URINE DIPSTICK Multistix 10SG



Similar documents
URINE TESTING USING THE MULTISTICK

CLINITEK POINT OF CARE URINALYSIS TESTING

Chapter 14 Urinalysis, Body Fluids and Other Specimens. Objectives:

THE URINALYSIS REAGENT STRIPS

Chapter. Guaiac Screening CHAPTER 4: GUAIAC TESTING SCREENING FOR OCCULT BLOOD. Page 1 of 5 Guaiac doc 6/24/2005

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

Urinalysis and Body Fluids CRg. Chemical Exam of Urine - bilirubin. Chemical Exam of Urine - bilirubin. Unit 3. Chemical Examination of Urine

OneStep Fecal Occult Blood RapiDip InstaTest. Cat #

Title: Microbiology Urine Screening Effective date: 05/08/2013. Summary of Significant Changes at this Revision

UNIT: Total and Direct Bilirubin

Contents. Approved by: Kent Lewandrowski, M.D. 6/1/2005 Written/Updated by: Gino Pagnani Date: 4/3/09

Vaginal ph Test (ph Hydrion TM Paper )

SAMPLE PROCEDURE , 09/11

INTRODUCTION TO CLINICAL PRACTICE AND CLINICAL SKILLS 2nd Year MEDICAL YEAR 2009/2010

Urisys 1100 Urine Analyzer. Policies and Procedures. for use with Urisys 1100 Urine Analyzer. This is a CLIA-Waived System

Care of the Catheterised Patient and Urinalysis

Quality Requirements of a Point of Care Testing Service

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Hemoglobin Testing using the Data Management HemoCue Analyzer

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved

Title: Fingerstick Glucose by Accu-Chek Inform

Contents. POCT Program Massachusetts General Hospital - Pathology Service 55 Fruit Street, Boston, MA 02114

EDUCATIONAL COMMENTARY RED BLOOD CELLS AND WHITE BLOOD CELLS IN URINALYSIS

Biochemistry Validation Form

TOTAL PROTEIN FIBRINOGEN

Urinalysis and Body Fluids CRg

Central Government Laboratory Department of Health and Environment

Cidex OPA Solution Training Checklist and Competency for Semi-Critical Medical Devices

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

General. What is a laboratory test? What is a waived test?

LABORATORY 3: Microscopic Urinalysis

Florida Nursing Assistant Academy #2926 COURSE SYLLABUS

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Policy S:PC-2110 v15. Fairview Health Services Department Laboratory / Nursing Laboratory Acute Care: Section Collection Category Provision of Care

How Does a Doctor Test for AIDS?

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

Chapter 23. Composition and Properties of Urine

Direct Antiglobulin Test (DAT)

Textbook: Chapter 12 pages , Chapter 13 pages

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

SURGICAL SERVICE SPECIALTY UROLOGY SURGICAL SPECIALTY

Diagnosis of HIV-1 Infection. Estelle Piwowar-Manning HPTN Central Laboratory The Johns Hopkins University

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

Course outline. Code: MLS211 Title: Medical Biochemistry

Quaternary Ammonium Compounds DOC

Infectious Waste Management Plan

Enteric Unknowns Miramar College Biology 205 Microbiology

Oxidizer(s) Management and Use Guidelines

Scope and application: For testing residual corrosion inhibitors (oxygen scavengers) in boiler feed water or condensate

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Beware that Low Urine Creatinine! by Vera F. Dolan MSPH FALU, Michael Fulks MD, Robert L. Stout PhD

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

Cold Agglutination Titer detecting Cold Reacting Antibodies

LAB 3: DIGESTION OF ORGANIC MACROMOLECULES

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Factors Affecting Enzyme Activity

MATERIAL SAFETY DATA SHEET

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

ADMINISTRATIVE MANUAL Policy and Procedure

Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians

CK-MB TEST CARD 004A302

Protocol for Macroscopic and Microscopic Urinalysis and Investigation of Urinary Tract Infections

