D-RB relay, fast switching + high DC breaking



Similar documents
KDN relay - Bi-stable / latching, Datasheet

Datasheet D- series relays

RY2 miniature industrial relays

SKR - industry relay

60 Series - General purpose relays 6-10 A. Features

AZ420 MINIATURE GENERAL PURPOSE RELAY

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

49 Series - Relay interface modules A. Features

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Plug-in relays Mini ISO relays

40 Series - Miniature PCB/Plug-in relays A. Features

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

38 Series - Relay interface modules A

Cable Plug acc. to DIN EN , Form A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

1 POLE - 8A Medium Load Control

General-purpose Relay

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

2 POLES - 5A LOW PROFILE TYPE

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Goodsky Technical Data. Contact Details

38 Series - Relay interface modules A

48 SERIES Relay interface modules 10 A

Model Number Structure

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

LAUBE TECHNOLOGY DRY REED RELAYS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Model Number Structure

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Thermal-Magnetic Circuit Breaker M1-..

RM4TG20 three-phase network control relay RM4-T - range V

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

SPST-NO SPDT DPST-NO DPDT

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

MasterINTERFACE 39 Series - Relay interface modules

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Pluggable interface relays CR-P Pcb relays

Technical Data. Dimensions

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

COMPACT POWER TWIN RELAY

Signal Relays AXICOM. P2 Relay V AXICOM Telecom-, Signal and RF Relays. P2 V23079 Relay. Coil Operating Range. Coil Data

TIG INVERTER INSTRUCTION MANUAL

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Elesta Elektrotechnik AG industry relays and accessories

Power Supplies 3. SDN-P DIN Rail Series

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Single Channel Loop Detector

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

Auxiliary Relay. Type P8n, PQ8n, PN8n

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection

High-ohmic/high-voltage resistors

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Solid-State Timer H3G

RELAYS Solar Energy Systems

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Problem / Solution. The problem:

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

1 POLE - 5A SLIM POWER RELAY

Telemecanique Zelio Relay complementary and easy to assemble

COMPACT POWER RELAY. FTR-P3 Series. For automotive applications 1 POLE-25A (for 12V car battery) FTR-K1 SERIES FEATURES PARTNUMBER INFORMATION

MasterINTERFACE 39 Series - Relay interface modules

ADM1TE 5/30A DIN rail single phase two wire energy meter

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

Telephone- and leased line modem for industrial applications TD-36

AXICOM Telecom-, Signal and RF Relays. Cradle Relay S V23054 / V Nov. 07 Rev. C ECOC: JM10

User s Manual Before using the inverter, you need to read and save the safety instructions.

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

1a/1c 5A/10A small power relays

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

DISCONTINUED (2009) RA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

Safety technique. Emergency stop module BO 5988 safemaster

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

High-ohmic/high-voltage resistors

Circuit Breakers. NRC Series. NRC Series

PCB Relays Twin Relays

MAXIMUM LOAD CURRENT 1 A SN SERIES

Transcription:

D-RB relay, fast switching + high DC breaking Datasheet capacity, 3 C/O, 0 A Features Short pull-in time (<7 ms) High DC breaking capacity Compact plug-in design Instantaneous, 3 C/O contacts Flat, square and silver relay pins for excellent connection in socket Wide range sockets Integrated retaining clip Transparent cover Flexibility by many options Solve-all relay application concept Benefits Application Plug-in, ultra rapid switching relay for reliable, low voltage applications in harsh environment. Proven reliable operation in switching high DC voltage/ inductive loads. Description The D-RB relays are designed for DC applications which requires very short operation times such as power control installations. The main characteristic of the D-series makes the D-RB relay suitable to withstand corrosive atmospheres, low and high temperatures and vibrating environments. The D-RB relays are equipped with built-in switched series-resistor for fast pull-in time. The magnetic arc blow ensures the DC breaking capacity and increase the contact life. Proven reliable Proven technology Long term availability Used in safety critical applications No maintenance Low life cycle cost Low energy consumption Industry compliancy EN 60255 Relay design and environmental conditions. EN 60947 Low voltage switch gear and control gear. EN 60947-5- Electromechanical control circuit devices and switching elements. IEC 680 Electromechanical elementary relays CE, RoHS, CB approved CCC approval pending

