Building Technologies. Thermostats and room controllers. General Product range overview Thermostats



Similar documents
RDG/RDF room thermostats

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Building Technologies. Electronic Thermostats and Controllers Selection Guide

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Heating Controller. Building Technologies HVAC Products

HVAC Processes. Lecture 7

HVAC and Lighting Control Products for Open Building Automation Systems

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

Controls for fan coil units and cassettes

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

features Electric Room Thermostats Description Applications Thermostats & Hygrostats

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

Thermostat with display

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Building Technologies

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Adjustable room thermostat for heating only or cooling only systems

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil

Variable Air Volume - VAV

T5000 T000 LCD Digital Fan Coil Thermostat

Impact of Control System Technologies on Industrial Energy Savings

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T


DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

SMART COMFORT & EASY EFFICIENCY HEATING CONTROLS

Mixing Valves. ARGUS Application Note: Mixing Valves

Condensing Boiler Efficiency

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Lesson 36 Selection Of Air Conditioning Systems

UNIFIED FACILITIES GUIDE SPECIFICATIONS

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Inwall Room Temperature Unit

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

Data sheet Thermostatic sensors type RA 2000

Flush-mounted room thermostats

HCE80/HCC80/HCE80R/HCC80R

RF 1. Contents: Connecting diagram. Detailed information:

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Thermostats. comfort at your command

CGC s Hybrid System Loop Control

Technical Guide. Thermostats Air Conditioning

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

for Plans Examiners and Building Inspectors

Room thermostats wide variety and high energy efficiency

OZW30. Central Unit SYNERGYR

RRV934. Multi-controller. Synco living

3466 Building Energy Management Training Systems

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Energy Efficiency HOSPITALITY.

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

HEATING, VENTILATION & AIR CONDITIONING

HVAC Systems in Schools & Commercial Buildings and Radon

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HERZ-Thermal Actuators

Electronic Control Devices The European Product Catalogue 2007

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Heating and Hot Water Services Controls General Technical Specification

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

PART 11: START-UP PROCEDURES FOR THE INSTALLER

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

INSTALLATION AND OPERATION MANUAL

Building Energy Systems. - HVAC: Heating, Distribution -

Electric Flow Boiler

Introduction to Building Automation Systems (BAS)

Commercial Refrigeration Temperature and Defrost Controls

Air Conditioning Clinic

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

Air-conditioning controller. User's Manual NRT 107 F031, F R R2 Sauter Components

Wireless Thermostats 230v and Battery Operated Instruction Manual

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

User Manual THR840DUK Digital Thermostat

Product catalog UNT-PRC011-E4

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

Printing and Publishing Energy Savings Guide

Hotel System Management The Hotel Smartest Solution

Technical Support Bulletin Nr. 20 Special AC Functions

ECOCIAT. Domestic hot water heat recovery unit

Automatic control equipment for HVAC systems

Aerona Air Source Heat Pumps

PNEUMATIC CONTROLS Selection and Description

Fundamentals of HVAC Control Systems

Answers for infrastructure. HVAC control with Synco simple and energy-efficient

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Why and How we Use Capacity Control

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Thermostatic Actuators

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Transcription:

9 Building Technologies Thermostats and room controllers General Product range overview Thermostats

General Thermostats overview The thermostat range of Siemens includes products for individual room control, for pipe- and duct-mounting and frost protection. The new thermostat range has arrived Consisting of 16 families, the range covers almost every commonly encountered application in heating, cooling or ventilation. It offers an unbeatable price/performance ratio and is presented in a unified and elegant design. Applications include low voltage (AC 230 V) and extra low voltage (<AC 50 V). All devices meet the requirements for CE marking. Selection criteria Heating only/ cooling only RAA RCU10 RCU10.1 REV300 RDD RDE REV33 RAV REV12, REV16, REV23, REV26, REV100, REV200 REV23M TRG2 RAK -TR -TW Heating, cooling and ventilation RAB RCC RCC50.1 RCC60.1 RDF RDF50.1 RDF60.1 Heat pump RDX RCU20 RCU60.. RCU61.. RDU Monitoring QAF81 RAZ QAF63/64 RAK -ST -TB ON/OFF control Modulating control (3-position, D...10V, communication) 9-2

