Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Similar documents
Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

How To Run A Data Center Efficiently

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Comprehensive Data Center Energy Management Solutions

Comprehensive Data Center Energy Management Solutions

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

CUSTOMER EXPERIENCE CENTER

Microsoft Technology Center: Philadelphia

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

DCIM Readiness on the Rise as Significant Data Center Capacity Remains Unused. A Research Report from the Experts in Business-Critical Continuity TM

XWEB EVO Supervisor and Monitoring Systems. November 2014

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

TABLE OF CONTENTS. 1.1 Features System Screen Main Unit Screen Navigating Through the Liebert icom Menus...

AIRAH Presentation April 30 th 2014

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

TABLE OF CONTENTS. 1.1 Features Control Interface Large Display Navigating to Various Views in the Liebert icom...

POWER. Your Partners in Availability POWER

How To Save Energy On A Power Supply

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

SUN ORACLE DATABASE MACHINE

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s

Hospital IT and Facilities Special Report Top concerns in the hospital include budget, power requirements

How is Dew Point Measured Reliably?

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

Liebert icom - PEX Product Application

Application Guide Guardian Over the NET Server Room Solution

Panduit Infrastructure Management Software for Data Centers and Enterprises

Power & Environmental Monitoring

Using CFD for optimal thermal management and cooling design in data centers

Revolutionizing Data Center Infrastructure Management

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling

Environmental Data Center Management and Monitoring

Managing Cooling Capacity & Redundancy In Data Centers Today

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

FAC 2.1: Data Center Cooling Simulation. Jacob Harris, Application Engineer Yue Ma, Senior Product Manager

Energy Efficiency and Availability Management in Consolidated Data Centers

Protecting Our Information, Protecting Our Resources

Enterprise Remote Monitoring

DCIM Data Center Infrastructure Monitoring

Model Manage Monitor Maximize your Data Center

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

How To Improve Energy Efficiency In Data Center Management

Directed Circuits Meet Today s Security Challenges in Enterprise Remote Monitoring. A White Paper from the Experts in Business-Critical Continuity TM

Case study: End-to-end data centre infrastructure management

Emerson Smart Firewall

Precision versus Comfort Cooling Choosing a Cooling System to Support Business-Critical IT Environments

Liebert. Liebert Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

Data Center Lifecycle and Energy Efficiency

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

Data Center Technology: Physical Infrastructure

Server Technology, Inc.

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Infrastructure & Cities Sector

Improve competiveness of IDC and enterprise data centers with DCIM

Data center upgrade proposal. (phase one)

Data Center Cooling A guide from: Your partners in UPS Monitoring Systems

Liebert PEX Efficiency And Reliability For High Availability Cooling. Next Generation Critical Cooling for Room and Row

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM)

Maximizing return on plant assets

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Introducing AUDIT-BUDDY

DATA CENTER ASSESSMENT SERVICES

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Data Loggers for Real Time Temperature Monitoring - WiFi

Applying Data Center Infrastructure Management in Collocation Data Centers

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Reducing Data Center Energy Consumption

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Wireless Field Data Backhaul

SUN ORACLE DATABASE MACHINE

Metering for today s systems

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Transcription:

Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

All for One, One for All Optimize a Single Cooling Unit an Intelligent Control and Good Things Happen. Integrate multiple cooling units into an intelligent system, all working toward one goal, and even better things happen. Such as a 50% reduction in energy consumption. And when they re controllable from one pane of glass? Data center managers get the comprehensive thermal management tools they need to meet the high expectations being placed on their environments. Introducing the New Era of Environmental Control The all-new Liebert icom thermal controls offer thermal management optimization at both the unit and system levels, with easy-to-use, touch screen interfaces that give data center managers the insight needed to maximize performance. At the cooling unit level, the unit control provides the highest protection available and optimal performance. Monitors 380 unit and component points to eliminate single points of failure Self-healing features avoid passing unsafe operating thresholds Highly intuitive, full-color, touch screen simplifies operations to save time and reduce human error Multiple, automated unit protection routines, including lead/lag, cascade, rapid restart, refrigerant protection and valve calibration 30% lower deployment costs At the supervisory level, the -S system control offers a revolutionary way to harmonize and optimize thermal system performance to optimize capacity across the data center, gain quick access to actionable data, and automate system diagnostics and trending. Advanced monitoring and at-a-glance reporting on performance metrics and trends for efficiency, capacity and adverse events Up to 50% system efficiency gains Teamwork modes that prevent conflict between units and allow them to adapt to changes in facility and IT demand to improve efficiency and availability and reduce system wear and tear saving more than $10,000 per unit per year in energy costs Simple and easy to deploy auto-configuration to detect and configure up to 4,800 sensors, eliminating the need for custom integration to building management systems and cutting sensor deployment times in half unit control and -S system control are available for new Emerson Network Power data center cooling units or as retrofits. 2

Simplify Thermal System Management for Protection, Efficiency & Insight Liebert icom Unit Control -S System Control Description Mission critical unit control for greater protection Available on new Emerson cooling units and backward compatible for retrofits Supervisory, multi-unit mission critical control for higher efficiency and insight Direct Integration with unit controls, with U2U connection 9" color, resistive touch screen 22" color, high-definition, capacitive touch screen display 2 USB, 2 RS-485 and 2 Ethernet ports 48-port network switch - no monitoring cards required Integrated firewall/router LED and audible alarms Integrated Wi-Fi/Ethernet Protection and Insight Highest unit protection available 380 unit and component monitoring points Over 200 unit and component alarms Redundant unit failsafe modes Unit protection routines lead/lag, cascade Fast restart Refrigerant protection Automatic chilled water valve calibration Advanced monitoring and collaborative protection Efficiency, capacity and system performance monitoring, trending and planning Visual floor plan thermal sensor map High security mesh wireless sensor network Adaptive control for hot spot reduction and self-healing Efficiency 10-20% unit efficiency gains Up to 50% system efficiency gains Shared workload teamwork Advanced machine-to-machine (M2M) teamwork with wireless sensor integration Collaborative, non-fighting teamwork Independent airflow and temperature control with fan speed coordination Predictive auto-ecomomization Group/Zone control to reduce temperature variations Dew point, rack sensor, supply air, return air or differential pressure control Set point change coordination Deployment 20% reduction in deployment time/costs compared to integration and mapping each cooling unit to a building management system Quick start wizard set up BMS points generator tool Single wire unit-to-unit connection 1-hour retrofit installation Exportable configuration parameters and event history 30% lower wireless sensor deployment costs through automatic sensor configuration Automatic sensor detect and configuration for up to 4800 sensors Single connection point for all thermal equipment Integrated cable management and wall mounting bracket Single person installation Desk or wall-mount applications 3

Unit Control: Greater Protection Liebert icom controls enhance cooling unit operation and improve data center availability by protecting units from damage, with automated routines for unit protection, fast restart, unit cascading and contaminant removal. The unit control communicates alerts, auto-tunes key operating parameters, such as fan speed, compressor utilization and economization, and prevents cooling units from exceeding key threasholds. Faster Restart FASTER RESTART Dynamic Thermal Response No Cascade 120 Time/seconds 100 90 80 70 60 50 40 8 times faster Less rise in temperature Automated Cascade Remains Off 30 20 10 Standard Quick Start Activates Recovery times from loss of power or transfer to generator power are reduced. Faster restart decreases temperature rise during these events. Unit-to-Unit network established Automatic cascade and lead/lag routines activate and deactivate units based on room load to minimize hot spots and overheating. Auto Valve Calibration Refrigerant Protection High Pressure Trip Shutdown 100 % Valve Opening 50 Pressure 4 0 Longer valve life Time in Minutes Automatic valve calibration and valve type detection increase valve life expectancy by only moving the valve in increments that actually result in a change of water flow. They eliminate valve backlash and valve gear wear. Shutdown Freeze Cut Out Self-healing routines prevent DX refrigerant freeze. As refrigerant pressure approaches thresholds, the controls lower fan speed and compressor capacity so cooling is not disabled due to a low-pressure cut out. At the other end of the spectrum, the controls adjust the compressor down and raise fan speed so cooling is not disabled due to a high pressure condition.

