Instruction Guide for Cleaning, Testing, and Packaging Kendall SCD 700 Sequential Compression System Controller and Tubing Set



Similar documents
Technical Update TAA.TU Rev. 1

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Your safety and the safety of others are very important.

Replacing the Gateway M675 Keyboard

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

PC1131 Electric Air Compressor

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

SCION FR-S PERFORMANCE AIR INTAKE Preparation 2.0L F-4

M-9000-ZX3 JRSC Focus Big Boost Upgrade Kit INSTALLATION INSTRUCTIONS

Quality Assurance Provisions

PC1130 Electric Air Compressor

P3000 Printer Guide Rev A. January 2006

Fan, Cypress / GreenField Installation Instructions (sku )

Guide To Returning Your Satellite Modem and Radio Assembly Model: HN7000S


UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

How To Replace A Reverse Osmosis Water Tank

Model 1756 Test Lead Kit

tire inflator with pressure gauge

GPS AutoSteer System Installation Manual

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

1 Global Warranty Service Agent Guide. Service Agent Help Guide. Service Agent Starts the Claim

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Model 349KLX Remote Display Digital Scale User Instructions

TM Advanced Tracking Technologies, Inc ATTI All rights reserved

81000 Series Aluminum Gate Valve Installation and Repair Manual

Impact Uni-Vent 750 Portable Ventilator

BroadBand PowerShield. User Manual

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

DRIVEABILITY MALFUNCTION INDICATOR LAMP

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

5800 Temperature Sensor Cable Assembly

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

Powers Controls TH 192 S Single Temperature Room Thermostat

INSTALLATION INSTRUCTIONS

Periodic Verification System Model 775PVS

Cable Tester Pro ORDERCODE D1909

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

DTC P0401, DTC P1491,

System Diagnosis. Proper vehicle diagnosis requires a plan before you start

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

High kw Electric Tankless Water Heater Troubleshooting Guide

Installation Instructions

HEAD HARNESS & BUCKELS

R-134A A/C SYSTEM REFRIGERANT DYE LEAK DETECTION

Ozone Generator Manual

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

GENUINE PARTS INSTALLATION INSTRUCTIONS

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, v1.0

Networkfleet 3500 Product Line Installation Guide

Written By: Walter Galan

LDG M-7700 External Meter for Icom IC-7700

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

A and M Electronics Contract Manufacturing Circuit Board Assembly Avenue Kearny Valencia, Ca (661) or (800)

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

Replacing the Gateway M320 Keyboard

1998½-2007 Dodge Ram 5.9L Cummins

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

DTA100. Digital Transport Adapter. Quick Start Guide. Downloaded from manuals search engine

OI Inventory Monitor Units

Lenovo Global Labeling Guide. Volume 6 FRU Package Labels. Lenovo Part Number 41U3002

Time Warner Cable TV. Easy Connect Guide. Enjoy endless ways to watch your favorite shows.

RCD Inspection Log Book

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

The Bose 601 TM Series IV Direct/Reflecting Speaker System

PREVENTATIVE MAINTENANCE

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

About the BitStorm 6051 POTS Splitter

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

4310/4320 Wireless Position Monitor

Instructions For SF 6 Refill Kit

FT-100 Fire Training Fog Machine User Manual English

Installation and Operation Guide PD4600 Series Converter Replacement

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS

Continuous ink supply system (CISS) For printer HP DeskJet 1280/9300/1120c/1180c/1200c

2013 VTech Printed in China US

QUICK REFERENCE. Connecting the Cables The power supply automatically switches between 115V and 230V.

