DC Electronic Loads 8500 series



Similar documents
Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series

1.44 kw Programmable DC Power Supplies XLN Series

High Power Programmable DC Power Supplies PVS Series

KONSTANTER SPL / SPL Programmable Electronic Load

SL Series AC and DC Electronic Loads

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Mobile Communications DC Sources W

Voltech DC1000. Precision DC Bias Current Source

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Hand-held thermometer Model CTH7000

FIREDEX Conventional Fire Panels

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

DCS Series 1 kw, 1.2 kw, & 3 kw

Temperature & Humidity SMS Alert Controller

Thyristor-controlled power supplies and battery chargers

Everything you need for protection scheme testing

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

Physical Specifications (Custom design available.)

Wahl C50 Calibrator FEATURES

MIT510/2, MIT520/2 and MIT1020/2

Multi-Function Ground

High Voltage Power Supplies

Quick Connect. quick - simple - efficient.

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

How To Use An Hm804X Series Of Power Supplies

Manual. Solar Fountain Mobile Phone Charger

MIDI control allows the Split Personality to be used remotely in rack systems, or integrated into MIDI controlled setups for easy preset recall.

OZW30. Central Unit SYNERGYR

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Duct Humidity Transmitter

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

Current Monitoring Kit

Agilent E3633A and E3634A DC Power Supplies

Agilent 4338B Milliohm Meter

DAB+ / FM Tuner Model: TU-201

Handheld portable appliance testers

Features, Benefits, and Operation

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

User s Manual. Programmable DC Electronic Load. 372x series

5000V Graphical Megohmmeter Model 5070

Voltage Regulator SPAU 341 C. Product Guide

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

User's Guide. Integrating Sound Level Datalogger. Model Introduction

BB800 Off-Grid Solar System

DPI 260 SERIES: Digital Pressure Indicators

NC-12 Modbus Application

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Frequency selective monitoring and logging of environmental electromagnetic fields

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Repeaters and Mimics Data Sheet

Chapter1 General Introduction Function Features Front Panel Rear Panel Keypad Function Annunciators

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

/ LCR HiTESTER Components measuring instruments

RS - SPM. Serial parallel translator module

Telephone- and leased line modem for industrial applications TD-36

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

BITMAIN. APW PSU Series User Guide

MODEL 62000H-S SERIES

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Notice. Reverse engineering and disassembly are prohibited.

Photovoltaic Solar Energy Unit EESFB

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Disturbance Recoder SPCR 8C27. Product Guide

PowerGem Pro Uninterruptible Power Supply

Electronic Control Devices The European Product Catalogue 2007

1. SAFETY INFORMATION

Analog signal converters CC-E I/I Current / current isolators

T Substation Maintenance and Commissioning Test Equipment

Continuous, remote monitoring and logging of electromagnetic fields

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Low and High Voltage Power Supplies

FREJA 300 Relay Testing System

been built in for recall of the stored settings at any time. For automated testing, the save and recall functions can save a great deal of time.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Rack mounted telephone- and leased line modem for industrial applications

Current Monitoring Kit QUICK START GUIDE

Digital input modules

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

TX OPEN RS232/485 module

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Plena Weekly Timer. Installation and User Instructions PLN-6TMW

MLC TM Maximum Productivity and Versatility for Control without Compromise!

PROGRAMMABLE DC ELECTRONIC LOAD MODEL 6310A SERIES MODEL 6310A SERIES. Programmable DC Electronic Load. Key Features:

Transcription:

Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating a variety of DC power sources. Their wide operating ranges of up to 500 V and 240 A, flexible operating modes and excellent measurement accuracy make the 8500 series well suited for characterizing DC Power supplies, DC-DC Converters, batteries, fuel cells and solar cells. The loads can operate in CC, CV, CR or CP mode while voltage/current or resistance/power values are measured and displayed in real time. Load terminals are isolated and floating. Extensive protection, including over temperature, over power, over voltage, over current and reverse polarity will help protect your valuable prototype. The DC loads are easy to use. All parameters can be set quickly and precisely from the front panel, or programmed via RS232 or USB interfaces. The 8500 family offers 10 models with a wide range of ratings Model# Power Operating Voltage Rated Current 8500 300 W 0.1-120 V 30 A 8502 300 W 0.1-500 V 15 A 8510 600 W 0.1-120 V 120 A 8512 600 W 0.1-500 V 30 A 8514 1200 W 0.1-120 V 240 A 8518 1200 W 0.1-60 V 240 A 8520 2400 W 0.1-120 V 240 A 8522 2400 W 0.1-500 V 120 A 8524 5000 W 0.1-60 V 240 A 8526 5000 W 0.1-500 V 120 A When selecting a DC load, it is important to consider not only voltage and current requirements, but also power ratings. The power used when testing must fall within the hatched region for the appropriate DC load. Some applications may require high voltage/low current and low voltage/high current which a single load may not be able to handle. B&K Precision s broad range of DC loads will allow you to select the optimal model for your requirements. Input voltage Rated power Input current Technical data subject to change B&K Precision Corp. 2013 w w w.bk precision.com Tel.: 714.921.9095

