Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Similar documents
Actuator for modulating control AME 435

HERZ-Thermal Actuators

Electric Rotary Actuator - On/Off or programmable control actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Telefon (+45) Telefax (+45) Installation and operating manual

Cable Plug acc. to DIN EN , Form A

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Duct Humidity Transmitter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Heating, air-conditioning, cooling

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

48 SERIES Relay interface modules 10 A

Modular I/O System Analog and Digital Interface Modules

38 Series - Relay interface modules A

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Combi switchbox with integrated 3/2 way pilot valve

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

WINGLIKE ELECTRONICS CO.,LTD

Electronic Control Devices The European Product Catalogue 2007

Digital inductive conductivity transmitter


PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Digital input modules

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

38 Series - Relay interface modules A

Product and functional description

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MINI MCR-SL-R-UI(-SP)

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

TX OPEN RS232/485 module

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

EFC Frequency converters

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Quick running actuator

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Electronic Control Devices The European Product Catalogue 2007

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Air damper actuators

3/2-way Solenoid Valve, direct-acting, NC or NO

Series 6000 Torque measured metal bellow coupling

HYDRUS ULTRASONIC METER

Hydraulic Control Solutions

Danfoss Link Mobile Phone Butler

Proportional pressure regulators VPPE

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

WD-AMX Water Detection Controllers

Power Supplies 3. SDN-P DIN Rail Series

MPPM1606 MPPM2508 MPPM3210

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

RY2 miniature industrial relays

Series 7500 Torque Sensor

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

MAXIMUM LOAD CURRENT 1 A SN SERIES

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

is then retained absolutely without interruption.

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

IO-DIM6 6-Channel, Digital to Analogue Converters

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

49 Series - Relay interface modules A. Features

NC-12 Modbus Application

Contents. Document information

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04


MLC TM Maximum Productivity and Versatility for Control without Compromise!

Control- and feedback head for integrated mounting on Robolux valves Type 2036

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

PNOZsigma - Base units

ABB Drives. User s Manual HTL Encoder Interface FEN-31

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

MPLM1630 MPLM2535 MPLM3240

Thermal-Magnetic Circuit Breaker M1-..

Inductive sensor NI10-M18-Y1X-H1141

LOXONE 12 Channel Amplifier

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

API Marine. BMS Presentation. Ballast Measurement Systems

E-STOP relays, safety gate monitors

How To Use A Flowmeter

Transcription:

Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on the valve by hand and without the need of a specific tool. Due to the compact design of the actuator, it is particularly suitable for installations where space is limited. Features motoric actuators Nominal on proportional 0-10V actuator up to 5.5 mm. Presetting from factory 2.5 or 5.5 mm 3-position or 0..10 V DC control signal. Other control signals can be selected by use of dip switches Direct assembly with union nut to the neck of the valve. No tools required Bi-color LED for status and diagnostic Linear or EQ% characterization available on the same actuator The actuator is short-circuit-proof and protected against polarity reversal Plug-in cable for supply voltage and control signal Features thermic actuators Self calibrating on proportional 0-10V actuator On/Off or 0..10 V DC control signal Simple snap-on installation Small outer dimensions Cable included First-Open function IP 54 protection Power consumption 1-2 W Approval EN FEB 16 Small outer dimensions Removable cable Auto zero detection IP 43 protection Voltage and Current analog inputs Conforms to: EMC directive 2004/108/EC Low voltage directive 2006/95/EC

Page 2 of 6 Technical data motoric actuators Supply voltage: See Types and Operation data Protection class: IP 43 acc. EN60529 Frequency: 50/60 Hz Input impedance: > 100 k Ohm (DC 0...10v) Force: >120N Stroke: 2.5-5.0-5.5mm (Dip switches) Ambient conditions: Temperature 0 C...50 C Humidity 10-90% r.f. Cable length: 1.5 m Weight: 215 g Types and Operation Data Types Valve Dim. Control signal Running time (50 Hz) Supply voltage Power Consumtion Parallel operation No. of actuator 53-1180 DC 0..10 V 5.5mm 8 s/mm AC/DC 24 V +/- 15% 2.5 VA Max. 4 53-1181 3 - position/on/off 13 s/mm AC 24 V +/- 15% 2.5 VA Max. 4 53-1182 3 - position/on/off 13 s/mm AC 230 V +/- 10% 6.5 VA Max. 4 53-1183 DC 0..10 V 2.5 mm 8 s/mm AC/DC 24 V +/- 15% 2.5 VA Max. 4 Technical data thermic actuators Characteristics: Thermic actuators, NC Protection class: IP 54 to EN 60529 Frequency: 50/60 Hz Control signal: 0-10V DC or On/Off Force: 100 N Stroke: 2.5-5.0-5.5 mm Running time: 120 s 0-10V/180 s On/Off Ambient conditions: 0 C...60 C Cable length: 1.0 m Weight: 100 g Types and Operation Data EN FEB 16 Types Valve Dim. Control signal Running time (50 Hz) Supply voltage Power Consumtion For valve 48-5525 DN10-DN20 On/Off 180 s AC/DC 24 V 1 W 2.5 mm 48-5526 DN10-DN20 On/Off 180 s AC 230 V 1 W 2.5 mm 48-5527 On/Off 180 s AC/DC 24 V 1.2 W 5.0-5.5 mm 48-5528 On/Off 180 s AC 230 V 1.2 W 5.0-5.5 mm 48-5529 DC 0..10 V 30 s/mm AC 24 V 1.2 W 2.5-5.0-5.5 mm 48-5532 DN10-DN20 On/Off 180 s AC/DC 24 V 2 W 2.5 mm 48-5533 DN10-DN20 On/Off 180 s AC 230 V 2 W 2.5 mm