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Universal Wireless Effects Controller USER S GUIDE SA115

How To Use A Power Supply Unit (Upu)

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Vendor Requirements and Compliances

ilan Ethernet Box for 9100 Installation Manual

MANUAL ENGLISH MHS-30S. Ordercode: D6544. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

MZ Series Overview. Introduction. (MZ 220 Illustrated)

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

Troubleshooting Guide

COMPRESSED AIR DRYER

2178-S Fiber Optic Splice Case

Transcription:

Instruction Guide for Cleaning, Testing, and Packaging Kendall SCD 700 Sequential Compression System Controller and Tubing Set

TABLE OF CONTENTS Section 1 Instructions for UNUSED Units 2 Confirm Kit Materials 2 Apply DME Label to Kendall SCD 700 Controller 2 Packaging Instructions 3 Section 2 Instructions for Customer Returned Units 5 Reference Documents 5 Equipment List 5 Preparation 5 Tubing Set: 7 Visual Inspection 7 Cleaning 7 Leak Test 7 Kendall SCD 700 Controller: 9 Visual Inspection 9 Cleaning 10 General Function Test 10 Re-Packaging Procedure: 11 Kit Materials 11 Packaging Instructions 11 Attachment A Instructions for Returning Damaged Controllers 13 1

Section 1 Instructions for UNUSED Units CONFIRM KIT MATERIALS Verify that all the following materials are available: Part Description Quantity Part # Vendor Contact Info New Kendall SCD 700 compression system 1 H29525 Covidien Return Label 1 N/A N/A N/A Twist Ties, Blue Plastic 1 F150023 Covidien Kendall SCD 700 controller QuickStart Guide 1 1066981 Covidien Kendall SCD 700 controller Printed IFU 1 1066980 Covidien APPLY DME LABEL TO KENDALL SCD 700 CONTROLLER Remove home controller from the packaging and take out of the polybag and AIR-PAQ * inflatable packaging. Create a label that provides the DME supplier contact information. At a minimum, the information should contain the following: Company name Company address Company telephone number Apply DME supplier contact information label on the front of the controller, approximately centered in the area indicated by the box in the sketch below (on the front of the controller, below the control panel): PLACE LABEL WITHIN THE BOXED AREA Place home controller back into the polybag and AIR-PAQ * inflatable packaging. Place the printed IFU into the shipping box. 2

Section 1 Instructions for UNUSED Units (continued) PACKAGING INSTRUCTIONS Re-package the home controller in the polybag and AIR-PAQ * inflatable packaging. Place the tubing sets into the original package the way it was received (see picture below). TUBING SET AIR-PAQ TM * INFLATABLE PACKAGING TUBING SET Place the QuickStart Guide on top of the AIR-PAQ TM * inflatable packaging as shown below: 3

Section 1 Instructions for UNUSED Units (continued) PACKAGING INSTRUCTIONS (continued) Seal the top of the box and confirm all labels are visible on the outside of the shipping box as shown below: o Serial label on the top of the shipping box; o Shipping label on the front wrapping on the left side; o Return label to the right of the shipper label and beneath the serial label. SERIAL LABEL SHIPPING LABEL RETURN LABEL 4

Section 2 Instructions for Customer Returned Units REFERENCE DOCUMENTS Kendall SCD 700 system Operation and Service Manual EQUIPMENT LIST Regulated air source (i.e. compressor or factory air) Tubing set Leak Test Fixture (provided by Covidien) Known good tubing set PREPARATION TUBING SET LEAK TEST FIXTURE SETUP: NOTE: This is to be performed upon receipt of the fixture, to confirm acceptable fixture functionality. o Confirm the tubing set Leak Test Fixture s certification from the fixture manufacturer. o Confirm pressure gauge is calibrated. If not, send out for re-calibration. o Conduct the leak test with the known good tubing set as follows: Ensure that the Leak Test Fixture (see sketch below) is connected to a regulated air source. The input air should be at pressure between 3 psi and 4 psi. CONNECT TO AIR Connect the tubing set to the connectors on the test fixture. See pictures below. 5

Section 2 Instructions for Customer Returned Units (continued) PREPARATION (continued) TUBING SET LEAK TEST (continued): Turn ball valve to open position, so that the knob position is in-line with valve body (see picture below). Adjust the input air pressure so that a pressure of between 125mmHg (2.4 psi) and 135mmHg (2.6 psi) is indicated on the fixture s pressure gauge, and allow to hold for approximately 2 seconds. Close ball valve, so that the knob position is perpendicular to valve body (see picture below). Activate the stopwatch. Wait 15 seconds and observe the pressure gauge. Because the test was conducted with known good tubing set, the pressure should not fall below 89mmHg (1.72 psi). If pressure falls below 89mmHg, contact your sales rep for replacement tubing set Leak Test Fixture. 6

