Data Sheet. Portable Appliance Testing



Similar documents
Maintaining portable electric equipment in low-risk environments

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

Inspection and testing of portable electrical equipment

Electrical safety and you

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

Maintaining portable electrical equipment

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Heading FACT SHEET. Overview.

Experts in what we do. Portable Appliance Testing A Practical Guide.

Section B: Electricity

Safety & Environmental Protection Services Guidance Note

Portable Electrical Appliance Inspection and Testing Policy

PAT Tester Printers and Barcode Scanners

RCD Inspection Log Book

Handheld portable appliance testers

St Peter s College ELECTRICAL SAFETY. B. University Safety Office Policy Statement S4/10, Working safely with Electricity.

This Guideline does not address electrical equipment in the following categories:

Electrical Safety Policy

Tutorial on Safety Standard Compliance For Hipot Testing

rigel 288 Electrical Medical Safety Analyser Key Features Applications

THE INSPECTION OF PORTABLE ELECTRICAL EQUIPMENT

User Guide. Model Insulation Tester / Megohmmeter

Unit 4: Electricity (Part 2)

Power presses: A summary of guidance on maintenance and thorough examination

Leading the world in PAT testing solutions. Experts in what we do.

PAT400 Series. Portable Appliance Testers. User Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Electrical Safety Tester Verification

Electrical test equipment for use on low voltage electrical systems

FREQUENTLY ASKED QUESTIONS TESTING AND TAGGING OF ELECTRICAL EQUIPMENT

Electrical Resistance Resistance (R)

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

NZQA registered unit standard version 6 Page 1 of 5. Demonstrate and apply knowledge of safeguards for use with portable electrical appliances

Circuit Electrical Testing

Electrical Practices for Construction Work

Leading the world in PAT testing solutions

October Safety Subject

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Test Before Touch Easier Said Than Done. Ken Crawford, DuPont Kent Haggerty, Dupont

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

User s Manual Before using the inverter, you need to read and save the safety instructions.

Polarity. Electrical Quals

A Guide to 17th Edition Testing

PAT120, PAT150 and PAT150R Handheld portable appliance testers

ELECTRICAL PRACTICES FOR CONSTRUCTION WORK

7 FUNCTION DIGITAL MULTIMETER

Does a landlord have to have an electrical inspection carried out?

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Electrical safety for entertainers

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

3M Wrist Strap and Footwear Tester 740. User s Guide

Automated Contact Resistance Tester CR-2601

Seven function digital multimeter

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

User's Guide. True RMS Industrial Multimeter

INFRARED QUARTZ WALL HEATER

Technical Update TAA.TU Rev. 1

MEGGER Insulation & Low Resistance Tester

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Users Manual. Appliance Tester

Electrical Hazards. Power Tools. Extension Cords

Ground Resistance Clamp On Tester

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Owner s Manual & Safety Instructions

What equipment needs RCD protection? 3. Testing and tagging of electrical equipment 6. Protectively earthed and double insulated equipment 8

User Guide. HDMI Active Cable Extender. DVI-7370c

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

Arc Fault Circuit Interrupters Frequently Asked Questions

GUIDANCE ON ELECTRICAL INSPECTIONS

Current Monitoring Kit

Fire Protection Notice No. 9 ELECTRICAL SAFETY

ADM1TE 5/30A DIN rail single phase two wire energy meter

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

Advantium 2 Plus Alarm

Instructions for Safe Use

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Mini-led spotlight with magnetic base

chapter8 Testing and commissioning Unit 2 outcome 2

ELECTRICAL SAFETY RISK ASSESSMENT

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

AutoRanging Digital MultiMeter

Title: Grounding and Bonding Rev-01

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

In the context of this document, the following definitions apply:

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

ELECTRICAL TESTING PROCEDURE

How To Use A Power Supply Unit (Upu)

Model 1756 Test Lead Kit

Electrical Safety Tips. Help us keep you safe

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Please read operating instructions carefully before use and keep for further reference.

