My Weigh Triple Beam Balance User Manual



Similar documents
What is a Mouse-Trap

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

OWNER S MANUAL Table Tennis Table Patent Pending

Chemical Changes. Measuring a Chemical Reaction. Name(s)

Features: Mounting the Optic

Thread Tensions All Machines

The Analytical Balance

Chapter 3, Lesson 4: Density: Sink and Float for Solids

Global Water Instrumentation, Inc.

Tape Extensometer. Copyright 2008 Slope Indicator Company. All Rights Reserved.

HYDRAULIC LIFT TABLE CART 2200-LB.

BUILDINGA 1/10 SCALE FLATBED TRAILER

1 TON FOLDING CRANE CFC1000

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

COMBINATION SLAB & TRIM SAW INSTRUCTIONS 12, 14, & 16 MODELS

PRODUCT GUIDE Vinyl Patio Doors (JPG008)

Date R. Mirshahi. Forces are all around us. Without forces, nothing can move and no work can be done.

If you put the same book on a tilted surface the normal force will be less. The magnitude of the normal force will equal: N = W cos θ

Multi-Pitch Pitching Machine USER MANUAL

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

My Weigh Ultraship Series User Manual

MGB Chrome Bumper Conversion

MASTER CASTER INSTRUCTIONS 10/1/91

Tri-Homo Style Operation and Maintenance Instructions

758 Heavy-duty Ratchet Guy Wire Cutter

Friction and Gravity. Friction. Section 2. The Causes of Friction

PART I THE INCREDIBLE SHRINKING ARM

MIME 3330 Mechanics Laboratory LAB 5: ROTATING BENDING FATIGUE

Determination of a Chemical Formula

Chapter 3 Student Reading

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

Installation Instructions S

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Record Cleaning Machine

Balanced & Unbalanced Forces

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

DryWeight BulkVolume

TESTING WHETHER THE TEMPERATURE OF A MAGNET WILL AFFECT HOW FAR ITS MAGNETIC FIELD IS

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

Written By: Walter Galan

SOLUBILITY OF A SALT IN WATER AT VARIOUS TEMPERATURES LAB

LADDER SAFETY (Reviewed 9/27/207)

Tips from the Drain Cleaning Pro s

2006 JUDY SERVICE GUIDE

Inventory of Parts. American Stirling Company

XPULT INSTRUCTIONS BASIC VERSION

SETUP MANUAL FOR JMW TONEARM 10.5 AND 12.5 VERSION READ THIS MANUAL VERY CAREFULLY NOT FOLLOWING THIS MANUAL WILL VOID YOUR WARRANTY

VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR LABORATORY TESTING

Computer Lane Monitor HOW TO MAKE A TAPE AND HOW TO READ A TAPE

Physics 221 Experiment 5: Magnetic Fields

PENNY IN A CUP: DEMONSTRATING THE LAW OF INERTIA

Mixtures and Pure Substances

not appearance. ADHESIVE SYSTEMS CORIAN As an integral part of its sheet and shape products, DuPont has developed a special adhesive.

S&G Model 2937 Group 1 Combination Lock

Table of Contents WARNING SYMBOLS AND DEFINITIONS

ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST

Service Manual SSCI. The Care and Maintenance of Casters. Wheeling, IL (800) Form No /06

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

Front brakes (FN- 3), servicing

HOME GYM. Model. Retain This Manual for Reference OWNER'S MANUAL.

CALIBRATION FOR LAL20X & LAL24X

INSTRUCTIONS FOR CHAIN LINK INSTALLATION Chain Link fence & Posts Meshdirect.co.uk

FRICTION BRAKE ON A LECLERC LOOM

Installation Instructions

Mini multi-purpose sewing machine

Contents. Front Derailleurs Part One - Planning... 2 I. Objectives... 2 II. Materials Needed... 2 III. Setting...2 IV. Evaluation...

Pre-lab Quiz/PHYS 224 Magnetic Force and Current Balance. Your name Lab section

2-SLICE COOL TOUCH TOASTER

RULE # 1 is DON T mess with things that you don t know anything about! (Take them to a pro & pay them to fix it)


WARNING: Important: Keep these instructions for future reference. Gate Instructions (1) Assembly and Installation Instructions

Solstice/Sky Water Pump Replacement

ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST

How to Conduct a Magnet Pull Test

Repair Section. We need to remove both heat syncs from the motherboard. Heat syncs are shown in the picture below.