Section 2 Instructions for Customer Returned Units (continued) TUBING SET VISUAL INSPECTION Inspect the tubing sets for missing, broken or cracked components. If any components are missing, broken or cracked, discard the tubing set. Inspect the tubing set for condensation in the tubing. If condensation is present in the tubing, discard the tubing set. Inspect the printing on the tubing set connectors. If any connectors contain incomplete characters, discard the tubing set. CLEANING Clean the customer returned tube set as per the Kendall SCD 700 system Operation and Service Manual. All visible extraneous markings or materials should be removed by the cleaning step. If extraneous markings or materials are not removed, discard the tubing set. LEAK TEST Inspect the Leak Test Fixture to ensure that it is in working order and that the pressure gauge has a valid calibration date. Ensure that the Leak Test Fixture is connected to a regulated air source. The input air should be at pressure between 3 psi and 4 psi. See sketch below. CONNECT TO AIR Connect the Tubing Set to the connectors on the test fixture. See pictures below. 7

Section 2 Instructions for Customer Returned Units (continued) TUBING SET (continued) LEAK TEST (continued) Turn ball valve to open position, so that the knob position is in-line with valve body (see picture below). Adjust the input air pressure so that a pressure of between 125mmHg (2.4 psi) and 135mmHg (2.6 psi) is indicated on the fixture s pressure gauge, and allow to hold for approximately 2 seconds. Close ball valve, so that the knob position is perpendicular to valve body (see picture below). Activate the stopwatch. Wait 15 seconds and observe pressure gauge. Pressure should not fall below 89mmHg (1.72 psi). If pressure falls below 89mmHg, the tubing set has a leak. Discard the tubing set. NOTE: If tubing set inspection and cleaning is not completed as per the steps above, discard the tubing sets and provide new tubing sets in the package. 8

Section 2 Instructions for Customer Returned Units (continued) KENDALL SCD 700 SYSTEM CONTROLLER VISUAL INSPECTION Inspect the DME supplier contact information label. If the DME supplier contact information label is torn, ripped or illegible, replace with a new label (see sketch below): PLACE LABEL WITHIN THE BOXED AREA Inspect the power cord for damage. If power cord is frayed or damaged, send the controller to the Covidien service center for repair (Reference Attachment A). Inspect the controller for marks, scuffs and scratches especially on the control panel (see below). CONTROL PANEL Minor surface scratches or scuffs are acceptable. If any marks are present that obscure or interfere with the display of the icons or the clear membrane on the control panel, send the controller to the Covidien service center for repair (Attachment A). Inspect the controller for missing, broken or cracked components. If any components are missing, broken or cracked, send the controller to the Covidien service center for repair (Attachment A). Inspect the controller for the presence of the serial label on the bottom of the device. It the serial label is not present, or if it is illegible or damaged, send the controller to the Covidien service center for repair (Attachment A). 9

Section 2 Instructions for Customer Returned Units (continued) KENDALL SCD 700 CONTROLLER (continued) CLEANING Unplug the controller from Mains voltage before cleaning. Clean the customer returned Kendall SCD 700 controller as per the Kendall SCD 700 system Operation and Service Manual. GENERAL FUNCTION TEST With no tubing set connected to the SCD 700 controller, connect the controller to AC power. Verify that the power source light (power on indicator) turns on. Note: Controller must be connected to AC power to enter test mode. See front panel display below: Enter Test Access Mode, and conduct the general function test (test mode T2) as per the Kendall SCD 700 system Operation and Service Manual. Verify battery status: o Turn off the controller. o Disconnect the controller from AC Power, and activate again. o Confirm that battery charge level is at least 2/3 (i.e. 2 or 3 green battery status indicators). o If battery charge level is less than 2/3, connect the controller to AC power, and leave connected to AC power until battery reaches at least 2/3 level. If operation of the SCD 700 controller is not correct as per the above tests, send the controller to the Covidien service center for repair (Attachment A). 10