HP UPS R1500 Generation 3

Seaward Supernova. Portable Appliance Tester. Instruction Manual. September Seaward Electronic Ltd. Issue 6

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

Home Working Policy Version Date Status Comments

Transcription:

Data Pack A Issued March 2003 1502621615 Data Sheet Portable Appliance Testing Why is appliance safety inspection and testing required? A quarter of all serious electrical accidents involve portable electrical appliances. There is a requirement for an employer, and those renting, re-selling or repairing portable appliances to take adequate steps to protect the users of those appliances from both electrical shock and fire hazards. The HSE claim nearly 2000 fires in 1991 were caused by faulty leads to appliances. To meet the requirements of the 1989 Electricity at Work Regulations it is widely regarded to be necessary to implement a programme of planned inspection and testing of portable appliances. This application note should help to implement such a programme. Who is responsible for portable appliance safety? The responsibility for safety applies equally to small firms (including the self employed) as to the larger organisations. In addition to being responsible for the safety of their own portable applications they are also responsible for those bought onto site by employees or contractors. The Electricity at Work Regulations place a duty upon employers, the self-employed and employees, to ensure that the risks associated with the use of electrical equipment are controlled. The HSE Memorandum of Guidance on the Electricity at Work Regulations implies that the above duty holders have a responsibility to maintain electrical equipment to ensure that it remains safe. The requirement upon duty holders with regard to portable appliances, have been enlarged upon by the HSE guidance note HS(G)107 Maintaining Portable and Transportable Electrical Equipment and their leaflets Maintaining Portable Electrical Equipment in Offices and Other Low Risk Environments and Maintaining Portable Electrical Equipment in Hotels and Tourist Accommodation. The HSE recommend in these documents that a three level system of inspection can give cost effective maintenance of portable appliances, these are: 1. User checking 2. Formal visual inspections by an appointed person 3. Combined inspection and testing by a competent person or contractor. Safety of appliances The user of an electrical appliance is protected from electrical shock using basic methods, insulation and earthing. These are used to prevent the user coming into contact with a live electrical part. For insulation to be effective it must offer a high resistance at high voltages. For earthing to be effective it must offer a low impedance to any potentially high fault current that may arise. A principle of electrical safety is that there should be two levels of protection for the user. This leads to two classes of portable appliances: Class 1 which uses earthing + insulation (earthed appliance) and Class 2 using insulation + insulation (commonly called double insulated). The inspection and testing for Class 1 and Class 2 appliances therefore differ to suit the type of protection. What levels of inspection and testing are required? The level of inspection and testing required is dependant upon the risk of an appliance becoming faulty (dangerous), which is in turn dependant upon the type of appliance, the nature of its use and the environment in which it is to be used. The HSE indicate the following factors to consider in making such a risk assessment: The type of equipment and whether or not it is hand held Manufacturer s recommendations Initial integrity and soundness of equipment Age of the equipment Working environment in which the equipment is to be used (e.g. wet or dusty) or likelihood of mechanical damage Frequency of use and the duty cycle of the equipment Foreseeable abuse of the equipment Effects of any modification or repairs to the equipment Analysis of previous records of maintenance, including both formal inspection and combined inspection and testing. Where a duty holder is unable to make a judgement on the above criteria the HSE have provided guidance of the initial frequencies of inspection and testing that can be used to implement a maintenance programme. Alternately advice can be sought from a competent person. Note: Extension leads should be treated as electrical appliances.