How To Change Your Oil and Filter-Suzuki GS by BassCliff (a.k.a. BikeCliff)

Torque and Rotation. Physics

Written By: Walter Galan

Hand Held Centripetal Force Kit

The Enbrel SureClick autoinjector is a single-use prefilled autoinjector. It contains one 50-mg dose of Enbrel.

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

Twist Drill Grinding Attachment By Steven Skiprat Jackson June 2009

Heat Transfer. Condensation. Revaporization

Prelab Exercises: Hooke's Law and the Behavior of Springs

15GAL STEEL OIL DRAIN WITH 110V PUMP

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Drive shaft, servicing

These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts.

Ford F-Series Column Shift Repairs

Adjusting the Powder Burn rate Factor and the Bullet Weight to Help Match QL to Range Chronograph Data:

e I N S T RUC TION M ANU A L

Eighth Grade, Density To Float or Not to Float? 2004 Colorado Unit Writing Project 1

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

The DC Motor. Physics 1051 Laboratory #5 The DC Motor

Just-Like-Mine! Doll or Stuffed Toy. Car Seat. Instruction Manual. These instructions are for the following Joovy Style # s: 002, 003

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Assembly and Usage Instructions

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

Transcription:

My Weigh Triple Beam Balance User Manual

Troubleshooting: Before troubleshooting please take these words of "Balance Beam Wisdom": Balance Beams are a very old and basic design of scale. They date back to the ancient Egyptian Empire and Balance Beam scales were used to build the pyramids. Thus, the design is quite simple - a cup (hidden on modern beam scales) filled with metal loose weights and some metal sliding weights. Therefore to fix a Balance Beam scale requires very basic steps - such as adding/removing weight from the cup or using a wrench to make the beam operate smoothly (if it's touching or rubbing as it operates). First, before troubleshooting be certain that you have correctly unpacked the scale and removed all rubber stoppers (you'd be surprised how many times this happens). Also be sure that the sliding weights are all at their proper ZERO position. Please be 100% sure that you have removed both rubber stoppers and all packing bands/materials. 1) "My Scale Won't Zero": Sometimes in transport the beam will somehow become unbalanced. This means adjusting the zero knob doesn't make the scale zero properly. If this happens to your scale please know that you can manually add or remove weight to the "Balance Cup". The Balance cup is located underneath the round metal tray. Simply spin the tray off (counterclockwise) to access the Balance Cup and add or remove weight as follows: If your scale would not zero because it was reading too light (meaning you would have had to press down on the tray to make it zero), then add a small amount of weight to the cup (just a coin or paperclip, you can add or remove weight as you require). If your scale would not zero because it was reading too heavy (meaning you would have had to pull up on the tray to make it zero), then remove a small amount of weight from the cup (just remove a tiny amount, you can remove or add weight as you require). If you are trying to compensate for a small bowl or tray, you can remove weight from the cup until the scale Zeros. The Balance Beam is a very basic scale and if it Zeros & moves freely, then it always reads accurately. 2) "The Beam is Rubbing / Touching": In order for this scale to work properly, it must operate smoothly without touching or rubbing. Sometimes in transport the beam will get shifted and touch the internal magnets by the front of the beam (where the "0" indicator is). If this happens please try to manually adjust the beam using a wrench on the main bolt under the scale. Simply twist the beam to make it operate smoothly. If you cannot make the beam operate smoothly then the scale will need to be sent in for service. 3) "My Scale won't go back to Zero": A triple beam works with a set of sliding weights. If these weights are not put back EXACTLY to their Zero position, the scale won't return to zero. Be sure that when you Zero the scale you note where you have put all 3 weights exactly, then when you are done weighing be sure they are in the exact same place. Based on the laws of physics it would be impossible for the beam not to return to Zero if the weights are put back to the same spot (unless the beam is rubbing/touching or if the surface you are weighing on is not level). Construction and Application The My Weigh MB-2610 Single-Pan Balance is of unequal arm type with three beams. The beam is made of high quality aluminum alloy and the plane is of agate which can improve accuracy of use and lengthen life of operation. To speed up weight readings, the magnetic damping system brings the pointer to rest with a minimum number of swings. It is widely suitable for physical-chemistry experiments and analytical weighing in chemical works, medical and hygiene, food-stuff, agriculture, textiles, electronics, mines, scientific research institutions, universities and colleges, etc. Unpacking: Carefully remove the balance and the separate poise (sliding weight) from the protective carton. You will find a slit rubber washer lodged underneath the