Smitt style pinning Magnetic arc blowout Transparant cover Solve-All D-RB D-RBA D-R D-RQ relay application concept From this datasheet it is obvious that the unique D-RB relay with all its options is designed in close cooperation with customers from the power utility industry. Below you will find some frequently used relay models as can be derived from this datasheet. Connection diagram 4 5 6 2 2 4 7 9 8 0 2

Coil data DC versions Operating times at nominal voltage: Pull-in time Release time Bounce time N/O contacts Bounce time N/C contacts Inductance L/R at Unom Energized Released Operating voltage range Nominal power consumption Min hold-up voltage * Operating voltage range (option V) 0.7...25 Unom 7 ms 0 ms 6 ms 8 ms ms 8 ms 0.8... Unom W at Unom (25 W at pull-in) 0.05 Unom Type Unom (V) Upull-in (V) Uhold-up (V) Umax (V) 40 C Rseries (Ω) Rcoil (Ω) 24 VDC 24 9.2.2 26.4 560 23.5 48 VDC 48 38.4 2.4 52.8 2200 94 60 VDC 60 48.0 3.0 66.0 3300 35 0 VDC 0 88.0 5.5 2.0 2000 50 25 VDC 25 00.0 6.3 37.5 5000 50 220 VDC 220 76.0.0 242.0 47000 850 * Other voltages on request * The coil resistance of the D relay is measured at room temperature and has a tolerance of ± 0 % Contact data Maximum make current Performance characteristics 6 A Maximum continuous current 0 A (AC; IEC 60947) Peak inrush current Maximum switching voltage Minimum switching voltage/current Material Contact gap Contact force Contact resistance 200 A (withstand 0 x 200 A @ 0 ms, min) 350 VDC, 440 VAC AG: 2 V, 0 ma (Au: µv, µa) Ag standaard (optional AgSnO2, Au on Ag) 0.7 mm (up to 4 mm for YX5 option) > 200 mn < 5 mω (initial) Mechanical life Rated switching frequency Dielectric strenght Pulse withstanding 50 x 0 6 cycles (unpowered) 200 ops/hour IEC 680-, 4 kv 50 Hz minute (between contacts) IEC 680-, 2.5 kv 50 Hz minute (between coil-contact) IEC 60255-5, 5 kv (.2/50 μs) 3

3 9 7 5 3 4 2 0 8 6 4 2 D-RB relay Mechanical data Dimensions (d, w, h) Weight Materials, non toxic. heat & fire resistant. 40 x 40 x 53 mm 40 g Polycarbonate, polyester Environment conditions Operating temperature -25 ºC...+55 ºC (-50 ºC when using option Y ) -25 ºC...+70 ºC (when using option V ) Shock IEC 60068-2-27, shocks: 5 g, 30 ms 6 directions Vibration IEC 60068-2-6, vibrations: 2 g, 5-50 Hz, 6 directions Humidity 95% RH / +40 C temporary condensation permitted Salt mist IEC 60068-2-, 5% NaCl, 35 C for 4 days Degree of protection IEC 60529, IP40 Dimensions 4

Options Code Description Remark Can not be combined with A Mechanical trip indicator indicates if the relay has been energized. K, W C Lower temperature features (-40 C) Max contact current 8 A (AC;IEC 60947) E Gold plated contacts (Au 0 μm) Low contact resistance and good M resistively against corrosive atmosphere. Suitable for switching low level dry circuit loads. K Extra dust protection. Cover sealed with sealant T M Highly resistant to welding (AgSnO 2 contacts) For safety and vital applications Min. contact current 00 ma Q Coil protection against transient voltage Double zener diode S Mechanical on/off position indicator Indicates visual the position T, W of the contacts. T Push to Test button, to manual operate the contact mechanically S, K V Wider operating range and ambient temperature Operating range: 0.7...25 Un Ambient temperature: -25 C...+70 C Power consumption 2.22 W X5 Contact gap of 2 mm higher DC breaking capacity and longer contact life. To increase the breaking capacity and contact life more this option can be combined with option B and Y Y Double break/double make contacts. Breaking capacity increased by 50% and longer contact life. To increase the breaking capacity and contact life more this option can be combined with option B and X5 Colored cover en keying of relay on socket on request 2 N/O and 2 N/C contacts 2 C/O DM/DB contacts E W W 5