Crime Scene Unit Presumptive Testing Procedures. Evidence Collection Division

Safety Data Sheet Avesta Neutralization Agent 502

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Blood Borne Pathogen Exposure Control Plan Checklist

University of Kentucky / UK HealthCare Policy and Procedure. Policy # A03-030

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

MEDICAL DEVICE GUIDANCE

Laboratory Waste Disposal

ILLINOIS DEPARTMENT OF CENTRAL MANAGEMENT SERVICES CLASS SPECIFICATION CLINICAL LABORATORY TECHNICIAN SERIES

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

UNIVERSITY OF CONNECTICUT HEALTH CENTER CORRECTIONAL MANAGED HEALTH CARE POLICY AND PROCEDURES FOR USE WITHIN THE CONNECTICUT DEPARTMENT OF CORRECTION

Standard Operating Procedure for a Chemical Spill

LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

The Empirical Formula of a Compound

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

DR/4000 PROCEDURE. CHLORINE, Free

Urinalysis: The Underappreciated Diagnostic Tool Megan Morgan, VMD, DACVIM

cobas 6500 urine analyzer series Fully automated urine work area on a modular platform

Phosphorus, Reactive (Orthophosphate)

Urinary Tract Infections

Experiment 10 Enzymes

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Oxivir Tb and Accelerated Hydrogen Peroxide (AHP) Frequently Asked Questions

UltraClean Soil DNA Isolation Kit

THE ACTIVITY OF LACTASE

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

MANUAL WBC LAB OBJECTIVE

CRMC Laboratory Draw Station is located in the Out Patient Services area. We are available 6AM to 6PM daily.

Quality Assurance Guidelines for Testing Using Rapid HIV Antibody Tests Waived Under the Clinical Laboratory Improvement Amendments of 1988

Lab 02: Blood Cytology (20 points)

Prepublication Requirements

XV.Quality Assurance in the Blood Bank

Ethyl Glucuronide. Where is the Drug? Detection Windows. Urine. Blood. Absorption and Distribution. Metabolism. Excretion

SAFETY DATA SHEET. Blue Hand and Body Shampoo

SAFETY DATA SHEET Glen-Pak TM DNA purification cartridge (for use with disposable syringes) xx

Transcription:

The Johns Hopkins Hospital Point-of-Care Testing Program URINE DIPSTICK Multistix 10SG Operator Competency Only operators who have completed a defined training program and can demonstrate competence will be able to perform Urine Dipstick testing. Operator competency will be assessed annually by two methods. a. Successful performance of quality control (Quantimetrix Dropper Plus Level 1 and Level 2) b. One of the following: Testing an unknown specimen Having the supervisor or qualified delegate periodically observe routine work Written test Test Order A physician s order, standard protocol, or order by other health professionals authorized to request laboratory tests is required for urine dipstick testing. Reagents and Storage The Siemens Urine Dipstick bottles and Urine Controls are to be dated when initially opened. The Opened Date and New Expiration Date are to be recorded on the Quantimetrix Dropper Plus Urine Control bottles when stored at room temperature. Do not use the Urine Dipsticks and Urine Controls after the expiration date. 1. Multistix 10SG urine dipsticks are stable until the manufacturer s expiration date printed on the bottle when stored properly. 2. Urine dipsticks are stored in the original, tightly sealed bottle at room temperature (15-30 o C or 59-86 o F). 3 Do not store dipsticks in direct sunlight. Protect dipsticks from heat sources and light exposure. 4. The Quantimetrix Dropper Plus Urine Controls are stable for one month at room temperature (18-25 C or 64-77 F). Do not store above 30 C (86 F). 5. The Quantimetrix Dropper Plus Urine Controls can also be stored at 2-8 C (35-46 F) in a temperature monitored refrigerator. When stored refrigerated, the Urine Controls are stable until the expiration date stated on the label. Do not freeze. Quality Control Label A JHMI Quality Control label should be affixed to the bottle of urine dipsticks when it is first opened. Record the open date at the top of the QC label in the space below Date Opened. Copyright 2005 Johns Hopkins Hospital All rights reserved Revision: 10/2010 1

