CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections



Similar documents
This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Communication, Signal & Data Cables

HOW TO MAKE YOUR OWN CAT 5 TWISTED-PAIR NETWORK CABLES

Ethernet Cat 5e & Cat 6 Patch Panels

Christopher Rathgeb ECE 453 Dr. Qi 9/19/2006. Task 1: Make an Ethernet cable yourself.

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Chapter 2 TCP/IP Networking Basics

Enhanced Category 5 Cabling System Engineering for Performance

Network Cabling Guide

iseries Ethernet cabling and configuration requirements

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Appendix B Network, Routing, Firewall, and Basics

Ethernet Patch Cord Wiring

Standards Affecting a Premise T-1 Installation

Crestron CAT5 Wiring Reference Guide

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Gigabit Ethernet on Copper Cabling Infrastructures

Terminating 25-Pair Cable and 4-Pair Cross Connects

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

Total Solutions Verification

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Understanding the Electrical Performance of Category Cables

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

2 Network Media. Copper Core Cable

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Specification SFTP CAT6 Network Cable 23AWG CU

Gigabit Switching Ethernet Media Converters - Product User Guide

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Chapter 4 Connecting to the Internet through an ISP

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

How To Get A Better Signal From A Fiber To A Coax Cable

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Data Communications Competence Center

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Lightning Protection Guide. PTP 400 and 600 SERIES

Installation & Weatherproofing Guide for ENCOM Broadband Radios

How to Choose the Right Cable Category

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

LocoNet, the Digitrax Difference

LAN Installation Handbook

Category 6 UTP - Cabling System

TCP/IP Networking Basics. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Integrated Home Networks

Gigabit Ethernet over fiber optic cable.

Application Note: How to Connect a Wired Ethernet Port to the WiPort

PROFINET Diagnostics Software and Tools

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Network Design. Yiannos Mylonas

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Index. ROPIX P18 Hardware ROPIX P18 Software ROPIX P18

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Implementing Fast Ethernet

SECTION TELECOMMUNICATIONS ACCEPTANCE TESTING

Coaxial Cable Solutions Guide

Zero-Variable Wireless Infrastructure Deployment. Datasheet. Models: BM2HP, BM5HP. Completely integrated Radio

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

WHITE PAPER December, 2001

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

Panduit 28 AWG Patch Cords Installation Guideline

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

with Component Rating A Simple Perspective

Copper Patch Cords. Impact On Network Performance and Reliability

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

VOPEX-C5HDMI-4 HDMI Digital Video and Audio Splitter/Extender via CAT6 Installation and Operation Manual

Network Engineers Everywhere:

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Experts in Chem-Feed and Water Treatment. How To Connect. Aquatrac Training. ProMinent Fluid Controls

Cabling and Building Infrastructure for Technology

8-Port 10/100Mbps 802.3af / 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch. FGSD-910P / FGSD-910HP User s Manual

CCTV System Troubleshooting Guide

How to Determine the Right Fiber Optic Network Backup Switch For Your Application

Broadband 101: Installation and Testing

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Making a DB to RJ45 adapter.

Fast Ethernet FX-TX Media Converter. User Manual RINGDALE

Comtrol Cable User Guide

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

Power over Ethernet (PoE)

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.

GORE Aerospace Cables

Transcription:

CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections RJ 45: (RJ xx: telephone connection interfaces, registered with the FCC, the U.S. Federal Communications Commission.) Pins: When you are looking at the wiring end (the entryway for the cable to be inserted into the connector) of a plug with the latch down, pin 1 is on the left. CAT 5: 4 Twisted Pairs at 24 AWG pair 1: blue pair 2: orange pair 3: green pair 4: brown (twisted about 3 times per inch) Ethernet uses only pair 3 (green, on pins 1 and 2), and pair 2 (orange, on pins 3 and 6). EIA/TIA specifies RJ-45 (ISO 8877) connectors for UTP cable (unshielded twisted pair). Impedance: 100 Ohms Max length of a segment: 100 meters/330 feet Frequency rating: 100MHz Capacitance: 13.5 to 17 picofarads per foot Attenuation: 23 to 67dB per 1000 feet Far-End Crosstalk (FEXT): 32 to 51 db at 1000 feet CAT 5 Cable Specifications: Max. Attenuation per 1000 ft/ Resistance per 1000 ft/ Frequency 304 m 304 m Capacitance Impedance 4 MHz 13 db 28,6 ohms 14 pf/ft 100 ohms 10 MHz 20 db 28,6 ohms 14 pf/ft 100 ohms 20 MHz 28 db 28,6 ohms 14 pf/ft 100 ohms 100 MHz 67 db 28,6 ohms 14 pf/ft 100 ohms

How to make a good CAT5 Cable. A good CAT5 termination provides you a connection that has the following important characteristics: a proper wire crimp, a wire insulation strain relief crimp and a cable strain relief crimp. REMEMBER To avoid NEXT and FEXT problems, it is also important to not unwind the wires more than necessary. Conversely, while maintaining the twists as far as possible is important, don't let it stop you from inserting the wires as far as possible. I've made a lot of these cables personally, and this is how I do it: * Strip the cables Jacket back one full inch. * Untwist the wires back to within 1/8" of the jacket. * Arrange the wires in the order in which you want to crimp them, (ie. 568A, 568B, etc.). * Grasp the wires firmly, between your thumb and forefinger, flatten them, and even wiggle them a bit, to take out the curliness, (concentrate your efforts on the bottom 1/2") the wires must lay flat and together, aligned as close as possible. * While holding the wires firmly, cut off the the wires 1/2" from the cables jacket (Cut the wires with some sharp wire strippers or even high quality scissors, avoid wire cutters that flatten the ends of the wires insulating material, this makes stuffing the wires very difficult.) * Stuff the wires into the connector, making sure the wires stay lined up. NOTE: The wires should reach the end of the little tube they are in, if possible, or at least past the farthest point of that "little funny Gold Plated thingy" above it, which will terminate it. * The jacket should go even with the end of the first indent, if possible, as it's a strain relief for the cable. * Insert it into the crimping tool, and Crimp it! All of this is very dependant on the tools you are using, the connectors you are using, and the cable you are using. A bad combination can be hell! How to wire a CAT5 (EIA 568-B*) Cable. connector #1 connector #2 1 WHT/ORG 2 ORG/WHT 3 WHT/GRN 6 GRN/WHT How to wire a CAT5 (EIA 568-A*) Cable. 1 WHT/ORG 2 ORG/WHT 3 WHT/GRN 6 GRN/WHT connector #1 connector #2 1 WHT/GRN 1 WHT/GRN *The real difference between 568A and 568B is that the White/Orange-Orange/White and White/Green-Green/White pairs are swapped. Crimp strain relief: Cable jacket should be inserted past the strain relief crimp (see picture).

How to wire a "Crossover" Cable. (EIA 568-B*) connector #1 connector #2 1 WHT/ORG 2 ORG/WHT 3 WHT/GRN 6 GRN/WHT USOC crossover cables are like this: 1 WHT/GRN 7 BRN/WHT 8 WHT/BRN 1 WHT/BRN 2 WHT/GRN 4 WHT/BLU 5 BLU/WHT 7 GRN/WHT 8 WHT/BRN 7 WHT/GRN 6 WHT/ORG 3 ORG/WHT 1 BRN/WHT 10BaseT and 100BaseT Cross Cable C1 Pins Color Code Color Code C2 Pins 1 White/Orange White/Green 1 2 Orange Green 2 3 White/Green White/Orange 3 4 Blue Blue 4 5 White/Blue White/Blue 5 6 Green Orange 6 7 White/Brown White/Brown 7 8 Brown Brown 8 color abbreviations: WHT-WHITE BRN-BROWN ORG-ORANGE GRN-GREEN BLU-BLUE The first color listed in the color pair is dominant color of the wire. In other words, WHT/ORG is a white wire with orange stripes.