Unit Control: Enhanced Efficiency, Faster Deployment Liebert icom unit controls improve efficiency with machine-to-machine collaboration and automated routines that adjust cooling unit capacity to environmental conditions. They also require little or no customization, reducing the need for expensive integration into building management systems. Energy Savings from Teamwork Mode Automated Economizer Switch Over For A Single Unit % Conflicting Operations Lost Hours Cost @$0.10 /kwh 30% 0% 2,268 0 $10,406 $0 Annual Economizer Hours Aditional Economizer Hours with Total $ Saving 2400 3500 45% (1100 hours / year) $17,600 / year Data center cooling units operate in conflict (cool/reheat) about 30% of the time. unit controls come pre-configured with teamwork control modes that automatically adjust cooling unit operations to reduce conflicts and enhance efficiency and availability. Savings From Using Dewpoint Control SAVINGS FROM USING DEWPOINT CONTROL 10 kw Energy Used 0 Energy Used Dew Point Humidity Control 60% RH The dew point control routine operates humidification and dehumidification from dew point instead of relative humidity. This prevents activation of these components based on large temperature changes, thereby saving energy 72 F 50% RH 75 F 40% RH Using RH Humidifier Remains ON Using Dewpoint Humidifier is OFF Absolute Humidity, Grains/lb ma 20 Units 8kW savings / unit during economization 10 Cents / kw Economizer control routines automatically switch over to economization when the environment allows, increasing economization hours, eliminating the need for custom controls and removing human error. (using custom controls) ( Teamwork) SAVINGS with CONTROLS DEPLOYMENT SAVINGS Reduce Deployment Costs Unit Control Programming Site Control Programming $10,000 $40,000 Ships pre-configured $10,000 $10,000 $30,000 $40,000 (or 80%) Controls come pre-configured for unit-to-unit communications to reduce energy consumption and increase performance. Little or no customization is needed, unlike building management system applications, which require significant on-site programming. 5

System Control: Greater Protection and Insight Liebert icom -S system controls allow data centers to more easily reach and maintain the optimal balance point of matched cooling capacity and IT load. They accomplish this by monitoring the data center environment through wired or wireless sensors and controlling the operation of multiple cooling units through machine-to-machine communications. Failsafe routines automatically activate to protect against adverse events. Streamlined Connectivity Timeout and Failover Protection TIMEOUT AND FAILOVER PROTECTION BMS WirelessControl to Gateways & Sensors Control Variable from BMS Lead Controller - A/C Unit #1 A/C Unit #2 A/C Unit #3 Liebert icom-s System Control Lead Controller - A/C Unit #1 A/C Unit #2 A/C Unit #3 BMS Direct connections with cooling units and sensors gateways eliminating the possibility of third party systems interferring with unit operation, causing downtime. Timeout and failover scenarios allow hand-shaking between cooling units and the system control. Fail-safe scenarios ensure data center uptime and reliability. controls in place, if a lead unit were to fail, then the other units relying upon it would also fail. controls in place, the other units remain operating. Wireless Sensor Mesh Protection WIRELESS SENSOR MESH PROTECTION Zone Backup Protection Unit fails, no backup zoning control Unit cooling is lost No Sensor Redundancy, Data Interrupted Sensor Redundancy, Data Not Interrupted Secure sensor mesh eliminates single points of failure by providing automatic backup in the event a sensor fails. Unit fails, backup zoning assigned Cooling maintained by other units Backup zoning control assigns primary and secondary areas of influence for each cooling unit in case units fail to maintain room service levels. Insight for Action -S system controls gives unsurpassed visibility into thermal system operations. High definition touch screen allows users to easily configure, monitor and enhance the data center cooling from a central location Visual thermal sensor map Alarm management displays allow users to quickly view event notifications and pinpoint problems Trending reports provides historical information for infrastructure planning and performance tracking Displays key metrics on data center environmental conditions and cooling unit performance and health 6

