OIL MIST SEPARATOR OENA-DM



Similar documents
Kompressoren. Adsorption Dryer AD

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Cooking at the Speed of light!

Series description: Wilo-Drain TC 40

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Backflush filter R8-30W

The ACCU-LUBE Micro-Lubricating System for external and internal lubrication

UNITOR ULTRASONIC cleaning

Rotary screw compressors kw 5,5 7, , bar MODULO

CoolTeg Plus Chilled Water (CW) version: AC-TCW

A Guide to Trouble-Free Cooling Towers

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Thermostatic valve Type AVTA

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Automatic Back-Flushing Filter AutoFilt RF9.

Medical Air Systems: Scroll

Fixed displacement vane pumps

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

MEMBRANE VACUUM MINI PUMPS

MECHANICAL MACHINING MINIPURE STATION FOR THE TREATMENT OF CUTTING AND PROCESS FLUIDS.

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

OIL-FREE ROTARY SCROLL COMPRESSOR. ECOLIFE 1,5 15 kw

912. The engine for construction equipment.

ECOCIAT. Domestic hot water heat recovery unit

COMPOSITE MESH PAD (CMP) DRY SCRUBBERS III TM ENFORCER III

RPV - RP - RA air handling units

Duplex Filters 40 FLDK 0008(C)-0120(C)

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Rotary Screw Compressors UP-Series 4 & 5.5 kw

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

For extraction technology and occupational health & safety

300 Series PA Pump and Cooler Assemblies

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Trouble Shooting. Pump

Manual Code VR

Technical data. Danfoss DHP-A

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Hydraulic control unit series

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

EcoCWave. The all-round talent for aqueous part cleaning.

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

ThermoSorb Desiccant Dryers

WASTE WATER TREATMENT for surface treatment applications

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

SWIMMING POOL HEAT PUMP Owners Manual

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH INNOVATIONS FOR POWERFUL PERFORMANCES

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Advantages and application of PCD and CBn tools

PLUG and PLAY VRV Connection

HVAC Checklist - Long Form

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

LED MACHINE ILLUMINATIONS

Boiler and Burner Cleaning and Servicing Specifications

6 Crankcase Ventilation

NORMAN FILTER COMPANY PRODUCT OVERVIEW

API Flanged Safety Relief Valves Series 526 CATALOG

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

HIGH PERFORMANCE FILTERS AND ELEMENTS

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Under sill units. Type FSL-B-ZAS

ALLROUNDER 420 C GOLDEN EDITION

swimming pool accessories

LABOKLAV. Autoclaves Made in Germany.

Atlas Copco Quality Air Solutions. Compressed Air Filters

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

FLSmidth ball mill for cement grinding

Transformer oil cooler ALFA A02

Do you remove fumes from robotic welding and laser cutting?

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents


Energy Efficiency HOSPITALITY.

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

SECTION MORTUARY REFRIGERATORS

Asbestos Work Permit Procedures

Transcription:

CLEAN AIR FOR INDUSTRY. OIL MIST SEPARATOR OENA-DM THE TASK Our OENA-DM series oil mist separators are used in cutting and shaping metalworking processes for scrubbing non water-soluble cutting fluid aerosols based on mineral, organic and synthetic oils. Reusable plastic mesh filter elements and fine-fiber material provide high-efficiency filtration of cooling lubricant aerosols. Our product lineup includes a graduated series of systems with air volumes up to 20,000 m³/h, which can be customized to even larger airflows due to their modular design. THE SEPARATION PRINCIPLE Multiple stage separation process Reusable plastic mesh filter elements and fine-fiber material Separation is achieved by a combination of inertia, screening effect, coalescence and diffusion APPLICATIONS Cutting processes such as drilling, turning, milling, broaching, honing, grinding Shaping processes such as rolling, deep drawing, pressing Machine tools, machining centers and transfer systems for cutting processes Rolling mills for sheet metal and steel, light alloys and heavy non-ferrous metals Presses for molding and deep drawing parts made of steel, light alloys or non-ferrous metals

