CLIMATIC Test Report



Similar documents
INTERNATIONAL STANDARD

High-ohmic/high-voltage resistors

IntesisBox KNX LG Air Conditioning

Digital input modules

CompactLogix Power Supplies Specifications

Bimetallic Overload Relay Specifications

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Precision Leaded Resistors

Incubator with mechanical convection

TEST REPORT EN (1997) +A1 (2001)

Modbus Server SAMSUNG Air Conditioners

Material test chamber with mechanical convection

THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS

1756 ControlLogix Chassis Specifications

Duct Humidity Transmitter

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

High-ohmic/high-voltage resistors

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0)

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

SYSTEM DESCRIPTION Termination Boards

Partial GSM TEST - REPORT

SURGE PROTECTIVE DEVICES

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

DHT11 Humidity & Temperature Sensor D-Robotics UK (

IntesisBox KNX Mitsubishi Heavy Industries AC

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Instruction Manual. T3111 T3111L T3111P T3111Ex

Know what is going on inside the mold.

How to Test a Combi Control Unit

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Temperature Transmitters ZTT series

1788 Linking Device Specifications

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

Inductive sensor NI10-M18-Y1X-H1141

DOCUMENTATION PD16 CP3-SVE-M75DC-24

Preset Counter signo 721

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Solar energy Solar technology in endurance testing

Accessories SUNNY REMOTE CONTROL

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

Test Report #: Date: April 8, 2005

ABB i-bus EIB / KNX Weather Station WS/S 4.1

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Specifications for DRIVER S REAR VIEW CAMERA

AC and Pulse Film Foil Capacitors KP Radial Potted Type

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

TX OPEN RS232/485 module

IntesisBox Modbus Server SAMSUNG Air Conditioners

Three-phase monitoring relay CM-PFE

ETSI EN V2.1.2 ( )

LwLVision-USB 2.0. Installation Guide

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ABB i-bus EIB Logic Module LM/S 1.1

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Online EFFECTIVE AS OF JANUARY 2013

Technology: Heating, Ventilation and Air Condition (HVAC) Zone Controls

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

User Manual Weather station V 0.2

User Manual. For more information visit

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

BATRON DOCUMENT NUMBER AND REVISION VL-FS-BTHQ 21605VSS-02 REV.A (BTHQ 21605VSS-FSTF-LED05W(1 DIE)) Feb/2002 BTHQ FSTF-LED WHITE 1/15

Hardware Manual RM CANview Ethernet

Pocket Tach 99 (PT99) Non-Contact Tachometer

Product and functional description

MOUNTING AND OPERATING INSTRUCTIONS

Bar code scanners CLV45x / CLV450 / Standard Density

IntesisBox Modbus Server - Mitsubishi Electric G50

PCB Relays Twin Relays

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Heating oven with mechanical convection

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

High Surge Axial Cemented Wirewound Resistors

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

MD SD MS SS MH SH ML SL MT ST

Precision Lightmeters Made in Germany

Sebert Group Structure Sebert Schwingungstechnik GmbH

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

Heating oven with mechanical control

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

High Ohmic (up to 68 MΩ)/ High Voltage (up to 10 kv) Resistors

Design qualification and type approval of PV modules

Parallax Serial LCD 2 rows x 16 characters Non-backlit (#27976) 2 rows x 16 characters Backlit (#27977) 4 rows x 20 characters Backlit (#27979)

Professional Thermohygrometer

Check-list for auditors. Audit visit at candidate registered laboratories

Transcription:

CLIMATIC Test Report ONLY FOR THE INTERNAL APPLICATION No. 200011.001internal for KFM 21_e Test Laboratory: Applicant: Purpose of Testing: Kontron Elektronik GmbH Oskar von Miller Straße 1 85386 Eching Germany Kontron Embedded Computers AG To show compliance with IEC 60068 PT2-1 IEC 60068 PT2-2 IEC 60068 PT2-14 IEC 60068 PT2-30 Special Measurement: none (see section "Reference Standards" for identical national standards) Note: The test data of this report relate only to the individual item tested. This report must not be reproduced unless explicitly approved by Kontron Embedded Computers AG. E00680.00 Status: 30.05.2003 Page 1 from 23