Quality Control Frequency 1. Weekly on each opened bottle of urine dipsticks. 2. Each time a new bottle of urine dipsticks is opened. Quality Control 1. Record the lot number and expiration dates of the urine dipsticks and controls on the Urine Dipstick QC log sheet, along with the date, time and operator initials. 2. Ensure that the control solutions are at room temperature before use. 3. Test the control solutions (Level 1 and Level 2) by squeezing the control bottle and drawing the control solution across all of the reagent pads, thoroughly saturating each pad. Do not aspirate excess control back into the bottle. Drain excess from dipstick. Time appropriately. 4. Record control results on the Urine Dipstick QC Log. Record results in the units specified on the urine dipstick bottle. 5. Note any QC failures and corrective action taken on the Urine Dipstick QC Log. 6. If both levels of controls are within the acceptable ranges, record the date and operator initials on the JHMI QC label affixed to the reagent strip bottle. This bottle may be used for one week for patient testing. Quality Control Results Documentation Summary 1. Record date, time, operator initials and lot numbers of dipsticks and controls on log sheet. 2. Record the Quality Control results in the units specified on the bottle of urine dipsticks. 3. Do not use + or for results (example: Record blood as 3+ not +++, NEG/negative, POS/positive) 4. Place a mark in the QC Pass/Fail Column to note whether QC passed or failed. 5. Document any QC failures and corrective actions on the Urine Dipstick QC log sheet Quality Control Failures and Corrective Actions If one or more of the urine control solutions fail to give expected results: 1. Check to make sure that the control solutions and urine dipsticks have not expired. 2. Repeat test. 3. If the repeat test fails, open a new set of urine controls and repeat. 4. If this test fails using the new controls, open a new bottle of urine dipsticks and repeat. 5. If the repeat test fails using the newly opened bottle of dipsticks and controls, STOP PATIENT TESTING AND REPTING OF PATIENT RESULTS until the quality control issues are resolved and the expected results are obtained and recorded. 6. Document all steps taken in the Comment Section of the Urine Dipstick QC Log sheet. 7. Contact the POCT Program Office for assistance. Copyright 2005 Johns Hopkins Hospital All rights reserved Revision: 10/2010 2

Specimen Collection 1. Use at least 2 unique patient identifiers (neither to be the patient s room number) to verify a patient s identity when collecting samples for testing. 2. Label the urine container (not the lid) with the patient identifiers. 3. Samples must be fresh (not refrigerated) and tested promptly within 1 hour of collection. 4. Gloves must be worn during sample collection and testing (Standard Precautions). Patient Testing 1. Check the JHMI QC label on the bottle of urine dipsticks or the Urine Dipstick QC log sheet to make sure that quality control has been performed for the week. If not, stop and perform QC before doing any patient tests. 2. Remove a test strip from the bottle of urine dipsticks. Recap the bottle before proceeding. 3. Gently swirl the urine container in order to thoroughly mix the urine. 4. Immerse the pads on the dipstick in the urine sample and remove immediately. 5. While removing the strip from the urine container, wipe the edge of the dipstick on the container rim to remove excess urine. 6. Hold the dipstick level to avoid mixing reagents from adjacent pads. 7. Hold the dipstick near the color chart on the bottle of dipsticks and read in the order and at the time intervals specified in the attached Interpretation Chart. The glucose pad is nearest the handheld end of the dipstick. Color changes that occur after the correct reading time are erroneous. 8. Record the patient s results, along with the date, time and operator initials on the chart, EPR or flow sheet. 9. When documenting the results in the patient s chart, place a check mark ( ) or QC okay next to the results to indicate that Quality control has successfully been run within one week. 10. Results should be noted as Point-of-Care Testing results in order to distinguish them from laboratory results. 11. Dispose of urine samples in toilet when testing is finished. 12. Discard used test strips in a JHMI approved biohazard container Patient Result Reporting 1. Record all urine dipstick test results, including negative results, with the date, time, operator initials and care actions in the patient chart. 2. Record the patient results in the reporting units specified on the bottle of urine dipsticks. 3. Do not use (+) or ( ) signs to report positive and negative results. Record negative results as Neg or Negative and positive results as Pos or Positive. 4. Record a +++ result as 3+, a ++ result as 2+, etc. 5. Place a check mark ( ) or QC okay next to the patient results to indicate that external Quality Control had been successfully run within the previous week on the bottle of dipsticks used. 6. Note the results as Point-of-Care results to differentiate results from central laboratory results. Copyright 2005 Johns Hopkins Hospital All rights reserved Revision: 10/2010 3

