TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE: WWW.WERMAC.ORG/



Similar documents
Selecting TEMA Type Heat Exchangers

5.2. Vaporizers - Types and Usage

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Thermal design of shell-and-tube

Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers

Examples for Heat Exchanger Design

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

HEAT EXCHANGERS. Prepared by Bob Heaslip KESCO

Design of heat exchangers

05 Heat Transfer & its Applications

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

This will also provide you with the knowledge to insure long life for your Investment

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger

DESIGN STANDARDS SECTION

TITANIUM FABRICATION CORP.

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

Sondex Welded heat exchangers:

Corrugated Tubular Heat Exchangers

C. starting positive displacement pumps with the discharge valve closed.

FLASH TANK ECONOMIZER PRODUCT GUIDE

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

How To Clean Water From An Ammonia Refrigeration System

Why and How we Use Capacity Control

Steam Jet Vacuum Pumps

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Liquid Distributors. Liquid Redistribution. Liquid Distribution. INTALOX Distributors

TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion

DESIGN AND APPLICATION OF HAIRPIN HEAT EXCHANGERS

SECTION 3: CLARIFICATION AND UTILITIES (1)

Steam System Best Practices Condensate System Piping

VAD. Variable Area Desuperheaters

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Float and Thermostatic Traps Series H, C and X

LESSON 1. HEAT EXCHANGERS

Boiler & Pressure Vessel Inspection discrepancies and failures

Chokes. Types Reasons Basics of Operations Application

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

Installation, Operation, & Maintenance Instructions For JFD Shell & Tube Heat Exchangers

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

TABLE OF CONTENT

Oil and Coolant Circulating Heating System. Model - OCSM

Desuperheater Online Program Sizing Guidance

NFPA31FuelOilPiping 1 Revised

BRAZED PLATE INSTALLATION MANUAL

How To Understand Evaporator

Aspen Exchanger Design & Rating Family

HIGH PRESSURE FEEDWATER HEATER REPAIR

Air Eliminators and Combination Air Eliminators Strainers

TYPE E Main Valve Sizes 3 /8 through 12

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Heat Pipe Selection Revision 12/04/2001

VAD Variable Area Desuperheaters

Air Conditioning 101. STN Presentation AC101

ASME B31.3 Process Piping. Scope of B31.3 Course

Rubber Lining Application Manual Revision Date: September 1, Section 10: Pipe Lining Procedures Page: 10-1

TABLE OF CONTENT

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

Efficiency on a large scale CFB Steam Boilers

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

GAS COOLING SYSTEMS FOR STEAM REFORMING PLANTS

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Black Liquor Evaporators: Design and Operation

Oil and Gas Pipeline Design, Maintenance and Repair

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Submersion/Insertion Toroidal Sensor

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Heat Exchangers. Plate-and-Frame COMPACT HEAT EXCHANGERS PART 1: heat exchangers. Use these design charts for preliminary sizing.

Automobile Air Conditioning Primer

Mechanical shaft seal types and sealing systems

GEOTHERMAL HEATING AND COOLING INTRODUCTION

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

100DHP TM CCI DRAG Control Valve For High Pressure Turbine Bypass

Petrochemical Refinery Maintenance. Complete Maintenance Solutions

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

HIGH TEMPERATURE TWIN SCREW PUMPS. By: David B. Parker Two Screw Product Engineer IMO Pump Warren Warren, Massachusetts

James M. Pleasants Company

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

AIR CONDITIONING TECHNOLOGY

QUADRANT SR- Thermal Oxidizer Process Design & Environmental Control Benefits for the Sand Coating Industries

Flowserve - Edward Valves Development of the Flowserve Edward Equiwedge Gate Valve

Mechanical Seal Piping Plans

Unsteady State Relief Valve Evaluation. External Pool Fire Scenario

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

How To Clean Up A Reactor Water Cleanup

BB-18 Black Body High Vacuum System Technical Description

Rusty Walker, Corporate Trainer Hill PHOENIX

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

Practice Test. 4) The planet Earth loses heat mainly by A) conduction. B) convection. C) radiation. D) all of these Answer: C

Shell and Tube Heat Exchanger Design Software for Educational Applications*

Welding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)

Transcription:

