Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Similar documents
Product and functional description

KNX Interface. User Manual PM00A00IRI

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Product and Application Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Digital input modules

Transmitter Actuator 230V wave UP 560. Operation

PCS0100en Persy Control Services B.V. Netherlands

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

TX OPEN RS232/485 module

EIB/KNX IP Interface with Power over Ethernet (PoE)

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Electronic overload relay EF19 and EF45

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Electronic overload relay EF65, EF96 and EF146

Modular I/O System Analog and Digital Interface Modules

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

HARAX circular connector

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Drayton Digistat +2RF/+3RF

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

instabus KNX / EIB System System E F G H

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Quick Connect. quick - simple - efficient.

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

is then retained absolutely without interruption.

ACS-30-EU-EMDR-10-MOD

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

PHOENIX CONTACT Features

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

E-STOP relays, safety gate monitors

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Actuator-Sensor-Interface

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Duct Humidity Transmitter

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

ABB i-bus KNX SA/S Switch Actuators Product Manual

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Safety technique. Emergency stop module BO 5988 safemaster

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Three-phase monitoring relay CM-PFE

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

38 Series - Relay interface modules A

LIEBERT VNSA Installation Sheet

Contact expansion modules

gesis KNX RM Manual Installation System for European Installation Bus Product and Object Description Doc. no. BA Wieland Electric GmbH

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

38 Series - Relay interface modules A

AXIS T81B22 DC 30W Midspan

MCR1900 Media Converter 19-Slot Chassis

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

5SV Residual Current Protective Devices

HERZ-Thermal Actuators

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DALI RC BASIC SO. Control unit Operating instructions

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

CompactLogix Power Supplies Specifications

Contact expander modules

49 Series - Relay interface modules A. Features

RM4TG20 three-phase network control relay RM4-T - range V

Power Supplies 3. SDN-P DIN Rail Series

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Emergency lighting units EM powerled

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

MasterINTERFACE 39 Series - Relay interface modules

Plug and Socket Devices CES 63 A Series 8579

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

J TB/TW Temperature limiter, temperature monitor

48 SERIES Relay interface modules 10 A

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

2013 Wireless Video Intercom INSTALLATION GUIDE

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

MINI MCR-SL-R-UI(-SP)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Transcription:

Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an additional line via a separate choke N 120. The power supply units N 125/x2 can be powered by AC 120 230V or by DC 220V. Application Programs The power supply unit N 125/x2 provides the system power necessary for the instabus KNX. The connection to the bus line is established by clicking the device onto the DIN-rail (with a data rail installed) and/or via the bus connection block located on the front side. If the power supply N 125/x2 is installed the bus connector module REG 191 is not necessary (also for other DIN-rail devices connected to the same data rail) because the bus voltage is carried inside the device from the bus terminal block to the data rail. The integrated choke prevents the data telegrams from short-circuiting on the bus line. When the built-in reset switch is operated (operation > 20s), the bus devices are returned to their initial state. For each bus line, at least one power supply unit N 125/x2 is needed. Up to two power supply units may be attached to a single bus line. A second unit is not required unless the supply voltage at a bus device is less than 21 V. Note: If two power supply units N 125/x2 are operated in parallel on one bus line and if the overload LED is lit on one or both power supplies, then the bus configuration has to be changed until the overload display disappears. The cable length between the two power supply units N 125/x2 operated in parallel is not prescribed. When more than 30 bus devices are installed in short bus cable distance (e.g. 10 m), e.g. in distribution boards, the power supply unit N 125/x2 should be arranged near these bus devices. The distance between power supply unit N 125/x2 and any of its bus devices must not exceed 350 m. The power supply unit N 125/x2 has a voltage and current regulation and is therefore short-circuit proof. Short power failures can be bridged with a backup interval of approximately 200 ms. To ensure an uninterrupted power supply a separate circuit with safety separation should be used for the power supply unit N 125's power supply line. Requires no application programs Example of Operation Siemens AG N 125/x2, page 1 / 6 Technical Manual Control Products and Systems Siemens AG 2012 Update: http://www.siemens.de/installationstechnik 2.14.4.4/1

Installation Instructions The device may be used for permanent interior installations in dry locations within distribution boards or small casings with DIN rail EN 60715-TH35-7,5. V WARNUNG The device may be built into distribution boards (230/400V) together only with appropriate VDEdevices. The device must be mounted and commissioned by an authorised electrician. Free DIN rail areas with sticked-in data rails must be covered with covers, order no. 5WG1 192-8AA01. A safety disconnection of the device must be possible. The prevailing safety rules must be heeded. The device must not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Technical Data Input voltage rated voltage: AC 120-230 V, 50...60Hz DC 220V permissible range: AC 102...253V, DC 176...270V Rated power intake approx. 24 VA Output voltage rated voltage: DC 29 V safety extra low voltage (SELV) permissible range: DC 28... 30 V Output current rated current 160 ma (N125/02), 320 ma (N125/12), 640 ma (N125/22) short-circuit current: limited to 1,0 A (N125/02, N125/12), 1,5 A (N125/22) Backup interval on input voltage failure: approx. 200 ms at rated current Operator elements slide switch: for resetting the bus devices connected to the line (operation > 20 s) Display elements 1 red LED: for indicating a voltage interruption on operating the slide switch in RESET-position 1 green LED: for indicating normal operation 1 red LED: for indicating a shorted-out bus line or device over-load Connections mains connection, screwless plug-in terminals: strip insulation for 10... 11 mm permissible conductor types/cross sections: - 0.5... 2.5 mm² ( AWG 12) single core - 0.5... 1.5 mm² plain flexible conductor - 0.5... 2.5 mm² (AWG 12) stranded conductor - 0.5... 2.5 mm² (AWG 12) flexible conductor with terminal pin, crimped on gas tight bus line: pressure contacts on data rail, screwless extra low voltage terminal (red black) 0.6... 0.8 mm output voltage (no choke): screwless extra low voltage terminal (yellow-white) 0.6... 0.8 mm Technical-Manual N 125/x2, page 2 / 6 Siemens AG Update: http://www.siemens.de/installationstechnik Siemens AG 2012 Control Products and Systems 2.14.4.4/2