In this section the most common breaking capacity for DC voltage / inductive load possibilities are presented with the different options and contact configurations within the D-R relays series. D-RB D-R D-RBA 4 5 6 4 5 6 4 5 6 2 2 4 7 9 8 0 2 2 4 7 9 8 0 2 2 4 7 9 8 0 3 C/O contacts Fast switching (<7 ms) Magnetic arc blow out Contact gap : 0.7 mm Breaking capacity DC 0 VDC 7 A 220 VDC 3 A L/R=40 ms 0 VDC 3 A 220 VDC A DC3 0 VDC - 220 VDC - 3 C/O contacts Fast switching (<7 ms) Contact gap : 0.7 mm Breaking capacity DC 0 VDC A 220 VDC 0.7 A L/R=40 ms 0 VDC 0.3 A 220 VDC 0. A DC3 0 VDC - 220 VDC - 3 C/O contacts Fast switching (<7 ms) Trip indicator Magnetic arc blow out Contact gap : 0.7 mm Breaking capacity DC 0 VDC 7 A 220 VDC 3 A L/R=40 ms 0 VDC 3 A 220 VDC A DC3 0 VDC - 220 VDC - D-RQ 4 5 6 2 2 4 7 9 8 0 3 C/O contacts Fast switching (<7 ms) Coil protection Contact gap : 0.7 mm Breaking capacity DC 0 VDC A 220 VDC 0.7 A L/R=40 ms 0 VDC 0.3 A 220 VDC 0. A DC3 0 VDC - 220 VDC - 6

Electrical life expectancy The life expectancy values shown below are based on factory tests (test frequency at /3 Hz). These values could be different in real life applications as environmental conditions, switching frequencies and duty cycles will influence these values. 00 Breaking capacity Relays (Inductive load L/R = 40ms) 0 DC current [A] D RB (4 CO) 0, 0 20 40 60 80 00 20 40 60 80 200 220 240 DC voltage [V] D R (4 CO) L/R=40ms 24VDC 0 D RB L/R=40ms 0VDC 0 D RB ( ops x 0 6 ) ( ops x 0 6 ) 0 2 4 6 8 Load current (A) L/R=40ms 220VDC D RB 0, 0 2 3 4 5 6 7 Load current (A) ( ops x 0 6 ) 0, 0,0 0 2 3 Load current (A) 7

Continuation 00 Breaking capacity Relays (Inductive load L/R = 40ms) 0 DC current [A] D RB (4 CO) 0, 0 20 40 60 80 00 20 40 60 80 200 220 240 DC voltage [V] D R (4 CO) L/R=40ms 24VDC 0 D RB L/R=40ms 0VDC 0 D RB ( ops x 0 6 ) ( ops x 0 6 ) 0 2 4 6 8 Load current (A) L/R=40ms 220VDC D RB 0, 0 2 3 4 5 6 7 Load current (A) ( ops x 0 6 ) 0, 0,0 0 2 3 Load current (A) 8

Sockets Mounting possibilities/sockets V2 V23 V23BR V29 V33 Surface/wall mounting 33800000 338000580 338000302 33830000 33800060 V2 V23 V22BR V24 V29 Bush connection screw socket, wall mount, front connection (2.5 mm 2 ) Screw socket, wall mount, front connection (7.5 mm terminals) Screw socket, wall mount, front connection (9 mm terminals) Faston connection socket, wall mount, front connection (6.3 mm) Spring terminal socket, wall mount, front dual connection (2.5 mm 2 ) Rail mounting 338000200 338000580 338000402 338300200 33800060 V2 V23 V23BR V25 V29 Bush connection screw socket, rail mount, front connection (2.5 mm 2 ) Screw socket, rail mount, front connection (7.5 mm terminals) Screw socket, rail mount, front connection (9 mm terminals) Faston connection socket, rail mount, front connection (6.3 mm) Spring terminal socket, rail mount, front dual connection (2.5 mm 2 ) Panel/flush mounting 33800000 32840000 338000560 338000570 V3 V26 V3 V33 Solder tag socket, panel mount, rear connection Crimp contact socket, panel mount, rear connection Faston connection socket, rear dual connection (5 mm) Cage clamp socket, flush mount, rear dual connection (2.5 mm 2 ) PCB mounting 33800056 V32 PCB soldering socket 9