Table 1 HSE suggested initial internals Type of business Formal visual Combined inspection inspection and electrical tests Equipment hire Before issue/ Before issue After return Construction Before initial use- 3 months 1 month Industrial Before initial use- 6-12 months 3 months Offices and other low risk See table 2 environments Table 2 HSE suggested initial intervals for offices and other low risk environments The guidance given in these tables is accompanied by a note to the effect that the inspection and test intervals should be reviewed in the light of experience, as information on faulty equipment is accumulated. Where equipment is repaired testing is considered to be necessary to re-affirm its safety. Formal Combined Equipment/ User visual inspection Environment checks inspection and testing Battery-operated No No No (less than 20 Volts) Extra low voltage: No No No (less than 50Vac) e.g. telephone equipment, low voltage desk lights Information No Yes, No if double technology: 2-4 years insulated - e.g. desktop otherwise computers, up to 5 years VDU screens Photocopies, fax No Yes, No if double machines: NOT 2-4 years insulated - hand-held. otherwise Rarely moved up to 5 years Double insulated No Yes, No equipment: NOT 2-4 years hand-held. Moved occasionally, e.g. fans, table lamps, slide projectors Double insulated Yes Yes, No equipment: 6 months HAND-HELD e.g. - 1 year some floor cleaners Earthed equipment Yes Yes, Yes, 1-2 years (Class 1): e.g. 6 months electric kettles, - 1 year some floor cleaners Cables (leads) Yes Yes, Yes, 1-5 years and plugs connected 6 months depending on to the above. - 4 years the type Extension leads depending on of equipment (mains voltage) the type of it is equipment it is connected to connected to Who is able to undertake the inspection and testing? Since there are three levels of maintenance action in the HSE recommendation there are implications with regard to the level of knowledge required by those undertaking the responsibility. User checks Since users are expected to visually check that the equipment they intend to use appears safe, they will need to be aware of the possible signs that might indicate a defect. Use of a potentially hazardous appliance can then be avoided by having it bought to management attention. This may require some initial training. Users of portable appliances should be aware of the following possible dangers: Damage to the power lead insulation Damage to the plug i.e. bent pins, signs of overheating or cracked case Poor cable retention i.e. cable is loose at either end or the inner insulation is showing Badly made joints within the power lead Damage to the casing of the equipment i.e. cracks, loose parts, screws missing, melted plastic Excessive dirt on equipment or water on equipment Evidence of overheating e.g. burn marks or discolouration. Formal visual inspections These require a competent person who has been trained to carry out a visual inspection, and possibly capable of checking the fuse and wiring within the plug. The HSE recommend that simple written guidance is given relating to this visual inspection, and that the person carrying out these tasks should know the limit of their knowledge so as to avoid danger. Such formal visual inspection for potentially dangerous appliances, enables the effectiveness of user checks to be monitored. Combined inspection and testing Since not all dangerous faults on equipment can be found with just visual inspection, appliance testing is often also necessary. If there is a suspicion that an appliance is not safe, but it looks OK visually After any repairs, modifications, or other similar work At a scheduled inspection and test (after a period determined by a risk assessment). Such inspection and testing should not only include testing with a portable appliance tester but should include: Checking the polarity, the fusing and termination of the mains flex. Inspection and testing also affords the opportunity to review again the suitability of the appliance to its environment and the frequency of inspection and testing. The HSE defines two levels of competency for appliance testing, dependant on the type of appliance tester used. 2

