MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Power Supplies 3. SDN-P DIN Rail Series

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

TEP 200WIR Series, Watt

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

STRATO LED Drivers 70W, Single output

650W Single Output Power Supply

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Watts SHP Series

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

ST Series POWER SUPPLIES USER INSTRUCTIONS

Telephone- and leased line modem for industrial applications TD-36

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

APD / Outputs 19" DC/DC Converter, 50 Watt

Redundancy Module QUINT-DIODE/40

is then retained absolutely without interruption.

I STAR COMPUTER CO., LTD

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Single Output Switching Power Supply

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Operating Manual UWAPS-TINY Series

Rack mounted telephone- and leased line modem for industrial applications

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relay CM-PFE

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Analog signal converters CC-E I/I Current / current isolators

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

7.5 Watt AC-DC Switch Power Supply

Maximum Input Current Vin=18V, 100% Load A

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Series AMLDL-Z Up to 1000mA LED Driver

Thermistor motor protection

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

User s Manual Before using the inverter, you need to read and save the safety instructions.

Safety technique. Emergency stop module BO 5988 safemaster

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Application Note TMA Series

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Antec TruePower User's Manual

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A Vin=24V ma

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

UMEC International Corporation

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

User manual Rev. 1.2 (17/04/2015)

PHOENIX CONTACT - 01/2007

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Actuator-Sensor-Interface

EGSTON Standard E2xFxWx 12W

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

7 - Phaseo power supplies and transformers

R-78xx-0.5 INNOLINE. Features. 0.5 AMP SIP3 Single Output. Derating-Graph (Ambient Temperature) DC/DC-Converter

RM4TG20 three-phase network control relay RM4-T - range V

AC-DC Single Output Power Module

Datasheet. Arrant-Light Oy. 120W DR Series

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Emergency lighting units EM powerled

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

3500/62 Process Variable Monitor

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

1756 ControlLogix Power Supplies Specifications

Transcription:

TSP-Series Innovative and Powerful Features! Rugged metal case for harsh industrial environments Shock and vibration proof Worlwide Safety approval package. ATEX certification tested in accordance to IECEX (opt. EX) Model TSP 090-124N meets NEC class 2 Industrial operating temperature range: 25 C to +70 C Adjustable output voltage Protection against short-circuit, overvoltage and over-temperature Power OK signal, Remote On/Off Wall mounting (opt.) 3-year product warranty Function Modules (see page 5) EMC LVD CB Scheme IEC 60950-1 UL 60950-1 UL 508 UL 60079-15 ATEX II3G The TSP series comprises high performance DIN-rail mount power supplies designed for reliable operation under difficult factory floor conditions. High immunity against electrical disturbances and rugged metal casing make these modules the best choice to power sensitive loads in industrial process control systems, machine tools or other demanding industrial applications. They provide a DC-OK signal and external shut down function. Detachable screw terminal blocks make the connection easy. This power supply line is accompanied by a wide range of function modules for reliable system solutions: Models Redundancy modules for true current sharing in parallel operation and for redundant systems. Battery controller modules to configure high reliable UPS systems for 12, 24 and 48 VDC. Selection of battery packs available. Buffer modules for protection against short time AC power loss. Maintenance free! No batteries required. Order Code Output Power (Pmax) **Output Voltage (Vnom) ***Output Current (Imax) TSP 070 112* 72 W 12 VDC 6.0 A TSP 090 124* 90 W 24 VDC 3.75 A TSP 090 124N 90 W 24 VDC 3.75 A TSP 090 148* 96 W 48 VDC 2.0 A TSP 140 112* 144 W 12 VDC 12.0 A TSP 180 124* 180 W 24 VDC 7.5 A TSP 180 148* 192 W 48 VDC 4.0 A TSP 360 124* 24 VDC 15.0 A TSP 360 148* 360 W 48 VDC 7.5 A TSP 600 124* 24 VDC A TSP 600 136 600 W 36 VDC 16.5 A TSP 600 148* 48 VDC 12.5 A * For ATEX compliant models add appendix -EX to order code. ** Output voltage adjustable 12 14 VDC, 24 28 VDC and 48 56VDC *** Max. current at nominal output voltage and operating temperature up to +40 C max. http://www.tracopower.com Page 1 of 9