Instructions Installation Before installation or working on the relay: disconnect the power supply first! Install socket and connect wiring according to the terminal identification. Plug relay into the socket ensuring there is no gap between the bottom of relay and the socket. Reverse installation into the socket is not possible due to the mechanical blocking snap-lock feature. Check to ensure that the coil connection polarity is not reversed. Relays can be mounted tightly together to save space. When surface/rail mounting is used, always mount the socket in the direction of the UP arrow. Warning! - Never use silicon spray in the proximity of the relays. - Do not use the relay in the presence of flammable gas as the arc generated from switching could cause ignition. - To remove relays from the socket, employ up and down lever movements. Sideway movement may cause damage to the coil wires. Operation After installation always apply the rated voltage to the coil to check correct operation. Long term storage may corrode the silver on the relay pins. When plugging the relay into the socket, the female bifurcated or trifurcated receivers will automatically cut through the corrosion on the pins and guarantee a reliable connection. Before actual use of relays, it is advised to switch the load several times with the contacts. The contacts will both be electrically and mechanically cleaned due to the positive wiping action. Sometimes a contact can build up increased contact resistance (< 5 mw when new). When using silver contacts one can clean the contact by switching a contact load a few times using >24 VDC & ~ 2 A. Increased contact resistance is not always problematic, as it depends on circuit conditions. Condensation in the relay is possible when the coil is energised (warm) and the outside, environmental temperature is cold. This is a normal phenomenon and will not affect the function of the relay. Materials in the relay have no hygroscopic properties. Maintenance Correct operation of the relay can easily be checked as the transparent cover provides good visibility of the moving contacts. If the relay does not seem to operate correctly, check for presence of the appropriate coil voltage and polarity using a suitable multimeter. If a LED is fitted, voltage to the coil presence should be indicated. If coil voltage is present, but the relay does not operate, a short circuit of the suppression diode is possible (This may be due to the coil connection having been reversed). If the relay doesn t work after inspection, replace the relay unit with a similar model. Do not attempt to open the relay cover or try to repair. Contacts are calibrated and in balance, touching can affect proper operation. Also resoldering may affect correct operation. Since 2009 relays have tamper proof seals fitted and once broken, warranty is void. Most relay defects are caused by installation faults such as over voltage, spikes/transients, high/short current far exceeding the relay specifications. When returning the relays for investigation, please provide all information on the RMA form. Send defective relays back to the manufacturer for repair or replacement. Normal wear and tear or external causes are excluded from warranty. 0

Ordering scheme D - RB 220 VDC. Relay series 2. Options 3. Coil voltage This example represents a D-RB 220 VDC. Description: D relay, Unom: 220 VDC, Umin:76 V, Umax: 242 V, 3 C/O contacts, fast switching (<7 ms) including arc blow-out.. Relay series D 2. Options A C E K M Q S T V X5 Y Keying Colour Trip indicator Low temperature (-40 o C) Gold plated contacts Cover sealed (IP50) AgSnO2 contacts Double zener diode Mechanical position indicator Push to test button Wider operating range and ambient temperature Contact gap 2 mm Double make double break contacts Coil coding for relay and socket Coloured cover for coil voltage 3. Coil voltages 5 VDC 6 VDC 7 VDC 8 VDC 2 VDC 4 VDC 8 VDC 20 VDC 24 VDC 28 VDC 30-32 VDC 36 VDC 42 VDC 60 VDC 65 VDC 72 VDC 80 VDC 00 VDC 0 VDC 20 VDC 27 VDC 35 VDC 36 VDC 40 VDC 220 VDC 240 VDC 250 VDC

D-RB series V.0 June 20 MS Relais SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 938 Rosny-sous-Bois Cedex, France T +33 (0) 482 440, F +33 (0) 4855 900 E sales@msrelais.com Mors Smitt Asia Ltd. # 807, Billion Trade Centre, 3 Hung To Road Kwun Tong, Kowloon, Hong Kong T +852 2343 5555, F +852 2343 6555 E info@morssmitt.hk Nieaf-Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, Netherlands T +3 (0)30 288 3, F +3 (0)30 289 886 E sales@nieaf-smitt.nl Mors Smitt Technologies inc. 420 Sackett Point Road North Haven, Ct 06473, USA T + (203) 287 8858, F + (888) 287 8852 E mstechnologies@msrelais.com Mors Smitt UK Ltd Doulton Road, Cradley Heath West Midlands, B64 5QB, UK T +44 (0) 384 567 755, F +44 (0) 384 567 70 E info@morssmitt.co.uk (c) Copyright 20 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Nieaf-Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Nieaf-Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.