ISDN BRI RJ45 Standard (574616-MO97): RJ 45 Pin 1 2 3 4 5 6 7 8 Pair Tx+ Rx + Rx - Tx - ISDN PRI RJ45 Standard (574616-MO97): RJ 45 Pin 1 2 3 4 5 6 7 8 Pair Tx+ Rx + Rx - Tx - (T1 PRI X-Over = Essentially, tie Pins 1[connector 1] P4[connector 2] and P2[connector 1] P5[connector2], then Pins 1[connector 2] P4[connector 1] and P4[connector 2] P5[connector1]) 10BaseT and 100BaseT Cross Cable C1 Pins Color Code Color Code C2 Pins 1 White/Orange White/Green 1 2 Orange Green 2 3 White/Green White/Orange 3 4 Blue Blue 4 5 White/Blue White/Blue 5 6 Green Orange 6 7 White/Brown White/Brown 7 8 Brown Brown 8 (Ethernet X-Over = Essentially, tie Pins 1[connector 1] P2[connector 2] and P3[connector 1] P6[connector2], then Pins 1[connector 2] P2[connector 1] and P3[connector 2] P6[connector1]) Cat5 Wiring Standards, Listed Pin EIA/TIA 568A AT&T 258A, EIA/TIA 568B 10Base-T 10Mbps Cat3 100Base-TX 100Mbps Cat5 100Base-T4 100Mbps Cat3 100Base-T2 100Mbps Cat3 1000Base-T 1Gbps Cat5+ 1 white/green white/orange TX+ TX+ TX D1+ BI DA+ BI DA+ 2 green/white orange/white TX- TX- TX D1- BI DA- BI DA- 3 white/orange white/green RX+ RX+ RX D2+ BI DB+ BI DB+ 4 blue/white blue/white na na BI D3+ na BI DC+ 5 white/blue white/blue na na BI D3- na BI DC- 6 orange/white green/white RX- RX- RX D2- BI DB- BI DB- 7 white/brown white/brown na na BI D4+ na BI DD+ 8 brown/white brown/white na na BI D4- na BI DD- BI=BI directional data RX=Receive Data TX=Transmit Data

Testing CAT5 Cable Since the Cat 5 cable is used to the fullest extent of its performance envelope, testing is very important. There are four basic tests that are called for as part of the EIA/TIA specs for all UTP cables: wiremap, length, attenuation and crosstalk. Let's take a look at each of them. Wiremap Wiremapping simply means that each wire is hooked up correctly, with no open wires or shorts. That's mostly very straightforward. Each pair must be connected to the correct pins at the plugs and jacks, with good contacts in the terminations (called "IDC" or insulation-displacement connections, by the way, since the wires are held in knife-edge terminations that slice through the insulation and dig into the copper wire, forming a tight seal.) Most of the failures are simple enough to understand, like reversed wires in a pair, crossed pairs or opens and shorts. One possible failure is crossed pairs, caused when both wires of a pair are crossed at one termination. The usual cause of a crossed pair is a 568A termination on one end and a 568B on the other. The most difficult wiremap problem is a split pair, when one wire on each pair is reversed on both ends. The usual wiremap will pass but crosstalk will fail. It takes a Cat 5 tester or a more sophisticated wiremapper to find a split pair, as most wiremappers do not check crosstalk. Length Since 568 cables must be less than 90 meters (296 feet) in the link and 100 meters in the channel (328 feet), length must be tested. This is done with a "time domain reflectometer" which is a fancy term for cable "radar". The tester sends out a pulse, waits for an "echo" from the far end and measures the time it took for the trip. Knowing the speed in the cable, it calculates the length. If you have a short or open, the TDR will tell you where the problem is too, making it a great tool for finding problems. Attenuation The proper operation of a LAN on the cable plant requires the signal strength be high enough at the receiver end. Thus the attenuation of the cable is very important. Since LANs send high speed signals through the cable and the attenuation is variable with the frequency of the signal, the fancy automated testers test attenuation at several wavelengths specified in the 568 specs (TSB-67 to be exact). This test requires a tester at each end of the cable, one to send and one to receive, then one of them will calculate the loss and record it. There are pass fail criteria for the cable at Cat 3, 4 and 5 max frequencies. Crosstalk (NEXT) It's called NEXT for "near end cross talk" since it measures the crosstalk (signal coupled from one pair to another) at the end where one pair is transmitting (and the transmitted signal is largest causing the most crosstalk.) Crosstalk is minimized by the twists in the cable, with different twist rates causing each pair to be antennas sensitive to different frequencies and hopefully not picking up the signals from it's neighboring pairs. Remember what we said: you MUST keep the twists as close to the terminations as possible to minimize crosstalk.

