Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface



Similar documents
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical Data. Dimensions

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Electronic Pressure Switch EDS 300

Technical Data. Dimensions

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

RS - SPM. Serial parallel translator module

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

BOS 73K... BOS 74K...

Instruction Manual Service Program ULTRA-PROG-IR

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Series 7500 Torque Sensor

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Electronic Pressure Switch EDS 3000

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Inductive sensor NI10-M18-Y1X-H1141

Color Mark Sensor with Red or Green LED E3S-VS

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

crm+25/d/tc/e Extract from our online catalogue: Current to:

ATL Fuel Level Sender Probes

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

WEB log. Device connection plans

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Proportional pressure regulators VPPE

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

crm+130/iu/tc/e Extract from our online catalogue: Current to:

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Hand-held thermometer Model CTH7000

2.24. Pump Controller 704. Data Sheet

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Series 6000 Torque measured metal bellow coupling

User's Guide. Integrating Sound Level Datalogger. Model Introduction

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Liquid Level Limit Switch liquiphant T FTL 20

Digital input modules

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

PCS0100en Persy Control Services B.V. Netherlands

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Modular I/O System Analog and Digital Interface Modules

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

How To Make An Ultrasonic Sensor

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

ABSOLUTE ROTARY ENCODER ETHERNET/IP

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

CHAPTER 11: Flip Flops

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

is then retained absolutely without interruption.

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Model 201 Wiegand Touchpad Reader Installation Guide

In-Sight Hardware specifications

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

1 Technical Description Lokal-200PC

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Operating instructions IV / 2007

WEB log. Device connection plans

Conductive Level Switch FK 2 Technical Data:

Duct Humidity Transmitter

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

General 1-2-Opto-electronics Safety Switches 4-Emergency

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

TMS TANK MANAGEMENT SYSTEM

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Cross-beam scanning system to detect slim objects. 100 mm in

Multifunction devices

Multi-Protocol decoder with Load regulation

2M IR Mini Dome Quick Installation Guide

Preset Counter signo 721

intelligent solutions

Capacitive Prox E2K-X

Product and functional description

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

LED...A Q Series Sealed High-Intensity

Install the DeviceNet Module using the following procedure:

Introduction to Fiber Optic Cables. Photoelectric Sensors. 2Photoelectric Sensors, Standard Sensors, Fiber optic cables. Please Note!

REGTRONIC OPERATING INSTRUCTIONS

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

Voltage Regulator SPAU 341 C. Product Guide

Relative and absolute pressure switch type 529

Adjustment functions for both span and shift have been incorporated

Transcription:

Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 Analog current and voltage output Synchronization options Adjustable acoustic power and sensitivity Temperature compensation Diagrams Characteristic response curve Distance Y [m]..0 0. 0.0-0. -.0 -. 0,0 0,,0,,0,,0,,0,,0, 6,0 6, Y Distance X [m] X Curve : flat surface 00 mm x 00 mm Curve : round bar, Ø mm Technical data General specifications Sensing range Adjustment range Dead band Standard target plate Transducer frequency Response delay Indicators/operating means green yellow yellow red Temperature/TEACH-IN connector Electrical specifications Operating voltage U B Power consumption P 0 Interface Interface type Input/Output Synchronization 00... 000 mm 0... 000 mm 0... 00 mm 00 mm x 00 mm approx. 8 khz ms minimum 0 ms factory setting solid: Power-on flashing: Standby mode or program function object detected solid: object in evaluation range flashing: program function solid: object in detection range flashing: program function solid: temperature/program plug not connected flashing: fault or program function object not detected Temperature compensation, Evaluation range programming, output function setting 0... 0 V DC, ripple 0 % SS 900 mw RS, 9600 Bit/s, no parity, 8 data bits, stop bit bi-directional 0 level -U B...+ V level: + V...+U B input impedance: > KOhm synchronization pulse: 00 µs, synchronization interpulse period: ms Synchronization frequency Common mode operation Hz Multiplex operation Hz / n, n = number of sensors, n Output Output type current output... 0 ma voltage output 0... 0 V Resolution evaluation range [mm]/000, but 0. mm Deviation of the characteristic curve 0. % of full-scale value Repeat accuracy 0. % of full-scale value Load impedance current output: 00 Ohm Voltage output: 000 Ohm Temperature influence % from full-scale value (with temperature compensation) 0. %/K (without temperature compensation) Ambient conditions Ambient temperature -... 70 C (-... 8 F) Storage temperature -0... 8 C (-0... 8 F) Mechanical specifications Connection type Connector M x, -pin Degree of protection IP6 Material Housing stainless steel (.0 / AISI 0) PBT plastic parts Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam Mass 0 g Factory settings Output evaluation limit A: 00 mm evaluation limit A: 000 mm rising ramp Compliance with standards and directives Standard conformity Standards EN 6097--:007 + A:0 IEC 6097--:007 + A:0 EN 6097--7:00 IEC 6097--7:00 Approvals and certificates UL approval culus Listed, General Purpose CSA approval ccsaus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 6 V USA: + 0 86 000 Germany: +9 6 776 Singapore: +6 6779 909