Abnormal Results 1. Abnormal results are defined as: a. Any value greater than negative/normal for glucose, bilirubin, ketones, protein, urobilinogen, blood, nitrite or leukocytes. b. Both the normal and abnormal urinary ph range is 5-8.5. c. Random urines may vary in specific gravity from 1.001-1.035. 2. Questionable urine dipstick results, problems with the testing procedure or results that do not match the clinical condition should be reported to the physician/provider to determine if additional follow-up is needed, i.e. repeat the point-of-care test, send a sample to the core laboratory etc. 3. In the event of abnormal or questionable urine dipstick results, document in the patient s record that the physician/provider has been notified. Critical Action Value 1. Ketones: Large amount (80-160 mg/dl) 2. Notify the patient s physician/provider to determine if additional follow-up is needed. 3. Document in the patient s record that the physician/provider was notified and that a read-back of the Critical Action Value occurred and was verified. Copyright 2005 Johns Hopkins Hospital All rights reserved Revision: 10/2010 4

INTERPRETATION CHART F URINE DIPSTICK RESULTS: Results are read and recorded as follows: Test Read at Test Interpretation Glucose 30 seconds Negative, 1/10 (tr) g/dl, ¼ g/dl, ½ g/dl, 1 g/dl, 2 or more g/dl Negative, 100 mg/dl, 250 mg/dl, 500 mg/dl, 1000 mg/dl, 2000 or more mg/dl Bilirubin 30 seconds Negative, Small, Moderate, Large Negative, 1+, 2+, 3+ Ketone 40 seconds Negative, Trace, Small, Moderate, Large Negative, 5mg/dL, 15 mg/dl, 40 mg/dl, 80 mg/dl, 100 mg/dl Specific Gravity 45 seconds 1.000 1.030 * For increased specific gravity accuracy, 0.005 is added to readings from urines with ph equal to or greater than 6.5. Blood 60 seconds Negative, Trace, Small, Moderate, Large Negative, Trace, 1 +, 2 +, 3 + ph 60 seconds 5.0, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5 Protein 60 seconds Negative, Trace, 30 mg/dl, 100 mg/dl, 300 mg/dl, over 2000 mg/dl Negative, Trace, 1 +, 2 +, 3 +, 4 + Urobilinogen 60 seconds 0.2 mg/dl, 1 mg/dl, 2mg/dL, 4 mg/dl, 8mg/dL Nitrite 60 seconds Negative, Positive Leukocytes 2 minutes Negative, Trace, Small, Moderate, Large Negative, Trace, 1+, 2+, 3+ Copyright 2005 Johns Hopkins Hospital All rights reserved Revision: 10/2010 5