Product range overview Made-to-measure control solutions Cost-effective application-specific products are available for mostly non-communicating individual room control with Heating/cooling Fan-coil units Variable air volume systems (VAV) Air ducts The products operate in standalone mode. For fan-coil units, the range includes simple ON/OFF products and versatile products with two proportional sequences and automatic fan control. For heating only and/or cooling only, a wide range of products are available from a simple mechanical controller up to a 3-position controller with touchscreen interface. For the monitoring of heating systems, domestic hot water heating and frost protection in air ducts, different variants of the RAK/RAZ and QAF families are available. Heating only/cooling only The RAK/RAZ product family The electromechanical capillary tube thermostats RAK-TR, RAK-TW with integrated changeover contact are clamp-on thermostats and immersion thermostats in one. The RAZ-TW is a combination of RAK-TR and RAK- TW. All these thermostats convince by their robustness and installation friendliness. The RAA product family These electromechanical ON/OFF room temperature controllers are designed for the simplest heating and cooling applications. The RCU/RDU product family (universal) The RCU/RDU microprocessor-based room temperature controllers are designed for heating and cooling applications with 0 10 V, 3-position and ON/OFF field devices. RDU room temperature controllers have a digital display (LCD) and their additional functionality extends the variety of applications. The RDD product family The microprocessor-based room temperature controllers in the RDD product family have a digital display (LCD). They are available with a simple time setting facility. The controllers are designed for simple heating control with a 2-position control algorithm. Battery-powered and AC 230 V versions are available. The RDE product family The microprocessor-based room temperature controllers in the RDE product family have a digital display (LCD). They are available in a version with a 7-day program. These controllers were developed for simple heating control with a 2-position control algorithm. Battery-powered and AC 230 V versions are available. 9 The REV product family The programmable room temperature controllers REV.. have a digital display (LCD). They ensure optimum comfort in apartments and single-family homes, at the same time lowering costs by reducing energy consumption: for example, via the function «automatic optimization» (selflearning control algorithm). They are available in 24-hour or 7-day time programmable versions with options for remote switching (via telephone), touchscreen display, 3-position controlling, wireless connection between controller and receiver as well as connection to an «OpenTherm Plus» capable boiler. The RAV product family The programmable room temperature controllers RAV are ideal for users who prefer analog rather than digital operation. They ensure optimum comfort in apartments and single-family homes, at the same time lowering costs by reducing energy consumption: for example, via the function «automatic optimization» (self-learing control algorithm). Our range includes battery-powered RAV11. Based on the application, the RAV11.x is equipped with an analog 24-hour or 7-day time switch. 9-3

Range overview Heating and cooling The RAB product family The electromechanical ON/OFF room temperature controllers in the RAB family are designed specifically for fan-coil systems. They are used for control in simple 2- pipe and 4-pipe systems. The RCC product family The RCC room temperature controllers are based on microprocessor technology and are designed specifically for moderately complex to complex fan-coil systems. They can be used for 2-pipe and 4-pipe systems. The RDF product family with display RDF is a family of microprocessor-based fan coil controllers with digital display (LCD). They can be used for cooling, heating or cooling and heating with automatic changeover. The display and the elegant design make them especially suitable for offices or hotels where a display is required. There are variants for 2-pipe and 4- pipe systems and options for simple ON/OFF, 3-position or analog output signals. The RDX product family with display RDX is a family of microprocessor-based controllers with digital display (LCD). It is designed for 1- or 2-stage heating and 1-stage cooling with fan coil as well as heat pump applications with 1-stage compressors and reversing valve. VAV The RCU/RDU product family (VAV) The RCU/RDU microprocessor-based controllers are designed for VAV room temperature control acting on 0 10 V, 3-position or ON/OFF field devices. RDU room temperature controllers have a digital display (LCD) and their additional functionality extends the variety of applications. Monitoring The RAK/RAZ product family For temperature limitation of heating systems as well as domestic hot water, we recommend RAK-TB and RAK- ST capillary tube thermostats. RAK-ST are similar to RAK- TB but with increased safety functions. RAZ-ST is in each case a combination of RAK-TR and RAK-ST. For the safety limit thermostats (STB), the failsafe function and the compensation of the ambient temperature are special features. The QAF product family The QAF frost protection thermostats can be used for frost protection in air conditioning systems. The QAF family consists of purely electromechanical models with ON/OFF output as well as capillary tube thermostats with electronic measurement and modulating as well as ON/OFF outputs. 9-4