Dimensions ø0 Additional Information Analogue output function Analog function 6 8 Rising slope ma/0 V Near distance of evaluation Falling slope 0 ma/0 V Zero line mode ma/0 V Far distance of evaluation A= 0 mm A 0 ma/0 V ma/0 V 0 ma/0 V Temperature probe Coded plug M0x. 7. Electrical Connection Standard symbol/connection: (version IU) U (BN) (GY) (WH) (BK) (BU) + U B Sync. 0-0 V -0 ma - U B Core colors in accordance with EN 6097--. Pinout Wire colors in accordance with EN 6097-- BN WH BU BK GY (brown) (white) (blue) (black) (gray) Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml USA: + 0 86 000 Germany: +9 6 776 Singapore: +6 6779 909

Accessories BF 0 Mounting flange, 0 mm BF 0-F Mounting flange with dead stop, 0 mm UC-0GM-PROG ULTRA000 Software for ultrasonic sensors, comfort line UC-0GM-R DA-IU-K-V Process control and indication equipment V-G-M-PVC Female cordset, M, -pin, PVC cable Description of Sensor Functions Programming procedure The sensor features programmable analog outputs with programmable evaluation range. Programming the evaluation range and the operating mode is done either via the sensor's RS interface and ULTRA000 software (see the ULTRA000 software description) or by means of the programming plug at the sensor's back end which is described here. Programming of Evaluation Range. Disconnect supply voltage. Remove the programming plug to activate program mode. A. Reconnect supply voltage (Reset). Place the target at the desired position for A. Momentarily insert the programming plug in position A and then remove. This will program the position A. 6. Place the target at the desired position for A A E/E 7. Momentarily insert the programming plug in position A and then remove. This will program the position A. Notes: T Coded plug Removing the programming plug saves the new position into the device memory. The programming status is indicated by the. A flashing green indicates that the target is detected; a flashing red indicates that no target is detected. Programming the Operation Mode If the program mode is still activated, continue at number. If not, activate program mode by performing the sequence numbers to.. Disconnect supply voltage. Remove the programming plug to activate program mode.. Reconnect supply voltage (Reset). Insert the programming plug in position E/E. By removing and reinserting the plug, the user can toggle through the three different modes of operation. The selected mode is indicated by the s as shown below: Rising slope mode, A flashes Falling slope mode, A flashes Zero line mode, s A and A flash. ce the desired mode is selected, insert the programming plug in position T. This completes the programming procedure and saves the switch points and mode of operation. 6. The sensor now operates in normal mode. The programming plug also functions as the temperature compensation. If the programming plug has not been inserted in the T position within minutes, the sensor will return to normal operating mode with the latest saved values, without temperature compensation. Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Factory settings See technical data. Display The sensor provides s to indicate various conditions. USA: + 0 86 000 Germany: +9 6 776 Singapore: +6 6779 909

