TX OPEN RS232/485 module



Similar documents
Digital input modules

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

PCS0100en Persy Control Services B.V. Netherlands

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

IntesisBox Modbus Server Fidelio IP

is then retained absolutely without interruption.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

IntesisBox Modbus Server SAMSUNG Air Conditioners

RRV934. Multi-controller. Synco living

OZS Web server. For LPB/BSB plants

Waveguide Access Point WGA631. Product Guide

Automation stations modular series

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Modular I/O System Analog and Digital Interface Modules

IntesisBox KNX Modbus RTU master

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

IntesisBox KNX Mitsubishi Heavy Industries AC

Redundancy Module QUINT-DIODE/40

Accessories SUNNY REMOTE CONTROL

PXM20-E. Operator unit DESIGO PX

IntesisBox KNX LG Air Conditioning

Air damper actuators

VAV compact controller KNX / PL-Link

KNX Panasonic Air Conditioners

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

OZW30. Central Unit SYNERGYR

IntesisBox KNX - LON

Three-phase monitoring relay CM-PFE

TX2123 RS485 TO ETHERNET ADAPTOR

IntesisBox KNX Modbus TCP master

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

PHOENIX CONTACT Features

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

HARTING econ 3000 Introduction and features

CompactLogix Power Supplies Specifications

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

HARTING mcon 1000 Introduction and features

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

OZW V2.0. Web server. Synco TM, Synco TM living

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Installation instructions CAN/RS232-USB interface CANfox EC / / 2010

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AXIS T81B22 DC 30W Midspan

Introduction. Features. Industrial 2 ports RS-422/485 with Surge PCI-Express Low Profile Serial Card

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Rack mounted telephone- and leased line modem for industrial applications

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

HARTING mcon 3000 Introduction and features

Telephone- and leased line modem for industrial applications TD-36

Duct Humidity Transmitter

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

IFS SP-PoE Splitter User Manual

Product and functional description

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

CompactRIO crio-9052

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Modbus Server SAMSUNG Air Conditioners

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Strato Pi Hardware Guide

Quick Connect. quick - simple - efficient.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

connecdim Gateway G1 Ethernet TCP/IP to DALI

R.C.C.B. s two-pole LEXIC

MINI MCR-SL-R-UI(-SP)

48 SERIES Relay interface modules 10 A

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

VAV compact controller KNX / PL-Link

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

AXIS 291 1U Video Server Rack Installation Guide

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Safety technique. Emergency stop module BO 5988 safemaster

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Transcription:

s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the DESIGO building automation and control system (Version 4 or higher) Suitable for operation using pre-defined applications from Siemens or using in-house developed applications USB interface for connecting the TX OPEN Tool Compact design per DIN 4 880 Easy installation and setup Plug-in screw terminals Power from Island bus (DC 4 V) Simple, fast diagnostics CMN8185en_0 5 Nov 009 Building Technologies

Function The TX OPEN RS/485 module integrates third-party systems via RS or RS485 interface to the DESIGO building automation and control system. The required applications are loaded onto the module via the USB interface. Siemens offers finished applications for the following systems: Modbus (Engineering guide CM110571) M-bus (Engineering guide CM11057) SED (Engineering guide CM11057) Additional applications are currently being prepared You may also develop your own applications using Microsoft embedded Visual C++ 4.0, see Developer's guideline for the TXI1.OPEN, CM110570. The TX OPEN RS/485 module is powered directly with DC 4 V from the island bus. A webpage that may be viewed in the web browser via the USB interface, displays the interface configuration and values from the third-party system / device. The TX OPEN Tool supports the download of firmware and applications as well as the configuration data. Type summary Product No. Stock number Designation TXI1.OPEN S55661-J100 TX OPEN RS/485 module Accessories Configuration software TX OPEN Tool (Please contact your regional company for orders) Ordering When ordering, please specify the quantity, designation, product number and stock number. Example: 10 TX OPEN RS/485 Module TXI1.OPEN, S55661-J100 Equipment combinations Note: Version.7 The TX OPEN RS/485 module is suitable for using an island-bus capable automation station, i.e. in plants with version 4 or higher. For plants with versions up to.7, only I/O OPEN modules from the PT-I/O range are suitable.. / 8