Limitations and Interferences 1. Substances that cause abnormal urine color, such as visible levels of blood and bilirubin and drugs containing dyes (ex. Pyridium), nitrofurantoin (ex. Macrodantin), or riboflavin may affect the readability of the reagent pad areas on the strip. The color development on the reagent pads may be masked or a color reaction produced that could be interpreted as a false positive. These specimens should be sent to the main laboratory for testing. 2. The limitations and interferences for each analyte are as follows: Test Limitations and Interferences Glucose Test is specific for glucose. Ketone bodies reduce the sensitivity of the test Moderately high ketones (40 mg/dl) may cause false negative results for specimens containing small amounts of glucose (75-125 mg/dl). This combination of ketones and low glucose levels is metabolically improbable in screening. Bilirubin Test is specific for bilirubin. Indican (indoxyl sulfate) can produce a yellow-orange to red color that may interfere with the interpretation of a negative or positive reading. Metabolites of Lodine (etodolac) may cause false positive or atypical results. Atypical colors (unlike the color blocks on the color chart) may indicate that bilirubin-derived bile pigments are present and may be masking the bilirubin reaction. These colors indicate bile pigment abnormalities and the urine should be tested further. Ketones In ketoacidosis, starvation, or with other abnormalities of carbohydrate or lipid metabolism, ketones may appear in urine at levels of 10 mg/dl or higher before serum ketones are elevated. False Trace results may occur with highly pigmented urine specimens. False Trace results may occur with urine containing large amounts of levodopa metabolites. Compounds such as mesna (2-mercaptoethane sulfonic acid) that contain sulfhydryl groups may cause false positive results or an atypical color reaction. Specific Gravity For increased accuracy, 0.005 is added to readings from urines with ph 6.5. The Siemen s SG test is dependent on ions in urine and results may differ from those obtained with other specific gravity methods when certain nonionic urine constituents, such as glucose, are present. Highly buffered alkaline urines may cause low readings. Presence of moderate quantities of protein (100-750 mg/dl) may cause elevated readings. Blood Test is equally sensitive to myoglobin as to hemoglobin. Capoten (captopril) may reduce the reactivity of the test. False positive results may be the result of: a. Oxidizing contaminants (ex. Hypochlorite) b. Microbial peroxidase associated with urinary tract infections. ph Bacterial growth by certain organisms in a urine specimen may cause a marked alkaline shift (ph > 8.0), usually because of urea conversion to ammonia. Protein Contamination of urine with skin cleansers containing chlorhexidine may affect protein results. Test is not specific for a particular protein- proteins other than albumin can cause a positive reaction. Test is less sensitive to mucoproteins and globulins which are generally detected at levels of 60 mg/dl or higher. Visibly bloody urines may cause falsely elevated results. Urobilinogen The test pad may react with interfering substances known to react with Ehrlich s Reagent, such as p-aminosalicylic acid and sulfonamides. Atypical color reactions may be obtained in the presence of high concentrations of p-aminobenzoic acid. False negative results may be obtained if formalin is present. Strip reactivity increases with temperature; the optimum temperature is 22-26 C (72-79 F). The test is not a reliable method for the detection of porphobilinogen. Copyright 2005 Johns Hopkins Hospital All rights reserved Revision: 10/2010 6

Limitations and Interferences (continued): Test Limitations and Interferences Nitrite Test is specific for nitrite. Nitrite concentration during infection increases with the length of time the urine is retained in the bladder prior to collection. Pink spots or pink edges should not be interpreted as a positive result. False negative results may occur with: a. Shortened bladder incubation of the urine b. Absence of dietary nitrate. c. Presence of nonreductive pathological microbes. Leukocytes A strip result of Small or greater is a useful indicator of infection. Trace results observed repeatedly may be clinically significant. Elevated glucose concentrations ( 3 g/dl) may cause decreased test results. The presence of cephalexin (Keflex), cephalothin (Keflin), or high concentrations of oxalic acid may cause decreased test results. Tetracycline may cause decreased reactivity, and high levels of the drug may cause a false negative reaction. Positive results may occasionally be due to contamination of the specimen by vaginal discharge. Copyright 2005 Johns Hopkins Hospital All rights reserved Revision: 10/2010 7