Features Constant current (CC), resistance (CR), voltage (CV) and power (CP) operation Wide voltage and current range, 0 to 500 V, 0 to 240 A (5000 W max) Low minimum operating voltage of < 0.1 V and minimum input resistance of 5 mω (model 8518) allowing the load to sink high current at low voltages, required for fuel and solar cell applications Selected models operate up to 500 V, suitable for high voltage applications Built-in transient generator Short circuit test Built-in high resolution (0.1 ma/1 mv) voltage and current measurement (models 8500 & 8502) Bright, easy to read display (VFD technology) Over-Current/Over-Voltage/Over-Power/Over- Temperature Protection RS232 to TTL, USB to TTL serial converter cables and application software included List mode operation for increased throughput. Battery testing mode to provide A*hr rating of battery (ending voltage level is adjustable) Flexible triggering: Create trigger events by front panel keystroke, back panel TTL signal, or software Remote voltage sensing to compensate for the effect of voltage drop in wires. Store 25 instrument setups Thermostatically-controlled fans allow operation in quiet environments with minimal disruption All models are rack mountable. Compact 300 W and 600 W models for bench use Applications: DC power supply testing Characterization of rechargeable batteries. A battery test mode is provided that will measure the ampere*hour (A*hr) characteristic of a battery Fuel and solar cell test High voltage applications Low voltage operation The 8500 series can operate well below 1 V which is important for low voltage application such as fuel cell and solar cell testing. All models can regulate (provide a stable input) down to 0.1 V. Model 8518, due to its particularly low input resistance, can operate at full scale current of 240 A at 1.2 V (see image) Typical minimum operating voltage at full scale current: 8500 8502 8510 8512 8514 8518 8520 8522 8524 8526 1.05 V 3 V 1.8 V 3 V 1.92 V 1.2 V 10.8 V 3.6 V 1.56 V 1.8 V 2 www.bk precision.com

DC Electronic Loads Front panel 1 2 The numeric keys and rotary knob provide a convenient interface for setting the operating mode and desired current/voltage/resistance levels quickly and precisely. Voltage and current can be set to a maximum resolution of 1 mv and 0.1 ma respectively (models 8500 and 8502 only). Up to 25 different instrument setups can be stored and recalled from internal memory. 1 ) High re solution, easy to read display Displays set values and measured values. Current/voltage and power/resistance displays can be toggled. Display resolution for current and voltage is user-selectable. Maximum resolution for model 8500 and 8502 is 1 mv/ 0.1 ma. 3 4 5 Hex-head sc rew t erminals 2) Convenie nt d ata e ntry Rotary knob for quick analog-style control. Turn to adjust a setting value. Press to toggle measurement display mode. 4) Function keys Activate current, voltage, power, or resistance modes and scroll through menus and options. 3) 5) Front panel load terminals Connect to device under test. Hex-head screw Numer ic keypad Conveniently enter set values directly and access secondary functions. 1 Rear panel 1) Air vents Temperature-controlled fan expels air through these vents to keep the temperature constant inside the system. 3 ) Interface connection Serial interface connector for RS232 or USB communication. 2) 4) Voltage switch Line voltage selection switch (110 VAC or 220 VAC). Trigge r and remote sensing terminal block Connect sensing lines to this terminal to compensate for voltage drops due to load wire resistance. This terminal block also contains the two connections for the remote TTL trigger input signal. terminals are used for models 8518 and 8520 8526 to connect wires. 3 3 2 4 w w w.bk prec ision.c om