Fields of application and principal functions Compact room temperature controllers Heating only/cooling only RAA.. RCU.. RDU.. RDD.. RDE.. RAA Tamperproof version 10 Setpoint adjuster 20 Setpoint adjuster, ON/OFF switch 30 Setpoint adjuster, ON/OFF switch, mode indications 30.16 / GR Setpoint adjuster, 2 ON/OFF switches, 2 mode indications 30.26 / GR Setpoint adjuster, mode changeover switch for heating or cooling 40 RCU/RDU Heating or cooling and secondary heating sequence ON/OFF/PWM 10 Heating or cooling and secondary heating sequence, mode changeover switch ON/OFF/PWM 10.1 Heating or cooling (3-position) 20 20 RDD LCD and automatic operation mode changeover 10 LCD and automatic operation mode changeover, battery-powered 10.1 9 RDE LCD, 7-day time switch 10 LCD, 7-day time switch, battery-powered 10.1 LCD, 7-day time switch, ext. temperature sensor input, battery-powered 20.1 Heating only/cooling only 24-hour clock Weekday/ 7-day clock 7-day clock 7-day clock week-end clock Application REV100, REV12, REV16 REV23.., REV200, REV33, REV300 REV23M RAV11.1 REV26, RAV11.7 Gas boilers Burner control Electric room heating Cooling fan-coil units Circulating pump control 3-position mixing control ON/OFF zone control Open/closed actuators Floor heating distribution «OpenTherm Plus» boiler Quasi-modulating control (ON/OFF) Modulating control (3-position) Modulating control (communication) See the relevant data sheets for technical data and a brief description 9-5

Fields of application and principal functions Fan-coil systems with RAB../RCC../RDF.. RAB.. RCC.. RDF.. RAB.. 2-pipe External changeover with ventilation 20.1 Heating or cooling without ventilation 20 2-pipe Manual changeover with ventilation 10.1 Heating or cooling without ventilation 10 4-pipe Manual changeover with ventilation 30.1 Heating or cooling without ventilation 30 RCC../RDF.. 2-pipe Manual changeover heating or cooling 10.2 Heating or cooling 10.1 10.1 Heating or cooling with ext. sensor input 10 10 Heating or cooling with electr. heating 20 20 Heating or cooling (0 10 V) 50.1 50.1 Heating or cooling (3-position) 60.1 60.1 4-pipe Heating or cooling 30 30 Heat pump RDX.. RDX Heat pump controller AC 230 V 42.2 Heat pump controller AC 24 V 42.22 VAV and CAV RCU.. RDU.. RCU/RDU One sequence (0 10 V), automatic heat-cool change-over 50 50 One sequence (0 10 V), operating mode selector 50.1 One sequence (0 10 V), operating mode selector 50.2 50.2 2 sequences (0 10 V and ON/OFF / PWM) 60 2 sequences (0 10 V and ON/OFF / PWM), operating mode selector 60.1 2 sequences (0 10 V and 3-position) 61 2 sequences (0 10 V and 3-position), operating mode selector 61.1 See the relevant data sheets for technical data and a brief description 9-6

