Technical Info Sheet. Ionic contamination testing in a no-clean soldering process. Scope

Similar documents
Technical Spotlight. The Use of Ion Chromatography in the Printed Circuit Board Industry

How to Avoid Conductive Anodic Filaments (CAF)

Assembly and Cleaning. Prototype FDC Wire Boards

SURFACE INSULATION RESISTANCE TESTING OF SOLDERING PASTES AND FLUXES

IPC-SM-840C. Qualification and Performance of Permanent Solder Mask IPC-SM-840C. The Institute for. Interconnecting. and Packaging Electronic Circuits

Q&A. Contract Manufacturing Q&A. Q&A for those involved in Contract Manufacturing using Nelco Electronic Materials

Cleanliness of Electronic PCB Assemblies Leads to Medical Device Reliability

Effect of ionic contamination on climatic reliability of printed circuit board assemblies

17 IMPLEMENTATION OF LEAD-FREE SOLDERING TECHNOLOGY. Eva Kotrčová České Vysoké Učení Technické Fakulta Elektrotechnická Katedra Elektrotechnologie

The Study, Measurement, and Prevention of Tarnish on Immersion Silver Board Finishes

CHAPTER 5. OVERVIEW OF THE MANUFACTURING PROCESS

FLEXIBLE CIRCUITS MANUFACTURING

Classification of Chemical Substances

Metals and Non-metals. Comparison of physical properties of metals and non metals

Assembly of LPCC Packages AN-0001

DC MOTOR ANALYSIS & TROUBLESHOOTING

PCB Quality Inspection. Student Manual

Liquid Conductivity: Measuring Conductivity in Saline Water Solutions (Teacher s Guide)

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

Wetting Behavior of Pb-free Solder on Immersion Tin Surface Finishes in Different Reflow Atmospheres

Practices for Improving the PCB Supply Chain: Part II Cheryl Tulkoff DfR Solutions

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

Influence of CO2 Bubbling (Carbonation) During Semiconductor Wafer Sawing Process. KP Yan, Reinhold Gaertner, KK Ng

TAIYO PSR-4000MP LIQUID PHOTOIMAGEABLE SOLDER MASK

PIN IN PASTE APPLICATION NOTE.

Cleanliness of Stencils and Cleaned Misprinted Circuit Boards

Good Boards = Results

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

Fire Event Electronic and Mechanical System Damage Mechanisms Is Acid Gas for Real?

QUASAR ELECTRONICS KIT No ELECTRONIC MOSQUITO REPELLER

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Lead-free Wave Soldering Some Insight on How to Develop a Process that Works

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

JOHANSON DIELECTRICS INC Bledsoe Street, Sylmar, Ca Phone (818) Fax (818)

Customer Service Note Lead Frame Package User Guidelines

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

Fabrication of Complex Circuit Using Electrochemical Micromachining on Printed Circuit Board (PCB)

Electrical Conductivity of Aqueous Solutions

EXPERIMENT # 3 ELECTROLYTES AND NON-ELECTROLYTES

Cleaning Printed Circuit Assemblies Design & Process Control

Polymer Termination. Mechanical Cracking 2. The reason for polymer termination. What is Polymer Termination? 3

Damage-free, All-dry Via Etch Resist and Residue Removal Processes

RoHS-Compliant Through-Hole VI Chip Soldering Recommendations

Polyimide labels for Printed Circuit Boards

Chapter 13 Solution Dynamics. An Introduction to Chemistry by Mark Bishop

A. Types of Mixtures:

Metal Migration on Electric Circuit Boards

Test Methods for the Colour Fastness of Leather & Dyes. TFL Leather Technology Ltd. Quality and Environment February 2004 Version 1.

Micellar structures and Whisky

Cleaning and Cleanliness In IPC Specifications

Chemistry B11 Chapter 6 Solutions and Colloids

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

o Electrons are written in half reactions but not in net ionic equations. Why? Well, let s see.

Power chip resistor size 2512 PRC221 5%; 2% FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability.

Edition Published by Infineon Technologies AG Munich, Germany 2013 Infineon Technologies AG All Rights Reserved.