Flexible operating modes CC, CR, CV and CP mode In Constant Current (CC) mode, the load will sink a current according to the programmed current value regardless of the input voltage. (CC) mode can be used for load regulation testing of DC power supplies or for characterizing the discharge profile of a battery. Constant Power (CP) mode simulates a load whose power consumption is independent of the applied voltage. Constant Power (CP) mode is useful for battery testing and simulating a realistic discharge curve. In Constant Voltage (CV) mode, the load will attempt to sink enough current to control the source voltage to the programmed value. This mode is suitable for testing battery chargers. In Constant Resistance (CR) mode, the load will sink a current linearly proportional to the input voltage in accordance with the programmed resistance. Unlike conventional resistors, the load resistance stays constant regardless of the power level. Transient generator The 8500 series offers a variable frequency generator which can be used in all operating modes. The DC load will toggle between 2 preset levels at a frequency between 0.1 Hz to 1 khz, either continuously or controlled by a trigger. Triggered operation Triggering is used to allow synchronization of the DC Load's behavior with other events. You can generate a trigger event by front panel keystroke, by applying an external TTL signal to the back panel terminal or by sending a commands over the serial bus. The trigger can be used in pulse mode, transient mode, list mode and works in CC, CR, CV and CP modes. Model 8500 Remote control & application software The DC loads can be remotely controlled from any PC with USB or RS232 interface, allowing the user to fully program and monitor all parameters. RS232 to TTL and USB to TTL serial converter cables are included. For users wanting to write their own custom software, a set of example programs are available for download on the B&K Precision website. List Mode A list of command sequences can be stored in non-volatile memory and executed independently of a computer. Execution in list mode greatly reduces command processing time and computer interaction during product testing. The command sequence can be entered manually from the front panel or downloaded from a PC via RS232 or USB interface. Application Software The included Application Software supports front panel emulation of the load and includes a battery test application which provides A*hr rating of a battery and adjustable ending voltage levels (safety voltage). An example of battery discharge characteristics of an AA alkaline battery. Whether you are designing a device with Nickel-Metal Hydride or Lithium-Ion batteries, the 8500 series have the capabilities to test their characteristics. 4 www.bk precision.com

Specifications Models 8500 & 8502 (300 W) Parameter 8500 8502 Voltage 0 to 120 V 0 to 500 V Input rating Current 1 ma to 30 A 1 ma to 15 A Power 300 W 8500 8502 CV Mode 0.1-18 V ±(0.05%+0.02% FS) 1 mv Regulation 0.1 120 V 0.1 500 V ±(0.05%+0.025% FS) 10 mv CC Mode 0 3 A 0 3 A ±(0.1%+0.1% FS) 0.1 ma Regulation 0 30 A 0 15 A ±(0.2%+0.15% FS) 1 ma 0 3 A 0 3 A ±(0.1% + 0.1% FS) 0.1 ma Current Measurement 0 30 A 0 15 A 8500: ±(0.2%+0.15% FS) 8502: ±(0.2%+0.3% FS) 1 ma Voltage Measurement 0-18 V ±(0.02% + 0.02% FS) 1 mv 0-120 V 0 500 V ±(0.02% + 0.025% FS) 10 mv Models 8510/8512/8514/8518 (600 W & 1200 W) Parameter 8510 8512 8514 8518 Input rating Voltage 0 120 V 0 500 V 0 120 V 0 60 V Current 0 120 A 0 30 A 0 240 A 0 240 A Power 600 W 1200 W 8510 8512 8514 8518 CV Mode 0.1-18 V ±(0.05%+0.02% FS) 1 mv Regulation 0.1 V to Vmax ±(0.05%+0.025% FS) 10 mv CC Mode 0-12 A 0-3 A 0-24 A ±(0.1%+0.1% FS) 1 ma Regulation 0 max Current ±(0.2%+0.15% FS) 10 ma Current Measurement 0-12 A 0-3 A 0-24 A ±(0.1% + 0.1% FS) 1 ma 0 max. Current ±(0.2%+0.15% FS) 10 ma Voltage Measurement 0 18 V 8510/8514: (0.02% + 0.025% FS) 1 mv 8512/8518: (0.02% + 0.02% FS) 0 - Vmax ±(0.02% + 0.025% FS) 10 mv Models 8520/8522/8524/8526 (2400 W & 5000 W) Parameter 8520 8522 8524 8526 Input rating Voltage 0 120 V 0 500 V 0 60 V 0 500 V Current 0 240 A 0 120 A 0 240 A 0 120 A Power 2400 W 5000 W 8520 8522 8524 8526 CV Mode 0.1-18 V ±(0.05%+0.02% FS) 1 mv Regulation 0.1 V to Vmax ±(0.05%+0.025% FS) 10 mv CC Mode 0-24 A 0-12 A 0-24 A 0-12 A ±(0.1%+0.1% FS) 1 ma Regulation 0 max Current ±(0.2%+0.15% FS) 10 ma Current Measurement 0-12 A 0-3 A 0-24 A 0-12 A ±(0.1% + 0.1% FS) 1 ma 0 max. Current ±(0.2%+0.15% FS) 10 ma 0 18 V 8522/8526: (0.02% + 0.02% FS) 1 mv Voltage Measurement 8520/8524: (0.02% + 0.025% FS) 0 - Vmax ±(0.02% + 0.025%FS) 10 mv 5 www.bk precision.com