HOW IT WORKS The untreated/contaminated air enters the air inlet chamber (1) where gravitational separation removes large droplets from the air. The incoming air flow is captured in filter stage 1 (4) and is directed on to the second filtration stage (5). Both filters are reusable. 8 1 Inlet chamber for untreated air 2 Clean air outlet 3 Drain 4 Filtration stage 1 5 Filtration stage 2 6 Spray nozzles 7 Drain basin 8 Fan 9 Fill level monitoring The separator is preconfigured for optional automatic rinsing, which can be activated to prevent excessive contamination of the filter media. Oil is added via an electro-pneumatic ball valve during, before or after operation of the oil mist separator. Spray nozzles (6) spray the oil on the first filtration stage (4) to flush away dirt. The separated oil mists and the rinsing agent run through the first filtration stage (4) onto the slanted floor basin (7) and exit the unit through the drain (3) with integrated siphon. 2 Depending on the operating conditions, the separated oil can be either reused in the machine or be pumped into a reconditioning unit. The filtration stages can be easily checked by opening the access doors. Filter elements can be removed for cleaning or exchange if necessary. 5 6 A top-mounted radial fan (8) or an external fan provides the necessary air flow and pressure differential. 4 After passing through the filtration stages, the cleaned air exits the unit via the fan or clean air outlet and can then be recirculated into the workplace or ducted to the outdoors, depending on workplace conditions and clean air regulations (Recirculation or vented air operation). 1 7 9 Depending on applicable noise regulations, installation of an exhaust silencer at the fan outlet might be required. 3 2

FILTER ELEMENTS Reusable plastic mesh filter elements and fine-fiber material. AUTOMATIC CLEANING OF FILTER ELEMENTS The separators are preconfigured for optional automatic rinsing. The cleaning process can be configured individually to fit the specific application. It can be activated with a solenoid valve during operation (short intervals) and after the filter unit has been turned off. Oil serves as the cleaning fluid which nozzles spray onto the surface of the filter elements. The backwashing process can also be controlled manually in Manual Operation mode. DISPOSAL The separated oil is collected in the floor basin of the unit and is then reintroduced into the oil supply cycle of the machine via a return pipe, or removed for reconditioning. The return pipe must be vacuum sealed either by using a siphon or by immersing it in the coolant sump by at least 300 millimeters. PLACEMENT The units are designed for indoor installation. Placing the units outdoors is possible if taking special precautionary measures. ELECTRICAL SYSTEM The electrical controls of the system meet both VDE and our own demanding Keller standards. We will also build to customer specifications. ACCESSORIES Preliminary chip separator Tramp oil separator Electro-pneumatic ball valve Fill level indicator Floor basin made from stainless steel (1.4571) Leakage sensor Tank with pump for separated cooling lubricants FAN UNIT Depending on the placement of the unit, the air volume and the required pressure differential, every configuration of the oil mist separator is available either with an external fan or with a top-mounted fan for compact overall dimensions. RECIRCULATION OF EXHAUST AIR The highly efficient separation of aerosols frequently allows the cleaned air to be re-circulated into the workplace. Higher concentrations of gaseous components present in the cleaned air must be ducted outdoors. As an alternative, an additional cleaning stage (cooling and condensation, or adsorption filter) is possible. 3

UNIT DIMENSIONS AND TECHNICAL SPECIFICATIONS OENA-DMV Please refer to illustrations below for details. H H 2 B 1 A E H 1 C B 1 F D B OENA-1-DM OENA-2-DM OENA-3-DM OENA-4-DM OENA-5-DM B 1000 x 1200 1200 x 1200 1600 x 1600 2000 x 2000 2400 x 2400 H 1750 2650 2750 2650 2650 H1 650 650 650 650 650 H2 1535 2280 2280 - - A 1100 1100 1500 1900 2300 B1 125 250 350 400 450 C 1300 1300 900 1300 1300 D - - - 400 450 E - - - 1360 1600 F - - - 640 640 Untreated Air Inlet left/right left/right left/right left/right left/right Clean Air Outlet left/right left/right left top* top Rated Air Volume m³/h 3500 5000 10000 15000 20000 Spray Nozzles 1x 2x 6x 8x 8x Weight in kg 410 650 1100 1800 2200 Subject to modifation *) left/right also possible then A=1300, B1=250, H2=2330 4

UNIT DIMENSIONS AND TECHNICAL SPECIFICATIONS, OENA-DMV Please refer to illustrations below for details. 100 H H 2 A 250 H 1 C B 1 B OENA-1-DM-2.5/3.5V OENA-2-DM-5.0V OENA-3-DM-10V OENA-4-DM-15V OENA-5-DM-20V B 1000 x 1200 1200 x 1200 1600 x 1600 2000 x 2000 2400 x 2400 H (overall with optional silencer) 2300 3270 3550 3500 3740 H1 650 650 650 650 650 H2 1700 2600 2700 2650 2650 A 1100 1100 1500 1900 2300 B1 125 250 350 400 450 C 1300 1300 900 1300 1300 Untreated Air Inlet left/right left/right left/right left/right left/right Clean Air Outlet 0 /90 /180 /270 0 /90 /180 /270 0 /90 /180 /270 0 /90 /180 /270 0 /90 /180 /270 Engine Power Output kw 4 5,5 11 18,5 30 Sound Pressure Level db (A)* 75 75 77 79 79 Air Volume rated at m³/h 2500/3500 5000 10000 15000 20000 Spray Nozzles 1x 2x 6x 8x 8x Weight in kg 570 820 1310 2180 2850 Subject to modification *) measured at a distance of 1 m from the unit (door), measured according to DIN EN ISO 3744 5

