Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description



Similar documents
Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Safety technique. Emergency stop module BO 5988 safemaster

Electronic overload relay EF19 and EF45

Analog signal converters CC-E I/I Current / current isolators

RM4TG20 three-phase network control relay RM4-T - range V

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Electronic overload relay EF65, EF96 and EF146

Three-phase monitoring relay CM-PFE

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

38 Series - Relay interface modules A

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Technicaldata General

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Logic module AC010. Content. Logic module AC010

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

38 Series - Relay interface modules A

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

48 SERIES Relay interface modules 10 A

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

80 Series - Modular timers 16 A. Features

Redundancy Module QUINT-DIODE/40

Pluggable interface relays CR-P Pcb relays

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Control Devices Catalogue. Control Devices. Preferred and Standard Products

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Thermistor motor protection

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

E-STOP relays, safety gate monitors

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Catalog. Modular DIN rail components Installation contactors

Preset Counter signo 721

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

EMR measuring and monitoring relays

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

80 Series - Modular timers 16 A. Features

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

49 Series - Relay interface modules A. Features

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Quick Connect. quick - simple - efficient.

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Relés e Contatores de Estado Sólido SIRIUS

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Bimetallic Overload Relay Specifications

E-STOP relays, safety gate monitors

Easy Multifunctional Safe

PHOENIX CONTACT - 01/2007

Technical catalogue. Modular DIN rail components Installation contactors

PHOENIX CONTACT Features

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

40.3. Control Relays and Timers

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Power Supplies 3. SDN-P DIN Rail Series

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Contact expansion modules

E-STOP relays, safety gate monitors

Contact expander modules

E-STOP relays, safety gate monitors

40 Series - Miniature PCB/Plug-in relays A. Features

Manual motor starter MS116

60 Series - General purpose relays 6-10 A. Features

PNOZsigma - Base units

E-STOP relays, safety gate monitors

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

SINEAX U553 Transducer for AC Voltage

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Telephone- and leased line modem for industrial applications TD-36

Voltage Regulator SPAU 341 C. Product Guide

T0118 T2118 T3118. Instruction Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual

Digital input modules

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Transcription:

Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display Operating buttons Screw terminals Timer Can be expanded using easy expansion units tes concerning the product group Backup of real time clock (only for appropriate devices) Backup time (hours) 1

Operating time (years) General Standards EN 55011, EN 55022, IEC/EN 61000 4, IEC 60068 2 6, IEC 60068 2 27 Dimensions (W H D) mm 107.5 90 58 (6 PE) Weight kg 0,3 Mounting Terminal capacities Top hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4 101 GF1 (accessories) Solid mm 2 0.24 (AWG 22 12) Flexible with ferrule mm 2 0.22.5 (AWG 22 12) Standard screwdriver mm 3.5 0.8 Max. tightening torque Nm 0,6 Climatic environmental conditions Operating ambient temperature C Condensation LCD display (clearly legible) C 055 Storage C 40/+70 Relative humidity, non condensing (IEC/EN 60068 2 30) 25 to 55, cold as per IEC 60068 2 1, heat as per IEC 60068 2 2 Take appropriate measures to prevent condensation % 5 95 Air pressure (operation) hpa 795 1080 Corrosion resistance IEC/EN 60068 2 42 4 days SO 2 cm 3 /m 3 10 IEC/EN 60068 2 43 4 days H 2 S cm 3 /m 3 1 Ambient conditions, mechanical Pollution degree 2 Degree of protection (IEC/EN 60529) Vibrations (IEC/EN 60068 2 6) IP 20 Constant amplitude 0.15 mm Hz 10 57 Constant acceleration 2 g Hz 57 150 Mechanical shock resistance (IEC/EN 60068 2 27) semi sinusoidal 15 g/11 ms Impacts 18 2

Drop to IEC/EN 60068 2 31 Drop height mm 50 Free fall, packaged (IEC/EN 60068 2 32) Mounting position Electromagnetic compatibility (EMC) Electrostatic discharge (IEC/EN 61000 4 2, Level 3, ESD) m 1 Air discharge kv 8 Contact discharge kv 6 Electromagnetic fields (IEC/EN 61000 4 3, RFI) Radio interference suppression (EN 55011) Burst pulses (IEC/EN 61000 4 4, level 3) V/m 10 Supply cables kv 2 Signal lines kv 2 High energy pulses (surge) (IEC/EN 61000 4 5) High energy pulses (surge) (IEC/EN 61000 4 5, level 2) Immunity to line conducted interference to (IEC/EN 61000 4 6) Insulation resistance Clearance in air and creepage distances kv kv V 10 horizontal/vertical Insulation resistance EN 50178 Backup/accuracy of the real time clock Accuracy of the real time clock Repetition accuracy of timing relays Accuracy of timing relays (of values) % ± 1 Resolution Range S ms 10 Range M:S s 1 Range H:M min 1 Retentive memory EN 55011 Class B, EN 55022 Class B 2 (supply cables, symmetrical, EASY...AC) 0.5 (supply cables, symmetrical, EASY...DC) EN 50178, UL 508, CSA C22.2, no. 142 rmally ± 5 (± 0.5 hyear) Write cycles of the retentive memory 1000000 (10 6 ) Power supply Rated operational voltage U e V 24 DC ( 15/+20%) Admissible range V DC 20,4 28,8 Residual ripple % 5 3