When a person is using a pass/fail style appliance tester (PAT) and no interpretation of the readings is required, the person need not be skilled in electrical work, but must understand how to operate the PAT correctly and understand acceptance criteria. The other level of competence is where a PAT with a readout requiring interpretation is used. When the person would need to be technically competent through knowledge or experience. Documentation of the inspection and testing Although there is no specific requirement for maintenance records to be documented, within the Electricity at Work Regulations it is widely accepted that some form of recording results is necessary to implement a control system. The control system recommended should include: 1. Ensuring that appliance inspection and testing is someone s specific responsibility 2. Keeping a log book or register of portable appliances and keeping a record of inspection/test results, in order to ensure that all equipment is inspected when due 3. Labelling equipment when tested with a due date for its next inspection or test. It is essential that any appliance that fails a safety inspection or test is removed from circulation, and labelled as not suitable for use. Some form of record system using a computer or index cards may be required to ensure a workable system when a large numbers of appliances are to be registered. Appliance testing log sheet A sample log sheet is shown later in this data sheet. The log sheet is free of copyright and may be copied for use in a regular planned inspection and testing system. Software for a testing programme For medium and large sites where portable appliances are more numerous, the requirements of the Electricity at Work Regulations can be more easily implemented by the use of a computerised system. One such is Safety 1st (RS stock no. 203-079), which runs on an IBM PC/AT/PS2 or compatible computer with 640k of RAM and a hard disk. This system holds a description of each appliance plus the inspection and test frequencies. The system can than schedule both formal visual inspections and combined inspection and testing. It can produce monthly and/or weekly check lists of appliances due for testing for each location on site. A record of test results is then compiled from information keyed into the PC from the visual inspection or test report sheets, which are originated by the system and subsequently filled in by the person responsible for the inspection or testing. Additionally, test data can be input directly via an RS-232 interface from computerised portable appliance testers such as the Seaward PAT 1000, the Edgecumbe Micro-PATs or the Robin Smart PAT 5000. The Safety First system is able to produce a variety of reports to enhance the implementation of an appliance safety programme. These include equipment register, check lists, equipment history, failed equipment report and overdue inspection/test reports. The portable appliance tester The procedures for portable appliance safety testing require that electrical tests are carried out upon the appliances to confirm the integrity of the earthing and the insulation. To simplify this task a competent person can use a portable appliance tester (PAT) to perform these tests safely. Note: When testing an electrical appliance, for a test to be valid, ensure that it is switched on and that the fuse is intact. The unit under test is plugged into the socket on the PAT. Some tests are carried out through the plug, others through both the plug and an auxiliary probe to the casing of the appliance. The tests Two basic tests are offered by all appliance testers, these are: Earth bond test. Applies a substantial test current, typically around 25A*, down the earth pin of the plug to an earth probe which should be connected by the user to any exposed metalwork on the casing of the unit under test. From this the resistance of the earth bond is determined by the PAT. *Alternative lower current tests are offered on some appliance testers allowing low current consumption appliances to be tested without stressing the smaller earth conductors. A 100mA earth continuity test is offered by some PATs to enable shielding and nonfunctional earths to be verified without damage. Insulation test. Applies a test voltage, typically 500Vdc, between the live and neutral bonded together and earth, from which the insulation resistance is calculated by the PAT. Other tests offered include the following: Flash test. Tests the insulation at a higher voltage, typically 1.5kV for Class 1 appliances and 3kV for Class 2 appliances. From this test the PAT derives a leakage current indication. This is a more stringent test of insulation, that should be used with caution since it can cause damage to electronic equipment and may over-stress insulation. Load test, measures the load resistance between live and neutral to ensure that it is not too low for safe operation. Operation test. A further level of safety testing which proves the preceding tests were valid (i.e. the unit was switched on), ensures that an excessive current level is not drawn by the appliance and avoids the embarrassment of passing a non-working appliance. Earth leakage test. This is carried out during the Operation test as a further test of the insulation under its true working conditions. This test can also be useful to ensure that appliances are not responsible for nuisance tripping of RCDs. Fuse continuity test. This will test that the fuse is intact and that the appliance is switched on prior to carrying out other tests. 3

