2178-S Fiber Optic Splice Case



Similar documents
3M Fiber Optic Splice Closure 2178-LS Series with Gasket

Instructions Fiber Optic Splice Case

COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x mm)

2178-S Fiber Optic Splice Case and Accessories

Expanding a 40-Type Cabinet

Cable Preparation and Pulling Procedure Best Practices for Fiber Optic Indoor Tight-Buffered Cable

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

4 Small Cables Sealing Kit: Wrap Style

XL PREMIUM OIL COOLER KIT

SC, FC and ST * Hot Melt Fiber Optic Connectors

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

3M Scotchcast Mine and Portable Cable Splice Kit

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

Fiber Optic Splice Closure. 1.0 General Product Information. FOSC 600-abc-dd-e-fgh

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

with installation dynafact boost GAUGE this manual is for use with systems

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

M-2004-MBA Brake Duct Kit 2013 BOSS 302, Mustang GT and California Special INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. APPLICATION LENGTH MODEL YR PART # Bestop PART #

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

INSTALLATION INSTRUCTIONS PART NUMBER:

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

Step 1. Item 6. Item 1

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

1 FOSC cover 1 piece Protecting fiber cable splices in whole 2 FOSC bottom 1 piece Fixing reinforced core, fiber cable

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

NOTE WARNING. Electric Leveling Motor Brake Replacement Instructions ELECTRIC LEVELING MOTOR BRAKE REPLACEMENT INSTRUCTIONS. Content.

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

TECHNICAL GUIDE. For Self-Shielded Guns - 300, 400 and 500 amp SAFETY AND WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA OPTIONS

INSTALLATION INSTRUCTIONS

DYNA RIDER FOOTBOARD KIT

5800 Temperature Sensor Cable Assembly

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

Post Mount Light Installation*

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

MARK-3 DIS Digital Ignition Solution

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Katana Supercharger Installation Instructions Rev. E Page 1 of 23

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Section 2 COYOTE Splice Case Series

CHROME FRONT BRAKE MASTER CYLINDER KIT

Installation Instructions Hustler 6-BTV Trap Vertical

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

ATS Overhead Table Shelf System INSTRUCTION MANUAL

GENUINE PARTS INSTALLATION INSTRUCTIONS

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

STEERING SYSTEM - POWER

Installation and Operation Manual

INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV General. Removal (Left and Right Forks) Kit Number

AM/FM ANTENNA RELOCATION KIT

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

R O A D M A S T E R, I N C.

R O A D M A S T E R, I N C.

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Installation Instructions HighRock 4x4 TM

R O A D M A S T E R, I N C.

Scotchlok Connectors and Tools

Installation Instructions

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

INSTALLATION MANUAL. Installation Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Type K current limiting fuse canister Technical information and installation guide

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

DO NOT attempt to repair hub and wheel bearing assembly.

Installation Instructions

R O A D M A S T E R, I N C.

Installation Instructions

Retractable Screen. Replacement Screen Instructions

Speed-Mat Rectangle Cutter

INSTALLATION INSTRUCTIONS P-TRAP SUPPLY KIT Model: RH-3016 These instructions are a guideline for a basic installation

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B

Fluid Regulator. Instructions Parts List L LOW PRESSURE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

2003 ACCORD - Automatic Transmission Removal

758 Heavy-duty Ratchet Guy Wire Cutter

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Self Purging Liquid Trap (SPLT ) User s Manual

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions

CamSplice Assembly Manual

MKV Golf GTI Rear Brake Service - Replace Pads and Rotors

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

RayClic Connection System Installation Instructions

TOYOTA TUNDRA 2015 Billet Grille w/led DRL

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

Transcription:

2178-S Fiber Optic Splice Case Instructions March 1998 34-7041-6288-1-B 1

2

Table of Contents 3M 2178-S Splice Case Description... 4 1.0 General...4 2.0 Specifications...4 3.0 Kit Contents...5 3M 2178-S Splice Case Instructions... 6 4.0 Cable Preparation...6 5.0 Cable Installation...7 6.0 Buffer Tube Preparation...10 7.0 Splice Case Assembly...11 8.0 Splice Case Reentry...12 3