Input current Input current 115/230 V AC ma rmally 140 Voltage dips (IEC/EN 61131 2) ms 10 Heat dissipation W rmally 3.5 Digital inputs 24 V DC Number 12 Inputs can be used as analog inputs 4 (I7, I8, I11, I12) Status indication Potential isolation From power supply Between digital inputs From the outputs Rated operational voltage U e V DC 24 LCD display (if present) On 0 signal U e V DC < 5 (I1 I12, R1 R12) On 1 signal U e V DC Input current on 1 signal Yes > 15.0 (I1 I6, I9, I10), > 8.0 (I7, I8, I11, I12) I1 to I6 ma 3.3 (at 24 V DC) I7, I8 ma 2.2 (at 24 V DC) I9, I10 ma 3.3 (at 24 V DC) I11, I12 ma 2.2 (at 24 V DC) Delay time from 0 to 1 Debounce ON ms 20 Debounce OFF ms rmally 0.25 (I1 I12) Delay time from 1 to 0 Debounce ON ms 20 Cable length (unscreened) m 100 Frequency counter Quantity 2 (I3, I4) Counter frequency khz < 1 Pulse shape Pulse pause ratio 1:1 Rapid counter inputs Square Number 2 (I1, I2) Counter frequency khz < 1 Pulse shape Pulse pause ratio 1:1 Analog inputs Square Quantity 4 (I7, I8, I11, I12) 4

Potential isolation From power supply From the digital inputs From the outputs From the PC interface, memory card NET network, EASY Link Input type Yes DC voltage Signal range V DC 0 10 Resolution, analog V 0,01 Resolution, digital V 0,01 Resolution, digital Bit 10 (value 0 1023) Input impedance k 11,2 Accuracy of actual value Two EASY devices % ± 3 Within a single device % ± 2, ± 0.12 V Conversion time, analog/digital Input current ma < 1 Cable length screened m < 30 Relay outputs Number 6 Outputs in groups of 1 Parallel switching of outputs for increased output Protection of an output relay Potential isolation From power supply From the inputs From the PC interface, memory card NET network, EASY Link ms Debounce ON: 20; Debounce OFF: every cycle time t permissible Miniature circuit breaker B16 or fuse 8 A (slow) Yes Yes Safe isolation V AC 300 Basic insulation V AC 600 Lifespan, mechanical Operations 10 6 10 Contacts Conventional thermal current (10 A UL) Recommended for load: 12 V AC/DC A 8 ma > 500 5

Short circuit proof cos = 1, characteristic B16 at 600 A Short circuit proof cos = 0.5 to 0.7, characteristic B16 at 900 A Rated impulse withstand voltage U imp of contact coil A 16 A 16 kv 6 Rated operational voltage U e V AC 250 Rated insulation voltage U i V AC 250 Safe isolation to EN 50178 between coil and contact Safe isolation to EN 50178 between 2 contacts Making capacity V AC 300 V AC 300 AC 15, 250 V AC, 3 A (600 Ops./h) Operations 300000 DC 13 L/R 150 ms 24 V DC, 1 A (500 Ops./h) Breaking capacity Operations 200000 AC 15, 250 V AC, 3 A (600 Ops./h) Operations 300000 DC 13 L/R 150 ms 24 V DC, 1 A (500 Ops./h) Filament bulb load Operations 200000 1000 W at 230/240 V AC Operations 25000 500 W at 115/120 V AC Operations 25000 Fluorescent lamp load Fluorescent lamp load 10 58 W at 230/240 V AC With upstream electrical device Operations 25000 Uncompensated Operations 25000 Fluorescent lamp load 1 58 W at 230/240 V AC, conventional, compensated Switching frequency Operations 25000 Mechanical operations 10 6 10 Switching frequency Hz 10 Resistive load/lamp load Hz 2 Inductive load Hz 0,5 UL/CSA Uninterrupted current at 240 V AC A 10 Uninterrupted current at 24 V DC A 8 AC Control Circuit Rating Codes B 300 Light Pilot Duty 6

(utilization category) Max. rated operational voltage V AC 300 Max. thermal uninterrupted current = 1 at B 300 Max. make/break capacity 1 at B 300 DC Control Circuit Rating Codes (utilization category) A 5 VA 3600360 Max. rated operational voltage V DC 300 Max. thermal uninterrupted current at R 300 A 1 Max. make/break capacity at R 300 VA 2828 Analog outputs Potential isolation From power supply From the digital inputs Signal range V DC 0 10 Conversion time, analog/digital tes Dimensions tes ms R 300 Light Pilot Duty Debounce ON: 20; Debounce OFF: every cycle time For additional Technical Data EASY5... and EASY7... AWB2528 1508GB, EASY8... AWB2528 1423D Dimensions 7

Moeller GmbH, Hein Moeller Str. 7 11, D 53115 Bonn E Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. Subject to modifications. HPL C2006GB INT V2.3 8