Testing earthed (Class 1) appliances The earth bond test is only used when testing earthed (Class 1) appliances. A test lead is clipped onto an exposed metal part of the unit under test. The test is then carried out by the PAT, usually at the press of a button. The test result should then be noted and recorded. The insulation test on an earthed appliance requires no additional test lead and is carried out via the plug. Again the test result should be noted and recorded. If a flash test is carried out this is also done via the plug once selected and activated. Double insulated (Class 2) appliances The earth bond test is not required. The insulation test uses a clip or probe which is held against the appliance body whilst the test is in progress. The results must again be read and recorded. A flash test if carried out uses an external probe held against the appliance body whilst the test is in progress. Once more the reading must be noted and recorded. Operating procedures are detailed fully in operators manuals supplied with the PATs. Further reading This data sheet only offers brief notes on appliance safety and maintenance, the following further reading is recommended for a more adequate understanding. Health and safety series booklet HS(R)25 Memorandum of guidance on the electricity at work Regulations 1989 (Available from: HMSO) HS(G) series booklet HS(G)107 Maintaining portable and transportable electrical equipment (Available from: HMSO) IND(G) series booklet IND(G)160L Maintaining portable electrical equipment in offices and other low risk environments (Available from: HMSO) FEI recommendations Issue 2, July 1994 for periodic safety checks for business equipment (Available from: FEI, Russell Square House, 10-12 Russell Square, London WC1B 5EE. Tel: 071-331 2000). RS supplies a range of self adhesive labels with pretitled legends. Examples from the range which may be useful when testing portable appliances are pictured below. Labels can be marked with ballpoint pen, typewriter or spirit based inks. Alternatively, partially laminated labels are available providing additional durability. Please see the drafting and marking equipment section in part 2 of the current RS Catalogue for stock numbers, prices and ordering information. RS can also supply pre-printed Bar-code labels for use with Seaward PATs in conjunction with Welch Allyn PAT barcode wand (RS stock no. 246-9007). Note: If used with a Seaward 1000/1500 series, a separate power supply and adaptor cable (RS stock no. 246-9057) is required. Please see the Electrical Test section in part 2 of the current RS Catalogue. BY ACCEPTED DATE Title colour: White on green background TESTED DATE INITIALS Title colour: White on green background REJECTED REASON DATE BY Title colour: White on red background DO NOT USE AFTER Title colour: White on red background TESTED FOR ELECTRICAL SAFETY BY DATE Title colour: White on green background EQUIPMENT NOT TO BE USED Title colour: White on red background 4