protective carton. You will find a slit rubber washer lodged underneath the platform, and one rubber washer located above the pointer. The washers are to be removed from the scale. Set-up: After placing the balance on a smooth, flat surface, slide each separate poise (sliding weight) into itʼs zero slot. With all poises at the zero position, the pointer should be near zero. Carrying the Balance: Be sure all riders are back to the zero point. Place one hand under the balance and the other hand on the support (arm) to carry the balance. Zeroing: For exact zero, adjust the knurled knob which is located at the left end of the beam. It is advisable to check the zero adjustment periodically. Weighing Process: Before Weighing: Zero the balance before you determine the weight of any substance. a) Slide all of the riders back to the zero point. b) Check to see that the pointer swings freely along the scale. c) Use the adjustment knob to obtain an equal swing of the beams, if necessary. You do not have to wait for the pointer to stop at the zero point. The beam should swing an equal distance above and below the zero point. You must repeat this procedure to "zero" the balance every time you use it. Begin Weighing: Place the specimen on the center of the platform and proceed as follows: 1. Starting with the largest capacity beam (500 g), move the 500 g poise to the right to the first notch which causes the pointer to drop, then, move it back one notch, causing the pointer to rise. 2. Repeat procedure with the 100 g poise. 3. Slide the 10 g poise to the position that brings the pointer to rest at zero. The weight of the specimen is the sum of the values of all poise positions, read directly from the graduated beams. NOTES: A) Never put a hot object directly on the balance pan. Any dry chemical that is to be massed should be placed on paper or in a container. B) Never pour chemicals directly on the balance pan. Remember to weigh or zero the paper or container before adding the substance. C) Remember; the pointer does not have to stop swinging, but the swing should be an equal distance above and below the zero point on the scale. Attachment weights: Total capacity is either 2610 grams or 5 pounds, 2 ounces when attachment weights are suspended from the pivots. Without the weights, the capacity is

Care and maintenance: Keep the balance clean at all times. Most dirt or foreign matter can easily be removed with an air syringe, but a piece of adhesive-backed tape pressed against the magnet faces will keep them free from dirt. Never apply lubricants to the knives or bearings and donʼt allow dirt or foreign materials to accumulate on any part of the beam. The Beam must be kept clean in order to provide years of accurate stable readings. Specifications Capacity: Without attachment weights: 610g With included attachment weights: 2610g Readability: 0.1g Weighing Units: grams Beam Calibrations: 10 x 0.1g, 100 x 10g, 500 x 100g Features: Three beam direct reading Attachment Weights Included Magnetic Damping System Troubleshooting: Before troubleshooting please take these words of "Balance Beam Wisdom": Balance Beams are a very old and basic design of scale. They date back to the ancient Egyptian Empire and Balance Beam scales were used to build the pyramids. Thus, the design is quite simple - a cup (hidden on modern beam scales) filled with metal loose weights and some metal sliding weights. Therefore to fix a Balance Beam scale requires very basic steps - such as adding/removing weight from the cup or using a wrench to make the beam operate smoothly (if it's touching or rubbing as it operates). First, before troubleshooting be certain that you have correctly unpacked the scale and removed all rubber stoppers (you'd be surprised how many times this happens). Also be sure that the sliding weights are all at their proper ZERO position. Please be 100% sure that you have removed both rubber stoppers and all packing bands/materials. 1) "My Scale Won't Zero": Sometimes in transport the beam will somehow become unbalanced. This means adjusting the zero knob doesn't make the scale zero properly. If this happens to your scale please know that you can manually add or remove weight to the "Balance Cup". The Balance cup is located underneath the round metal tray. Simply spin the tray off (counterclockwise) to access the Balance Cup and add or remove weight as follows If your scale would not zero because it was reading too light (meaning you would have had to press down on the tray to make it zero), then add a small amount of weight to the cup (just a coin or paperclip, you can add or remove weight as you require). If your scale would not zero because it was reading too heavy (meaning you would have had to pull up on the tray to make it zero), then remove a small amount of weight from the cup (just remove a tiny amount, you can remove or add weight as you require). If you are trying to compensate for a small bowl or tray, you can remove weight from the cup until the scale Zeros. The Balance Beam is a very basic scale and if it Zeros & moves freely, then it always reads accurately. 2) "The Beam is Rubbing / Touching": In order for this scale to work properly, it must operate smoothly without

2) "The Beam is Rubbing / Touching": In order for this scale to work properly, it must operate smoothly without touching or rubbing. Sometimes in transport the beam will get shifted and touch the internal magnets by the front of the beam (where the "0" indicator is). If this happens please try to manually adjust the beam using a wrench on the main bolt under the scale. Simply twist the beam to make it operate smoothly. If you cannot make the beam operate smoothly then the scale will need to be sent in for service.