Nauki ścisłe priorytetem społeczeństwa opartego na wiedzy Artykuły na platformę CMS

Introduction to Photolithography Concepts via printed circuit board (PCB) manufacturing. PCB Background Information (courtesy of Wikipedia)

Chapter 5 Student Reading

Acceptability of Printed Circuit Board Assemblies

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

High Energy Rechargeable Li-S Cells for EV Application. Status, Challenges and Solutions

Keystone Exams: Chemistry Assessment Anchors and Eligible Content. Pennsylvania Department of Education

APPLICATION NOTES FOR SMD LEDs

PRDUCT SPECIFICATON TFT LCD MODULE Model : ELT240320ATP

SLLP G PRODUCT DATASHEET. RoHS Compliant

Lithium Carbon Monofluoride Coin Cells in Real-Time Clock and Memory Backup Applications

Chemistry 51 Chapter 8 TYPES OF SOLUTIONS. A solution is a homogeneous mixture of two substances: a solute and a solvent.

The soot and scale problems

Lead-free Hand-soldering Ending the Nightmares

Best Practices for Improving the PCB Supply Chain: Performing the Process Audit

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Chapter 4: Structure and Properties of Ionic and Covalent Compounds

Reliability Stress Test Descriptions

Electroplating with Photoresist Masks

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

How do you create a RoHS Compliancy-Lead-free Roadmap?

Separation by Solvent Extraction

A Study of Haze Generation as Thin Film Materials

Chapter 6. Solution, Acids and Bases

Chemistry B11 Chapter 4 Chemical reactions

LCD MODULE DEM SYH-LY

Chapter 5 Classification of Organic Compounds by Solubility

This chapter is devided into two sections:

PCB SPIU CLEANUP CAUSE AND EFFECT DIAGRAM. Bruce A. Bohnen Technical Director Integrated Chemistries, Incorporated 1970 Oakcrest Avenue, Suite 215

Specification. Li-ion Rechargeable Battery

4.5 Physical Properties: Solubility

BGA - Ball Grid Array Inspection Workshop. Bob Willis leadfreesoldering.com

Experiment #10: Liquids, Liquid Mixtures and Solutions

5s Solubility & Conductivity

CHEMISTRY STANDARDS BASED RUBRIC ATOMIC STRUCTURE AND BONDING

Chapter 13 - Solutions

Which substance contains positive ions immersed in a sea of mobile electrons? A) O2(s) B) Cu(s) C) CuO(s) D) SiO2(s)

the runnerless types of molds are explained post molding operations are described the basic methods of applied decoration methods are examined

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Application Note. Soldering Methods and Procedures for 1st and 2nd Generation Power Modules. Overview. Analysis of a Good Solder Joint

ISANE Isoparaffin Products

Transcription:

Scope This document provides information about ionic contamination testing and its relevance in a no-clean. Also so-called C3 testing and ROSE (Resistivity of Solvent Extract) testing are forms of ionic contamination testing. Ionograph for ionic contamination testing C3 test for local ionic contamination testing History Ionic contamination testing in the electronics industry was introduced to test the cleaning efficiency and stability of a cleaning process. Cleaning processes are usually required when aggressive chemistry is being used. The residues and/or reaction products of this aggressive chemistry can lead to detrimental effects like e.g. corrosion and electro(chemical) migration when they remain on the unit. Aggressive chemistry can be : - Electrolytic solutions in electrolytic processes in PCB manufacturing - Copper etching liquid in PCB manufacturing - Hot air levelling fluxes in PCB manufacturing - Water soluble soldering chemistry in PCB assembly - Residues of this kind of chemistry will strongly influence the readings/values of an ionic contamination test. If the values are out of range, usually it is an indication of a problem in the cleaning process. The nature of the chemistry that causes this out of range value is known (aggressive chemistry) and hence indicates a high risk on reliability problems. Ionic contamination testing is a useful tool for checking the process efficiency and stability of a cleaning process in an application where aggressive chemistry is being used. In this case it can give valuable information about chemical reliability of the residues. INTERFLUX Electronics N.V. - Technical Department Page 1 of 5

Working principle An extraction medium is being used to clean off and dissolve residues from the unit. Usually, a mixture of IPA and DI-water (often 75/25 vol %) is being used. C3 testing uses steam of DI-water. - IPA is known as a substance with low polarity. It has the ability to dissolve substances with similar polarity like e.g. most oils and resins. - DI-water (Demi water) is known as a substance with high polarity. It has the ability to dissolve substances with similar polarity with a high probability to dissociate them into ions. Ions are charged particles that support an electrical current which means that they will reduce the resistivity of the solution. This property is used for measurement in ionic contamination testing. - Steam of DI- water has very high solvent power due to its temperature. It can open up the structure of the surface so also subsurface substances can dissolve. It can also crack stable reaction products with the risk of creating other reaction products. + - - + + IPA : (CH3)2CHOH : low polarity Water: H2O : high polarity Example of dissociation in water: NaCl dissociates in water into Ions INTERFLUX Electronics N.V. - Technical Department Page 2 of 5