COMPACT SEPARATION TECHNOLOGY OIL MIST SEPARATOR OENA-K HIGHLY EFFICIENT SEPARATION FOR METALWORKING APPLICATIONS With the oil mist separators of the OENA-K series, Keller Lufttechnik has developed a compact unit for capturing and separating cooling lubricant aerosols created by mineral, organic, and synthetic oils. This unit can be used as an independent unit or situated on top of or adjacent to a machine tool. The control of the separator can be effected directly via the machine. As an alternative, we have a range of controls available. They can either be attached to the system or delivered separately. For this purpose we dispose of plug-type connections in different lengths. SEPARATION PRINCIPLE A multi-stage separation process cleans the untreated air using a combination of inertia, screening effect, coalescence and diffusion. The composition of the reusable wire mesh filter elements and fine-fiber material is customized to separate the specific droplet spectrum of the application. As an option, a third filtration stage (for the separation of fumes and smoke) can be added. ACCESSORIES Downstream Filter Spraying of filtration stage 1 APPLICATIONS Cutting processes such as drilling, turning, milling, broaching, honing, grinding Shaping processes such as rolling, deep drawing, pressing Machine tools, machining centers and transfer systems for cutting processes Rolling mills for sheet metal and steel, light-alloy and non-ferrous metal profiles Presses for molding and deep-drawn parts made from steel, light-alloy or non-ferrous metals Die casting machines Grinding machines ADVANTAGES Small and compact filter housing Machine top mounting possible Switch and control system loosely or attached Turnable by 180º 24-hour operation with option to rinse during operation No downtime required 6

Clean air outlet Untreated air inlet Clean air outlet 636 Ø 250 1400 407 610 OENA-K OENA-1-K-1.0 OENA-1-K-2.0 OENA-1-K-2.0 NW untreated air inlet Ø 250 Ø 250 Ø 250 Optional 3. Filter Stage B1 [mm] 407 407 407 Untreated Air Inlet left/right left/right left/right Clean Air Outlet right/left right/left right/left Engine Power Output kw 1,5 3,3 3,3 Sound Pressure Level db (A)* 72 72 72 Air Volume rated at m³/h 1000 1500 1000** Spray Nozzles 1x 1x 1x Weight in kg ca. 175 ca. 175 ca. 175 Subject to modification * measured at a distance of 1 m from the unit (door), measured according to DIN EN ISO 3744 ** Separator for finer aerosol mist with increased filtration stage 2 7

CLEAN AIR FOR INDUSTRY. REFERENCES END COSTUMERS ACI, France AUDI, Germany, Hungary BMW, Germany, Great Britain, Austria BOSCH, Stuttgart CONTINENTAL TEVES, Gifhorn DAIMLER, Germany, Mexico DEUTZ, Köln FEDERAL MOGUL, Germany FORD, England, Germany, Brasilia, Spain, Mexico GETRAG, Germany, England, Slovakia, France GM, Germany HÄRING, Bubsheim MTU, Friedrichshafen, Munich OPEL, Germany, Austria, Hungary PEUGEOT, France PORSCHE, Germany SEAT, Spain VW, Germany, Mexico, China, Belgium VISTEON, Germany DODGE EUROPE ELZTAL, Dallau EKERT HERMANN GMBH, Sulzbach HEIDELBERGER DRUCKMASCHINEN, Wiesloch HEYLIGENSTAEDT, Giessen HFP BANDSTAHL, Salzungen HIRSCHVOGEL KOMPONENTEN, Schongau PELTEP, Poland REFERENCES MACHINE MANUFACTURERS GROB, Mindelheim CHIRON, Tuttlilngen DMG, Burscheid INDEX, Esslingen MAG POWERTRAIN, Eislingen TRAUB, Plochingen EMAG Maschinen, Salach EMAG Leipzig GmbH, Leipzig WEISSER, St. Georgen Keller Lufttechnik - all rights reserved. Subject to modifications. 07/2008 www.loerz-company.de Keller USA, Inc. 54 Great Hill Road, P.O. Box 546 Naugatuck, CT 06770 USA Phone (203) 729-0145. Fax (203) 729-0148 E-mail: info@kellerusa.com www.kellerusa.com