TEMA DESIGNATIONS OF HEAT EXCHANGERS Because of the number of variations in mechanical designs for front and rear heads and shells, and for commercial reasons, TEMA has designated a system of notations that correspond to each major type of front head, shell style and rear head. The first letter identifies the front head, the second letter identifies the shell type and the third letter identifies the rear head type. REMOVABLE BUNDLE EXCHANGERS Removable bundle exchangers give the customer the ability to replace the tube bundle without replacing the shell or bonnets. They are generally less cost effective than non removable designs. BEU/AEU- U Bundle Exchangers are generally the most cost effective design style of removable bundle exchanger. Tubes may be water blasted, steam or chemically cleaned. These units must have an even number of tube passes, sometimes limiting their applicability to a service(e.g. they generally can not be used when a temperature cross occurs). CEU- This design has the tubesheet welded to the bonnet. You can remove the bundle from the shell, however to replace the bundle, the inlet bonnet is included or you must cut off the tubesheet. Tubes may be chemically cleaned, water blasted or steam cleaned. BEW/AEW- These are straight tube units with one floating head and one stationary head. The floating head is generally sealed with an O-Ring. These units are most often used as oil coolers or air coolers. Cleaning can be performed either by chemical, mechanical method, water blast or steam cleaning. AEP/BEP- These are straight tube units with one inside packed floating head and one stationary head. The floating head is generally sealed with packing. These units are most often used as intercoolers and aftercoolers with the gas on the tube side. They are also the most common style for oxygen service exchangers. These units have been used in services with tube side design pressures in excess of 2000 PSIG. AES/AET- These units are the most expensive of the removable bundle designed units. The floating head is internal to the shell. Tubes can be cleaned mechanically, chemically, water blasted or steam cleaned. The design of these units forces an even number of tube side passes therefore they suffer the same service restrictions as U bundles. Although in theory one pass unit can be designed, this is rarely done. These units are generally used in services where U bundles are not desired and the service may be too corrosive/damaging to the packing used in AEP/BEP units. NON REMOVABLE BUNDLE EXCHANGERS These types of units are often used in high pressure services and services where you wish to avoid leakage problems at gasketed joints. Another advantage is that they are generally more cost effective than removable bundle designs. NEU- The most cost effective design available. The tubesheet is welded to both the shell and bonnet. There is no access to the shell. Tubes may be chemically cleaned, water blasted or steam cleaned from inside only. These units are commonly used in high pressure services (such as feedwater heaters), where process conditions allow for even pass exchangers.

NEN- Tubesheets are welded to both the Shell & Bonnets. Access to the tubes is through covers on the channels. These units are favored in very high pressure designs as their construction minimizes the tubesheet thickness and number of high pressure retaining flanges. AEM/BEM/AEL-Shell side is completely welded up, however, the bonnets are removable. Chemical, mechanical, and water blast cleaning of the tubes is possible, however you do not have access to the shell. You should avoid using Steam cleaning on a fixed tube sheet unit unless the unit has a shell side expansion joint. The steam will cause the tubes to expand and pull out of the Tube Sheet causing failure at startup. DIFFERENTIAL THERMAL EXPANSION Since the duty of heat exchangers includes the handling of fluids of differing temperature, flow rate and thermal properties, differential expansion of the metals will take place. When the terminal temperature difference between the fluids is substantial, over 50-60 degrees, these stresses can become severe, causing shells to become deformed and damage mounting supports, tubes to deform the tube sheet or tubes to become broken or dislodged from the tube sheet. Fixed tube sheet designs are most vulnerable to differential thermal expansion, because there is no inherent provision to absorb the stresses. One approach in common use is installing an expansion joint in the shell pipe of such designs. This is a cost effective approach for pipe-size shells. An expansion joint can also be installed in the tube side of floating head designs, but Diagram of U-Tube Heat Exchanger manufacturing costs are much higher. Alternative approaches involve the design of a U-tube bundle so that each tube can independently expand and contract as needed or by using a rear floating internal tube sheet design which allows the entire bundle as a unit to expand and contract. The floating head is typically sealed against the interior of the shell by means of packing or O-ring designs. U-tube designs while offering the best answer for differential thermal expansion have some drawbacks. Individual tubes can be difficult of expensive to replace, especially for interior tubes. Also, the tube interior cannot be effectively cleaned in the u-bends. Erosion damage is also frequently seen in the u-bends in high tube side velocity applications. In large diameter shells, the long length of unsupported tube in the u-bends of outer tubes can lead to vibration induced damage. FLOATING HEAD DESIGNS OF HEAD EXCHANGERS In an effort to reduce thermal stresses and provide a means to remove the tube bundle for cleaning, several floating rear head designs have been established. The simplest is a "pull-through" design which allows the tube bundle to be pulled entirely through the shell for service or replacement. In order to accommodate the rear head bolt circle, tubes must be removed resulting in a less efficient use of shell size. In addition, the