Table of Contents 1. Administrative Data...4 2. Summary of Test Results...5 3. Data of Operation Mode and Configuration of EUT...6 3.1 Operation Mode...6 3.2 Configuration of Cables of EUT...6 3.3 Configuration of EUT...6 3.4 Configuration of Peripherals of EUT...6 4. Performed Tests and Results...7 5. Annotations to Performed Tests and to CE certification...8 5.1 The Test in the Climatic Chamber...8 5.2 Basic environmental testing procedures...9 6. Referenced Regulations...10 7. List of Test Equipment...11 8. Photographs of EUT and Test Setup...12 9. Climatic conditions to IEC 60068...13 10. Temperature measurement...15 10.1 Layout : Temperature sensors KFM21_e...16 11. Temperature diagrams...17 11.1 IEC 60068 PT2-2 Non Operating...17 11.2 IEC 60068 PT2-1 Non Operating and...17 11.3 IEC 60068 PT2-30 Non Operating...17 11.4 IEC 68-2-1 Operating...18 11.5 IEC 68-2-2 Operating...19 11.6 IEC 68-2-14 Operating...20 11.7 IEC 68-2-14 Non Operating...21 12. Reference Standards...22 E00680.00 Status: 30.05.2003 Page 2 from 23

Table of Pictures Picture 1: Stabilizing period... Picture 2: Test Db test cycle...9 Picture 3: Recovery at controlled conditions...9 Picture 4 : IEC Climatic Chamber...12 Picture 5: IEC 60068 PT2-2 Test Bb: Dry heat for non-heat-dissipating specimen with gradual change of temperature...13 Picture 6: IEC 60068 PT2-14 Test Nb: Change of temperature with specified rate of change...13 Picture 7: IEC 60068 PT2-1 Test Ab: Cold for non heat-dissipating specimen with gradual change of temperature...14 Picture 8: IEC 60068 PT2-30,Test Db: 12+12 Hour Cycle...14 Picture 9: Mounting positions of the temperature sensors...16 Picture 10: Diagram of IEC 68-2-1 operating measurement...18 Picture 11: Diagram of IEC 68-2-2 operating measurement...19 Picture 12: Diagram of IEC 68-2-14 operating measurement...20 Picture 13: Diagram of IEC 68-2-14 non operating measurement...21 E00680.00 Status: 30.05.2003 Page 3 from 23

1. Administrative Data Equipment under test: KFM21_e optional Equipment under test: Options/accessories: None Serial number: 137868003 Version of EUT: Applicant (full address): Contract identification: Contact person: Manufacturer: Kontron Elektronik GmbH none none Kontron Elektronik GmbH Receipt of EUT: 12/07/2002 Date of test: 12/07/2002 Date of report 24/07/2002 Tested by: Test report by: Karlheinz Schiege Robert Hölzl Karlheinz Schiege Robert Hölzl Ralf J. Wagner E00680.00 Status: 30.05.2003 Page 4 from 23

2. Summary of Test Results The tested sample fully complies with the requirements set forth in IEC 60068 PT2-1 IEC 60068 PT2-2 IEC 60068 PT2-14 IEC 60068 PT2-30 (see section "Reference Standards" for identical national standards) Ralf J. Wagner Technical Manager Ralf J. Wagner Robert Hölzl Test Engineer E00680.00 Status: 30.05.2003 Page 5 from 23

3. Data of Operation Mode and Configuration of EUT 3.1 Operation Mode Special Susceptibility tests: Susceptibility tests: Windows Screen Saver none 3.2 Configuration of Cables of EUT 3.3 Configuration of EUT Display Samsung 21,3'' UXGA LTM213U3-L07 Backlight-Inverter Samsung SK2400H für LTM213U3-L07 Power supply Bicker SNP-Z107 Receiver Distec Prisma I (UXGA) Power filter Schaffner FN321-1/05 Operating-System 1 MS WIN 98 3.4 Configuration of Peripherals of EUT Channel Multiplexer Keyboard: Mouse: 8 Channel Cherry none Configuration optional none E00680.00 Status: 30.05.2003 Page 6 from 23

4. Performed Tests and Results Test Classification/Result Note IEC 60068 PT2-1 The requirements are fulfilled No degradation or loss of function or performance. IEC 60068 PT2-2 The requirements are fulfilled No degradation or loss of function or performance. IEC 60068 PT2-14 The requirements are fulfilled No degradation or loss of function or performance. IEC 60068 PT2-30 The requirements are fulfilled No degradation or loss of function or performance. E00680.00 Status: 30.05.2003 Page 7 from 23

5. Annotations to Performed Tests and to CE certification 5.1 The Test in the Climatic Chamber Climatic chamber Chamber Control Computer Damp, Heat, Cold Cyclic Agilent 20 Channel Multiplexer (Test value recording) Powersupply E00680.00 Status: 30.05.2003 Page 8 from 23