After dissolving the residues into the extraction medium, its resistivity is being measured by applying a DC voltage to it. - The amount of ions in the solution will determine the measured resistivity of the solution. - The ionic contamination value is then calculated from the measured resistivity and the surface from the unit. - The ionic contamination value is usually expressed in µg NaCl/cm² or in². NaCl is being used as a reference, it does not mean that NaCl is actually present. Measuring resistivity of the extraction medium Remarks This method only measures substances that can be dissolved in the extraction medium into ions. The ions are not present on the unit as such, they are being formed when dissolving into the extraction medium. This method does not provide any information about the nature of the substances that ionize in the extraction medium. To assess a possible reliability risk of these substances, more in depth testing is needed to identify the nature of these substances. How well the residues are exposed to the extraction medium influences how well they are being dissolved: residues underneath components, residues in shadow areas, INTERFLUX Electronics N.V. - Technical Department Page 3 of 5

The relevance of ionic contamination testing in a no-clean No- clean soldering chemistry is designed to remain on the electronic unit after soldering. When designed well, no-clean soldering chemistry has residues that are: - Non hygroscopic - Non conductive - Non corrosive - Non metal etching To a certain extent, residues of no-clean chemistry can be dissolved by extraction media used in ionic contamination testing and they can be measured. Due to the fact that these ions are not present on the board as such, but only in extraction medium, and the fact that the ionic contamination test does not provide any information about the nature of the ions, it does not give any information about the chemical reliability of the residues and hence is not a useful tool for assessing chemical reliability of no-clean soldering chemistry. Furthermore, many other sources beside no-clean soldering chemistry can give ionic contamination in a no-clean : - Components - PCB-boards - Handling - Contamination from production machines and carriers used in the process - To test the chemical reliability of the residues in a no-clean, more specific and dedicated test are being needed. Ionic contamination testing however can be used as a useful process control tool in a no-clean soldering process. In an established no-clean, the value of ionic contamination measured on a specific unit can be used as a reference value, when samples of this unit are being taken from the process for ionic contamination testing on a regular base. If the value of the sample deviates, it indicates that something has changed in the process. The possible causes of this change however are multiple and more in depth investigation will be needed to determine the real cause. Useful techniques can be: - SEM element analysis - FTIR-spectrum analysis - Ion Chromatography INTERFLUX Electronics N.V. - Technical Department Page 4 of 5

Testing chemical reliability of soldering chemistry Many different kinds of tests and standards exist to assess the chemical reliability of soldering chemistry: - Some are area related : European ( EN), Japanese ( JIS) German (DIN) standard, - Others are branch related: Telecom standard (Bellcore), Military standard ( Mil Spec), - Others are company specific : Siemens, Schneider, HP, - Most electronic manufacturers still refer to IPC: an American standardization organization The purpose of a chemical reliability test for soldering chemistry is to evaluate the effect of the residues and reaction products of this soldering chemistry on the functionality of an electronic circuit. Most popular tests are: - Surface Insulation Resistance test (SIR) - Electrochemical migration test (ECM) These tests use a defined test pattern that is being processed with the soldering chemistry. This pattern is powered with a defined voltage and submitted to high moisture and high humidity for a defined period time. In this period of time, the evolution of the Surface Insulation Resistance is being measured. Depending on the test, the values have to fulfill certain requirements. There is also a visual inspection for the formation of dendrites (electro chemical migration). As so many different parameters come together on an electronic unit beside soldering chemistry, there is a tendency not only to test the chemical reliability of the soldering chemistry on a test pattern, but to test the chemical reliability of the finished unit itself. The electronic unit that has been through all the process steps and has been produced with the actual materials is submitted to accelerated conditions that simulate as good as possible the conditions that the unit will be submitted to in the field. Conclusion Ionic contamination testing is not a useful tool for assessing chemical reliability in a no-clean soldering process. Ionic contamination testing can be a useful process control tool in a no-clean. Specifically designed tests exist for assessing chemical reliability in a no-clean. INTERFLUX Electronics N.V. - Technical Department Page 5 of 5