Input Specifications Input voltage range Input voltage frequency Harmonic limits Holdup time Industrial Power Supplies TSP 070/090 85 264 VAC universal input other models: 85 132 / 187 264 VAC autoselect output current derating at operation below 100 VAC see graph B, page 4 47 63 Hz EN 61000-3-2, Class A (for limited output power) 230 VAC 20 ms 115 VAC 10 ms at full load, 20 ms at 66% load Inrush current 115 VAC 230 VAC TSP 070/090 < 12 A < 20 A TSP 140/180 < 13 A < 25 A TSP 360 < 16 A < 25 A TSP 600 < 25 A < 30 A Recommended circuit breaker, TSP 070/090/140/180 6.0 16.0 A characteristic B TSP 360 10.0 16.0 A TSP 600 16.0 A Efficiency Output Specifications Output voltage adj. range 87 % typ. Regulation Input variation 0.5 % max. Load variation (10 100 %) 0.5 % max. Ripple and Noise (20MHz bandwidth) Electronic short circuit protection Output overvoltage protection Overload protection Overtemperature protection Power back immunity Status indicator 12 VDC models: 12 14 VDC 24 VDC models: 24 28 VDC 36 VDC model: 36 42 VDC 48 VDC models: 48 56 VDC At output voltage higher than nominal output voltage max. output current has to be reduced accordingly, in order not to exceed max. output power. 12 VDC models: 20 V 24 VDC models: 35 V 36 VDC model: 43 V 48 VDC models: 60 V 12 VDC models: 16 V 24 VDC models: 35 V 36 VDC model: 48 V 48 VDC models: 63 V 100 mv pk-pk typ. (200 mv pk-pk max. at Imax) current limitation at Imax. constant current, automatic recovery electronic overload protection switch off at overtemperature, automatic restart dual color LED (green: DC ok, red: DC off) Power OK signal trigger threshold: 12 VDC models: 9 11 V 24 VDC models: 18 22 V 36 VDC model: 27 34 V 48 VDC models: 36 46 V active output signal: 12 VDC models: 11.0 V ±1.0 V (reference to Vout) (20 ma max. for TSP 070, 40 ma max. for TSP 140) 24 VDC models: 22.0 V ±2.0V / 20 ma max. (10 ma max. for TSP 090, 20mA max. for others) 36 VDC model: 34.0 V ±2.0 V / 20 ma max. 48 VDC models: 44.0 V ±4.0 V / 15 ma max. relay output DC OK = contact closed rated: 30 VDC/1.0 A for 12/24 VDC models rated: 30 VDC/2.0 A for 36 VDC model rated: 48 VDC/0.5 A for 48 VDC models http://www.tracopower.com Page 2 of 9