5.2 Basic environmental testing procedures Test Db and guidance - damp heat, cyclic 12+12 HOUR CYCLE (IEC 60068 PT2-30) The object of the test is to determine the suitability of components, equipment or other articles for use and/or storage under conditions of high humidity when combined with cyclic temperature changes. This test replaces the original Test D in the Publication 68-2-4 for future applications (the parameters takes from the page 14) Picture 1: Stabilizing period Picture 2: Test Db test cycle Picture 3: Recovery at controlled conditions E00680.00 Status: 30.05.2003 Page 9 from 23

6. Referenced Regulations (see section "Reference Standards" for identical national standards) Regulation IEC 60068 PT2-1 :1994 IEC 60068 PT2-2 :1994 EN 60068 PT2-2 :1993 IEC 60068 PT2-14 :1984 EN 60068-2-14 :1999 Comment ENVIRONMENTAL TESTING - TESTS A: COLD Concerns cold tests on both non-heat-dissipating and heat-dissipating specimens. ENVIRONMENTAL TESTING - TESTS B: DRY HEAT Contains Test Ba: Dry heat for non-heat-dissipating specimen with sudden change of temperature; Test Bb: Dry heat for non-heatdissipating specimen with gradual change of temperature; Test Bc: Dry heat for heat-dissipating specimen with sudden change of temperature; Test Bd: Dry heat for heat-dissipating specimen with gradual change of temperature. The 1987 reprint includes IEC No. 62-2-2A. ENVIRONMENTAL TESTING - PART 2-14 - TESTS - TEST N - CHANGE OF TEMPERATURE Determines the ability of components, equipment and other articles to withstand rapid changes of ambient temperature. The exposure times to accomplish this depend upon the nature of the specimen. IEC 60068 PT2-30 :1980 EN 60068-2-30 :1999 BASIC ENVIRONMENTAL TESTING PROCEDURES - TEST DB AND GUIDANCE - DAMP HEAT, CYCLIC (12+12 HOUR CYCLE) Determines the suitability of components, equipment and other articles for use and/or storage under conditions of high humidity when combined with cyclic temperature changes. Special standard E00680.00 Status: 30.05.2003 Page 10 from 23

7. List of Test Equipment Equipment Type Model Equipment No. Calibration valid until Manufacturer Climatic Chamber VUK 04-500 PM-EM-6160-1 08.99 Heraus-Vötsch Control computer IPLite Color PM-EM-9599.01 not requested Kontron Elektronik Measuring system 34970A PM-EM-9519.01 not requested HP/Agilent Control computer Rx7000 PM-EM-9597.01 not requested Kontron Elektronik (check mark in 1st column) = tested with E00680.00 Status: 30.05.2003 Page 11 from 23

8. Photographs of EUT and Test Setup Picture 4 : IEC Climatic Chamber E00680.00 Status: 30.05.2003 Page 12 from 23

9. Climatic conditions to IEC 60068 Temperatur C 55 C Humidity % rel. 50% 21 C rel. 20% 20 Min. 60 Min. 180 Min. 200 Min. Time (Min.) Picture 5: IEC 60068 PT2-2 Test Bb: Dry heat for non-heat-dissipating specimen with gradual change of temperature Temperatur C rel.humidity % TB=60 C 55% 21 C TA=0 C 0% 0 20 90 210 270 390 510 630 690 Time (Min.) Picture 6: IEC 60068 PT2-14 Test Nb: Change of temperature with specified rate of change E00680.00 Status: 30.05.2003 Page 13 from 23

Temperatur C rel.humidity % 21 C 55% T A=0 C 0% 0 30 90 210 270 Time (Min.) Picture 7: IEC 60068 PT2-1 Test Ab: Cold for non heat-dissipating specimen with gradual change of temperature Temperatur C rel.humidity % 95% 90% Ta 55 C 60% TA= 25 C 0 3 9 3 9 Time (h) 24h Picture 8: IEC 60068 PT2-30,Test Db: 12+12 Hour Cycle E00680.00 Status: 30.05.2003 Page 14 from 23

10. Temperature measurement Inquiry of the temperature limits at temperature critical components. Chosen critical components: Display Backside Controllerchip Power supply Backlight inverter System Ambient E00680.00 Status: 30.05.2003 Page 15 from 23