Section 2 Instructions for Customer Returned Units (continued) KENDALL SCD 700 CONTROLLER (continued) RE-PACKAGING PROCEDURE KIT MATERIALS o Verify that all materials are available, referencing the batch record. o List of materials required to re-package the kit is as follows: Part Description Quantity Part # Vendor Contact Info Kendall SCD 700 system corrugate case 1 1029053 Covidien Kendall SCD 700 system tubing sets (for 2 9528 Covidien replacements) Kendall SCD 700 system hospital DME shipping 1 1077455 Covidien label Return Label 1 N/A N/A N/A Chip Board - AIR-PAQ TM* Protector 1 1059428 Covidien Kendall SCD 700 system AIR-PAQ TM* inflatable packaging 1 1031823 Covidien Polybag for Kendall SCD 700 controller 1 1033373 Covidien Polybag for tubing set 2 F123450 Covidien Twist Ties, Blue Plastic 1 F150023 Covidien Kendall SCD 700 controller QuickStart Guide 1 1066981 Covidien Kendall SCD 700 controller Printed IFU 1 1066980 Covidien PACKAGING INSTRUCTIONS o Using regulated air source set at 9-10 psi of pressure; inflate the AIR-PAQ TM * inflatable packaging. If an air source is not available to inflate AIR-PAQ * inflatable packaging, you should not ship the device. Hand delivery of the kit is recommended in this situation. o Tape the bottom surface of the shipping box. o Place the Chip Board in the box on the bottom surface. Place the Printed IFU in the shipping box on top of the Chip Board. o Place the AIR-PAQ * inflatable packaging into the shipping box on top of the printed IFU. Place a tubing set on either side of the AIR-PAQ TM * inflatable packaging as shown below. TUBING SET AIR-PAQ TM * INFLATABLE PACKAGING TUBING SET 11

Section 2 Instructions for Customer Returned Units (continued) KENDALL SCD 700 CONTROLLER (continued) RE-PACKAGING PROCEDURE (continued) PACKAGING INSTRUCTIONS (continued) o Verify that the DME supplier contact information label is on the Kendall SCD 700 controller. Place the controller into the polybag and use a twist tie to secure. o o Place the Kendall SCD 700 controller in the AIR-PAQ * inflatable packaging, and close the AIR-PAQ * inflatable packaging. Place the QuickStart Guide on top of the AIR-PAQ * inflatable packaging as shown below: o Seal the top of the box and assemble the following labels on the outside of the shipping box as shown below: Pre-printed shipping label on the front wrapping on the left side; Return label to the right of the shipper label. PRE-PRINTED SHIPPING LABEL RETURN LABEL 12

ATTACHMENT A: Instructions for Returning Damaged Controllers To obtain service on your Covidien Kendall SCD 700 controller, you must contact the service department and request a Return Material Authorization Number (RMA). Please contact the service department by: 1. Phone- opt 1/opt 1 2. Email: SWM.customerservice@covidien.com 3. CovidienConnect: https://www.covidienconnect.com/ Please have the following available when contacting the service department: Account Bill To Account Ship To Device Serial Number Reason for service/return Contact information for Estimate approval if applicable: (Name, Phone Number & Email address) Repackage the Kendall SCD 700 controller carefully in its original box. List the RMA number on the shipping label or exterior of the box. Equipment returned without RMA number will not be serviced! Mail Device to: Covidien 5290 Longbow Drive Building 4 Service Dock Boulder, Co 80301 COVIDIEN, COVIDIEN with logo, and Covidien logo are U.S. and internationally registered trademarks of Covidien AG. * Trademark of its respective owner. Other brands are trademarks of a Covidien company. Covidien llc, 15 Hampshire Street, Mansfield, MA 02048 USA. 2014 Covidien 14MAN0014 07/14 13