Page 3 of 6 Dimensions [mm] 48-5527 48-5528 48-5529 48-5525 48-5526 48-5532 48-5533 53-1180 53-1181 53-1182 53-1183 Combination matrix: Frese OPTIMA Compact DN10-15-20-25-32 / Actuators Frese OPTIMA Compact can be combined with both thermic actuators and motoric actuators. Thermic Actuators Motoric Actuators The design of the valve. combined with the Frese actuator. produces a perfect control characteristic that utilises the full control range of the system. On/Off 0...10V 0...10V 3-pos Male/Male ISO 228 Type Stroke mm Flow l/h Dim 24 V 2.5mm 230V 2.5mm 5.0-5.5mm 230V 5.0-5.5mm 2.5-5.0-5.5 mm 2.5 mm 5.0-5.5mm 230V DN10 M/M LOW 2.5 2.5 30-200 DN10 DN10 M/M LOW 5.0 5.0 65-370 DN10 DN15 M/M LOW 2.5 2.5 30-200 DN15 DN15 M/M LOW 5.0 5.0 65-370 DN15 DN15 M/M HIGH 2.5 2.5 100-575 DN15 DN20 M/M HIGH 2.5 2.5 100-575 DN20 DN20 M/M HIGH 5.0 5.0 220-1330 DN20 DN25 M/M 5.5 5.5 600-3609 DN25 DN32 M/M 5.5 5.5 550-4001 DN32 EN FEB 16 Female/Female ISO 7/1 Type Stroke mm Flow l/h Dim DN15 F/F LOW 2.5 2.5 30-200 DN15 DN15 F/F LOW 5.0 5.0 65-370 DN15 DN15 F/F HIGH 2.5 2.5 100-575 DN15 DN20 F/F HIGH 2.5 2.5 100-575 DN20 DN20 F/F HIGH 5.0 5.0 220-1330 DN20 DN25 F/F 5.5 5.5 600-3609 DN25 DN32 F/F 5.5 5.5 550-4001 DN32

Page 4 of 6 Connection diagrams thermic actuators 48-5525 48-5527 48-5532 On/Off 24 V AC/DC L1 L2 GND Blue Brown 48-5526 48-5528 48-5533 On/Off 230V 230 V AC L1 L2 GND Blue Brown 48-5529 0-10V 24 V AC L1 L2 0-10 V DC EN FEB 16 GND Blue Red Black

Page 5 of 6 Connection diagrams motoric actuators 53-1180 0-10V,, 5.5 mm 53-1183 0-10V,, 2.5 mm BLK RED GRY (-) (+) 24 VAC/DC 53-1181 3-position 53-1181 On/Off 53-1182 3-position 230V 53-1182 On/Off 230V BLU BRN BLU BRN BLU BRN BLU BRN EN FEB 16 N L1 230VAC N L1 230VAC N L1 230VAC N L1 230VAC

Page 6 of 6 Configuration motoric actuators 53-1180 & 53-1183 ON OFF Dip switch 1-2-3 Control signal range Factory setting 0-10V 1 2 3 4 5 6 0...10VDC 0...20mA DA LIN VDC 0...5VDC 5...10VDC RA Eq% ma 2...10VDC 4...20mA Dip switch 4 Stem action Factory setting RA (Reverse acting) RA (Reverse acting) DA (Direct acting) Dip switch 5 M Actuator characterization Factory setting EQ% M M Signal EQ% characterization Signal Signal Linear characterization The actuator can be selected via the Jumper and can be set to 2.5mm - 5.0mm or 5.5 mm EN FEB 16 53-1180 Factory setting 5.5 mm 53-1183 Factory setting 2.5 mm Frese A/S assumes no responsibility for errors, if any, in catalogues, brochures, and other printed matter. Frese A/S reserves the right to modify its products without prior notice, including already ordered products, if this does not alter existing specifications. All registered trademarks in this material are the property of Frese A/S. All rights reserved. 2,5 mm 5,0 mm 5,5 mm Frese A/S Sorøvej 8 DK- 4200 Slagelse Tel: +45 58 56 00 00 Fax: +45 58 56 00 91 info@frese.dk