# During Normal Operation - Temperature compensated - with removed programming plug Interference (e.g. compressed air) During Sensor Programming Evaluation limit A: Object detected No object detected Evaluation limit A: Object detected No object detected Operation mode: Rising slope mode Falling slope mode Zero line mode Green Red Yellow A Yellow A Object in evaluation range Object in evaluation range remains in previous state Object in sensing range Object in sensing range remains in previous state Standby remains in previous state remains in previous state yellow Dual- green/red yellow E E A A Evaluation limit Evaluation limit "Power on"/disturbance Synchronization This sensor features a synchronization input for suppressing ultrasonic mutual interference ("cross talk"). If this input is not connected, the sensor will operate using internally generated clock pulses. It can be synchronized by applying an external square wave. The pulse duration must be 00 µs. Each falling edge of the synchronization pulse triggers transmission of a single ultrasonic pulse. If the synchronization signal remains low for second, the sensor will revert to normal operating mode. Normal operating mode can also be activated by opening the signal connection to the synchronization input (see note below). If the synchronization input goes to a high level for > second, the sensor will switch to standby mode, indicated by the green. In this mode, the outputs will remain in the last valid output state. If the option for synchronization is not used, the synchronization input has to be connected to ground (0 V) or the sensor must be operated via a V cordset (-pin). The synchronization function cannot be activated during programming mode and vice versa. The following synchronization modes are possible:. Several sensors (max. number see technical data) can be synchronized together by interconnecting their respective synchronization inputs. In this case, each sensor alternately transmits ultrasonic pulses in a self multiplexing mode. No two sensors will transmit pulses at the same time (see note below).. Multiple sensors can be controlled by the same external synchronization signal. In this mode the sensors are triggered in parallel and are synchronized by a common external synchronization pulse.. A separate synchronization pulse can be sent to each individual sensor. In this mode the sensors operate in external multiplex mode (see note below).. A high level (+U B ) on the synchronization input switches the sensor to standby mode. Sensor response times will increase proportionally to the number of sensors that are in the synchronization string. This is a result of the multiplexing of the ultrasonic transmit and receive signal and the resulting increase in the measurement cycle time. Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Note on communication with the UC-0GM-R interface cable The UC-0GM-R interface cable allows for communication with the ultrasonic sensor using ULTRA000 software. The cable creates a connection between a PC RS- interface and the programming plug socket on the sensor. When connecting to the sensor, make certain the plug is lined up correctly; otherwise no communication will be possible. The key of the cable s plug must be aligned to the groove of the socket on the sensor (not with the arrow symbol on the sensor). Programmable parameters with the ULTRA000 software Evaluation limits A and A Operation mode Sonic speed Groove Temperature/program connector (PC connection via interface cable UC-0GM-R) : TXD : RXD : not used : GND Temperature offset (The inherent temperature-rise of the sensor can be considered in the temperature compensation) Expansion of the unusable area (for suppression of unusable area echoes) Reduction of the detection range (for suppression of remote range echoes) Time of measuring cycle Acoustic power (interference of the burst duration) Sensitivity Behavior of the sensor in case of echo loss Behavior of the sensor in case of a fault Average formation via an allowed number of measuring cycles Selection of the parameter set, RS or manually When connected to a PC and running the ULTRA000 software, the sensor can act as a long term data logger as well. V-plug connector (Mx) -window USA: + 0 86 000 Germany: +9 6 776 Singapore: +6 6779 909

Installation conditions If the sensor is installed in an environment where the temperature can fall below 0 C, one of these mounting flanges must be used for mounting: BF0, BF0-F, or BF -0. If the sensor is mounted in a through hole using the included steel nuts, it must be mounted at the middle of the threaded housing. If it must be mounted at the front end of the threaded housing, plastic nuts with centering ring (optional accessories) must be used. Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml USA: + 0 86 000 Germany: +9 6 776 Singapore: +6 6779 909