3M 2178-S Fiber Optic Splice Case Description 1.0 General 1.1 The 3M 2178-S Fiber Optic Splice Case is a closure that can be used in buried, underground, aerial, and pedestal applications. The closure is suitable for short term pressurization during flash testing. Please refer to your company's approved applications. The splice case has two cable entrance ports on each end. Port plugs allow the case to be used for butt or inline splices. The rigid non-encapsulated case provides moisture protection. 1.2 The 3M 2180 Cable Kit is used when the 2178-S Fiber Optic Spice Case is reentered. All materials necessary for cable addition and splice case reassembly are provided. A mastic sealed version and a gasket sealed version of this case exist, and the instructions are not the same. Please ensure you follow the correct procedure. 2.0 Specifications Maximum cable diameter:...1.0" (25 mm) Minimum cable diameter:...0.4" (10 mm) Closure length:...21.9" (55.7 cm) Closure width:...8.5" (21.5 cm) Closure height:...4.7" (11.9 cm) Available splice chamber space: length:...16.4" (41.6 cm) width:...5.5" (14 cm) height:...1.2" (3 cm) 2.1 Splice Tray Capacity: The closure will accommodate up to four 1.0" (25 mm) diameter cables inline when using two 3M 2522 trays. When using two 3M 2523 or 3M 2524 trays it is limited to four.5" (12.5 mm) diameter cables inline. Butt applications will accommodate up to 1.0" (25 mm) diameter cables. Number of cables installed...2-4 Maximum number of 2524 Splice Trays*...2 Maximum number of 2523 Splice Trays*...2 Maximum number of 2522 Splice Trays*...2 *Maximum cable diameter equal.50" (12.5 mm) Capacity of 2524 Splice Tray...24-3M Fibrlok Splices...24 - Fusion Splices Capacity of 2523 Splice Tray... 24 - Fibrlok Splices... 12-12 fiber 3M Fibrlok Multi-Fiber Splices*... 24 - Discrete Fusion Splices (single stacked)... 48 - Discrete Fusion Splices (double stacked)... 12-12 fiber Fusion Splices Capacity of 2522 Splice Tray... 12 - Fibrlok Splices... 8-12 fiber 3M Fibrlok Multi-Fiber Splices*... 12 - Discrete Fusion Splices (single stacked)... 24 - Discrete Fusion Splices (double stacked)... 10-12 fiber Fusion Splices *Varies with ribbon size 4

3.0 Kit Contents 3.1 3M 2178-S Kit Contents: Mechanical Splice Case Hose Clamps (3) Sealing Cord Sealing Tape Sealing Washer Tree (6) Cable Ties Green & Blue (4 ea.) Plug (2) 2172 Strength Member Clamps (3) Not shown Sheath scuff, three 3M 2172 strength member clamp boots, two cable tie down brackets, and set screw kit. 3.2 3M 2180 Kit Contents: Hose Clamps (2) Plugs (2) Sealing Cord Sealing Tape Cable Ties Green & Blue (4 ea.) Hex Key Sealing Washer Tree (8) 3.3 Additional Materials Required: 3.4 Tools Required: Cable Cleaner #6 AWG Ground Wire or equivalent Splice Tray / Organizer 3M Scotchlok 4460 D/FO Shield Bond Connector, if using shielded cables 3/8" (10 mm) Hex Driver 1/2" (13 mm) Hex Driver 7/16" (12 mm) Hex Driver Side Cutting Pliers Needle Nose Pliers Cable Stripper Cable Splicer Knife Tape Measure Wire Cutter for Steel Strength Members Electrician's Scissors 5

3M 2178-S Fiber Optic Splice Case Instructions Note 1: If wall mount bracket is required, use the 3M 2198 Mounting Bracket Kit. Attach brackets to base (as shown below) prior to cable preparation. Note 2: Torque bolts to 25 in. lbs. (2.8 N-m) ± 5 in. lbs. (0.6 N-m). Note 3: Proper sealing of the 2178-S Splice Case depends on strict adherence to these instructions and the use of specified sealing materials. Deviations can cause leakage or case damage. Maintain clean and grease free sealing surfaces to ensure proper sealing. DO NOT USE any release agents or other unspecified materials. These types of materials may lead to loss of sealing effectiveness. 4.0 Cable Preparation When removing cable sheathing, do not cut, kink, or damage underlying layers. If damage occurs, cut back sheath component to adequately inspect and repair. 4.1 Remove 96" (244 cm) of outer cable sheath (and shield or armor, if present). Remove successive sheath layers and wrapping to expose primary tubes protecting fibers. Stagger layers as recommended by cable manufacturer or per standard practice. 4.2 Remove all cable grease. Clean all primary tubes and dielectric strands with approved cleaner. Cover all sharp edges with vinyl tape. Carefully follow health, safety and environmental instructions as given on Material Safety Data Sheet or container label for cable cleaner solvent being used. 4.3 Trim any solid filler tubes and discard. Do not trim strength members at this time. 4.4 Scuff 5" (127 mm) of each cable end using supplied sheath scuff. Do not use a carding brush to scuff sheaths. 6

5.0 Cable Installation 5.1 Slide two sealing washers down each cable. Use sealing washers with smallest inside diameter which will slide on cable. If necessary, sealing washers can be split and placed on the cable. 5.2 Locate cables in appropriate entrance ports, as shown. C.O. Field C.O Field C.O Field Field 5.3 Bonding and grounding for shielded cable. Use care when installing shield bond connectors so underlying layers of cable are not damaged. a. Install 3M Scotchlok 4460-D/FO Shield Bond Connector, following instructions provided with connector. If necessary to insure proper fit, remove excess coating on central strength member. b. If separate external grounding is required, bond "C.O. Cable" and "Field Cable" directly to separate ground studs. Torque ground stud nut to 35 in. lbs. (4 N-m) ± 5 in. lbs. (0.6 N-m). c. If separate external grounding is not required, bond across splice to either ground stud. 7