General Specifications Max. capacitive load Industrial Power Supplies unlimited Temperature range Operating 25 C to +70 C max. (for derating see graph A on page 4) Storage 25 C to +85 C Cooling Humidity (non condensing) Pollution degree 2 Temperature coefficient convection cooling, no internal fan 95 % rel. H max. 0.02 %/K Reliability, calculated MTBF (at +25 C acc. to IEC 61709) TSP 070/090 >1.8 Mio h TSP 140 >1.2 Mio h TSP 180/360/600 >0.9 Mio h Remote On/Off by ext. contact. DC on: -S contact open DC off: -S connectetd via 1Kohm to -Vout Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Safety standards Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA-C22.2 No. 60950-1-03 Industrial control equipment UL 508, CSA-C22.2 No. 107 Electrical equipment for machines EN 60204 Electronic equipment for power installation EN 50178 Safety transformers for SMPS EN 61558-2-16 Limited power source (model TSP 090-124N) EN 60950 sect. 2.5 and NEC Class 2 Control equipment for hazardous location UL 60079-15 (Class I, Division 2, Groups A,B,C,D AEx n C II C T4 U) IEC/EN 60079-15 (Class I, Zone 2, EEx nc II C T4 U), ( II3G EEX nac IIC T4 (T3 with limited power) Safety approvals and CB report for IEC/EN 60950-1 certifications www.tracopower.com/products/tsp-cb.pdf UL approvals UL 60950-1 rec. File: e181381, UL 508C listed File: e210002 www.ul.com -> certifications CSA certification (file no. 219759) for UL 60950-1, UL 508, UL 60079-15-02, ANSI/ISA 12.12.01, CSA-22.2 No. 60950-1-03, CSA C22.2 No. 107, CSA 60079-15-02 www.tracopower.com/products/tsp-csa.pdf II3G ATEX 94/9/EC certificate no. EPS 12 ATEX 1 424 X (option -EX only) www.tracopower.com/products/tsp-atex.pdf BG certification EN 60950-1, EN 60204-1, EN 61558-2-16, EN 50178 www.tracopower.com/products/tsp-bg.pdf Class of protection safety class I (IEC 536) Degree of protection IP 20 (IEC/EN 60529) Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 Conducted RI suppression on input EN 55011 class B, EN 55022 class B, Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 Electrostatic discharge (ESD) IEC / EN 61000-4-2 4 kv / 8 kv criteria B Radiated RF field immunity TSP 070/140/360 models: IEC / EN 61000-4-3 10 V / m criteria A TSP 090/180/600 models: IEC / EN 61000-4-3 10 V / m criteria B Electrical fast transient / burst immunity IEC / EN 61000-4-4 2 kv criteria B Surge immunity IEC / EN 61000-4-5 1 kv / 2 kv criteria B Immunity to conducted RF disturbances IEC / EN 61000-4-6 10 V criteria A Power frequency field immunity IEC / EN 61000-4-8 30 A / m criteria A Mains voltage dips and interruptions IEC / EN 61000-4-11 criteria B/C Voltage sag immunity SEMI F47 www.tracopower.com/products/tsp_semif47.pdf http://www.tracopower.com Page 3 of 9

General Specifications Industrial Power Supplies Environment Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10 55 Hz, 1 g, 1 oct/min Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms Enclosure material aluminium (chassis) / stainless steel (cover) Mounting DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) Wall mounting (option) with wall mounting bracket - see page 9 Connection Remote On/Off connection 2 pin molex male terminal KK series Installation instructions detachable screw terminals (plugs included) 2 terminals per output mating connector information (cable not included) www.tracopower.com/products/tsp-rc-cable.pdf www.tracopower.com/products/tsp-inst.pdf Output Power Derating A) Output Power Derating vs Ambient Temperature B) Output Power Derating vs Input Voltage 100 100 90 90 Output Power [% Pmax] 80 70 60 50 40-25 TSP 600 TSP 090 TSP 180 TSP 360 TSP 070 TSP 140 40 50 60 70 Temperature [ C] Output Power [% Pmax] 80 70 60 50 40 85 90 100 110 115 132 187 230 264 Input Voltage [VAC] All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 4 of 9

Function Modules Overview Redundancy Module: With this module and two power supplies of the TSP series a highly reliable, true redundant power system can be configured without any additional components. This module provides: Operation with true current sharing Alarm outputs and redundancy OK signal Hot swappable inputs can be loaded up to 15 A each (resp. 25 A with model TSP REM600) Models Order Code Output Voltage adj. Output Power TSP REM360 24 VDC 360 W TSP REM600 (24 27 VDC) 600 W TSP-REM360 TSP-REM600 TSP-REM datasheet: www.tracopower.com/products/tsp-rem.pdf Battery Controller Modules + Batteries: This module provides a professional battery controller to charge and monitor an external lead-acid battery. Together with a power supply of the TSP series and a battery pack a perfect DC-UPS system can be configured. This module provides: - Battery protection for over voltage, deep discharge, short circuit and reverse connection - Remote On/Off for battery and power supply - Alarm outputs for input, output and battery condition - Controlled end of charge voltage by temperature sensor - Redundant inputs for two indepedant sources (TSP-BCMU360 only) Models Order Code Output Voltage Output Power TSP-BCM12 12 VDC 180 W TSP BCM24 360 W 24 VDC TSP-BCM24A 600 W TSP BCM48 360 W 48 VDC TSP-BCM48A 600 W TSP-BCMU360 24/48 VDC 360 W TSP-BCM24A TSP-BCM48A TSP-BCM12 TSP-BCM24 TSP-BCM48 TSP-BCMU360 TSP-BCM datasheet: www.tracopower.com/products/tsp-bcm.pdf TSP-BCMU datasheet: www.tracopower.com/products/tsp-bcmu.pdf Buffer Module: This module will maintain the output voltage of a 24 VDC power supply during typical mains faults, short time blackouts or voltage dips of up to ten full 50 Hz cycles. During this buffer period no deterioration of the 24 VDC output voltage will occur. This module provides: - Capacitor bank for energy storage, no battery needed! - Maintenance free, long lifetime, high performance also at low temperature. - Guaranteed Hold-up-time 200 ms/25 A to 4 s/1.2 A max. - Output 24 to 28 VDC, 600 W max. - Active ready and inhibit signals Models Order Code Output Voltage Output Power TSP BFM24 24 28VDC 600 W TSP-BFM24 TSP-BFM datasheet: www.tracopower.com/products/tsp-bfm.pdf http://www.tracopower.com Page 5 of 9