missing tubes result in larger annular spaces and can contribute to reduced flow across the effective tube surface, resulting in reduced thermal performance. Some designs include sealing strips installed in the shell to help block the bypass steam. Another floating head design that partially addresses the above disadvantages is a "split-ring floating head". Here the floating head bonnet is bolted to a split backing ring instead of the tubesheet. This eliminates the bolt circle diameter and allows a full complement of tubes to fill the shell. This construction is more expensive than a common pull through design, but is in wide use in petrochemical applications. For applications with high pressures or temperatures, or where more positive sealing between the fluids is desired, the pull-through design should be specified. Two other types, the "outside packed lantern ring" and the "outside packed stuffing box" designs offer less positive sealing against leakage to the atmosphere than the pull though or split ring designs, but can be configured for single tube pass duty. SHELL CONSTRUCTIONS The most common TEMA shell type is the "E" shell as it is most suitable for most industrial process cooling applications. However, for certain applications, other shells offer distinct advantages. For example, the TEMA-F shell design provides for a longitudinal flow plate to be installed inside the tube bundle assembly. This plate causes the shell fluid to travel down one half of the tube bundle, then down the other half, in effect producing a counter-current flow pattern which is best for heat transfer. This type of construction can be specified where a close approach temperature is required and

when the flow rate permits the use of one half of the shell at a time. In heat recovery applications, or where the application calls for increased thermal length to achieve effective overall heat transfer, shells can be installed with the flows in series. Up to six shorter shells in series is common and results in counter-current flow close to performance as if one long shell in a single pass design were used. TEMA G and H shell designs are most suitable for phase change applications where the bypass around the longitudinal plate and counter-current flow is less important than even flow distribution. In this type of shell, the longitudinal plate offers better flow distribution in vapor streams and helps to flush out non-condensables. They are frequently specified for use in horizontal thermo-siphon re-boilers and total condensers. Heat Exchanger TEMA type AES

TEMA J Shells are typically specified for phase change duties where significantly reduced shell side pressure drops are required. They are commonly used in stacked sets with the single nozzles used as the inlet and outlet. A special type of J-shell is used for flooded evaporation of shell side fluids. A separate vapor disengagement vessel without tubes is installed above the main J shell with the vapor outlet at the top of this vessel. The TEMA K shell, also termed a "Kettle Reboiler" is specified when the shell side stream will undergo vaporization. The liquid level of a K shell design should just cover the tube bundle, which fills the smaller diameter end of the shell. This liquid level is controlled by the liquid flowing over a wier at the far end of the entrance nozzle. The expanded shell area serves to facilitate vapor disengagement for boiling liquid in the bottom of the shell. To insure against excessive liquid carry-though with the vapor stream, a separate vessel as described above is specified. Liquid carry-through can also be minimized by installing a mesh demister at the vapor exit nozzle. U-bundles are typically used with K shell designs. K shells are expensive for high pressure vaporization due to shell diameter and the required wall thickness.

The TEMA X shell, or crossflow shell is most commonly used in vapor condensing applications, though it can also be used effectively in low pressure gas cooling or heating. It produces a very low shell side pressure drop, and is therefore most suitable for vacuum service condensing. In order to assure adequate distribution of vapors, X-shell designs typically feature an area free of tubes along the top of the exchanger. It is also typical to design X shell condensers with a flow area at the bottom of the tube bundle to allow free condensate flow to the exit nozzle. Careful attention to the effective removal of noncondensables is vital to X-shell constructions.