Design and technology Overview F 1 TX RX GND _ + RUN B A G RS RS485 D 8 7 9 6 0 5 1 4 E 8 7 9 6 0 5 C G x10 x1 Address COM 1 4 F Key A Plug-in screw terminal for RS and RS485 (Changeover via software) Terminal RS RS485 1 TX + RX GND (Potential equalization) B LED "RUN" Power OK C LED COM Communication (RS) D USB connection for TX OPEN Tool E Rotary switches to set module address G 8185Z01_01 F G Bus connector Attachment slider for standard rails Mechanical properties Housing The housing complies with DIN 4880 and is 96 mm wide. During mounting, ensure sufficient convection (max. ambient temperature 50 C). Electrical properties Power Interfaces Island bus System ground Protection against incorrect wiring The TX OPEN RS/485 module is powered directly with DC 4 V from the island bus. No separate power required. Plug-in screw terminal for serial interfaces RS and RS485 USB plug type B for connecting the TX OPEN Tool The TX OPEN RS/485 module has contacts on the left and right side of the housing for the island bus. The module is plugged in between existing modules or attached at the end of a I/O row. The serial interfaces RS / RS485 are electrically isolated from the island bus side. The connected third-party system may be earthed. All terminals are protected against short circuit and incorrect wiring using AC/DC 4 V. Side bus connector: No protection Voltage higher than AC / DC 4 V: No protection / 8

Interfaces General RS RS485 Bus terminator Serial interfaces are electrically isolated The serial interfaces use the same connection terminals. You can use either RS or RS485 (Changeover via software). The interface supports baud rates from 00 to 11500 Baud. The signals RXD and TXD are available, but without handshake signals. The interface supports baud rates of 9600 and 1900 Baud. You can switch up a bus termination via software in the I/O OPEN module (1nF, 10 Ohm in series). Signaling RUN (green) COM (green) LED displays power is available and sufficient. This LED displays communications on the RS side. Address switch The module address is switched using the two rotary switches. The factory setting is 00 (the TX OPEN RS/485 module is inactive). Corresponds to a open address key in an I/O module. Related documents Document Number [1] TX OPEN developer's guideline CM110570 [] TX-OPEN Modbus engineering CM110571 [] TX OPEN M-bus engineering CM11057 [4] TX OPEN SED engineering CM11057 [5] TX OPEN Tool online help -- [6] TX-I/O module, data sheets CM1N817... [7] TX-I/O Planning and installation manual CM11056 Disposal The device is classified as waste electronic equipment in terms of the European Directive 00/96/EC (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. 4 / 8

Mounting Fixings Order Exchange Permissible mounting positions The device is mounted on a standard rail 5 x 7.5 mm (tophat rails TH5-7.5 per EN60715) The device can be plugged into any position on the I/O row. One TX OPEN RS/485 module may be removed from the row of modules. Please note, however, that the island bus and power is interrupted for all subsequent modules. TX-I/O devices can be mounted in any position: You must ensure, however, that sufficient ventilation is available to maintain the permissible ambient temperature (max. 50 C). Technical data Operating voltage Power consumption Power from the island bus. No separate power required. DC 4 V 55 ma / 1. W Protection against shortcircuit Side bus connector No protection! and incorrect wiring Serial interfaces Protection against surges to AC/DC 4 V and short circuits Electronic isolation from island bus GND RS4/485 interface You can switch up a bus termination via software in the I/O OPEN module (1nF, 10 Ohm in series) USB interface Plug Type B (USB device) Data rate (USB 1.0 full speed) 1 MBit/s Electronic isolation from island bus GND No Protective switch against surges and over current Yes Connection terminals, plug-in Mechanical design Copper wire or copper stranded wires with ferrules Copper stranded wires without ferrules Screwdriver Maximum stud torque Plug-in screw terminal 1 x 0.6 mm to.5mm or x 0.6 mm to 1,0 mm 1 x 0.6 mm to.5 mm or x 0.6 mm to 1,5 mm Flat screwdriver size 1 with shaft ø 4.5 mm 0.6 Nm 5 / 8

Classification per EN 6070 Function of automatic control devices Degree of pollution Mechanical design Housing type IP class per EN 6059 Front parts in DIN excerpt terminal part Type 1 Protection class III IP0 IP0 Environmental conditions Standards, directives and approvals Operation Climatic conditions Temperature Humidity Mechanical conditions Transport Climatic conditions Temperature Humidity Mechanical conditions Product safety Automatic electrical controls devices for household and similar use Electromagnetic compatibility Immunity Industrial sector Emissions Residential, Light industry CE conformity Electromagnetic compatibility Low-voltage directive c-tick conformity as per Australian EMC Framework Radio Emission Standard UL approval (UL 916) As per IEC 6071-- Class K5 5... 50 C 5 95 % r.f Class M As per IEC 6071-- Class K -5...70 C 5 95 % r.f Class M EN 6070-1 EN 61000-6- EN 61000-6- 004/108/EC 006/95/EC Radio Communication Act 199 AS/NZS 548 75M5 Color Housing Light gray, RAL 705 Dimensions Housing as per DIN 4 880, see dimensions Weight With / without packaging 10g / 168g 6 / 8

8 7 7 8 Dimensions Dimensions in mm 45 44 70 77.4 90 98 108 1 9 0 1 9 0 1 6 6 5 5 4 4 96 7.1 8185M01 7 / 8

8 / 8 009 Siemens Switzerland Ltd Subject to change