptance criteria. CONSTITUENTS REGULATORY CONSTITUENTS REGULATORY Leachable/Total BTEX: PAHs: Benzene 0.5 mg/l Benzo(a)pyrene 0.001 mg/l Toluene 100.0 mg/kg Naphthalene 100.0 mg/kg Ethylbenzene 100.0 mg/kg PCBs: Xylenes 100.0 mg/kg PCB 50.0 mg/kg (Total) Leachable Metals: EOXs: Arsenic 2.5 mg/l 1,2 Dichlorobenzene 20.0 mg/l Barium 100.0 mg/l 1,4 Dichlorobenzene 0.5 mg/l Boron 500.0 mg/l Hexachlorobenzene 0.13 mg/l Cadmium 0.5 mg/l Hexachlorobutadiene 0.5 mg/l Chromium 5.0 mg/l Hexachloroethane 3.0 mg/l Lead 5.0 mg/l Hexachlorocyclopentadiene 100.0 mg/kg Mercury Selenium Uranium Solvent Scan: Carbon disulphide 0.1 mg/l 1.0 mg/l 10.0 mg/l 100.0 mg/kg Other Additionally, the waste must meet all the following requirements: Cresols 200.0 mg/l ph 2.0 and 12.5 Nitrobenzene 2.0 mg/l Flash Point > 60.5 C (degrees Celsius) Pyridine 5.0 mg/l No Free Liquids can be present (US EPA Ethyl methyl ketone 200.0 mg/l Method 9505 Paint Filter Liquids Test) Volatile Organic Compounds (VOCs): Discrete compound limits Note(s): Not all regulated compounds are listed above. Please refer to the Transportation of Dangerous Goods Regulations (Transport Canada, 2011) and Appendix B of the specific Tervita Saskatchewan Landfill approval(s) for a complete list of analytical requirements Waste containing elemental sulphur and sulphides 500.0 mg/kg is deemed Sulphur Waste (S-Waste). Refer to the Guidelines for Landfill Disposal of Sulphur Waste and Remediation of Sulphur Containing Soils (AEP, September 12, 2011) Dry Cleaner and/or other Industrial related impacted solids may require specific analytical parameters; please contact Tervita for full details SASKATCHEWAN Page 3 of 5

TERVITA SASKATCHEWAN INDUSTRIAL LANDFILL ANALYTICAL REQUIREMENTS SASKATCHEWAN BASIC PARAMETERS The following BASIC analytical testing is required for all wastes regardless of the composition: FP Flash Point for solid samples LB Leachable Benzene (TCLP) TTEX Total Toluene, Ethylbenzene and Xylene(s) (mg/kg) LMETALS Leachable metals (TCLP) ph ph of solid waste material PFT Paint Filter Test SUPPLEMENTAL WASTE SPECIFIC PARAMETERS The following additional analysis MAY be required depending on the waste description and/or type (refer to guidance below). Additional analysis may be requested depending on the type of waste and source of generation. EOX Extractable Organic Halides (by Neutron Activation) in soil or sludge (TCLP) VOC Volatile Organic Compounds (TCLP) Sol Scan Landfill Solvent Screen in solid waste EPA 8240 PAH Polycyclic Aromatic Hydrocarbons PCB Polychlorinated Biphenyls Spontaneous Combustion (Self-Heating) Sulphur Elemental Sulphur (S 0 ) and Sulphides (S 2- ) Water Reactivity (ΔT) % ANC % Acid Neutralizing Capacity Additional testing recommended for Sulphur impacted wastes % CCE % Calcium Carbonate Equivalent Additional testing recommended for Sulphur impacted wastes SASKATCHEWAN Page 4 of 5

WASTE SPECIFIC ANALYTICAL REQUIREMENTS SASKATCHEWAN WASTE DECRIPTION ANALYTICAL REQUIREMENTS 1. Activated Carbon and Spontaneous Combustion (Self- Heating)* 2. Cement (non-contaminated, crushed, dry returns) Completion Cement, SDS (if available) 3. Contaminated debris and soil with: Chemical/Solvent Refined Fuel(s) Crude Oil/Condensate Mercury/Metals Methanol Produced/Salt Water Industrial Chemicals / Dry Cleaners, Sol Scan* and SDS (if available), Elemental Sulphur and Sulphides and Additional Analysis* 4. Catalyst (sulphur), Elemental Sulphur and Sulphides, Spontaneous Combustion (Self-Heating)* and SDS (if available) 5. Catalyst (non-sulphur), Spontaneous Combustion (Self-Heating)* and SDS (if available) 6. Desiccant(s)/Molecular Sieve(s), Water Reactivity (ΔT)* and SDS (if available) 7. Frac Sand (non-radioactive) 8. Incinerator Ash 9. Sand Produced 10. Sludge no free liquids (solids only) from: Flare Pit Hydrocarbon Lime Process Industrial Chemicals/Dry Cleaner 11. Drill Mud/Cuttings, Sol Scan*, PAH*, PCB* and EOX* and Sol Scan*, Elemental Sulphur and Sulphides and Additional Analysis* *Please contact the Facility Manager to discuss the requirements of these parameters. Note: The analytical requirements for waste approval include but are not limited to those listed above. Tervita may request additional testing prior to issuing approval. If a waste differs from the descriptions above please contact the Tervita facility. HELPFUL INFORMATION (Laboratory Requirements) Spontaneous combustion testing requires a four (4) litre pail of sample. BTEX sampling requires a 500 ml glass jar with no head space. Analytical reports must be the signed copy. SASKATCHEWAN Page 5 of 5