Common characteristics CR Mode Regulation (Input current FS 10% Input voltage FS 10%) CW Mode Regulation (Input current FS 10% Input voltage FS 10%) Power Measurement (Input current FS 10% Input voltage FS 10%) 0.1-10 Ω ±(1%+0.3% FS) 0.001 Ω 10-99 Ω ±(1%+0.3% FS) 0.01 Ω 100-999 Ω ±(1%+0.3% FS) 0. 1 Ω 1K-4 KΩ ±(1%+0.8% FS) 1 Ω 0-100 W ±(1%+0.1% FS) 1 mw 100 W - max power ±(1%+0.1% FS) 100 mw 0-100 W ±(1%+0.1% FS) 1 mw 100 W - max power ±(1%+0.1% FS) 100 mw Other Battery testing function Input = 0.1 V 120 V, Max measurement capacity = 999 Ah Resolution = 10 ma, Timer range = 1-60000 sec Transition mode Range of Frequency 0.1 Hz-1 khz, Frequency error rate 0.5% Power input Operating temperature Storage temperature Humidity Safety Electromagnetic compatibility 110 / 220 (see note below)* VAC ± 10%, 47 63 Hz 32 ºF - 104 ºF (0-40 ºC) 50 ºF - 140 ºF (10-60 ºC) 95% relative humidity, non-condensing EN61010-1:2001, EU Low Voltage Directive 73/23/EEC amended by 93/68/EEC Meets EMC Directive 89/336/EEC amended by 93/68/EEC, EN50081-1, EN50082-1 One-Year Warranty * All 8500 series models, with the exception of models 8524 and 8526, can be configured for 110 V or 220 V operation via the AC line switch in the rear panel. Base models 8524 and 8526 operate with 110 V only. For 220 V operation, order model 8524-220V or 8526-220V respectively. -220V denotes 220 V operation only and these models cannot be reconfigured for 110 V operation. Mechanical specifications Model Dimensions (W x H x D) Weight 8500 8.46 x 3.46 x 14 (215 mm x 88 mm x 355 mm) 11.5 lb (5.2 kg) 8502 8.46 x 3.46 x 14 (215 mm x 88 mm x 355 mm) 11.5 lb (5.2 kg) 8510 16.9 x 3.46 x 14 (429 mm x 88 mm x 355 mm) 31 lb (14 kg) 8512 16.9 x 3.46 x 14 (429 mm x 88 mm x 355 mm) 31 lb (14 kg) 8514 16.9 x 3.46 x 14 (429 mm x 88 mm x 355 mm) 31 lb (14 kg) 8518 16.9 x 3.46 x 14 (429 mm x 88 mm x 355 mm) 31 lb (14 kg) 8520 17.48 x 7.09 x 21.22 (444 mm x 180 mm x 539 mm) 66 lb (30 kg) 8522 17.48 x 7.09 x 21.22 (444 mm x 180 mm x 539 mm) 66 lb (30 kg) 8524 17.48 x 14.06 x 21.22 (444 mm x 357 mm x 539 mm) 148 lb (67 kg) 8526 17.48 x 14.06 x 21.22 (444 mm x 357 mm x 539 mm) 148 lb (67 kg) Accessories Standard Optional Power cord, user manual, installation CD with application software, RS232 to TTL serial converter cable IT-E131, USB to TTL serial converter cable IT-E132 Rack mount kit IT-E151 for models 8500, 8502, 8510, 8512, 8514 and 8518 only 6 v061813 www.bk precision.com