10.1 Layout : Temperature sensors KFM21_e Ambient Power Supply Unit Powersupply System Controllerchip Controllerchip Backlightinverter Display Backside Display Backside Picture 9: Mounting positions of the temperature sensors E00680.00 Status: 30.05.2003 Page 16 from 23

11. Temperature diagrams into dependence of the surroundings to IEC 60068 (temperature, atmospheric humidity) 11.1 IEC 60068 PT2-2 Non Operating have been done, but without recording 11.2 IEC 60068 PT2-1 Non Operating and have been done, but without recording 11.3 IEC 60068 PT2-30 Non Operating have been done, but without recording E00680.00 Status: 30.05.2003 Page 17 from 23

11.4 IEC 68-2-1 Operating 50,00 40,00 30,00 C 20,00 10,00 0,00-10,00 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 Time (Min) PSU Backlight Display Controllerchip System Ambient Picture 10: Diagram of IEC 68-2-1 operating measurement E00680.00 Status: 30.05.2003 Page 18 from 23

11.5 IEC 68-2-2 Operating 90,00 80,00 70,00 60,00 50,00 C 40,00 30,00 20,00 10,00 0,00 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 Time (Min) PSU Backlight Display Controllerchip System Ambient Picture 11: Diagram of IEC 68-2-2 operating measurement E00680.00 Status: 30.05.2003 Page 19 from 23

11.6 IEC 68-2-14 Operating 75,00 65,00 55,00 45,00 C 35,00 25,00 15,00 5,00-5,00 0 24 48 72 96 120 144 168 192 216 240 264 288 312 336 360 384 408 432 456 480 504 528 552 576 600 624 648 672 696 720 744 768 792 816 840 864 888 912 Time (Min) PSU Backlight Display Controllerchip System Ambient Picture 12: Diagram of IEC 68-2-14 operating measurement E00680.00 Status: 30.05.2003 Page 20 from 23

11.7 IEC 68-2-14 Non Operating 65,00 55,00 45,00 35,00 C 25,00 15,00 5,00-5,00-15,00-25,00 0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 800 840 880 920 960 Time (Min) PSU Backlight Display Backside Controllerchip System Ambient Picture 13: Diagram of IEC 68-2-14 non operating measurement 1000 1040 1080 1120 1160 1200 1240 1280 1320 1360 1400 1440 E00680.00 Status: 30.05.2003 Page 21 from 23

12. Reference Standards Tested standard IEC 60068 PT2-1 IEC 60068 PT2-2 IEC 60068 PT2-14 Reference Standard (identical/similar to) Identical with: BS EN 60068 PT2-1 DIN EN 60068 PT2-1 DIN IEC 68 PT2-1 EN 60068 PT2-1 HD 323.2.1 JIS-C0020 NEN 10068-2-1 NFC 20-701 NF EN 60068-2-1 SEN 43 16 01 SS EN 60068 Technical Equivalent to: AS 1099:PT2BA AS 1099:PT2BB AS 1099:PT2BC AS 1099:PT2BD JIS-C8938 Identical with: BS EN 60068 PT2-2 DIN EN 60068 PT2-2 DIN IEC 68 PT2-2 EN 60068 PT2-2 HD 323.2.2 JIS-C0021 JIS C0039 NEN 10068-2-2 NFC 20-702 NF EN 60068-2-2 SEN 43 16 02 SS EN 60068 Technical Equivalent to: AS 1099:PT2N AS 1099:PT2NA AS 1099:PT2NB AS 1099:PT2NC DIN EN 60068-2-14 JIS-C0025 Identical with: BS 2011:PT2.1N(1985) BS EN 60068-2-14 DIN IEC 60068-2-14 DIN IEC 68 PT2-14 EN 60068-2-14 HD 323.2.14 NEN 10068-2-14 NEN EN IEC 60068-2-14 NFC 20-714 NF EN 60068-2-14 SEN 43 16 13 SS EN 60068 E00680.00 Status: 30.05.2003 Page 22 from 23

Tested standard IEC 60068 PT2-30 Reference Standard (identical/similar to) Technical Equivalent to: AS 1099:PT2D JIS-C0027 Identical with: BS 2011:PT2.1DB(1981) BS EN 60068-2-30 DIN EN 60068-2-30 DIN IEC 60068-2-30 DIN IEC 68 PT2-30 EN 60068-2-30 HD 323.2.30 NEN 10068-2-30 NEN EN IEC 60068-2-30 NFC 20-730 SS EN 60068 E00680.00 Status: 30.05.2003 Page 23 from 23