Outline Dimensions Models: 35.0 (1.38) 110.0 (4.33) TSP 070/090 DC OK 38.5 (1.52) DC ON O/P ADJ. 110.0 80.0 (3.15) (4.33) PE N L 5.0 (0.20) 5.0 (0.20) P/S P S Remote 54.0 (2.13) 110.0 (4.33) (4.33) S P Weight: 0.5kg (1.0lb) Models: TSP 140/180 DC ON O/P ADJ. DC OK 38.5 (1.52) 110.0 PE N L 80.0 (3.15) 5.0 (0.20) 14.5 (0.57) Remote P/S Weight: 0.7kg (1.4lb) Dimensions in [mm], () = inch Tolerances: ±0.5 mm (±0.02) http://www.tracopower.com Page 6 of 9

Outline Dimensions Models: TSP 360 80.0 (3.15) 1 (4.92) DC ON DC OK 45.0 (1.77) O/P ADJ. 1 86.5 (3.41) (4.92) PE N L 5.0 (0.20) 46.0 17.0 (1.81) (0.67) Remote P S P/S Weight: 1.1kg (2.4lb) Dimensions in [mm], () = inch Tolerances: ±0.5 mm (±0.02) http://www.tracopower.com Page 7 of 9

Outline Dimensions Models: TSP 600 P/S Remote P S 123.0 (4.84) 21.0 (0.83) 165.0 (6.50) 1 (4.92) 45.0 (1.77) (4.92) 1 DC ON 86.5 (3.41) PE N L DC OK O/P ADJ. Weight: 2.8kg (6.0lb) Dimensions in [mm], () = inch Tolerances: ±0.5 mm (±0.02) http://www.tracopower.com Page 8 of 9

Outline TSP WMK Dimensions Wall Mounting mm (inches) Bracket Ordercode of Kit For Models Content of Kit TSP-WMK03 TSP 070, TSP 090, TSP 140, TSP 180 1 bracket TSP-WMK02 TSP 360, TSP 600 2 brackets Industrial Power Supplies TSP-WMK03 42.5 (1.67) 85.0 (3.35) 34.5 (1.36) 34.5 (1.36) ø 4.25 (0.17) ø 4.25 (0.17) ø 4.25 (0.17) R 2.12 (0.083) 4 x positioning holes 2.0 (0.08) R 2.12 (0.083) R 2.12 (0.083) R 2.12 (0.083) 2.0 (0.08) 2.0 (0.08) 2.0 (0.08) 37.0 (1.45) 74.0 (2.91) TSP 070 TSP 090 TSP 140 TSP 180 55.0 (2.16) 15.0 (0.59) 7.0 (0.28) 15.0 (0.59) Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) 33.0 (1.30) 46.0 (1.81) 25 TSP 360 96.0 (3.78) 2.0 (0.08) TSP-WMK02 30.0 (1.18) 2x ø4.3 (0.17) ø 4.3 (0.17) 50.0 (1.97) 62.5 (2.46) 2.0 (0.08) 4 x positioning holes TSP 600 173.0 (6.81) 15.0 (0.59) 7.0 (0.28) Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) 62.5 (2.46) Dimensions: [mm] ( ) = Inch Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com Rev.March 31. 2016 www.tracopower.com Page 9 of 9