Cat 5 testers measure crosstalk from one pair to all three other pairs for each pair and compare it to the 568 specs, giving a pass/fail result. Some also calculate "ACR" or attenuation/crosstalk ratio, as it is a measure of how big the crosstalk signal is to the attenuated signal at the receiver. You want this number as big as possible, as it is an indication of the signal to noise ratio. More Tests Coming Soon! The next generation of test specs will probably include a number of new tests to insure higher performance from the cable. These tests relate to higher bandwidth usage of the cable and simultaneous use of all four pairs, perhaps even in both directions at once! Powersum NEXT is the NEXT on one pair when all three others are carrying signals. This is realistic with Fast Ethernet and Gigabit Ethernet where all pairs carry signals, often simultaneously. Manufacturers routinely test cables for this characteristic now, but there is no standard yet for the performance of the cable or terminations. FEXT is far end crosstalk, looking at the effect of the coupling from one pair to another over the entire length, measured at the far end. ELFEXT is equal level FEXT, or the ratio of FEXT to attenuation, sort of like ACR. Delay Skew measures how much simultaneous pulses spread out at the far end. This measures the speed on each pair, which may be different due to the variations in number of twists (more twists means longer wires) or insulation. Return loss is a measure of the reflections from the cable due to variations in the impedance. These reflections can cause signal degradation, especially if the pairs are used in a fullduplex (bidirectional) mode. Testers UTP testers are mostly automated, push a button get a pass/fail simple. Wiremappers test the connections and Cat 5 testers test the performance at high frequencies. In fact, Cat 5 testers test everything, wiremap, length, attenuation and crosstalk in one connection, give you a pass/fail result, some help on troubleshooting, store the result and practically everything else but make coffee. Some installers use the Cat 5 tester for all testing, after the cable is installed. Others have each crew use an inexpensive wiremapper to make sure connections are correct before the Cat 5 tester is brought in, since it's a very expensive unit that needs a trained operation and many failures are simply wire map problems. By having each crew find and fix their own wiremap problems, testing and corrections are done as the cable is installed and the cost of the Cat 5 tester is not wasted on simple problems. It just provides the high frequency tests and documentation required by most users. Buying a Cat 5 tester today is a bit of a crap-shoot, since everybody knows the 568 spec will be upgraded to include more tests at higher frequencies soon, but nobody knows exactly how far. 155 MHz, 200 MHz, 250 MHz, higher? The best bet is to not buy a unit that is not already rated to higher frequencies or that cannot be upgraded easily! What The Heck Is A Certified Cable? Did the cable pass an exam and get a certificate? Well, sort of. This term has been used by vendors of testers to mean that the cable was tested and passed by one of the Cat 5 testers. It means that it meets the minimum specifications of TSB067 and should work with any network designed to operate on a Cat 5 link. This information researched and provided by Communication Design Group.912-786-0068