5.4 Strength Member Termination for Non-Shielded Cable a. Cut strength member 1.75" (44.5 mm) from cable sheath end. 1.75" (44.5 mm) b. Install strength members into 3M 2172 Strength Member Clamp by loosening screw and placing strength member under screw assembly. Insure strength member is flush with end of clamp prior to tightening the screw. Install rubber boot onto clamp. If necessary to insure proper fit, remove excess coating on strength member. 8

5.5 Insert two cable tie down brackets into the plastic "U" channels near the cable entry ports. 5.6.1 Build cable entrance seals by wrapping sealing tape between sealing washers 2.0" (51 mm) from each cable sheath end. Wrap each cable until sealing tape outside diameter (OD) is flush with sealing washer OD. Sealing tape must be flush with sealing washer diameter OD of 1.31" (33 mm). The maximum tape diameter OD should be no more than 1.4" (36 mm). cable tie down bracket 5.6.2 Press cable entrance seals into cable ports as shown. 5.7 Attach cables to closure base, using one of the two methods below: 3M Scotchlok 4460-D/FO Shield Bond Connector: Attach each cable to closure base by installing a hose clamp around the cable and under the cable tie down bracket and tighten. 3M 2172 Strength Member Clamp: Attach each cable to closure base by installing a hose clamp through slot on the strength member clamp, then route hose clamp under cable tie down bracket and tighten. 9

5.8 Install one green cable tie on the "C.O. Cable" and trim. Install one blue cable tie on each "Field Cable" and trim. Cable ties may also be placed inside case per company standard practice. 5.9 Set screws to retain cable tie down bracket are installed at the factory. If removal is necessary, use the allen wrench included in the kit. One or both of the set screws can be removed. It is recommended to tape the allen wrench to the inside of the closure for later use. Set screw must not extend above plastic "U" channel. Install only till flush with "U" channel. 6.0 Buffer Tube Preparation 6.1 Gather all buffer tubes from "C.O. Cable" and install one green cable tie approximately 36" (914 mm) from sheath end. Install one blue cable tie on the "Field Cable" buffer tubes. Install two blue cable ties on "Branch Cable" buffer tubes. 6.2 Coil buffer tube bundles inside closure base per company standard or organizer installation instructions. 6.3 Install organizer and splice per company standard or organizer installation instructions. 10

7.0 Splice Cable Assembly If 3M 2183 Universal Aerial Hanger Bracket is to be used, follow its practice prior to splice case assembly. 7.1 Seal Closure Walls a. Lay sealing cord into channel along both sides of closure base. Do not stretch sealing cord. b. Lay two strips of sealing cord 1.5" (38 mm) in length over the word "mastic" between the cable entrance ports on each end of closure base. Lay strips side by side, not one on top of the other. 7.2 Seal Plug Construction a. Wrap each plug two times with sealing tape. Sealing tape OD should be flush with plug OD. b. Press seal plugs into each vacant cable entrance port. 7.3 Before placing closure cover on the closure base, insure that the air valve matches up with "Air Valve End" note on base. 7.4 Screw all bolts until they have been threaded several complete turns into the nut inserts. 7.5 Tighten ten (10) bolts half way down in sequence shown. Then tighten ten (10) bolts in sequence shown until there is metal to metal contact. Bolts may be partially pulled down with air impact wrench. Final tightening should be done with a hand wrench to 20 ft.lbs. (27.12 N-m) torque. Case leakage may occur if procedure is not followed. See label and numbers on cover of splice case. 7.6 After 5 minutes, retighten bolts to 20 ft.lbs. (27.12 N-m) maximum. 7.7 Flash test splice case with 8 psi (.55 bars) MAXIMUM, THEN RELEASE PRESSURE. 7.8 If leaks are detected, retighten bolts. 9 6 2 4 8 10 3 1 5 7 11

8.0 Splice Case Reentry 8.1 Remove the 10 bolts holding splice case halves together. See label on cover of splice case. 8.2 Using four of these bolts, loosely screw one bolt into each of the four threaded corner inserts in the closure cover. 8.3 Beginning in any corner, screw in bolt until the closure halves been pried apart about.25" (6 mm). Repeat with the other bolt on same end of closure. 8.4 Follow same procedure with the bolts on opposite end of closure. Continue screwing bolts in.25" (6 mm) increments until the case halves can be easily separated by hand. If splice case is to be reassembled, old sealant must be removed and cable entrance port seals reconstructed. The 2180 Cable Kit is needed to reseal splice case. Important Notice All statements, technical information and recommendations related to the Seller's products are based on information believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use. Any statements or recommendations of the Seller which are not contained in the Seller's current publications shall have no force or effect unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein are made in lieu of all warranties, expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose which warranties are hereby expressly disclaimed. SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS. Telecom Systems Division 6801 River Place Blvd. Austin, TX 78726-9000 800/426-8688 www.3m.com/telecom Printed on 50% recycled paper with 10% post-consumer 12 Litho in USA 3M 1998 34-7041-6288-1-B