Portable appliance tester selection guide A quarter of all serious electrical accidents involve portable electrical appliances. There is a requirement for an employer, and those renting, repairing or re-selling appliances, to take adequate steps to protect the users of these appliances from both electrical shock and fire hazards. RS offers a full range of portable appliance testers (PATs) to choose from. This guide will make it easier to select the PAT that best suits your needs. Compatible with Welch Allyn Barcode Wand (RS stock no. 246-9007) Note: The RS Servicepoint Calibration is available for portable appliance testers supplied by RS to ensure that you are always testing accurately. For full details see your latest RS Catalogue. Robin Robin Edgcumbe Seaward Seaward Seaward Seaward Smart PAT Smart PAT Micro PAT+ PAT 2000i PAT 1000X PAT 1000S IT 1000 3000 5000 Earth bond Tests if the earth is OK. Earth resistance Yes Yes Yes Yes Yes Yes Yes test is tested with a test current @ 25A. Pass levels Pass levels Pass levels Pass levels Pass levels Pass levels Pass levels This test applies to earthed (Class 1) <0.1Ω <0.1Ω and <0.1Ω and <0.1 or 0.5Ω <0.1, 0.5 or <0.1 or <0.1 or appliances only. selectable selectable 2Ω 0.25Ω 0.15Ω Alternate low current earth bond test. Yes Yes Yes Yes Yes 0.1A & 8A 0.1A & 8A 0.1Adc and 0.1, 6, 12, 8A 8A 0.1, 6, 12, 25Aac 25A 20, 25A Insulation Tests if the insulation is intact. Yes Yes Yes Yes Yes Yes Yes test Insulation is tested with a test voltage of Pass levels Pass levels Pass levels Pass levels Pass levels Pass levels Pass levels 500Vdc at pass level. This test applies to <2,7MΩ <2,7MΩ 0.5,1.0, 2.0 >2, 7MΩ >2, 4, 7MΩ >2, 4, 7MΩ >2, 7MΩ both Class 1 and Class 2 appliances. and 7.0MΩ 0-19.9MΩ Fuse test Tests the fuse and also ensures that the P-N P-N P-N appliance is switched on, for subsequent test. Continuity Continuity Continuity Flash test Tests if the insulation will stay OK. Carried Yes Yes Yes Yes Yes out with a 1.5kV test voltage for Class 1 selectable Pass levels Pass levels Pass levels Pass levels and 3kV test voltage for Class 2 appliances. <3mA <3 or 5mA <3 or 5mA <3 or 6mA Load test Tests to ensure that the load impedance is Yes Yes Yes Yes safe to connect to the mains, i.e. not a short circuit. Often also used as confirmation the unit is switched on with fuse intact Operation A further level of safety checking to ensure Yes Yes Yes Yes Yes test an excessive level of current is not drawn. selectable Pass levels Pass levels Pass levels Functional Also avoids embarrassment of passing a readout 3.1kVA <0.5, 1, 2, <1, 2 or, test only up to <4kVA (240V) 3.2kW (240V) 3kW 1.43kVA or 1, 1.8kW (110V) (110V) Earth Tests that the earth leakage current is at an Yes Yes Yes Yes Yes leakage acceptable level. Useful to ensure appliance selectable Pass levels Pass levels Pass levels Pass levels test is not deteriorating and liable to become readout <0.75, <0.75, <0.75, 3.5, <0.75, unsafe. Also ensures that tested appliances 0.1-9.9mA 3.5mA 3.5mA 9.9mA 3.5mA are not responsible for nuisance tripping of RCDs. Test value readout Yes Yes Yes Yes Yes Yes Yes Digital Digital Digital Digital Digital Digital Digital display display display display display display display Pass/Fail indicators Yes Yes Yes Yes Yes Yes Yes indicated on indicated on indicated on indicated on indicated on indicated on indicated on the display the display the display the display the display the display the display Automatic test sequence Yes Yes Yes Yes Yes Selectable Selectable Selectable Selectable Selectable Dual 110 and 240 Volt version - RS stock number: 847-130 847-124 212-405 240 Volt version - RS stock number: 248-2870 Extension lead accessory - RS stock number: 203-833 203-833 203-833 203-833 5