Fields of application and principal functions Immersion thermostats and strap-on thermostats RAK-T, RAK-S, RAZ-T, RAZ-S Single and double thermostat, 2-position controller with capillary tube sensor, changeover contact. Application Function Data sheet Set Approvals Type reference Temperature control Temperature limitation Frost protection Air conditioning control Heating boilers Domestic hot water heating Heat exchangers Underfloor heating Control thermostat (TR) Thermal reset limit thermostat (TW) Safety limit thermostat (STB) Limit thermostat (TB) Data sheet number SPocket 100 mm for PN10 Strap 330 mm in package Setpoint minimum temperature ( C) Setpoint maximum temperature (C ) Setpoint cutout temperature (C ) Capillary length (mm) CE ENEC DIN3440 ISPESL C-Tick PED RAK-TR.1000B CE1N1186 15 95 700 RAK-TR.1000S CE1N1186 15 95 700 RAK-TR.1210B CE1N1186 15 82 700 RAK-TW.1000B CE1N1187 15 95 700 nr RAK-TW.1000S CE1N1187 15 95 700 nr RAK-TW.1200B CE1N1187 40 120 700 nr RAK-TW.1200S CE1N1187 40 120 700 nr RAK-TW.5000S CE1N1188 5 65 1600 nr nr RAK-TW.5010S CE1N1188-10 50 1600 nr nr RAK-ST.010FP CE1N1189 95 700 RAK-ST.020FP CE1N1189 100 700 RAK-ST.030FP CE1N1189 110 700 RAK-ST.1300P 120.. CE1N1189 130 700 RAK-ST.1310P CE1N1189 90..110 700 RAK-ST.1430S CE1N1189 80..100 1600 RAK-TB.1400S CE1N1190 45..60 700 RAK-TB.1410B CE1N1190 50..70 700 RAK-TB.1420S CE1N1190 65..80 700 RAZ-TW.1000P CE1N1191 15 95 700 RAZ-TW.1200P CE1N1191 40 120 700 RAZ-ST.010FP CE1N1192 15 95 95 700 RAZ-ST.011FP CE1N1192 15 82 95 700 RAZ-ST.020FP CE1N1192 15 95 100 700 RAZ-ST.030FP CE1N1192 15 95 110 700 RAZ-ST.1500P CE1N1192 40 120 120.. 130 700 RAZ-ST.1510P CE1N1192 15 95 90..110 700 9 Current rating changeover contact: TR & TW: 0.1..10(2.5) / 6(2.5) A Current rating changeover contact: TB & STB: 0.1..10(2.5) / 0.5 A Voltage range: AC 24..250 V nr: not required See the relevant data sheets for technical data and a brief description 9-7

Fields of application and most important functions Frost units QAF8.. and QAF6.. 1) Electromechanical frost protection thermostats QAF81.. and electronic frost protection thermostats as well as frost protection sensors QAF6.. with average temperature measurement by a capillary tube filled with gas. Type reference Operating voltage (AC) ON/OFF output Modulating output Automatic reset Manual reset Data sheet number Setpoint setting range ( C) Measuring range ( C) Capillary tube length (mm) Minimum active length (mm) IP protection class QAF81.3 CE1N1284-5...15-5...15 3000 300 IP54 QAF81.6 CE1N1284-5...15-5...15 6000 300 IP54 QAF81.6M CE1N1284-5...15-5...15 6000 300 IP54 QAF63.2 24 V CE1N1821 0 15 2000 250 IP42 QAF63.6 24 V CE1N1821 0 15 6000 250 IP42 QAF64.2 24 V CE1N1283 1 15 0 15 2000 250 IP42 QAF64.6 24 V CE1N1283 1 15 0 15 6000 250 IP42 1) Note that the QAF6.. modulating frost sensor may be used only with certain control valves, i. e. it is not suitable for use with 0 20 V phasecut or AC 230 V actuators. Various thermostats Simple changeover thermostats and various electromechanical single and double thermostats for industrial applications; with adjustable switching differentials. Type reference Room thermostat Double thermostat Adjustable switching differential Adjustable switching interval Changeover thermostat Fire protection thermostat Changeover contact (SPDT) Data sheet number Measuring range ( C) IP protection class TRM2. CE1N1328 5...30 IP30 TKM2 CE1N1291 20...110 IP54 TKM2D CE1N1224-10...35 IP54 TRG2 CE1N1329-5...50 IP54 TRG22 CE1N1329-5...50 IP54 TTM2D CE1N1223-10 80 IP54 TTW2D. CE1N1223 20 150 IP54 RYT182 CE1N1295 19 30 IP54 See the relevant data sheets for technical data and a brief description 9-8