Physical specifications housing: plastic dimensions: N-system DIN-rail mounted device, width: 4 SU (1 SU = 18 mm) Fire load: approx. 3700 kj weight: approx. 260 g installation: rapid mounting on DIN rail according to EN 60715-TH35-7,5 Electrical safety degree of pollution (according to IEC 60664-1): 2 protection (according to EN 60529): IP 20 Overvoltage category (according to IEC 60664-1): III bus: safety extra low voltage SELV DC 24 V device complies with EN 50 491-3, EN 61558-2-6 and EN 61558-2-16 Electromagnetic compatibility complies with EN 50491-5-1, -5-2, -5-3 Environmental specifications climatic conditions: EN 50090-2-2 ambient temperature operating: - 5... + 45 C storage temperature: - 25... + 70 C relative humidity (non-condensing): 5 % to 93 % Reliability Failure rate: 1178 fit at 40 C Markings EIB KNX certified CE mark complies with the EMC regulations (residential and functional buildings), and low voltage regulations Location and Function of the Display and Operating Elements A1 + - A2 L N A3 + - A8 A9 A4 A5 A6 A7 Figure 1: Location of the display and operator elements A1 extra low-voltage bus terminals (red-black) A2 reset switch A3 extra low-voltage terminals (yellow-white) A4 type plate A5 red LED for indicating that the power supply unit N 125/x2 is in reset position A6 green LED for indicating normal operation of the power supply unit N 125/x2 A7 red LED for indicating a shorted-out bus line or a device over-load A8 screwless plug-in terminals for connecting the mains (mains terminals) A9 ground terminal Siemens AG N 125/x2, Seite 3 / 6 Technik-Handbuch Control Products and Systems Siemens AG 2012 Update: http://www.siemens.de/installationstechnik 2.14.4.4/3

Mounting and Wiring General description The N-system DIN-rail device can be installed to N-system distribution boards, surface or flush mounted, or to any DIN-rail available that has a data rail installed. The connection to the bus line is established by clicking the device onto the DIN-rail (with a data rail installed). Take care that the type plates of all devices on a DIN-rail can be read in the same direction, guaranteeing the devices are polarised correctly. Connecting mains (figure 3) - The mains are connected via screwless plug-in terminals (E1). - Remove approx. 10 to 11 mm of insulation from the wire (E2) and plug it into the terminal (E1). Disconnecting the mains (figure 3) - Press the terminal lock (E3) of the terminal (E1) with a screw-driver and - remove the wire (E2) from the terminal (E1). Connection to the bus without data rail If the connection is established via bus connection block (data rail not installed) the data rail connection system has to be covered with the enclosed insulation hood after removing the guiding hood e.g. with a screw driver to guarantee a sufficient insulation from the DIN rail. Removing the guiding top (Figure 2) The guiding top (D3) surrounds the contact system (D2) on the back side of the device (D1). Insert the screw driver between the DIN-rail device (D1) and the guiding hood (D3) and remove the guiding hood. Inserting the insulation top (Figure 2) Put the insulation top (D4) onto the contact system and click it into place by a slight pressure. D3 D1 D2 Figure 2: Mounting and dismounting a DIN-rail device D2 D4 D1 Figure 3: Connecting and disconnecting wires Slipping on of the safety extra low voltage block slip the connection block onto the guide slot and press the connection block down to the stop Connecting the safety extra low voltage block (figure 4) The connection block (F2) can be used with single core conductors Ø 0,6... 0,8 mm. - The connection block (F2) consists of a red (yellow) connector (F2.1) and a black (white) connector (F2.2). Each connector can take up to four wires with single core conductors Ø 0,6... 0,8 mm. Remove approx. 5 mm of insulation from the conductor (F2.4) and plug it into the connection block (F2) (red = +, black = -). Disconnecting the safety extra low voltage block (figure 4) - Unplug the connection block (F2) and remove the bus cable conductor (F2.4) while simultaneously wiggling it. F2 F2.3 F2 F2.4 5 mm F2 F2.1 F2.2 Figure 4: Connecting and disconnecting safety extra low voltage block F2.4 Technical-Manual N 125/x2, page 4 / 6 Siemens AG Update: http://www.siemens.de/installationstechnik Siemens AG 2012 Control Products and Systems 2.14.4.4/4

Dimension Diagram Dimensions in mm 90 45 b 44 55 b = 4 SU 1 Standard unit (SU) = 18 mm General Notes The operating instructions must be handed over to the client. Any faulty device is to be sent together with a return delivery note of the local Siemens office. For any technical questions, please consult: +49 (911) 895-7222 +49 (911) 895-7223 support.automation@siemens.com www.siemens.com/automation/support-request Siemens AG N 125/x2, Seite 5 / 6 Technik-Handbuch Control Products and Systems Siemens AG 2012 Update: http://www.siemens.de/installationstechnik 2.14.4.4/5

Space for Notes Technical-Manual N 125/x2, page 6 / 6 Siemens AG Update: http://www.siemens.de/installationstechnik Siemens AG 2012 Control Products and Systems 2.14.4.4/6