Portable appliance tester selection guide (continued) * Both LV and HV flash test facilities provide Class 1 testing at 1kV and 2.5kV, and Class 2 testing at 1.5kV and 3.75kV. Note: RS Servicepoint Calibration Service is available for portable appliance testers to ensure that you are always testing accurately. For full details see your latest RS Catalogue. Megger Megger Seaward Seaward Seaward PAT 32 PAT 2 PAC 500 PAT 500H PAC 1500xi Earth bond Tests if the earth is OK. Earth resistance is tested with a Yes Yes Yes YES test test current @ 25A.This test applies to earthed (Class 1) Pass levels Pass level Pass level Pass level appliances only. <0.1Ω <0.5Ω Alternate low current earth bond test. Yes Yes Yes 0.1, 10A and 0.1Amps 0.1, 6, 12, 20 25A and 25Amps Insulation Tests if the insulation is intact. Insulation is tested with Yes Yes Yes Yes Yes test a test voltage of 500Vdc at pass level. This test applies Pass Pass level Pass level Pass level Pass level to both Class 1 and Class 2 appliances. >2,MΩ >2MΩ >2MΩ, >7MΩ >2MΩ, >7MΩ Fuse test Tests the fuse and also ensures that the appliance is Yes Yes switched on, for subsequent test. Flash test Tests if the insulation will stay OK. Carried out with a Yes* 1.5kV test voltage for Class 1 and 3kV test voltage for Pass level Class 2 appliances. <3mA Load test Tests to ensure that the load impedance is safe to connect Yes to the mains, i.e. not a short circuit. Often also used as confirmation the unit is switched on with fuse intact. Operation A further level of safety checking to ensure an excessive Yes test level of current is not drawn. Also avoids embarrassment Meter indication of passing a non-working appliance. 0-3.5kVA Earth Tests that the earth leakage current is at an acceptable level. Yes leakage Useful to ensure appliance is not deteriorating and liable to Range become unsafe. Also ensures that tested appliances are 0-20mA not responsible for nuisance tripping of RCDs. Test value readout Yes Yes Yes Yes Digital and Analogue Digital Digital Pass/Fail indicators Yes Via colour Yes Yes Yes indicated on bands on Indicated on the display Automatic test sequence Dual 110 and 240 Volt version - RS stock number: 219-579 240 Volt version - RS stock number: 287-3068 159-1771 Extension lead accessory - RS stock number: 219-585 Megger Megger Megger Edgcumbe Seaward Pat 32 Pat 4DV Pat 4DVF D2112 Supernova Earth bond test Yes Yes Yes Yes Yes Pass levels Pass levels Pass levels Reading Pass level 0.1, 0.5mW selectable selectable only range selectable 0.05 to 2W 0.05 to 2W 0-1.99 Yes Yes Yes Yes Yes 0.1A, 10A 0.1A, 10A 0.1A, 10A 0.1Adc, 8Aac 0.1A, 4A and 25A and 25A and 25A and 25Aac 10A and 25A Insulation test Yes Yes Yes Yes Yes Pass levels Pass levels Pass levels Reading Pass levels 2 and 2MW 2 and 2MW 2 and 2MW only selectable Fuse test Yes Yes Yes Test plug top and Test plug top and Test plug top and appliance fuses appliance fuses appliance fuses Flash test Yes Yes Yes Pass levels Pass levels Pass levels 0.2-3mA 19.0mAac selectable Load test Yes Yes Yes Yes Tests to circuit Test to circuit continuity, short continuity, short circuit and circuit and open circuit open circuit Operation test Yes Yes Yes Yes Pass levels Pass levels reading only selectable selectable 50-3000VA 50-3000VA Earth leakage test Yes Yes Yes Yes Pass levels Pass levels Reading only Pass levels selectable selectable selectable 0.5-15mA 0.5mA 0-19.9mA Test value readout Yes Yes Yes Yes Full graphics Digital and Digital and Digital and Digital display on LCD analogue analogue analogue Pass/fail indicators Yes Yes Yes Reading for Yes Indicated on Digital display Digital display interpretati Indicated on display on by user display Automatic test sequence Yes Yes Yes User defined User defined Selectable Dual 110 and 240V versions 219-579 287-4415 287-4421 326-7363 240V version Extension lead accessory 203-833 6

Appliance testing log sheet Appliance description Formal visual inspection interval Serial number Location Inspection and testing interval Inspection date Visual/Combined Visual/Combined Visual/Combined Visual/Combined Visual/Combined Visual/Combined Visual/Combined (Delete as applicable) Tested by (block capitals) Power lead? Cable retention? Plug intact? Fusing correct? Casing intact? Visual check list Free of contamination Appliance switched on Earth bond test Ω Insulation test MΩ *Flash test ma *Load test VA PAT test results *Earth leakage test ma PASS or FAIL Recall date Next: Delete as applicable Visual/Combined Visual/Combined Visual/Combined Visual/Combined Visual/Combined Visual/Combined Visual/Combined Signature *Optional tests which may be carried out if available on your portable appliance tester. This page may be freely copied for recording your appliance inspection and test results. 7

The information provided in RS technical literature is believed to be accurate and reliable; however, RS Components assumes no responsibility for inaccuracies or omissions, or for the use of this information, and all use of such information shall be entirely at the user s own risk. No responsibility is assumed by RS Components for any infringements of patents or other rights of third parties which may result from its use. Specifications shown in RS Components technical literature are subject to change without notice. RS Components, PO Box 99, Corby, Northants, NN17 9RS Telephone: 01536 201234 An Electrocomponents Company RS Components 1998