System Control: Greater Efficiency, Faster Deployment Liebert icom -S system controls harmonize and optimize thermal system performance across the data center, and provide quick access to actionable data, including system diagnostics and trending. Automated routines and machine-to-machine communications allow the system as a whole to adapt to changes in facility-level demand as efficiently as possible. Simplified configuration routines and functions speed deployment. M2M Control for Energy Savings SERVER RACK Recirculation SERVER RACK SERVER RACK -S controls decouple cooling components compressors, chilled water valves and economizers from fan operation, allowing them to operate independently. This matches airflow and temperature to changing IT load requirements and maximizes the efficiency of each component. Air is returned to the cooling units at a higher temperature resulting in higher efficiency. Quickly Import Floor Plans Fan Speed Coordination Delivers Air Based on IT Equipment Demand Energy Savings Energy $ / Year Unit 1 Fan Speed Unit 2 Fan Speed Unit 3 Fan Speed Unit 4 Fan Speed Unit 5 Fan Speed Total CFM -S -S 40% $18,255 $11,540 30% 60% 35% 60% 75% 60% 100% 60% 60% 60% 122,000 122,000 Machine-to-machine communications and advanced algorithms coordinate fan speeds to achieve needed airflow at optimal efficiency. Eliminate Excessive Sensor Wire Runs ELIMINATE EXCESSIVE SENSOR WIRE RUNS Build floor plan in vendor tool More than 4 Hours Import floor plan Less than 30 Minutes Allows users to easily upload their data center floor plan and configure their thermal system. Capacity with IT Load -S -S Low Load Low Load Unit 1 50% OFF Unit 2 50% 50% Unit 3 50% OFF Unit 4 50% 50% Unit 5 50% OFF Energy $6,681 $2,672 CFM 60,000 24,000 -S controls automatically adjust cooling units to match cooling unit capacities to the IT load, even at extreme low load conditions. controls, cooling units may overcool the data center, resulting in wasted energy. *IT Required CFM = 20,000 * Min Unit Fan Speed = 50% Daisy chaining configuration for data center sensors significantly reduces the number of wire runs to the system control. Sensor Auto Configuration AUTO CONFIGURATION Reduce Sensor Deployment Costs 5 Days 500kW Datacenter: 100 racks, 200 sensors, 36 cooling units in 6 groups 2 Days 60% Reduced Sensor Deployment Time Easy configuration and binding of sensors and cooling units cut deployment times by days. 7

Quick Specs: Liebert icom Unit Control 9 (16:9) HD display Resistive touch screen so service personnel do not have to remove gloves Display can function as a hand-held device when the cooling unit is in service mode 2 USB Ports for simple software updates and system backup and restores 2 Ethernet ports for single line connection and integrated open protocols, such as BACNet, Modbus, SNMP, SMS and SMTP RS-485 ports to connect into smart devices like EC fans, compressors and heat rejection Quick Specs: -S System 22 1920 x 1080 (16:9) high-definition capacitive multi-touch screen with mounting hardware 2 x USB 3.0 Ports 1 x HDMI output 48-port network switch 4-port router Connects directly into machine-to-machine network for Liebert icom unit controls Power connection for up to 16 daisy-chained gateways (4,800 wireless sensors) Room editor to customize floor plan and layout Expansion Options 100 wireless modules with 3 sensors per module Optional wired sensors direct to units for backup Additional network switches for additional unit connectivity While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2015 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Liebert is a registered trademark of the Liebert Corporation. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2015 Emerson Electric Co. SL-18843 (R09/15) Printed in USA Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) Contact@EmersonNetworkPower.com EmersonNetworkPower.com